 Class 3 Device Recall T/Pumpsee related information
Date Initiated by FirmNovember 07, 2017
Date PostedMarch 14, 2018
Recall Status1 Terminated 3 on April 09, 2019
Recall NumberZ-1013-2018
Recall Event ID 79302
510(K)NumberK073675 
Product Classification Pack, hot or cold, water circulating - Product Code ILO
ProductT/Pump temperature therapy pump, Models TP700 and TP700C
Code Information TP700CI51006  TP700CI51013  TP700A61786  TP700A61803  TP700A61810  TP700A61754  TP700A61794  TP700A61802  TP700A61808  TP700A61811  TP700A61822  TP700B61158  TP700B61018  TP700B61033  TP700B61121  TP700B61122  TP700B61128  TP700B61131  TP700B61133  TP700B61134  TP700B61135  TP700B61139  TP700B61140  TP700B61142  TP700B61145  TP700B61146  TP700B61152  TP700B61162  TP700CH51109  TP700CH51116  TP700CI51002  TP700A61807  TP700A61792  TP700A61804  TP700A61813  TP700A61814  TP700A61815  TP700A61821  TP700A61823  TP700A61824  TP700A61829  TP700A61831  TP700A61837  TP700A61839  TP700A61842  TP700A61844  TP700CH51108  TP700A61654  TP700A61695  TP700A61696  TP700A61697  TP700A61700  TP700A61702  TP700A61704  TP700A61798  TP700A61817  TP700A61819  TP700A61820  TP700A61827  TP700A61828  TP700A61830  TP700A61832  TP700A61834  TP700A61835  TP700A61840  TP700A61699  TP700A61701  TP700A61720  TP700A61723  TP700A61731  TP700A61733  TP700C61078  TP700C61308  TP700C61316  TP700C61504  TP700C61546  TP700C61548  TP700C61549  TP700C61552  TP700C61570  TP700C61582  TP700C61592  TP700C61611  TP700C61615  TP700C61617  TP700A61655  TP700A61657  TP700A61669  TP700A61671  TP700A61672  TP700A61673  TP700A61687  TP700A61694  TP700A61703  TP700A61705  TP700A61706  TP700A61707  TP700A61708  TP700A61709  TP700A61710  TP700A61711  TP700A61712  TP700A61715  TP700A61718  TP700A61719  TP700A61722  TP700C61116  TP700C61126  TP700C61131  TP700C61141  TP700C61145  TP700C61182  TP700C61532  TP700C61543  TP700C61551  TP700C61571  TP700C61610  TP700C61620  TP700C61572  TP700C61583  TP700C61584  TP700C61590  TP700C61591  TP700C61594  TP700C61595  TP700C61601  TP700C61602  TP700C61603  TP700C61606  TP700C61607  TP700C61613  TP700C61614  TP700C61622  TP700C61121  TP700C61122  TP700C61132  TP700C61134  TP700C61139  TP700C61149  TP700C61152  TP700C61101  TP700C61123  TP700C61125  TP700C61127  TP700C61128  TP700C61130  TP700C61140  TP700C61142  TP700C61150  TP700C61151  TP700C61110  TP700C61113  TP700C61118  TP700C61144  TP700C61146  TP700C61147  TP700C61148  TP700C61171  TP700C61172  TP700C61173  TP700C61183  TP700C61184  TP700C61186  TP700CH51095  TP700CH51107  TP700CH51118  TP700CI51015  TP700CI51035  TP700CI51038  TP700C61345  TP700C61332  TP700C61342  TP700C61344  TP700C61353  TP700C61358  TP700C61366  TP700C61372  TP700C61378  TP700C61380  TP700C61387  TP700C61389  TP700C61390  TP700C61391  TP700C61553  TP700C61559  TP700C61577  TP700C61578  TP700C61179  TP700C61185  TP700C61188  TP700C61190  TP700C61357  TP700C61363  TP700C61368  TP700C61369  TP700C61370  TP700C61371  TP700C61373  TP700C61374  TP700C61375  TP700C61377  TP700C61379  TP700C61382  TP700C61384  TP700C61386  TP700C61388  TP700C61511  TP700C61155  TP700C61159  TP700C61162  TP700C61163  TP700C61165  TP700C61166  TP700C61167  TP700C61174  TP700C61192  TP700C61223  TP700C61229  TP700C61193  TP700C61194  TP700C61222  TP700C61225  TP700C61228  TP700CH51087  TP700CH51088  TP700CH51089  TP700CH51092  TP700CH51097  TP700CH51117  TP700CI51001  TP700CI51003  TP700CI51039  TP700CI51040  TP700C61153  TP700C61154  TP700C61156  TP700C61157  TP700C61160  TP700C61161  TP700C61168  TP700C61169  TP700C61170  TP700C61175  TP700C61176  TP700C61180  TP700C61181  TP700C61189  TP700C61164  TP700CI51042  TP700C61425  TP700C61430  TP700C61434  TP700C61440  TP700C61445  TP700C61446  TP700C61448  TP700C61453  TP700C61454  TP700C61455  TP700C61529  TP700C61077  TP700C61082  TP700C61087  TP700C61088  TP700C61096  TP700C61100  TP700C61102  TP700C61104  TP700C61105  TP700C61111  TP700C61112  TP700C61114  TP700C61115  TP700C61117  TP700C61119  TP700C61120  TP700C61136  TP700CH51086  TP700CH51093  TP700CH51098  TP700C61423  TP700C61424  TP700C61429  TP700C61408  TP700C61414  TP700C61415  TP700C61433  TP700C61444  TP700C61449  TP700C61437  TP700C61580  TP700C61045  TP700C61046  TP700C61047  TP700C61065  TP700C61067  TP700C61070  TP700C61071  TP700C61072  TP700C61075  TP700C61076  TP700C61079  TP700C61084  TP700C61086  TP700C61090  TP700C61092  TP700C61093  TP700C61094  TP700C61098  TP700C61099  TP700C61103  TP700CH51066  TP700CH51091  TP700CH51099  TP700CH51113  TP700CH51119  TP700CI51033  TP700C61063  TP700C61074  TP700C61081  TP700C61091  TP700C61042  TP700C61043  TP700C61044  TP700C61048  TP700C61049  TP700C61050  TP700C61051  TP700C61052  TP700C61054  TP700C61055  TP700C61056  TP700C61058  TP700C61061  TP700C61062  TP700C61064  TP700C61066  TP700C61068  TP700C61080  TP700C61085  TP700CH51063  TP700C61327  TP700C61328  TP700C61330  TP700C61333  TP700C61337  TP700C61338  TP700C61343  TP700C61346  TP700C61347  TP700C61350  TP700C61351  TP700C61352  TP700C61354  TP700C61355  TP700C61356  TP700C61360  TP700C61361  TP700C61362  TP700C61364  TP700C61365  TP700C61383  TP700C61376  TP700C61505  TP700C61547  TP700C61334  TP700C61335  TP700C61340  TP700C61341  TP700C61348  TP700C61517  TP700C61534  TP700C61538  TP700C61539  TP700C61540  TP700C61541  TP700C61544  TP700C61641  TP700C61633  TP700C61644  TP700C61649  TP700C61651  TP700C61657  TP700C61664  TP700C61667  TP700C61669  TP700C61671  TP700C61675  TP700C61678  TP700C61679  TP700C61680  TP700C61681  TP700C61690  TP700C61059  TP700C61095  TP700CH51074  TP700CH51076  TP700CH51079  TP700CH51094  TP700CH51103  TP700CI51030  TP700C61639  TP700C61640  TP700C61642  TP700C61643  TP700C61653  TP700C61663  TP700C61666  TP700C61442  TP700C61472  TP700C61488  TP700C61490  TP700C61491  TP700C61494  TP700C61497  TP700C61630  TP700C61634  TP700C61635  TP700C61636  TP700C61646  TP700C61647  TP700C61648  TP700C61650  TP700C61652  TP700C61655  TP700C61656  TP700C61658  TP700C61660  TP700C61662  TP700C61672  TP700C61030  TP700C61040  TP700C61041  TP700CI51005  TP700C61399  TP700C61447  TP700C61450  TP700C61458  TP700C61478  TP700C61480  TP700C61482  TP700C61483  TP700C61486  TP700C61487  TP700C61489  TP700C61492  TP700C61493  TP700C61495  TP700C61496  TP700C61498  TP700C61499  TP700C61500  TP700C61527  TP700C61536  TP700C61629  TP700C61631  TP700C61632  TP700C61637  TP700C61638  TP700C61659  TP700C61665  TP700C61026  TP700C61031  TP700C61034  TP700C61036  TP700C61038  TP700CH51062  TP700CH51096  TP700C61526  TP700C61021  TP700C61024  TP700C61025  TP700C61027  TP700C61028  TP700C61029  TP700C61032  TP700C61033  TP700C61035  TP700C61016  TP700C61019  TP700C61020  TP700C61017  TP700C61018  TP700C61008  TP700C61009  TP700C61010  TP700C61011  TP700C61012  TP700C61013  TP700C61014  TP700C61015  TP700C61201  TP700C61212  TP700C61218  TP700C61230  TP700C61238  TP700C61242  TP700C61004  TP700C61005  TP700C61006  TP700C61007  TP700C61460  TP700C61463  TP700C61464  TP700C61465  TP700C61466  TP700C61467  TP700C61468  TP700C61470  TP700C61471  TP700C61473  TP700C61474  TP700C61475  TP700C61476  TP700C61479  TP700C61484  TP700C61485  TP700C61535  TP700C61537  TP700C61177  TP700C61187  TP700C61191  TP700C61195  TP700C61196  TP700C61197  TP700C61198  TP700C61199  TP700C61200  TP700C61203  TP700C61204  TP700C61205  TP700C61206  TP700C61207  TP700C61208  TP700C61210  TP700C61214  TP700C61215  TP700C61216  TP700C61217  TP700C61219  TP700C61220  TP700C61221  TP700C61224  TP700C61226  TP700CH51090  TP700CI51014  TP700C61287  TP700C61234  TP700C61236  TP700C61251  TP700C61259  TP700C61301  TP700C61305  TP700C61307  TP700C61309  TP700C61359  TP700C61403  TP700C61413  TP700C61417  TP700C61418  TP700C61421  TP700C61427  TP700C61428  TP700C61432  TP700C61435  TP700C61436  TP700C61438  TP700C61443  TP700C61457  TP700C61459  TP700C61461  TP700C61462  TP700C61469  TP700C61598  TP700C61609  TP700C61596  TP700C61597  TP700C61599  TP700C61600  TP700C61608  TP700C61625  TP700C61060  TP700C61158  TP700C61292  TP700C61294  TP700C61296  TP700C61297  TP700C61303  TP700C61311  TP700C61312  TP700C61314  TP700C61315  TP700C61322  TP700C61385  TP700C61395  TP700C61398  TP700C61404  TP700C61406  TP700C61409  TP700C61420  TP700C61558  TP700C61589  TP700C61604  TP700C61605  TP700C61616  TP700C61618  TP700C61619  TP700C61621  TP700C61624  TP700C61626  TP700CH51067  TP700CH51068  TP700CH51069  TP700CH51070  TP700CH51072  TP700CH51073  TP700CH51075  TP700CH51077  TP700CH51100  TP700CH51102  TP700CH51104  TP700CH51105  TP700CI51007  TP700CI51016  TP700CI51034  TP700C61381  TP700C61394  TP700C61396  TP700C61397  TP700C61402  TP700C61555  TP700C61561  TP700C61562  TP700C61563  TP700C61566  TP700C61568  TP700C61573  TP700C61576  TP700C61579  TP700C61587  TP700C61673  TP700C61699  TP700C61704  TP700C61707  TP700C61708  TP700C61740  TP700C61694  TP700C61698  TP700C61750  TP700CD61005  TP700CD61006  TP700C61073  TP700CD61031  TP700CD61038  TP700CD61039  TP700CD61048  TP700CD61056  TP700CD61057  TP700CD61058  TP700CD61060  TP700CD61063  TP700CD61065  TP700CD61073  TP700CD61074  TP700C61143  TP700CH51064  TP700CH51065  TP700CH51071  TP700CH51078  TP700CI51021  TP700CI51049  TP700C61331  TP700C61336  TP700C61339  TP700C61349  TP700C61393  TP700C61401  TP700C61506  TP700C61510  TP700C61515  TP700C61519  TP700C61520  TP700C61523  TP700C61528  TP700C61530  TP700C61531  TP700C61533  TP700C61556  TP700C61557  TP700C61564  TP700C61567  TP700C61586  TP700C61588  TP700C61612  TP700C61670  TP700C61674  TP700C61676  TP700C61677  TP700C61682  TP700C61683  TP700C61684  TP700C61685  TP700C61686  TP700C61687  TP700C61688  TP700C61689  TP700C61692  TP700C61693  TP700C61695  TP700C61696  TP700C61697  TP700C61700  TP700C61702  TP700C61705  TP700C61715  TP700C61722  TP700C61736  TP700C61737  TP700C61742  TP700C61745  TP700C61746  TP700CD61072  TP700C61211  TP700C61227  TP700C61231  TP700C61232  TP700C61233  TP700C61235  TP700C61237  TP700C61244  TP700C61248  TP700C61249  TP700C61250  TP700C61254  TP700C61255  TP700C61256  TP700C61257  TP700C61258  TP700C61261  TP700C61262  TP700C61264  TP700C61268  TP700C61277  TP700C61279  TP700C61299  TP700C61304  TP700C61318  TP700C61508  TP700C61514  TP700C61569  TP700C61002  TP700C61003  TP700CD61054  TP700CD61069  TP700C61280  TP700C61247  TP700C61266  TP700C61267  TP700C61269  TP700C61273  TP700C61274  TP700C61275  TP700C61502  TP700C61503  TP700C61507  TP700C61512  TP700C61513  TP700C61524  TP700C61550  TP700C61554  TP700C61565  TP700C61585  TP700C61593  TP700B61239  TP700CD61032  TP700C61501  TP700CD61036  TP700CD61046  TP700CD61053  TP700CD61055  TP700CD61059  TP700CD61061  TP700CD61062  TP700CD61064  TP700CD61068  TP700CD61071  TP700C61270  TP700C61278  TP700B61215  TP700B61218  TP700B61220  TP700B61221  TP700B61222  TP700B61223  TP700B61224  TP700B61225  TP700B61226  TP700B61227  TP700B61229  TP700B61230  TP700B61231  TP700B61232  TP700B61233  TP700B61234  TP700B61235  TP700B61237  TP700CD61004  TP700CD61025  TP700CD61027  TP700CD61029  TP700CD61035  TP700CD61037  TP700CD61043  TP700CD61047  TP700CD61049  TP700CD61051  TP700CD61052  TP700CD61066  TP700CD61070  TP700B61219  TP700B61228  TP700B61213  TP700B61217  TP700CD61014  TP700CD61017  TP700CD61024  TP700C61241  TP700C61243  TP700C61276  TP700C61282  TP700C61286  TP700C61289  TP700C61291  TP700C61293  TP700C61313  TP700C61323  TP700C61324  TP700B61205  TP700B61206  TP700B61207  TP700B61208  TP700B61209  TP700B61210  TP700B61212  TP700B61214  TP700B61216  TP700C61252  TP700C61260  TP700C61288  TP700C61321  TP700CD61013  TP700CD61020  TP700CD61021  TP700CD61023  TP700CD61026  TP700CD61028  TP700CD61041  TP700C61202  TP700C61240  TP700C61263  TP700C61271  TP700C61281  TP700C61283  TP700C61285  TP700C61290  TP700C61310  TP700C61317  TP700C61319  TP700C61623  TP700C61272  TP700C61284  TP700C61295  TP700C61298  TP700C61300  TP700C61302  TP700C61320  TP700C61933  TP700C61935  TP700C61953  TP700C61955  TP700C61957  TP700C61960  TP700C61942  TP700C61940  TP700C61944  TP700C61946  TP700C61948  TP700C61951  TP700C61956  TP700C61958  TP700C61961  TP700CD61042  TP700C61941  TP700C61943  TP700C61952  TP700C61966  TP700D61146  TP700D61190  TP700D61214  TP700D61241  TP700C61950  TP700C61954  TP700C61934  TP700C61945  TP700C61949  TP700C61968  TP700C61976  TP700C61978  TP700C61981  TP700C61985  TP700C61988  TP700C61962  TP700C61963  TP700C61967  TP700C61970  TP700C61971  TP700CD61012  TP700CD61010  TP700D61128  TP700CD61034  TP700CD61040  TP700CD61044  TP700CD61045  TP700CD61050  TP700D61171  TP700D61178  TP700D61179  TP700D61182  TP700D61183  TP700D61187  TP700D61188  TP700D61189  TP700D61192  TP700D61194  TP700D61195  TP700D61196  TP700D61197  TP700D61198  TP700D61199  TP700D61202  TP700D61203  TP700D61204  TP700D61205  TP700D61208  TP700D61209  TP700D61212  TP700D61224  TP700D61228  TP700D61229  TP700D61235  TP700D61236  TP700D61256  TP700D61264  TP700D61265  TP700C61832  TP700C61833  TP700C61837  TP700C61838  TP700C61841  TP700C61842  TP700C61843  TP700C61844  TP700C61845  TP700C61846  TP700C61848  TP700C61852  TP700C61853  TP700C61854  TP700C61855  TP700C61856  TP700C61857  TP700C61858  TP700C61863  TP700C61864  TP700C61865  TP700C61866  TP700C61869  TP700C61870  TP700C61871  TP700C61926  TP700C61928  TP700C61931  TP700C61932  TP700C61936  TP700C61937  TP700C61939  TP700C61947  TP700C61964  TP700D61065  TP700D61191  TP700D61273  TP700D61287  TP700D61298  TP700D61314  TP700D61316  TP700D61323  TP700D61324  TP700D61326  TP700D61327  TP700D61328  TP700D61330  TP700D61332  TP700D61336  TP700D61340  TP700D61345  TP700D61348  TP700D61361  TP700C61836  TP700C61840  TP700D61231  TP700D61306  TP700D61344  TP700D61097  TP700D61107  TP700D61110  TP700D61111  TP700D61135  TP700D61136  TP700D61285  TP700D61304  TP700D61307  