DeviceBD Onclarity HPV Assay
Generic NameKIT, DNA DETECTION, HUMAN PAPILLOMAVIRUS
ApplicantBecton, Dickinson and Company
7loveton Cir.
Sparks, MD 21152
PMA NumberP160037
Supplement NumberS008
Date Received09/02/2020
Decision Date02/09/2023
Product Code MAQ 
Advisory Committee Microbiology
Supplement TypeNormal 180 Day Track
Supplement Reason Labeling Change - Indications/instructions/shelf life/tradename
Expedited Review Granted? No
Combination ProductNo
Predetermined Change Control Plan AuthorizedNo
Approval Order Statement  
Approval for The BD Onclarity HPV Assay. The device is indicated as a qualitative in vitro test for the detection of Human Papillomavirus in clinician-collected cervical specimens using an endocervical brush/spatula combination or broom and placed in a BD SurePath vial or placed in ThinPrep Pap Test PreservCyt Solution . The test utilizes amplification of target DNA by the Polymerase Chain Reaction (PCR) and nucleic acid hybridization for the detection of 14 high-risk (HR) HPV types in a single analysis. The test specifically identifies types 16, 18, 31, 45, 51, and 52 while reporting the other HR HPV types in groups (33/58, 35/39/68, and 56/59/66).The BD Onclarity HPV Assay is indicated for use for routine cervical cancer screening as per professional medical guidelines, including triage of ASC-US cytology, co-testing (or adjunctive screen) with cytology, and HPV primary screening of women to assess the risk for cervical precancer and cancer. Patients should be followed-up in accordance with profession medical guidelines, results from prior screening, medical history, and other risk factors.WARNINGThe BD Onclarity HPV Assay is NOT intended:1) For use in determining the need for treatment (i.e., excisional or ablative treatment of the cervix) in the absence of high-grade cervical dysplasia. Patients who are HPV 16, 18 and 45 positive should be assessed for the development of high-grade cervical intraepithelial neoplasia according to current practice guidelines;2) For women who have undergone hysterectomy with removal of the cervix; and3) For use with samples other than those collected by a clinician using an endocervical brush/spatula combination or broom and placed in the BD SurePath Preservative Fluid Collection Vial or placed in PreservCyt Solution.HPV-negative cancers of the cervix do occur infrequently. In addition, HPV screening is not 100% sensitive for HPV-associated cervical cancer. Use of this device for primary cervical cancer screening should be undertaken after carefully considering the performance characteristics put forth in this label, as well as recommendations of professional guidelines.The use of this test has not been evaluated for the management of women with prior ablative or excisional therapy, or who are pregnant, or below age 21, or for the management of transgender individuals.
-
-