TP700D61310  TP700D61311  TP700D61312  TP700D61317  TP700D61319  TP700D61321  TP700D61322  TP700D61325  TP700D61329  TP700D61333  TP700D61084  TP700D61091  TP700CD61009  TP700D61101  TP700D61105  TP700D61051  TP700D61086  TP700D61089  TP700CD61003  TP700CD61022  TP700D61092  TP700D61098  TP700D61099  TP700D61100  TP700D61145  TP700CD61033  TP700D61222  TP700D61223  TP700D61226  TP700D61227  TP700D61237  TP700D61239  TP700D61240  TP700D61246  TP700D61252  TP700D61253  TP700D61255  TP700D61257  TP700D61260  TP700D61261  TP700D61274  TP700D61278  TP700D61280  TP700D61281  TP700C61835  TP700D61073  TP700D61082  TP700D61093  TP700D61095  TP700D61096  TP700D61103  TP700D61133  TP700D61134  TP700D61258  TP700C61849  TP700D61028  TP700D61083  TP700D61088  TP700D61262  TP700C61959  TP700D61018  TP700D61021  TP700D61022  TP700D61023  TP700D61024  TP700D61035  TP700D61037  TP700C61879  TP700C61887  TP700C61901  TP700C61906  TP700C61910  TP700C61911  TP700C61913  TP700C61917  TP700C61919  TP700C61921  TP700C61924  TP700C61989  TP700D61016  TP700D61017  TP700D61020  TP700C61880  TP700C61878  TP700C61884  TP700C61886  TP700C61888  TP700C61889  TP700C61907  TP700C61908  TP700C61909  TP700C61912  TP700C61914  TP700C61915  TP700C61920  TP700D61050  TP700D61055  TP700D61063  TP700D61068  TP700D61069  TP700D61070  TP700D61071  TP700D61077  TP700D61078  TP700D61079  TP700D61080  TP700D61081  TP700D61113  TP700D61102  TP700D61106  TP700D61118  TP700D61120  TP700D61122  TP700D61125  TP700D61131  TP700D61132  TP700D61139  TP700D61144  TP700D61150  TP700D61154  TP700D61158  TP700D61159  TP700D61160  TP700D61162  TP700CD61030  TP700D61164  TP700D61167  TP700D61168  TP700D61169  TP700D61170  TP700D61176  TP700D61180  TP700D61268  TP700D61277  TP700D61284  TP700D61288  TP700D61289  TP700D61290  TP700D61295  TP700C61923  TP700D61025  TP700D61030  TP700D61032  TP700D61034  TP700D61039  TP700D61040  TP700D61041  TP700D61042  TP700D61043  TP700D61049  TP700D61053  TP700D61056  TP700D61058  TP700D61060  TP700D61061  TP700D61062  TP700D61064  TP700D61066  TP700D61067  TP700D61072  TP700D61074  TP700D61075  TP700D61076  TP700D61121  TP700D61126  TP700D61157  TP700D61166  TP700C61A16  TP700D61112  TP700D61115  TP700D61117  TP700C61834  TP700C61875  TP700C61876  TP700C61877  TP700C61895  TP700C61897  TP700C61972  TP700D61087  TP700CD61007  TP700CD61008  TP700CD61011  TP700CD61015  TP700CD61016  TP700CD61019  TP700C61039  TP700C61083  201600103  201600104  201600105  201600108  201600115  201600116  201600117  201600119  201600120  201600121  TP700C61716  TP700C61717  TP700C61721  TP700C61723  TP700C61725  TP700C61732  TP700C61733  TP700C61735  TP700C61738  TP700C61739  TP700C61743  TP700C61747  TP700C61749  TP700C61862  TP700C61867  TP700C61874  TP700B61238  TP700C61037  TP700C61053  201600089  201600100  201600101  201600088  201600090  201600091  201600093  201600094  201600096  201600097  201600098  201600099  201600111  201600112  201600118  201600122  TP700C61525  TP700C61726  TP700C61729  TP700C61731  TP700C61860  TP700C61883  TP700C61893  TP700C61987  TP700B61236  TP700C61A09  TP700C61A11  TP700C61A15  TP700C61A18  TP700C61A22  TP700C61A28  TP700C61A30  TP700C61A31  TP700CH51011  TP700CH51002  TP700CH51003  TP700CH51007  TP700CH51008  TP700CH51010  TP700CH51018  TP700CH51025  TP700CH51026  TP700CH51031  TP700CH51032  201600102  201600109  201600110  TP700C61661  TP700C61709  TP700C61710  TP700C61712  TP700C61713  TP700C61718  TP700C61719  TP700C61720  TP700C61724  TP700C61818  TP700C61825  TP700C61A19  201600092  201600095  201600106  201600107  201600113  201600114  201600123  TP700C61811  TP700C61815  TP700C61816  TP700C61824  TP700C61827  TP700C61859  TP700C61872  TP700C61873  TP700C61894  TP700C61896  TP700C61898  TP700C61899  TP700C61900  TP700C61902  TP700C61903  TP700C61904  TP700C61905  TP700C61A17  TP700C61A21  TP700C61A24  TP700C61A25  TP700C61A27  TP700C61A29  TP700C61808  TP700C61809  TP700C61810  TP700C61812  TP700C61813  TP700C61814  TP700C61819  TP700C61820  TP700C61821  TP700C61826  TP700D61296  TP700D61294  TP700C61400  TP700C61581  TP700C61645  TP700C61701  TP700C61801  TP700C61806  TP700C61776  TP700C61798  TP700C61799  TP700C61800  TP700C61807  TP700C61817  TP700C61823  TP700D61052  TP700CH51004  TP700CH51005  TP700CH51006  TP700CH51009  TP700CH51012  TP700CH51013  TP700CH51014  TP700CH51015  TP700CH51016  TP700CH51017  TP700CH51019  TP700CH51020  TP700CH51021  TP700CH51022  TP700CH51023  TP700CH51024  TP700CH51027  TP700CH51028  TP700CH51029  TP700CH51030  TP700CH51033  TP700CH51034  TP700CH51035  TP700CH51036  TP700CH51037  TP700C61509  TP700C61545  TP700C61668  TP700C61691  TP700C61734  TP700C61766  TP700C61769  TP700C61772  TP700C61773  TP700C61778  TP700C61779  TP700C61786  TP700C61788  TP700C61789  TP700C61791  TP700C61795  TP700C61797  TP700C61802  TP700C61803  TP700C61804  TP700D61147  TP700D61155  TP700D61172  TP700D61173  TP700D61174  TP700D61200  TP700D61206  TP700D61210  TP700D61216  TP700D61217  TP700D61218  TP700C61703  TP700C61787  TP700C61790  TP700C61792  TP700C61805  TP700D61059  TP700CB61126  TP700CB61134  TP700D61109  TP700D61138  TP700D61142  TP700D61143  TP700D61148  TP700D61149  TP700D61151  TP700D61152  TP700D61153  TP700D61156  TP700D61219  TP700D61165  TP700D61175  TP700D61177  TP700D61181  TP700D61184  TP700D61185  TP700D61186  TP700D61193  TP700D61201  TP700D61207  TP700D61211  TP700D61215  TP700D61220  TP700D61291  TP700D61300  TP700D61387  TP700D61392  TP700D61394  TP700D61398  TP700D61399  TP700D61400  TP700D61401  TP700D61402  TP700D61404  TP700D61405  TP700D61408  TP700D61085  TP700D61247  TP700D61282  TP700D61389  TP700D61374  TP700D61377  TP700D61379  TP700D61383  TP700D61386  TP700D61390  TP700D61393  TP700D61395  TP700D61396  TP700D61403  TP700D61406  TP700D61407  TP700C61851  TP700D61355  TP700D61373  TP700D61375  TP700D61381  TP700D61384  TP700D61388  TP700D61391  TP700D61397  TP700D61299  TP700D61302  TP700D61341  TP700D61351  TP700D61353  TP700D61354  TP700D61358  TP700D61380  TP700D61385  TP700CB61115  TP700D61270  TP700D61276  TP700D61286  TP700D61293  TP700D61305  TP700D61331  TP700D61342  TP700D61347  TP700D61350  TP700D61356  TP700D61359  TP700D61360  TP700D61362  TP700D61378  TP700D61382  TP700D61320  TP700D61339  TP700D61346  TP700D61357  TP700C61890  TP700C61891  TP700C61892  TP700C61922  TP700C61916  TP700C61918  TP700C61925  TP700C61929  TP700C61930  TP700D61005  TP700D61009  TP700D61010  TP700D61002  TP700D61003  TP700D61004  TP700D61006  TP700D61007  TP700D61008  TP700D61011  TP700D61014  TP700D61019  TP700D61047  TP700D61057  TP700D61046  TP700D61048  TP700D61054  TP700CB61116  TP700CB61117  TP700CB61118  TP700CB61120  TP700CB61121  TP700CB61122  TP700CB61123  TP700CB61124  TP700CB61125  TP700CB61129  TP700CB61130  TP700CB61131  TP700CB61132  TP700CB61133  TP700CB61135  TP700CB61136  TP700CB61138  TP700CB61139  TP700CB61144  TP700CB61147  TP700C61A04  TP700C61A05  TP700C61A06  TP700C61A08  TP700C61A10  TP700C61A13  TP700C61A26  TP700CB61119  TP700CB61127  TP700CB61128  TP700CB61137  TP700CB61140  TP700CB61141  TP700CB61142  TP700CB61143  TP700CB61145  TP700CB61146  TP700CB61148  TP700CB61149  TP700CB61150  TP700D61141  TP700D61349  201601432  201601449  201601453  201601454  201601458  201601463  TP700C61828  TP700C61927  TP700C61938  TP700C61999  TP700C61973  TP700C61974  TP700C61975  TP700C61977  TP700C61979  TP700C61980  TP700C61982  TP700C61984  TP700C61990  TP700C61991  TP700C61992  TP700C61996  TP700C61997  TP700C61998  TP700D61015  TP700C61A03  TP700C61A00  TP700C61A01  TP700D61026  TP700D61027  TP700D61029  TP700D61031  TP700D61033  TP700D61036  TP700D61038  TP700D61104  TP700D61119  TP700D61221  TP700D61225  TP700D61233  TP700D61234  TP700D61243  TP700D61244  TP700D61245  TP700D61249  TP700D61250  TP700D61259  TP700D61271  TP700D61275  TP700D61283  TP700D61309  TP700D61313  TP700D61318  TP700D61334  TP700D61335  TP700D61337  TP700D61338  201601442  201601448  TP700C61751  TP700C61753  TP700C61758  TP700C61764  TP700C61770  TP700C61780  TP700C61781  TP700C61783  TP700C61A07  TP700C61A14  TP700C61A20  TP700D61123  TP700D61230  TP700D61232  TP700D61238  TP700D61242  TP700D61248  TP700D61266  TP700D61267  TP700D61269  TP700D61272  TP700D61292  TP700D61297  TP700D61301  TP700D61303  TP700D61352  TP700C61329  201601434  201601440  201601452  201601461  TP700C61754  TP700C61757  TP700C61762  TP700C61763  TP700C61765  TP700C61768  TP700C61771  TP700C61775  TP700C61777  TP700C61782  TP700C61784  TP700C61993  TP700C61A23  201601433  201601445  201601447  201601450  201601460  TP700C61706  TP700C61714  TP700C61741  TP700C61744  TP700C61748  TP700C61752  TP700C61756  TP700C61759  TP700C61760  TP700C61761  201600470  201600506  201600511  201600518  TP700C61767  TP700C61774  TP700C61785  TP700C61796  201600530  201600536  201600538  201600540  201600541  201600543  201600544  201600549  201600550  201600552  201600558  201601431  201601441  201601451  201601455  201601457  201601462  TP700C61755  201600523  201600531  201600533  201600539  201600542  201600545  201600546  201600547  201600548  201600551  201600554  201600555  201600556  201600559  TP700C61A02  201600184  201600193  201600166  201600173  201600175  201600177  201600178  201600179  201600180  201600181  201600182  201600183  201600186  201600187  201600188  201600190  201600191  201600192  201600196  201600198  201600199  201600201  201600202  201600203  201601436  201601437  201601438  201601439  201601443  201601446  201601456  201601459  201600527  201600532  201600534  201600537  201600553  201600557  201600015  201600019  201600021  201600025  201600026  201600029  201600040  201600041  201600161  201600163  201600165  201600168  201600169  201600170  201600171  201600172  201600176  201600012  201600014  201600016  201600017  201600018  201600020  201600022  201600023  201600024  201600027  201600028  201600030  201600031  201600032  201600033  201600034  201600035  201600036  201600037  201600038  201600039  201600042  201600043  201600044  201600045  201600046  201600011  201600013  201600330  201600341  201600167  201600213  201600217  201600220  201600221  201600223  201600226  201600230  201600233  201600308  201600309  201600311  201600316  201600317  201600318  201600321  201600322  201600338  201601435  TP700CF51092  TP700CF51114  TP700CF51119  TP700CF51123  TP700CF51132  TP700CF51140  TP700CF51141  TP700CF51144  TP700CF51148  201600148  201600151  201600194  201600195  201600204  201600205  201600206  201600208  201600209  201600210  201600211  201600212  201600214  201600215  201600216  201600218  201600219  201600222  201600225  201600227  201600228  201600229  201600231  201600232  201600234  201600305  201600310  201600312  201600313  201600314  201600315  201600319  201600320  201600323  201600324  201600325  201600326  201600327  201600328  201600329  201600331  201600332  201600333  201600334  201600335  201600336  201600337  201600339  201600340  201600342  201601428  201601429  201601430  201601444  201600588  201600586  201600587  201600590  201600591  201600595  201600599  201600601  201600606  201600612  201600616  201600617  201600618  201600622  201600623  201600624  201600625  201600626  201600627  201600631  201600632  201600633  201600634  201600224  201600260  201600261  201600263  201600273  201600274  201600276  201600278  201600279  201600280  201600281  201600282  201600283  201600284  201600285  201600286  201600287  201600288  201600289  201600290  201600291  201600292  201600293  201600294  201600295  201600296  201600297  201600298  201600299  201600300  201600301  201600302  201600303  201600304  201600306  201600307  201600344  201600348  201600367  201600560  201600561  201600562  201600563  201600564  201600565  201600566  201600567  201600568  201600569  201600570  201600571  201600572  201600573  201600574  201600575  201600576  201600577  201600578  201600579  201600580  201600581  201600582  201600583  201600584  201600585  201600589  201600592  201600593  201600594  201600596  201600597  201600598  201600600  201600602  201600603  201600604  201600605  201600607  201600608  201600609  201600610  201600613  201600614  201600615  201600619  201600620  201600621  TP700CF51091  TP700CF51131  201600275  201600391  201600379  201600387  201600390  201600396  201600397  201600343  201600345  201600346  201600349  201600350  201600352  201600354  201600355  201600359  201600360  201600361  201600374  201600377  201600380  201600381  201600382  201600383  201600384  201600385  201600386  201600388  201600389  201600394  201600395  201600398  201600399  TP700CE51012  TP700CE51013  TP700CF51004  TP700CF51010  TP700CF51045  TP700CF51046  TP700CF51047  TP700CF51048  TP700CF51050  TP700CF51052  TP700CF51053  TP700CF51054  TP700CF51055  TP700CF51057  TP700CF51058  TP700CF51060  TP700CF51061  TP700CF51062  TP700CF51063  TP700CF51064  TP700CF51067  TP700CF51069  TP700CF51070  TP700CF51071  TP700CF51072  TP700CF51073  TP700CF51074  TP700CF51075  TP700CF51077  TP700CF51080  TP700CF51085  TP700CF51086  TP700CF51095  TP700CF51101  TP700CF51102  TP700CF51103  TP700CF51104  TP700CF51105  TP700CF51106  TP700CF51107  TP700CF51109  TP700CF51110  TP700CF51111  TP700CF51112  TP700CF51113  TP700CF51117  TP700CF51120  TP700CF51122  TP700CF51126  TP700CF51129  TP700CF51130  TP700CF51133  TP700CF51134  TP700CF51135  TP700CF51137  TP700CF51138  TP700CF51139  TP700CF51142  TP700CF51143  TP700CF51145  TP700CF51146  TP700CF51147  TP700CF51149  TP700CF51152  201600357  201600458  201600472  201600476  201600480  201600484  201600485  201600451  201600454  201600459  201600498  201600467  201600469  201600474  201600475  201600478  201600496  TP700CF51049  TP700CF51125  201600269  201600243  201600255  201600262  201600264  201600271  201600277  201600453  201600455  201600456  201600460  201600461  201600464  201600465  TP700CF51083  TP700CF51084  TP700CF51128  201600134  201600136  201600139  201600144  201600146  201600147  201600150  201600156  201600157  201600158  201600159  201600160  201600174  201600142  201600145  201600258  201600266  201600270  201600462  TP700CF51056  TP700CF51059  TP700CF51065  TP700CF51068  TP700CF51078  TP700CF51079  TP700CF51081  TP700CF51090  TP700CF51093  TP700CF51094  TP700CF51096  TP700CF51098  TP700CF51099  TP700CF51100  TP700CF51116  TP700CF51118  TP700CF51121  TP700CF51124  TP700CF51127  TP700CF51136  TP700CF51150  201600135  201600133  201600138  201600140  201600143  201600149  201600452  201600457  201600466  201600468  201600471  201600473  201600477  201600486  201600492  201600497  201600499  TP700CF51066  TP700CF51076  TP700CF51088  TP700CF51097  201600141  201600127  201600128  201600130  201600131  201600153  201600162  201600164  201600185  201600235  201600236  201600237  201600238  201600239  201600240  201600241  201600242  201600244  201600245  201600246  201600247  201600248  201600249  201600250  201600251  201600252  201600253  201600254  201600256  201600257  201600259  201600265  201600267  201600268  TP700CF51082  201600479  201600502  201600490  201600500  201600504  201600505  201600508  201600509  201600510  201600512  201600513  201600514  201600517  201600521  201600524  201600525  201600526  201600528  201600529  TP700CF51087  TP700CF51089  TP700CJ41046  TP700CJ41051  TP700CJ41052  TP700CJ41059  201600137  201600154  201600155  201600373  201600378  201600401  201600402  201600403  201600404  201600405  201600406  201600408  201600410  201600411  201600412  201600413  201600414  201600415  201600416  201600417  201600419  201600420  201600421  201600423  201600424  201600425  201600426  201600430  201600434  201600436  201600440  201600444  201600446  201600447  201600448  201600449  201600495  201600482  201600487  201600503  201600507  201600515  201600520  201600407  201600409  201600422  201600428  201600432  201600433  201600437  201600438  201600441  201600442  201600443  201600445  201600450  TP700CJ41044  201600347  201600353  201600356  201600362  201600363  201600364  201600365  201600366  201600368  201600369  201600372  201600376  201600392  201600400  201600418  201600427  201600429  201600431  201600435  TP700K51382  201600072  201600075  201600076  201600077  201600083  201600358  201600351  201600370  201600371  201600375  201600481  201600483  201600489  201600491  201600493  201600494  201600501  201600516  201600519  201600535  201600056  201600057  201600060  201600061  201600062  201600064  201600065  201600066  201600067  201600068  201600069  201600071  201600073  201600074  201600078  201600080  201600081  201600082  201600084  201600842  201600847  201600823  201600824  201600877  201600878  201600048  201600050  201600052  201600058  201600059  201600783  201600777  201600799  201600800  201600839  201600811  201600812  201600816  201600820  201600822  201600825  201600826  201600827  201600828  201600829  201600830  201600831  201600833  201600835  201600836  201600838  201600852  201600858  201600859  201600862  201600867  201600875  201601317  201601339  201601346  TP700CJ41063  TP700CJ41029  TP700CJ41042  TP700CJ41043  TP700CJ41047  TP700CJ41048  TP700CJ41050  TP700CJ41060  TP700CJ41082  TP700CJ41106  201600853  201600857  201600864  201601302  201601312  201601313  201601320  201601322  201601325  201601327  201601329  201601331  201601333  201601337  201601338  201601341  201601342  201601343  201601344  201601345  201601347  201601350  201601352  201601323  201601328  201601349  201601353  201601336  201601318  201601321  201601326  201601334  201601335  201601340  201601348  201601351  201600049  201600051  201600053  201600054  201600055  201600070  201600079  201600663  201600670  201600675  201600678  201600657  201600668  201600671  201600676  201600677  201600679  201600683  201600685  201600691  201600693  201600702  201600680  201600681  201600687  201600688  TP700CJ41049  TP700CJ41053  201600654  201600660  201600669  201600653  201600655  201600656  201600658  201600659  201600661  201600665  201600667  201600672  201600673  201600674  201600686  201600880  201600881  201600891  201600892  201600894  201600895  201600896  201600897  201600899  201600901  201600902  201600906  201600908  201600912  201600914  201600915  201600917  201600920  201600921  201600662  201600909  201600886  201600907  201600715  201600716  201600723  201600730  201600732  201600733  201600734  201600735  201600736  201600737  201600738  201600739  201600740  201600741  201600742  201600743  201600745  201600747  201600750  201600751  201600752  201600754  201600952  201601015  201601016  201601025  201601030  201601031  201601033  201601034  201601036  201601037  201601042  201601043  201601045  201601049  201601050  201601052  201601055  201601056  201601057  201601059  201601060  201601064  201601065  201601070  201601073  201601076  201601078  201601084  201601092  201600682  201600753  201600755  201600756  201600761  201600882  201600883  201600884  201600887  201600890  201600905  201600910  201600911  201600707  201600746  201600757  201600758  201600759  201600760  201600876  201600879  201600975  201601023  201601027  201601032  201601039  201601041  201601047  201601048  201601053  201601054  201601071  201601058  201601061  201601062  201601063  201601066  201601067  201601069  201601072  201601074  201601077  201601080  201601081  201601082  201601083  201601085  201601087  201601088  201601089  201601090  201601091  201601094  201601101  201601109  201601111  201601115  201601124  201601134  201601135  201601136  201601142  201600744  201600798  201600869  201600888  201600889  TP700CJ41085  201601068  201601086  201600772  201600832  201600834  201600837  201600841  201600845  201600848  201600849  201600850  201600851  201600854  201600855  201600856  201600863  201600865  201600868  201600874  TP700CJ41017  TP700CJ41030  TP700CJ41037  TP700CJ41040  TP700CJ41056  TP700CJ41075  TP700CJ41079  201600807  201600802  201600808  201600810  201600813  201600815  201600817  201600818  201600819  201600840  201600844  201600860  201600924  201600925  201600953  201600955  201600966  201600967  201600968  201600969  201600970  201600972  201600973  201600974  201600976  201600977  201600978  201600982  201600991  201600993  201600995  201600999  201601002  201601005  201601007  201600809  201600821  201600846  201600861  201600930  201600937  201600980  201600981  201600904  201600900  TP700CJ41015  TP700CJ41120  201600926  201600936  201600939  201600923  201600927  201600940  201600944  201600947  201600949  201600951  201600954  201600956  201600957  201600958  201600963  201600964  201600979  201600871  201600898  201600918  201600928  201600929  201600931  201600934  201600935  201600938  201600941  201600942  201600946  201600959  201600960  201600961  201600965  TP700CJ41021  TP700CJ41095  201600919  201600943  201600945  201600962  201602172  201602184  201602185  201602188  201602190  201602191  201602192  201602193  201602195  201601099  201601166  201601186  201601190  201601191  201601197  201601200  201601203  201601208  201601214  201601220  201601194  201601196  201600885  201600903  201602178  201600922  201601102  201601154  201601167  201601172  201601173  201601177  201601179  201601181  201601185  201600793  201600796  201601187  201601188  201601192  201601193  201601195  201601198  201601199  201601201  201601202  201601204  201601205  201601206  201601212  201600870  201600873  201600933  201600666  201600689  201600694  201600696  201600705  201600706  201600708  201600709  201600710  201600711  201600714  201600718  201600719  201600720  201600721  201600722  201600724  201600725  201600726  201600727  201600729  201600731  201600684  201600690  201600695  201600697  201600698  201600699  201600700  201600701  201600703  201600704  201600712  201600713  201600717  201600728  201600786  201600794  201600797  201600748  201600768  201600769  201600780  201600781  201600782  201600788  201600791  201600795  TP700CJ41078  TP700CJ41084  TP700CJ41086  TP700CJ41087  TP700CJ41091  TP700CK41288  TP700CK41301  201602159  201602164  201602165  201602166  201602167  201602168  201602169  201602170  201602171  201602173  201602174  201602175  201602176  201602177  201602179  201602180  201602181  201602182  201602183  201602187  201602189  201602194  201602196  201602198  201602199  201600771  201600776  201600778  201600779  201600787  201600789  201600792  201601093  201601100  201601103  201601104  201601110  201601117  201601123  201601125  201601127  201601128  201601131  201601133  201600784  201600749  201600765  201600767  201600790  201600801  201601252  201601254  201601271  201601273  201601283  201601286  201601295  201601307  201601253  201601255  201601256  201601257  201601258  201601259  201601260  201601261  201601262  201601263  201601264  201601265  201601266  201601267  201601268  201601269  201601270  201601272  201601274  201601275  201601276  201601277  201601278  201601279  201601280  201601281  201601282  201601284  201601285  201601287 201601288  201601289  201601290  201601291  201601292  201601293  201601294  201601296  201601297  201601298  201601299  201601300  201601301  201601303  201601304  201601305  201601306  201601308  201601309  201601310  201601311  201601314  201601315  201601319  201601324  201601330  201601332  201600439  201600913  201600948  201600971  201600988  201600950  201600985  201600986  201600987  201600998  201601004  201601006  201601008  201601010  201601012  201601018  201601021  201601026  201601028  201601035  201601040  201600989  201600990  201600992  201600994  201600996  201600997  201601001  201601003  201601009  201601011  201601013  201601014  201601017  201601019  201601020  201601024  201601029  201601038  201601044  201601046  201601051  201602394  201602405  201602408  201601075  201601079  201601096  201601097  201601098  201601105  201601106  201601107  201601108  201601112  201601113  201601114  201601116  201601118  201601119  201602362  201602380  201602382  201602406  201602412  201601129  201601143  201601178  201602426  201602428  201602432  201602440  201601121  201601122  201601126  201601130  201601132  201601138  201601140  201601141  201601144  201601145  201601146  201601147  201601148  201601149  201601150  201601151  201601152  201601153  201601155  201601156  201601157  201601158  201601159  201601160  201601161  201601162  201601165  201601168  201601169  201601170  201601171  201601174  201601175  201601176  201601180  201601182  201601183  201601184  201602421  201602422  201602425  201602427  201602433  201602444  201602471  201602474  201600766  201600763  201600764  201600773  201600774  201600775  201600785  201600804  201601210  201601227  201601238  201602490  201602491  201602493  201602495  201602500  201601189  201601209  201601211  201601215  201601217  201601218  201601222  201601223  201601224  201601225  201601226  201601230  201601231  201601232  201601233  201601234  201601235  201601236  201601239  201601240  201601241  201601242  201601243  201601244  201601245  201601246  201601247  201601248  201601249  201601251  201602485  201602486  201602487  201602488  201602492  201602494  201602496  201602504  TP700CK41271  TP700CK41283  201602409  201602472  201602598  201602643  201602645  201602625  201602641  201602646  201602649  201602650  201602654  201601137  201601139  201601216  201601219  201601221  201601228  201601229  201601237  201601250  201602644  201602639  201602596  201602599  201602602  201602603  201602605  201602606  201602607  201602608  201602617  201602621  201602624  201602627  201602628  201602629  201602631  201602633  201602635  201602636  201602637  201602638  201602640  201602642  201602648  TP700CJ41134  TP700CK41270  TP700CK41297  201602014  201602015  201602016  201602017  201602019  201602020  201602022  201602025  201602026  201602036  201602037  201602038  201602040  201602041  201602044  201602053  201602034  201602046  201602013  201602018  201602021  201602023  201602024  201602027  201602028  201602030  201602035  201602039  201602043  201602048  201602055  201602056  201602057  201602033  201602047  201602049  201602063  201602262  201602248  201602321  201602303  201602307  201602309  201602310  201602312  201602314  201602316  201602322  201602324  201602331  201602058  201602061  201602069  201602073  201602238  201602243  201602245  201602246  201602250  201602251  201602255  201602258  201602260  201602261  201602263  201602264  201602265  201602266  201602267  201602269  201602270  201602271  201602273  201602276  201602278  201602280  201602281  201602282  201602283  201602284  201602285  201602286  201602287  201602288  201602289  201602290  201602291  201602292  201602293  201602294  201602297  201602298  201602301  201602304  201602311  201602313  201602315  201602317  201602318  201602319  201602320  201602323  201602326  201602330  201602240  201602242  201602249  201602597  201602670  201602675  201602632  201602634  201602653  201602656  201602657  201602659  201602660  201602664  201602665  201602666  201602668  201602669  201602672  TP700CK41269  TP700CK41287  201602275  201602358  201602461  201602506  201602530  201602544  201602667  201602673  201602647  201602652  201602658  201602663  201602671  201602674  201602424  201602430  201602439  201602454  201602455  201602457  201602467  201602468  201602469  201602661  201602662  TP700CJ41014  TP700CJ41088  TP700CJ41121  TP700CK41266  TP700CK41274  TP700CK41279  TP700CK41280  TP700CK41284  TP700CK41296  TP700CK41300  2016022661  201602279  201602410  201602381  201602414  201602416  201602420  201602423  201602434  201602456  201602458  201602466  201602470  201602476  201602481  201602532  TP700CJ41066  TP700CJ41068  TP700CJ41113  TP700CK41264  TP700CK41265  TP700CK41286  201602415  201602431  201602418  201602419  201602447  201602448  201602459  201602460  201602462  201602463  201602464  201602465  201602475  201602477  201602479  201602480  201602483  201602484  201602391  201602407  201602411  201602429  201602437  201602438  201602441  201602445  201602446  201602450  201602451  201602452  201602482  TP700CJ41083  TP700CJ41093  TP700CK41267  TP700CK41272  TP700CK41278  TP700CK41281  TP700CK41298  201602398  201602399  201602401  201602402  201602403  201602404  201602417  201602435  201602436  201602443  201602453  201602473  201602549  201602550  201602551  201602552  201602561  201602562  201602565  201602566  201602573  201602574  201602576  201602578  201602211  201602212  201602790  201602791  201602804  201602808  201602393  201602395  201602396  201602397  201602400  201602542  201602543  201602570  201602547  201602548  201602553  201602554  201602555  201602556  201602557  201602558  201602559  201602564  201602567  201602568  201602569  201602572  201602575  201602580  201602586  201602587  201602593  201602594  201602600  201602601  201602609  201602611  201602612  201602614  201602616  201602618  201602619  201602620  201602622  201602623  201602219  2016022584  2016022604  201602521  201602537  201602538  201602540  201602541  201602545  201602546  201602560  201602563  201602571  201602577  201602579  201602581  201602582  201602583  201602585  201602588  201602589  201602590  201602592  201602595  201602613  201602615  201602029  201602032  201602239  201602241  201602244  201602259  201602071  201602074  201602076  201602081  201602252  201602253  201602256  201602257  201602789  201602796  201602060  201602064  201602489  201602499  201602501  201602511  201602512  201602513  201602514  201602516  201602525  201602526  201602527  201602528  201602529  201602531  201602533  201602539  201602008  201602031  201602042  201602045  201602050  201602051  201602054  201602059  201602062  201602065  201602066  201602067  201602068  201602070  201602215  201602216  201602218  201602072  201602075  201602077  201602078  201602079  201602080  201602371  201602384  201602385  201602387  201602522  201602497  201602498  201602502  201602503  201602507  201602508  201602509  201602510  201602515  201602517  201602518  201602519  201602520  201602523  201602524  201602534  201602535  201602536  201602807  201602373  201602356  201602370  201602383  201602386  201602964  201602973  201602980  201602981  201602982  201602983  201602986  201602987  201602988  201602989  201602990  201602991  201602992  201602993  201602994  201602995  201602996  201602997  201602998  201602999  201603000  201603001  201603002  201603005  201603008  201602809  201602295  201602296  201602300  201602333  201602334  201602336  201602337  201602339  201602340  201602342  201602345  201602348  201602350  201602352  201602369  201602389  201602390  201602354  201602355  201602357  201602359  201602360  201602361  201602363  201602364  201602365  201602366  201602367  201602368  201602372  201602374  201602375  201602376  201602377  201602378  201602379  201602388  201602392  201602969  201602971  201602972  201602976  201602977  201602984  201602985  201602800  201602630  201602876  201602975  201602978  201602699  201602680  201602752  201602754  201602756  201602840  201602755  201602757  201602758  201602759  201602760  201602761  201602765  201602766  201602768  201602769  201602784  201602785  201602864  201602867  201602875  201602877  201602505  201602739  201602762  201602763  201602764  201602829  201602831  201602833  201602837  201602838  201602839  201602841  201602842  201602874  201603004  201603021  201603036  201602738  201602879  201602884  201602885  201602909  201602912  201602913  201603013  201602979  201603003  201603006  201603007  201603009  201603010  201603011  201603012  201603014  201603015  201603016  201603017  201603018  201603019  201603020  201603022  201603023  201603024  201603025  201603026  201603027  201603028  201603029  201603030  201603031  201603032  201603033  201603034  201603035  201603037  201603038  201603039  201602052  201602254  201602268  201602272  201602274  201602810  201602818  201602299  201602302  201602305  201602306  201602308  201602325  201602327  201602328  201602329  201602332  201602335  201602338  201602341  201602343  201602344  201602346  201602347  201602349  201602351  201602861  201602687  201602866  201602868  201602873  201602878  201602882  201602883  201602886  201602887  201602890  201602891  201602893  201602895  201602896  201602897  201602901  201602902  201602903  201602904  201602905  201602906  201602907  201602908  201602217  201602801  201602805  201602812  201602814  201602817  201602862  201602863  201602865  201602869  201602871  201602880  201602889  201602894  201602898  201602899  201602900  201602910  201602914  201602916  201602920  201602921  201602922  201602924  201602925  201602926  201602927  201602928  201602929  201602930  201602931  201602932  201602934  201602935  201602936  201602937  201602822  201602798  201602813  201602819  201602779  201602860  201602888  201602892  201602911  201602915  201602917  201602918  201602919  201602933  201603098  201603101  201603104  201603116  201603117  201603126  201602795  201602815  201602820  201602821  201603040  201603041  201603042  201603043  201603044  201603046  201603047  201603048  201603049  201603050  201603051  201603052  201603053  201603054  201603055  201603056  201603057  201603058  201603059  201603060  201603061  201603062  201603063  201603064  201603065  201603066  201603067  201603068  201603069  201603071  201603072  201603073  201603074  201603075  201603076  201603077  201603078  201603079  201603080  201603081  201603082  201603083  201603084  201603085  201603087  201603089  201603090  201603091  201603092  201603093  201603094  201603095  201603096  201603097  201603099  201603100  201603102  201603105  201603106  201603107  201603108  201603110  201603120  201603124  201603125  201602870  201602939  201602944  201602957  201602962  201602965  201603045  201602712  201602767  201602770  201602967  201602968  201602938  201602940  201602941  201602942  201602943  201602945  201602946  201602947  201602949  201602950  201602951  201602952  201602953  201602954  201602955  201602956  201602958  201602959  201602960  201602961  201602963  201602966  201602970  201602974  201602794  201602749  201602777  201602847  201602774  201602775  201602776  201602780  201602781  201602843  201602844  201602845  201602846  201602848  201602849  201602850  201602851  201602852  201602853  201602854  201602855  201602856  201602857  201602858  201602859  201602948  201603133  201603141  201603147  201603148  201603155  201603159  201603186  201603187  201603189  201603192  201602773  201602778  201602782  201602783  201602827  201602828  201602830  201602832  201602834  201602835  201602836  201602872  201603070  201603113  201603118  201603132  201603139  201603140  201603143  201603146  201603150  201603151  201603152  201603154  201603156  201603157  201603164  201603166  201603168  201603169  201603170  201603173  201603176  201603177  201603178  201603185  201603191  201603199  201603214  201603103  201603121  201603149  201603153  201603207  201603171  201603179  201603201  201603202  201603204  201603206  201603209  201603210  201603212  201603215  201603216  201603217  201603218  201603219  201603220  201602221  201602227  201602234  201602788  201602792  201602797  201602799  201602802  201602803  201602806  201602811  201602824  201603165  201603109  201603123  201603128  201603129  201603131  201603134  201603136  201603142  201603158  201603160  201603161  201603162  201603163  201603167  201603195  201603172  201603174  201603180  201603181  201603182  201603183  201603184  201603188  201603190  201603196  201603198  201603200  201603203  201603205  201603208  201603211  201603213  201602232  201603122  201603127  201603135  201603137  201603175  201603193  201603197  201602200  201602202  201602206  201602228  201602229  201602230  201602231  201602793  201602823  201602723  201602731  201603086  201603119  201603138  201603144  201603145  201603111  201603112  201603114  201603115  201603130  201602204  201602209  201602214  201602677  201602679  201602689  201602690  201602696  201602697  201602698  201602700  201602703  201602704  201602705  201602706  201602707  201602708  201602709  201602710  201602711  201602713  201602714  201602715  201602716  201602717  201602719  201602720  201602721  201602724  201602725  201602726  201602727  201602728  201602729  201602730  201602732  201602733  201602734  201602735  201602736  201602737  201602740  201602741  201602742  201602743  201602744  201602745  201602746  201602747  201602748  201602750  201602751  201602753  201602771  201602772  201602205  201602693  201602694  201602701  201602718  201602722  201602201  201602208  201602233  201602691  201602702  201602683  201602692  2016009100223  2016009100235  2016009100236  2016009100237  2016009100240  2016009100241  2016009100244  2016009100245  2016009100247  2016009100250  2016009100251  2016009100255  2016009100256  2016009100257  2016009100258  2016009100259  2016009100261  2016009100267  2016009100268  2016009100269  2016009100270  2016009100272  2016009100275  2016009100276  2016009100281  2016009100282  2016009100284  2016009100286  2016009100288  2016009100290  2016009100291  201602197  201602203  201602207  201602213  201602223  201602676  201602678  201602681  201602682  201602684  201602685  201602686  201602688  201602695  2016009100252  2016009100271  2016009100274  2016009100277  2016009100278  201602210  201602220  201602222  201602225  201602226  2016009100180  2016009100158  2016009100171  2016009100173  2016009100174  2016009100175  2016009100177  2016009100178  2016009100179  2016009100183  2016009100184  2016009100186  2016009100188  2016009100196  2016009100187  2016009100189  2016009100190  2016009100191  2016009100192  2016009100193  2016009100194  2016009100195  2016009100198  2016009100200  2016009100207  2016009100208  2016009100210  2016009100214  2016009100222  201602881  2016009200017  2016009200026  2016009100161  2016009100170  2016009100172  2016009100201  2016009100204  2016009100220  2016009100238  2016009100182  2016009100203  2016009100209  2016009100212  2016009100215  2016009100217  2016009100218  2016009100224  2016009100225  2016009100226  2016009100228  2016009100229  2016009100230  2016009100231  2016009100233  2016009100242  2016009100243  2016009100246  2016009100262  2016009100263  2016009100264  2016009200021  2016009200025  2016009200031  2016009200041  201602224  2016009100067  2016009100069  2016009100075  2016009100079  2016009100080  2016009100081  2016009100082  2016009100085  2016009100087  2016009100092  2016009100095  2016009100123  2016009100124  2016009100125  2016009100128  2016009100129  2016009100130  2016009100131  2016009100132  2016009100133  2016009100134  2016009100135  2016009100136  2016009100137  2016009100138  2016009100139  2016009100141  2016009100142  2016009100143  2016009100144  2016009100146  2016009100147  2016009100148  2016009100154  2016009100155  2016009100156  2016009100157  2016009100160  2016009100162  2016009100163  2016009100164  2016009100165  2016009100166  2016009100168  2016009100169  2016009100197  2016009100199  2016009100213  2016009100216  2016009100219  2016009100221  2016009100227  2016009100232  2016009100249  2016009100304  2016009100411  2016009100417  2016009100421  2016009100430  2016009100444  2016009100452  2016009100453  2016009100454  2016009100455  2016009100456  2016009100457  2016009100458  2016009100459  2016009100460  2016009100462  2016009100463  2016009100467  2016009100469  2016009100470  2016009100472  2016009100473  2016009100475  2016009100476  2016009100477  2016009100478  2016009100479  2016009100481  2016009100486  2016009100487  2016009100490  2016009100491  2016009100492  2016009100493  2016009100496  2016009100499  2016009100045  2016009100061  2016009100063  2016009100064  2016009100070  2016009100072  2016009100073  2016009100074  2016009100076  2016009100077  2016009100083  2016009100176  2016009100181  2016009100185  2016009100202  2016009100205  2016009100211  2016009200020  2016009200024  2016009200033  2016009200046  2016009200047  2016009100028  2016009100029  2016009100030  2016009100031  2016009100032  2016009100033  2016009100034  2016009100036  2016009100039  2016009100041  2016009100042  2016009100043  2016009100044  2016009100048  2016009100049  2016009100050  2016009100051  2016009100052  2016009100053  2016009100054  2016009100055  2016009100057  2016009100059  2016009100060  2016009100062  2016009100065  2016009100066  2016009100068  2016009100078  2016009100084  2016009100086  2016009100088  2016009100089  2016009100090  2016009100091  2016009100094  2016009100302  2016009100311  2016009100313  2016009100314  2016009100315  2016009100316  2016009100035  2016009100037  2016009100038  2016009100040  2016009100046  2016009100047  2016009100056  2016009200012  2016009200018  2016009200022  2016009200027  2016009200029  2016009200037  2016009200040  2016009200042  2016009200044  2016009200045  201601930  201601974  201601979  201601986  201601989  201601993  201601994  201602003  201602004  201602005  201602006  201602007  201601484  201601504  201601507  201601511  201601522  201601532  201601541  201601543  201601544  201601545  201601547  201601851  201601840  201601848  201601854  201601856  201601857  201601859  201601860  201601861  201601865  201601871  201601878  201601971  201601992  201601505  201601519  201601520  201601523  201601525  201601527  201601528  201601542  201601546  201601548  201601551  2016009200028  2016009200035  201601962  201601970  201601972  201601978  201601981  201601982  201601983  201601984  201601985  201601987  201601988  201601991  201601995  201601996  201601997  201601998  201601999  201602000  201602001  201602002  201601498  201601517  201601526  201601539  201601540  201601524  201601529  201601535  201601536  201601537  201601538  201601554  201601555  201601706  201601708  201601709  201601720  201601726  201601727  201601729  201601690  201601698  201601704  201601711  201601714  201601715  201601717  201601719  201601724  201601801  201601808  201601826  201601829  201601830  201601831  201601836  201601837  201601839  201601841  201601843  201601844  201601845  201601846  201601847  201601850  201601853  201601862  201601864  201601867  201601872  201601881  201601653  201601678  201601712  201601723  201601681  201601684  201601691  201601718  201601721  201601368  201601362  201601363  201601365  201601366  201601369  201601370  201601371  201601372  201601377  201601379  201601384  201601385  201601386  201601654  201601658  201601672  201601682  201601687  201601688  201601689  201601692  201601694  201601697  201601716  201601722  201601354  201601355  201601356  201601357  201601360  201601367  201601373  201601374  201601378  201601380  201601388  201601389  2016009200013  2016009200014  2016009200015  2016009200016  2016009200019  2016009200023  2016009200030  2016009200032  2016009200034  2016009200036  2016009200038  2016009200039  201602157  201601358  201601359  201601361  201601364  201601375  201601381  201601382  201601383  201601387  201601398  201601399  201601400  201601401  201601402  201601404  201601405  201601407  201601409  201601410  201601411  201601414  201601416  201601417  201601419  201601421  201601423  201601391  201601394  201601390  201601392  201601393  201601396  201601397  201601403  201601406  201601408  201601412  201601415  201601422  201601424  201601467  201601469  201601470  201602096  201602136  201601395  201601413  201601489  201601580  201601562  201601588  201601595  201601599  201601600  201601602  201601614  201601619  201601621  201601626  201601852  201602118  201601516  201601561  201601574  201601584  201601586  201601587  201601590  201601593  201601596  201601598  201601601  201601603  201601604  201601605  201601609  201601612  201601616  201601617  201601618  201601620  201601623  201601624  201601627  201601630  201601631  201601632  201601634  201601635  201601636  201601637  201601638  201601641  201601644  201601645  201601669  201601674  201601676  201601677  201601553  201601570  201601582  201601597  201601606  201601607  201601608  201601610  201601611  201601613  201601615  201601628  201601639  201601640  201601642  201601643  201601646  201601576  201601778  201601747  201601751  201601754  201601757  201601759  201601762  201601765  201601766  201601768  201601769  201601770  201601771  201601772  201601773  201601774  201601775  201601777  201601780  201601785  201602101  201602119  201602120  201602121  201602124  201602129  201602131  201602132  201602134  201602135  201602137  201602138  201602139  201602140  201602141  201602144  201602146  201602150  201602151  201602152  201602153  201602154  201602155  201602156  201602158  201601572  201601648  201601671  201601679  201601685  201601696  201601752  201601756  201601760  201601761  201601763  201601764  201601767  201601776  201601789  201601792  201601793  201601794  201601795  201601796  201601797  201601656  201601662  201601668  201601699  201601703  201601779  201601592  201601622  201601647  201601649  201601650  201601651  201601652  201601655  201601657  201601659  201601660  201601661  201601663  201601664  201601665  201601666  201601667  201601670  201601673  201601675  201601680  201601738  201601743  201601693  201601695  201601701  201601702  201601705  201601713  201601725  201601739  201601742  201601744  201601748  201601749  201601750  201601753  201601758  201601783  201601784  201601787  201601842  201601858  201601863  201601866  201601868  201601870  201601873  201601874  201601875  201601876  201601877  201601879  201601880  201601882  201601883  201601884  201601885  201601886  201601887  201601889  201601891  201601892  201601893  201601894  201601895  201601896  201601897  201601898  201601899  201601901  201601902  201601904  201601906  201601907  201601908  201601911  201602143  201602145  201601534  201601550  201601557  201601566  201601568  201601573  201601581  201601583  201601686  201601700  201601707  201601710  201601728  201601730  201601731  201601732  201601733  201601734  201601735  201601736  201601737  201601740  201601741  201601745  201601746  201601781  201601782  201601503  201601510  201601514  201601515  201601518  201601521  201601530  201601531  201601533  201601549  201601552  201601556  201601558  201601559  201601560  201601563  201601564  201601565  201601567  201601569  201601571  201601575  201601577  201601578  201601579  201601585  201601589  201601629  201601800  201601806  201601807  201601809  201601810  201601812  201601813  201601815  201601816  201601817  201601818  201601819  201601820  201601821  201601822  201601823  201601824  201601825  201601828  201601786  201601788  201601790  201601791  201601798  201601799  201601802  201601803  201601804  201601805  201601814  201601811  201601827  201601832  201601833  201601835  201601849  201601936  201601973  201601949  201601950  201601952  201601953  201601955  201601956  201601957  201601958  201601959  201601960  201601961  201601963  201601964  201601965  201601966  201601967  201601968  201601969  201601975  201601976  201601977  201601980  201602133  201601499  201601500  201601506  201601513  201601838  201601939  201601940  201601942  201601943  201601944  201601945  201601946  201601947  201601948  201601951  201602142  201602148  201601493  201601468  201601471  201601472  201601473  201601477  201601480  201601482  201601483  201601485  201601486  201601487  201601488  201601491  201601492  201601494  201601495  201601496  201601497  201601501  201601502  201601508  201601509  201601512  201602147  201602098  201602149  201601420  201602116  201601475  201601478  201601479  201601481  201601633  201601903  201601909  201601912  201601913  201601914  201601915  201601916  201601917  201601918  201601919  201601920  201601921  201601922  201601923  201601924  201601925  201601926  201601927  201601928  201601929  201601931  201601932  201601933  201601934  201601935  201601937  201602092  201601938  201601941  201602093  201602094  201602099  201602103  201602104  201602105  201602106  201602107  201602108  201602109  201602110  201602111  201602112  201602113  201602114  201602115  201602117  201602122  201602123  201602125  201602126  201602127  201602130  2016009100353  2016009100416  2016009100425  2016009100431  2016009100434  2016009100435  2016009100436  2016009100438  2016009100441  2016009100451  2016009100461  2016009100464  2016009100465  2016009100466  2016009100468  2016009100471  2016009100480  2016009100482  2016009100483  2016009100485  2016009100488  2016009100489  2016009100494  2016009100495  2016009100497  2016009100498  201601855  201601869  201601888  201601890  201601900  201601905  201601910  201602087  201602088  201602089  201602090  201602091  201602100  2016009100107  201601418  201601474  201601476  2016009100150  2016009100433  2016009100420  2016009100423  2016009100426  2016009100432  2016009100437  2016009100442  2016009100445  2016009100447  2016009200081  2016009200097  201602095  201602097  201602102  2016009100097  2016009100098  2016009100100  2016009100102  2016009100108  2016009100109  2016009100110  2016009100111  2016009100113  2016009100114  2016009100116  2016009100122  2016009100126  2016009100127  2016009100145  2016009100151  2016009100153  2016009200058  2016009200075  2016009200083  2016009200084  2016009200090  2016009200091  2016009200105  2016009200106  2016009200107  2016009200111  2016009200112  2016009200113  2016009200114  2016009200115  2016009200116  2016009200117  2016009200118  2016009200120  2016009200121  2016009100104  2016009100106  2016009100112  2016009100118  2016009100119  2016009100121  2016009100152  2016009100140  2016009100159  206009200101  2016009100319  2016009200085  2016009200096  2016009200098  2016009200103  2016009100101  2016009100105  2016009100117  2016009100120  2016009100149  2016009100253  2016009100283  2016009100287  2016009100294  2016009100296  2016009100300  2016009100303  2016009100306  2016009100310  2016009100323  2016009100324  2016009100328  2016009100239  2016009100248  2016009100254  2016009100265  2016009100266  2016009100273  2016009100280  2016009100289  2016009100293  2016009100295  2016009100297  2016009100298  2016009100299  2016009100301  2016009100305  2016009100307  2016009100309  2016009100320  2016009100321  2016009100322  2016009100325  2016009100339  2016009100341  2016009100342  2016009100347  2016009100354  2016009100356  2016009100357  2016009100358  2016009100359  2016009100362  2016009100  2016009100093  2016009100096  2016009100103  2016009100115  2016009100260  2016009100279  2016009100326  2016009100327  2016009100334  2016009100335  2016009100340  2016009100343  2016009100344  2016009100345  2016009100361  2016009100364  2016009100365  2016009100367  2016009100292  2016009100333  2016009100396  2016009100410  2016009100413  2016009100414  2016009100428  2016009100429  2016009100450  2016009100285  2016009100308  2016009100318  2016009100329  2016009100337  2016009100346  2016009100348  2016009100350  2016009100372  2016009100373  2016009100376  2016009100380  2016009100387  2016009100407  2016009100443  2016009100384  2016009100386  2016009100388  2016009100390  2016009100392  2016009100393  2016009100398  2016009100400  2016009100409  2016009100412  2016009100415  2016009100419  2016009100422  2016009100424  2016009100439  2016009100440  2016009100446  2016009100449  2016009100448  2016009200053  2016009200059  2016009200065  2016009200066  2016009200070  2016009200072  2016009200076  2016009200077  2016009200093  2016009200094  2016009200095  2016009200102  2016009200104  2016009100099  2016009100381  2016009100330  2016009100331  2016009100332  2016009100338  2016009100355  2016009100360  2016009100363  2016009100366  2016009100368  2016009100369  2016009100370  2016009100371  2016009100374  2016009100375  2016009100377  2016009100378  2016009100379  2016009100382  2016009100385  2016009100383  2016009100389  2016009100391  2016009100394  2016009100395  2016009100397  2016009100399  2016009100401  2016009100402  2016009100403  2016009100404  2016009100405  2016009100406  2016009100854  2016009100873  2016009100874  2016009100875  2016009100877  2016009100880  2016009100885  2016009100887  2016009100888  2016009100889  2016009100891  2016009100892  2016009100893  2016009100896  2016009100898  2016009100900  2016009100901  2016009100902  2016009100903  2016009100904  2016009100905  2016009100907  2016009100908  2016009100968  2016009100911  2016009100913  2016009100914  2016009100944  2016009100947  2016009100952  2016009100958  2016009100960  2016009100969  2016009100970  2016009100971  2016009100973  2016009100974  2016009100977  2016009100985  2016009100986  2016009100988  2016009100989  2016009101053  2016009101065  2016009101067  2016009101071  2016009101075  2016009101078  2016009101081  2016009101082  2016009101091  2016009101094  2016009101098  2016009101099  2016009100720  2016009100819  2016009100870  2016009100915  2016009100953  2016009100956  2016009100957  2016009100961  2016009100962  2016009100963  2016009100965  2016009100966  2016009100967  2016009100983  2016009101074  2016009101097  2016009101013  2016009101086  2016009101090  2016009101093  2016009101095  2016009101096  2016009101051  2016009101062  2016009101073  2016009101077  2016009101088  2016009101092  2016009200074  2016009100658  2016009100729  2016009100732  2016009100734  2016009100736  2016009100737  2016009100738  2016009100741  2016009100742  2016009100743  2016009100744  2016009100752  2016009100756  2016009100759  2016009100760  2016009100761  2016009100764  2016009100766  2016009100768  2016009100772  2016009100782  2016009100625  2016009100626  2016009100654  2016009100727  2016009100728  2016009100730  2016009100733  2016009100747  2016009100750  2016009100751  2016009100754  2016009100755  2016009100757  2016009100758  2016009100765  2016009100586  2016009100593  2016009100595  2016009100613  2016009100618  2016009100624  2016009100627  2016009100997  2016009101017  2016009200067  2016009200079  2016009100560  2016009100568  2016009100575  2016009100577  2016009100579  2016009100580  2016009100583  2016009100584  2016009100585  2016009100587  2016009100589  2016009100590  2016009100591  2016009100594  2016009100596  2016009100597  2016009100598  2016009100600  2016009100601  2016009100602  2016009100603  2016009100606  2016009100607  2016009100615  2016009100619  2016009100623  2016009100682  2016009100812  2016009100951  2016009100955  2016009100991  2016009100984  2016009100990  2016009100992  2016009100993  2016009100995  2016009101001  2016009101003  2016009101006  2016009101007  2016009101008  2016009101011  2016009101014  2016009101015  2016009101016  2016009101018  2016009101019  2016009101021  2016009101023  2016009101024  2016009101026  2016009101030  2016009101031  2016009200055  2016009200057  2016009200062  2016009200063  2016009200069  2016009200092  2016009100673  2016009100674  2016009100678  2016009100707  2016009100987  2016009101004  2016009101009  2016009101010  2016009101020  2016009101025  2016009200050  2016009200051  2016009200052  2016009200056  2016009200061  2016009200068  2016009200073  2016009200078  2016009100546  2016009100551  2016009100553  2016009100565  2016009100570  2016009100572  2016009100573  2016009100574  2016009100581  2016009100582  2016009100622  2016009100640  2016009100675  2016009100676  2016009100677  2016009100680  2016009100681  2016009100683  2016009100684  2016009100685  2016009100686  2016009100687  2016009100688  2016009100690  2016009100691  2016009100692  2016009100693  2016009100694  2016009100695  2016009100696  2016009100699  2016009100700  2016009100701  2016009100702  2016009100703  2016009100705  2016009100706  2016009100710  2016009100714  2016009100716  2016009100718  2016009100722  2016009100726  2016009200054  2016009200082  2016009200099  2016009200100  2016009100559  2016009100561  2016009100562  2016009100563  2016009100569  2016009100576  2016009100578  2016009100672  2016009100689  2016009100745  2016009100769  2016009100770  2016009100771  2016009100776  2016009100778  2016009100779  2016009100780  2016009100781  2016009100783  2016009100784  2016009100785  2016009100787  2016009100789  2016009100792  2016009100794  2016009100800  2016009100802  2016009100807  2016009100808  2016009100520  2016009100535  2016009100536  2016009100541  2016009100543  2016009100544  2016009100545  2016009100547  2016009100548  2016009100549  2016009100550  2016009100554  2016009100555  2016009100556  2016009100557  2016009100558  2016009100564  2016009100566  2016009100571  2016009100639  2016009100667  2016009100668  2016009100670  2016009100763  2016009100721  2016009100725  2016009100753  2016009100767  2016009100777  2016009100786  2016009100796  2016009100806  2016009200087  2016009100632  2016009100647  2016009100653  2016009100662  2016009100698  2016009100740  2016009100746  2016009100748  2016009100774  2016009100775  2016009200064  2016009100534  2016009100621  2016009100629  2016009100638  2016009100646  2016009100652  2016009100656  2016009100657  2016009100659  2016009100665  2016009100669  2016009100679  2016009100704  2016009100708  2016009100709  2016009100713  2016009100715  2016009100723  2016009100731  2016009100739  2016009100427  2016009100474  2016009100515  2016009100517  2016009100519  2016009100525  2016009100526  2016009100529  2016009100530  2016009100532  2016009100533  2016009100500  2016009100501  2016009100502  2016009100503  2016009100504  2016009100505  2016009100506  2016009100508  2016009100509  2016009100510  2016009100511  2016009100513  2016009100514  2016009100518  2016009100521  2016009100522  2016009100523  2016009100524  2016009100527  2016009100528  2016009100531  2016009100552  2016009100711  2016009100712  2016009100717  2016009200080  2016009200089  2016009100823  2016009100824  2016009100825  2016009100829  2016009100830  2016009100836  2016009100843  2016009100853  2016009100857  2016009100858  2016009100859  2016009100862  2016009100863  2016009100865  2016009100866  2016009100867  2016009100868  2016009100869  2016009100871  2016009100872  2016009100876  2016009100878  2016009100879  2016009100881  2016009100882  2016009100883  2016009100886  2016009101085  2016009101114  2016009101126  2016009101133  2016009101141  2016009101147  2016009101155  2016009100828  2016009100833  2016009100837  2016009100840  2016009100846  2016009100847  2016009100848  2016009100849  2016009100852  2016009101043  2016009101045  2016009101072  2016009101089  2016009101103  2016009101107  2016009101108  2016009101109  2016009101111  2016009101113  2016009101120  2016009101121  2016009101122  2016009101123  2016009101125  2016009101127  2016009101128  2016009101131  2016009101132  2016009101138  2016009101139  2016009200165  2016009100815  2016009100851  2016009100856  2016009100860  2016009100999  2016009101037  2016009101052  2016009101069  2016009101080  2016009101105  2016009101112  2016009101115  2016009101117  2016009101119  2016009101124  2016009101129  2016009101130  2016009101134  2016009101135  2016009101140  2016009200140  2016009200141  2016009200145  2016009200149  2016009200151  2016009200153  2016009200164  2016009100724  2016009100821  2016009100788  2016009100790  2016009100791  2016009100793  2016009100795  2016009100797  2016009100801  2016009100803  2016009100804  2016009100805  2016009100810  2016009100811  2016009100813  2016009100814  2016009100816  2016009100817  2016009100818  2016009100820  2016009100822  2016009100826  2016009100827  2016009100831  2016009100834  2016009100835  2016009100838  2016009100839  2016009100841  2016009100842  2016009100850  2016009100855  2016009100861  2016009101100  2016009101137  2016009101142  2016009101143  2016009101148  2016009101151  2016009100567  20169101144  2016009100948  2016009100954  2016009100910  2016009100937  2016009100939  2016009100972  2016009100975  2016009100979  2016009100982  2016009101064  2016009101101  2016009101102  2016009101104  2016009101106  2016009101116  2016009101136  2016009101145  2016009101150  2016009101152  2016009101153  2016009101154  2016009100917  2016009100920  2016009100921  2016009100949  2016009100980  2016009101022  2016009200142  2016009100926  2016009100931  2016009100918  2016009100919  2016009100922  2016009100923  2016009100928  2016009100929  2016009100932  2016009100934  2016009100936  2016009100938  2016009100941  2016009100942  2016009100943  2016009100946  2016009100950  2016009101042  2016009101044  2016009101055  2016009101118  2016009101146  2016009101149  2016009200146  2016009100628  2016009100630  2016009100634  2016009100635  2016009100637  2016009100641  2016009100642  2016009100643  2016009100649  2016009100655  2016009100663  2016009100664  2016009100976  2016009101032  2016009101041  2016009101048  2016009101050  2016009101054  2016009101056  2016009101058  2016009101059  2016009101063  2016009100894  2016009101002  2016009101035  2016009101038  2016009101039  2016009101040  2016009101046  2016009101047  2016009101049  2016009101057  2016009200163  2016009100599  2016009100604  2016009100605  2016009100608  2016009100609  2016009100610  2016009100611  2016009100612  2016009100614  2016009100616  2016009100617  2016009100620  2016009100631  2016009100633  2016009100636  2016009100644  2016009100645  2016009100648  2016009100650  2016009100651  2016009100660  2016009100661  2016009100666  2016009100697  2016009100735  2016009100799  2016009100940  2016009100994  2016009100996  2016009100998  2016009101000  2016009101005  2016009101012  2016009101027  2016009101028  2016009101029  2016009101033  2016009101034  2016009101036  2016009101663  2016009101671  2016009101678  2016009200154  2016009200156  2016009101713  2016009101732  2016009101695  2016009101696  2016009101697  2016009101698  2016009101701  2016009101706  20160091017099  2016009101710  2016009101714  2016009101715  2016009101718  2016009101719  2016009101721  2016009101724  2016009101725  2016009101726  2016009101731  2016009101734  2016009101716  2016009101723  2016009101733  2016009101265  2016009101498  2016009101509  2016009101517  2016009101520  2016009101522  2016009101526  2016009101527  2016009101528  2016009101530  2016009101531  2016009101532  2016009101533  2016009101535  2016009101537  2016009101538  2016009101541  2016009101544  2016009101563  2016009101672  2016009101673  2016009101675  2016009200134  2016009200136  2016009200143  2016009200162  2016009101688  2016009101690  2016009101694  2016009101700  2016009101729  2016009101744  2016009101782  2016009101757  2016009101760  2016009101762  2016009101763  2016009101770  2016009101774  2016009101776  2016009101780  2016009101781  2016009101783  2016009101717  2016009101720  2016009101722  2016009101730  2016009101735  2016009101740  2016009101741  2016009101742  2016009101746  2016009101747  2016009101771  2016009101772  2016009101777  2016009101788  2016009101420  2016009101455  2016009101503  2016009101504  2016009101506  2016009101512  2016009101514  2016009101515  2016009101516  2016009101518  2016009101521  2016009101529  2016009101534  2016009101546  2016009101562  2016009101564  2016009101565  2016009101569  2016009101581  2016009101585  2016009101586  2016009101587  2016009101589  2016009101590  2016009101592  2016009101593  2016009101594  2016009101595  2016009101596  2016009101598  2016009101599  2016009101600  2016009101601  2016009101602  2016009101603  2016009101604  2016009101605  2016009101609  2016009101610  2016009101612  2016009101613  2016009101614  2016009101615  2016009101616  2016009101618  2016009101619  2016009101642  2016009101647  2016009101624  2016009101625  2016009101631  2016009101633  2016009101635  2016009101637  2016009101638  2016009101644  2016009101645  2016009101646  2016009101648  2016009101649  2016009101651  2016009011306  2016009101289  2016009101290  2016009101294  2016009101299  2016009101300  2016009101304  2016009101309  2016009101310  2016009101312  2016009101313  2016009101316  2016009101317  2016009101318  2016009101319  2016009101320  2016009101321  2016009101322  2016009101578  2016009101597  2016009101607  2016009101608  2016009101611  2016009101617  2016009101620  2016009101621  2016009101623  2016009101626  2016009101627  2016009101628  2016009101629  2016009101630  2016009101632  2016009101636  2016009101639  2016009101640  2016009101641  2016009101643  2016009101650  2016009101652  2016009101654  2016009101655  201600910166  2016009101743  2016009101750  2016009101755  2016009101756  2016009101758  2016009101765  2016009101766  2016009101775  2016009101778  2016009101784  2016009101288  2016009101291  2016009101292  2016009101295  2016009101296  2016009101297  2016009101298  2016009101303  2016009101305  2016009101307  2016009101311  2016009101315  2016009101416  2016009101421  2016009101422  2016009101432  2016009101446  2016009101513  2016009101259  2016009101252  2016009101254  2016009101255  2016009101263  2016009101264  2016009101273  2016009101278  2016009101284  2016009101287  2016009101293  2016009101301  2016009101302  2016009101314  2016009101402  2016009101410  2016009101411  2016009101413  2016009101414  2016009101415  2016009101417  2016009101418  2016009101419  2016009101425  2016009101426  2016009101428  2016009101429  2016009101430  2016009101431  2016009101434  2016009101436  2016009101437  2016009101438  2016009101439  2016009101442  2016009101450  2016009101459  2016009101479  2016009101485  2016009101502  2016009200130  2016009200131  2016009200132  2016009200133  2016009200135  2016009200137  2016009200138  2016009200139  2016009200144  2016009200147  2016009200148  2016009200150  2016009200152  2016009200155  2016009200157  2016009200158  2016009200159  2016009200160  2016009200161  2016009200168  2016009200169  2016009200172  2016009200173  2016009200176  2016009200178  2016009200198  2016009200199  2016009200182  2016009200183  2016009200185  2016009200186  2016009200188  2016009200189  2016009200190  2016009200191  2016009200193  2016009200195  2016009200196  2016009200200  2016009200201  2016009101468  2016009101469  2016009101488  2016009101492  2016009200170  2016009200184  2016009200187  2016009200192  2016009200194  2016009101466  2016009101487  2016009101491  2016009101494  2016009101505  2016009101452  2016009101457  2016009101461  2016009101462  2016009101481  2016009101486  2016009101489  2016009101495  2016009101496  2016009101497  2016009101500  2016009101501  2016009101508  2016009101511  2016009101653  2016009101659  2016009101667  2016009101669  2016009101670  2016009101702  2016009101703  2016009101705  2016009200179  2016009101661  2016009101665  2016009101685  2016009101656  2016009101658  2016009101662  2016009101666  2016009101668  2016009101674  2016009101679  2016009101687  201600901588  2016009101271  2016009101281  2016009101539  2016009101543  2016009101657  2016009101660  2016009101664  2016009101676  2016009101677  2016009101680  2016009101681  2016009101682  2016009101683  2016009101684  2016009101686  2016009101689  2016009101691  2016009101692  2016009101693  2016009101699  2016009101704  2016009101707  2016009101708  2016009101711  2016009101712  2016009101738  2016009101751  2016009101759  2016009101773  2016009101805  2016009101806  2016009101815  2016009101816  2016009101841  2016009101844  2016009101850  2016009101855  2016009101856  2016009101858  2016009101859  2016009101860  2016009101862  2016009101880  2016009101882  2016009101898  2016009101900  2016009200180  2016009101857  2016009101853  2016009101854  2016009101249  2016009101250  2016009101251  2016009101257  2016009101258  2016009101260  2016009101262  2016009101266  2016009101267  2016009101269  2016009101272  2016009101274  2016009101275  2016009101276  2016009101277  2016009101279  2016009101280  2016009101363  2016009101375  2016009101383  2016009101392  2016009101398  2016009101400  2016009101401  2016009101524  2016009101622  2016009200166  2016009200181  2016009101851  2016009101333  2016009101360  2016009101361  2016009101366  2016009101384  2016009101406  2016009101409  2016009200167  2016009200174  2016009200175  2016009200177  2016009101256  2016009101268  2016009101270  2016009101282  2016009101283  2016009101324  2016009101330  2016009101334  2016009101336  2016009101337  2016009101341  2016009101342  2016009101343  2016009101344  2016009101345  2016009101349  2016009101350  2016009101354  2016009101412  2016009101423  2016009101433  2016009101443  2016009101445  2016009101447  2016009101449  2016009101451  2016009101453  2016009101456  2016009101458  2016009101463  2016009101464  2016009101465  2016009101470  2016009101471  2016009101473  2016009101474  2016009101478  2016009101483  2016009101484  207009200255  2016009200171  2017009200242  2017009200243  2017009200251  2017009200252  2017009200260  2017009200266  2017009200267  2017009200268  2017009200270  2017009200271  2017009200272  2017009200274  2017009200275  2017009200279  2017009200282  2017009200283  2017009200284  2017009200285  2017009200286  2017009200287  2017009200288  2017009200289  2017009200290  2017009200291  2017009200292  2017009200293  2017009200294  2017009200295  2017009200296  2017009200297  2017009200298  2017009200299  2017009200300  2017009200301  2017009200302  2017009200303  2017009200304  2017009200305  2017009200306  2017009200307  2017009200308  2017009200309  2017009200310  2017009200311  2017009200312  2017009200313  2017009200314  2017009200315  2017009200316  2017009200317  2017009200318  2017009200319  2017009200320  2017009200321  2017009200322  2017009200323  2017009200324  2016009101328  2016009101329  2016009101331  2016009101347  2016009101351  2016009101358  2016009101346  2016009101348  2016009101355  2016009101357  2016009101335  2016009101359  2016009101374  2016009101376  2016009101377  2016009101378  2016009101381  2016009101390  2016009101393  2016009101394  2016009101395  2016009101397  2016009101399  2016009101405  2016009101407  2016009101253  2016009101369  2016009101370  2016009101387  2016009101389  2016009101396  TP700CJ41098  2017009200257  2017009200259  2017009200262  2017009200263  2017009200264  2017009200269  2017009200277  2017009200278  2017009200280  2017009200281  2016009101362  2016009101364  2016009101365  2016009101368  2016009101371  2016009101372  2016009101373  2016009101379  2016009101380  2016009101382  2016009101385  2016009101386  2016009101388  2016009101391  2016009101403  2016009101404  2016009101408  2016009101549  2017009200217  2017009200218  2017009200220  2017009200227  2017009200231  2017009200232  2017009200233  2017009200234  2017009200235  2017009200237  2017009200238  2017009200240  2017009200241  2017009200244  2017009200245  2017009200248  2017009200249  2017009200250  2017009200253  2017009200254  2017009200256  2017009200258  2016009101536  2016009101540  2016009101542  2016009101545  2016009101547  2016009101548  2016009101550  2016009101551  2016009101552  2016009101553  2016009101554  2016009101556  2016009101557  2016009101558  2016009101559  2016009101560  2016009101561  2016009101566  2016009101567  2016009101568  2016009101570  2016009101571  2016009101572  2016009101573  2016009101574  2016009101575  2016009101576  2016009101577  2016009101579  2016009101580  2016009101582  2016009101583  2016009101584  2016009101591  2017009200239  2016009101555  2016009101736  2016009101737  2016009101739  2016009101745  2016009101748  2016009101749  2016009101752  2016009101753  2016009101754  2016009101761  2016009101764  2016009101768  2016009101769  2016009101779  2016009101785  2016009101786  2016009101787  2016009101789  2016009101790  2016009101791  2016009101792  2016009101793  2016009101794  2016009101795  2016009101796  2016009101797  2016009101798  2016009101799  2016009101800  2016009101801  2016009101807  2016009101808  2016009101809  2016009101811  2016009101812  2016009101817  2017009200219  2017009200221  2017009200224  2017009200225  2017009200226  2017009200230  2017009102171  2017009102175  2017009102178  2017009102180  2017009102182  2017009200236  2017009200246  2017009200247  2017009102189  2017009200222  2017009200228  2017009200229  2017009102166  2017009102168  2017009102169  2017009102170  2017009102173  2017009102174  2017009102176  2017009102177  2017009102181  2017009102183  2017009102186  2017009102188  2017009102190  2017009102192  2017009102194  2017009102200  2017009200341  2017009200347  2017009200350  2017009200352  2017009200357  2017009200359  2017009200367  2017009200369  2017009200370  2017009200373  2017009200375  2017009200377  2017009200379  2017009200381  2017009200382  2017009200385  2017009200387  2017009200391  2017009200395  2017009200397  2017009200407  2017009102167  2017009102179  2017009102184  2017009102195  2017009012064  2017009102053  2017009102062  2017009102068  2017009102071  2017009102072  2017009102073  2017009102076  2017009102077  2017009102079  2017009102080  2017009102082  2017009102084  2017009102085  2017009102086  2017009102087  2017009102088  2017009102090  2017009102092  2017009102172  2017009102187  2017009102191  2017009102193  2017009102196  2017009102197  2017009102198  2017009102199  2017009102201  2017009102202  2017009102060  2017009102061  2017009102089  2019009101977  TP700K51479  2017009101931  2017009101934  2017009101943  2017009101945  2017009101946  2017009101956  2017009101957  2017009101958  2017009101959  2017009101960  2017009101961  2017009101962  2017009101963  2017009101964  2017009101965  2017009101966  2017009101968  2017009101969  2017009101971  2017009101978  2017009101979  2017009101980  2017009101982  2017009101983  2017009101984  2017009101986  2017009101987  2017009101988  2017009102059  2017009102052  2017009102057  2017009102063  2017009102066  2017009102067  2017009102069  2017009102074  2017009101915  2016009101802  2016009101804  2016009101810  2016009101813  2017009101949  2017009101967  2017009101973  2017009101976  2017009101981  2017009101985  2016009101826  2016009101834  2016009101818  2016009101819  2016009101820  2016009101821  2016009101823  2016009101824  2016009101825  2016009101827  2016009101828  2016009101829  2016009101830  2016009101831  2016009101832  2016009101833  2016009101835  2016009101836  2016009101837  2016009101838  2016009101839  2016009101840  2016009101842  2016009101843  2016009101845  2016009101846  2016009101847  2016009101848  2016009101849  2016009101852  2017009102000  2017009102002  2017009102003  2017009102004  2017009102008  2017009102011  2017009102014  2017009102015  2017009102017  2017009102018  2017009102019  2017009102020  2017009102021  2017009102023  2017009102028  2017009102034  2017009102036  2017009102037  2017009102038  2017009102039  2017009102040 2017009102041  2017009102042  2017009102043  2017009102044  2017009102045  2017009102046  2017009102047  2017009102048  2017009102049  2017009102050  2017009102051  2017009102054  2017009102055  2017009102056  2017009102058  2017009101916  2017009101917  2017009101918  2017009101919  2017009101920  2016009101803  2017009101921  2017009101922  2017009101923  2017009101924  2017009101926  2017009101927  2017009101928  2017009101929  2017009101932  2017009101933  2017009101935  2017009101936  2017009101937  2017009101940  2017009101941  2017009101942  2017009101944  2017009101947  2017009101948  2017009101950  2017009101951  2017009101952  2017009101953  2017009101954  2017009101955  2016009101861  2016009101881  2016009101883  2016009101884  2016009101899  2017009102128  2017009102134  2017009200374  2017009200398  2016009101814  2017009102101  2017009102102  2017009102106  2017009102108  2017009102109  2017009102110  2017009102113  2017009102116  2017009102117  2017009102119  2017009102121  2017009102122  2017009102123  2017009102125  2017009102126  2017009102136  2017009102137  2017009200349  2017009200366  2017009200389  2017009200394  2017009012135  2017009102096  2017009102107  2017009102094  2017009102097  2017009102100  2017009102103  2017009102104  2017009102105  2017009102112  2017009102114  2017009102115  2017009102129  2017009102098  2017009102099  2017009200434  2017009200439  2017009102075  2017009102083  2017009102120  2017009102146  2017009102152  2017009102124  2017009102127  2017009102138  2017009102139  2017009102143  2017009102147  2017009102150  2017009102151  2017009102153  2017009102154  2017009102155  2017009102156  2017009102161  2017009102162  2017009200355  2017009200368  2017009200372  2017009200393  2017009200396  2017009200402  2017009200404  2017009200405  2017009200406  2017009200408  2017009200410  2017009200413  2017009200421  2017009200422  2017009200423  2017009200424  2017009200426  2017009200428  2017009200429  2017009200431  2017009200432  2017009200435  2017009200437  2017009200440  2017009200441  2017009200443  2017009200444  2017009200445  2017009200446  2017009200448  2017009200450  2017009101992  2017009102141  2017009101925  2017009102013  2017009101991  2017009101994  2017009101995  2017009101999  2017009102005  2017009102007  2017009102010  2017009102016  2017009102022  2017009102025  2017009102026  2017009102027  2017009102029  2017009102030  2017009102031  2017009102032  2017009102033  2017009102035  2017009102095  2017009102118  2017009102130  2017009102131  2017009102132  2017009102133  2017009102140  2017009102142  2017009102144  2017009102145  2017009102148  2017009102149  2017009102157  2017009102158  2017009102159  2017009102160  2017009200442  2017009101930  2017009101975  2017009102012  2017009102024  2017009101989  2017009101990  2017009101996  2017009101997  2017009101998  2017009102006  2017009200345  2017009200416  2017009200430  2017009200433  2017009102401  2017009102402  2017009102407  2017009102409  2017009102410  2017009102411  2017009102413  2017009102414  2017009102415  2017009102417  2017009102418  2017009102419  201700920425  2017009101970  2017009101972  2017009101974  2017009101993  2017009102009  2017009102001  2017009102224  2017009102227  2017009102237  2017009102241  2017009102257  2017009102260  2017009102267  2017009102268  2017009102276  2017009102289  2017009200390  2017009200399  2017009200411  2017009200412  2017009200414  2017009200417  2017009200420  2017009200436  2017009102540  2017009102542  2017009102545  2017009102245  2017009200342  2017009102291  2017009200415  2017009200418  2017009200419  2017009102350  2017009102351  2017009102422  2017009102399  2017009102416  2017009102524  2017009102527  2017009102529  2017009102533  2017009102547  2017009102543  2017009102544  2017009102546  2017009102239  2017009102311  2017009102341  2017009102368  2017009102403  2017009102424  2017009102469  2017009102530  2017009102531  2017009102548  2017009102549  2017009102552  2017009200400  2017009200409  2017009102348  2017009200464  2017009200468  2017009200483  2017009200484  2017009200490  2017009200492  2017009200495  2017009200496  2017009200500  2017009200501  2017009102400  2017009102405  2017009102406  2017009102408  2017009102423  2017009102431  2017009102435  2017009102436  2017009102457  2017009102460  2017009102463  2017009102466  2017009102468  2017009102472  2017009102473  2017009102474  2017009102475  2017009102476  2017009102487  2017009102528  2017009102536  2017009102220  2017009102221  2017009102222  2017009102225  2017009102226  2017009102228  2017009102229  2017009102230  2017009102231  2017009102232  2017009102233  2017009102234  2017009102235  2017009102236  2017009102238  2017009102240  2017009102242  2017009102243  2017009102244  2017009102248  2017009102249  2017009102250  2017009102251  2017009102253  2017009102254  2017009102256  2017009102258  2017009102259  2017009102261  2017009102262  2017009102263  2017009102264  2017009102265  2017009102266  2017009102269  2017009102270  2017009102271  2017009102273  2017009102274  2017009102277  2017009102280  2017009102281  2017009102282  2017009102292  2017009102293  2017009102294  2017009102357  2017009102427  2017009102433  2017009102451  2017009102452  2017009102456  2017009102461  2017009102465  2017009102467  2017009102470  2017009102471  2017009102477  2017009102478  2017009102481  2017009102485  2017009102488  2017009102412  2017009102425  2017009102426  2017009102428  2017009102429  2017009102430  2017009102432  2017009102434  2017009102437  2017009102438  2017009102439  2017009102440  2017009102441  2017009102443  2017009102444  2017009102446  2017009102447  2017009102448  2017009102449  2017009102450  2017009102453  2017009102455  2017009102458  2017009102459  2017009102462  2017009102464  2017009102523  2017009102525  2017009102526  2017009102532  2017009102541  2017009102550  2017009102551  2017009102223  2017009102285  2017009102297  2017009102328  2017009102362  2017009102374  2017009102396  2017009200469  2017009200488  2017009200489  2017009200499  2017009102535  2017009102312  2017009102318  2017009102319  2017009102330  2017009102354  2017009102335  2017009102336  2017009102339  2017009102340  2017009102342  2017009102347  2017009102352  2017009102353  2017009102358  2017009102377  2017009102394  2017009102395  2017009102397  2017009102313  2017009102315  2017009102316  2017009102317  2017009102337  2017009102344  2017009102345  2017009102346  2017009102359  2017009102375  2017009102376  2017009200455  2017009200456  2017009200458  2017009200480  2017009200494  2017009102322  2017009102323  2017009102246  2017009102284  2017009102288  2017009102304  2017009102307  2017009102320  2017009102325  2017009102338  2017009102343  2017009102247  2017009102296  2017009102300  2017009102303  2017009102308  2017009102324  2017009102327  2017009102329  2017009102275  2017009102301  2017009102333  2017009102355  2017009102356  2017009200467  2017009200479  2017009200526  2017009200537  2017009200539  2017009200540  2017009200541  2017009200557  2017009200563  2017009102290  2017009102305  2017009102306  2017009102309  2017009102310  2017009102331  2017009102332  2017009102334  2017009200457  2017009200459  2017009200461  2017009200462  2017009200463  2017009200465  2017009200470  2017009200471  2017009200473  2017009200474  2017009200475  2017009200476  2017009200477  2017009200478  2017009200481  2017009200482  2017009200485  2017009200487  2017009200533  2017009102255  2017009102286  2017009102287  2017009102272  2017009102279  2017009102283  2017009102295  2017009102298  2017009102299  2017009102302  2017009102326  2017009102393  2017009200466  2017009102314  2017009102321  2017009102349  2017009102364  2017009102366  2017009102369  2017009102370  2017009102373  2017009102379  2017009102380  2017009102382  2017009102388  2017009102390  2017009102391  2017009102392  2017009102404  2017009102445  2017009102454  2017009102491  2017009102497  2017009102499  2017009102500  2017009102501  2017009102504  2017009102506  2017009102508  2017009102509  2017009102510  2017009102513  2017009102515  2017009102517  2017009102538  2017009102539  2017009102361  2017009102365  2017009102367  2017009102371  2017009102372  2017009102383  2017009102384  2017009102385  2017009102387  2017009102389  2017009200493  2017009200503  2017009102442  2017009102479  2017009102480  2017009102482  2017009102483  2017009102484  2017009102486  2017009102490  2017009102492  2017009102494  2017009102496  2017009102498  2017009102502  2017009102503  2017009102505  2017009102507  2017009102511  2017009102512  2017009102514  2017009102516  2017009102574  2017009102584  2017009102586  2017009102592  2017009102597  2017009102604  2017009102607  2017009102618  2017009102640  2017009102645  2017009102648  2017009102652  2017009102663  2017009102669  2017009102678  2017009102679  2017009102386  2017009102573  2017009102594  2017009102595  2017009102602  2017009102608  2017009102646  2017009102629  2017009102634  2017009102643  2017009102644  2017009102647  2017009102650  2017009102651  2017009102654  2017009102661  2017009102662  2017009102664  2017009102666  2017009102676  2017009200486  2017009102489  2017009102537  2017009102642  2017009102694  2017009102715  2017009102716  2017009102717  2017009102718  2017009102719  2017009102722  2017009102723  2017009102725  2017009102726  2017009102727  2017009102728  2017009102729  2017009102730  2017009102731  2017009102732  2017009102733  2017009102735  2017009102736  2017009102737  2017009102738  2017009102739  2017009102741  2017009102743  2017009102745  2017009102746  2017009102748  2017009102752  2017009102753  2017009102756  2017009102758  2017009102764  2017009102767  2017009102768  2017009102769  2017009102360  2017009102363  2017009102378  2017009102381  2017009200522  2017009200523  2017009200534  2017009200538  2017009200553  2017009200561  2017009102724  2017009102749  2017009102814  2017009102833  2017009102835  2017009102838  2017009102839  2017009102841  2017009102843  2017009102847  2017009102849  2017009102850  2017009102851  2017009102852  2017009102854  2017009102855  2017009102856  2017009102857  2017009102859  2017009102862  2017009102865  2017009102869  2017009102872  2017009102882  2017009102883  2017009102884  2017009102885  2017009102888  2017009200460  2017009200505  2017009102790  2017009102793  2017009102826  2017009102842  2017009102866  2017009102845  2017009102853  2017009102858  2017009102860  2017009102873  2017009102874  2017009102876  2017009102878  2017009102879  2017009102880  2017009102894  2017009102895  2017009102898  2017009102899  2017009102901  2017009102902  2017009102905  2017009102911  2017009102912  2017009102913  2017009102915  2017009102918  2017009102919  2017009102920  2017009102921  2017009102924  2017009102925  2017009102926  2017009102928  2017009102929  2017009102930  2017009102568  2017009102582  2017009102587  2017009102591  2017009102605  2017009102621  2017009102625  2017009102626  2017009102649  2017009102655  2017009102656  2017009102657  2017009102658  2017009102660  2017009102665  2017009102667  2017009102670  2017009102673  2017009102674  2017009102861  2017009102863  2017009102870  2017009102887  2017009102891  2017009102893  2017009102922  2017009102927  2017009102616  2017009102672  2017009200531  2017009200536  2017009200555  2017009200562  2017009102576  2017009102588  2017009102606  2017009102611  2017009102624  2017009102653  2017009102659  2017009102668  2017009102671  2017009102675  2017009200497  2017009102585  2017009102589  2017009102622  2017009102583  2017009102623  2017009102786  2017009102788  2017009102803  2017009102810  2017009102821  2017009102822  2017009102827  2017009102829  2017009102720  2017009102740  2017009102742  2017009102775  2017009102776  2017009102791  2017009102794  2017009102798  2017009102801  2017009102804  2017009102806  2017009102808  2017009102809  2017009102811  2017009102813  2017009102815  2017009102816  2017009102818  2017009102819  2017009102820  2017009102823  2017009102824  2017009102825  2017009102828  2017009102832  2017009102834  2017009102840  2017009102844  2017009102848  2017009102868  2017009102877  2017009102881  2017009102886  2017009102890  2017009102897  2017009102904  2017009102914  2017009102916  2017009102917  2017009102923  2017009102931  2017009102932  2017009102933  2017009102934  2017009102935  2017009102937  2017009102938  2017009102940  2017009200528  2017009200535  2017009200548  2017009200560  2017009102619  2017009102755  2017009102762  2017009102763  2017009102765  2017009102766  2017009102771  2017009102772  2017009102774  2017009102777  2017009102778  2017009102781  2017009102782  2017009102784  2017009102785  2017009102789  2017009102792  2017009102797  2017009102836  2017009102846  2017009102864  2017009102867  2017009102871  2017009102875  2017009102889  2017009102892  2017009102896  2017009102903  2017009102936  2017009102939  2017009200504  2017009200506  2017009200508  2017009200516  2017009102744  2017009102750  2017009102761  2017009102770  2017009102787  2017009102795  2017009102796  2017009102830  2017009102837  2017009102747  2017009102751  2017009102754  2017009102757  2017009102759  2017009102783  2017009102575  2017009102680  2017009102681  2017009102682  2017009102683  2017009102684  2017009102685  2017009102686  2017009102688  2017009102689  2017009102690  2017009102691  2017009102692  2017009102693  2017009102695  2017009102696  2017009102697  2017009102698  2017009102699  2017009102700  2017009102701  2017009102702  2017009102703  2017009102704  2017009102705  2017009102706  2017009102707  2017009102708  2017009102710  2017009102714  2017009102721  2017009102773  2017009102760  2017009102779  2017009102780  2017009102569  2017009102570  2017009102571  2017009102596  2017009102598  2017009102599  2017009102600  2017009102603  2017009102609  2017009102610  2017009102612  2017009102613  2017009102614  2017009102615  2017009102617  2017009102620  2017009102627  2017009102628  2017009102630  2017009102631  2017009102632  2017009102633  2017009102635  2017009102636  2017009102637  2017009102638  2017009102639  2017009102641  2017009102687  2017009102709  2017009102711  2017009102712  2017009102713  2017009200521  2017009102577  2017009102578  2017009102579  2017009102580  2017009102581  2017009102590  2017009102593  2017009102601  2017009102805  2017009102807  2017009102812  2017009102831  2017009103013  2017009200514  2017009102980  2017009103001  2017009103015  2017009103016  2017009103019  2017009103022  2017009103027  2017009103028  2017009103029  2017009103030  2017009103033  2017009103035  2017009103047  2017009103048  2017009103066  2017009103068  2017009103073  2017009102983  2017009103005  2017009103017  2017009103023  2017009103025  2017009103026  2017009200545  2017009102998  2017009103038  2017009103042  2017009103079  2017009200507  2017009200511  2017009200512  2017009102943  2017009102948  2017009102954  2017009102957  2017009102965  2017009102999  2017009103000  2017009103007  2017009103031  2017009103032  2017009103034  2017009103074  2017009103269  2017009103303  2017009103305  2017009103310  2017009102910  2017009102945  2017009102946  2017009102951  2017009102976  2017009103111  2017009103268  2017009103293  2017009103304  2017009103307  2017009103308  2017009103309  2017009102817  2017009102942  2017009102944  2017009102950  2017009102952  2017009102994  2017009103006  2017009103021  2017009103160  2017009103249  2017009103250  2017009103222  2017009103231  2017009103240  2017009103241  2017009103243  2017009103245  2017009103248  2017009103252  2017009103253  2017009103254  2017009103255  2017009103256  2017009103259  2017009103261  2017009103262  2017009103263  2017009103267  2017009103294  2017009103296  2017009103297  2017009103299  2017009103306  2017009200554  2017009103172  2017009103226  2017009103227  2017009103233  2017009103235  2017009103236  2017009103237  2017009103247  2017009103251  2017009103257  2017009103258  2017009103264  2017009103266  2017009103224  2017009103239  2017009200525  2017009200527  2017009200529  2017009200530  2017009200542  2017009103232  2017009103242  2017009200513  2017009200517  2017009200519  2017009200544  2017009200547  2017009200550  2017009200551  2017009103181  2017009103189  2017009103198  2017009103201  2017009103203  2017009103207  2017009103208  2017009103209  2017009103218  2017009103210  2017009103211  2017009103212  2017009103213  2017009103214  2017009103215  2017009103216  2017009103217  2017009103219  2017009103221  2017009103223  2017009103225  2017009103229  2017009103230  2017009103289  2017009200472  2017009200491  2017009200502  2017009200509  2017009200515  2017009103185  2017009103188  2017009103143  2017009103147  2017009103155  2017009103191  2017009200518  2017009103116  2017009103124  2017009103129  2017009103133  2017009103135  2017009103107  2017009103109  2017009103117  2017009103122  2017009103125  2017009103130  2017009103132  2017009103134  2017009103136  2017009103142  2017009103145  2017009103146  2017009103148  2017009103150  2017009103144  2017009103149  2017009103453  2017009103487  2017009103471  2017009103472  2017009103510  2017009103511  2017009103512  2017009103517  2017009103518  2017009103520  2017009103521  2017009103522  2017009103523  2017009103524  2017009103526  2017009103528  2017009103529  2017009103530  2017009103502  2017009103486  2017009103493  2017009103494  2017009103497  2017009103503  2017009103506  2017009103508  2017009103513  2017009103519  2017009103525  2017009200520  2017009103045  2017009103051  2017009103055  2017009103056  2017009103059  2017009103099  2017009103499  2017009103014  2017009103024  2017009103053  2017009103057  2017009103060  2017009103061  2017009103081  2017009103083  2017009103084  2017009103095  2017009103096  2017009103105  2017009103110  2017009103118  2017009103119  2017009103121  2017009103123  2017009103126  2017009103127  2017009103128  2017009103131  2017009103152  2017009103168  2017009103177  2017009103184  2017009103187  2017009103190  2017009103192  2017009103199  2017009103204  2017009103205  2017009103206  2017009103220  201600803  201600806  2017009200498  2017009102960  2017009102996  2017009103002  2017009103003  2017009103020  2017009103039  2017009103041  2017009103043  2017009103044  2017009103046  2017009103050  2017009103054  2017009103058  2017009103064  2017009103072  2017009103078  2017009103080  2017009102978  2017009102992  2017009102993  2017009102995  2017009102997  2017009103004  2017009103008  2017009103070  2017009103037  2017009103069  2017009103400  2017009103495  2017009103500  2017009103505  2017009103507  2017009103509  2017009102959  2017009102969  2017009102977  2017009102981  2017009102984  2017009102989  2017009102991  2017009103009  2017009200524  2017009200579  2017009200594  2017009200597  2017009200601  2017009200603  2017009200611  2017009102802  2017009102956  2017009102958  2017009102961  2017009102962  2017009102964  2017009102966  2017009102967  2017009102968  2017009102970  2017009102971  2017009102973  2017009102974  2017009102975  2017009102979  2017009102982  2017009102985  2017009102986  2017009102987  2017009102988  2017009102990  201700910113  2017009103075  2017009103036  2017009103067  2017009103076  2017009103077  2017009103085  2017009103087  2017009103088  2017009103093  2017009103101  2017009103102  2017009103103  2017009103106  2017009103108  2017009103114  2017009103120  2017009200570  2017009200583  2017009200588  2017009200596  2017009200600  2017009200602  2017009200608  2017009200613  TP700K51474  2017009103049  2017009103052  2017009103062  2017009103063  2017009103071  2017009103082  2017009103086  2017009103089  2017009103090  2017009103091  2017009103092  2017009103094  2017009103097  2017009103098  2017009103100  2017009103104  2017009103112  2017009103115  2017009103154  2017009103167  2017009103330  2017009103334  2017009103336  2017009103337  2017009102947  2017009102949  2017009102953  2017009102955  2017009102963  2017009103018  2017009103179  2017009103194  2017009103195  2017009103197  2017009103202  2017009103332  2017009103311  2017009103312  2017009103313  2017009103314  2017009103315  2017009103316  2017009103317  2017009103318  2017009103320  2017009103321  2017009103322  2017009103323  2017009103324  2017009103325  2017009103328  2017009103329  2017009103331  2017009103333  2017009103335  2017009103338  2017009103339  2017009103341  2017009103342  2017009103343  2017009103347  2017009103360  2017009103368  2017009103370  2017009103379  2017009103381  2017009103386  201700910386  2017009103151  2017009103157  2017009103166  201700910318  2017009103319  2017009103327  2017009103357  2017009103366  2017009103344  2017009103345  2017009103346  2017009103348  2017009103350  2017009103351  2017009103352  2017009103354  2017009103355  2017009103356  2017009103358  2017009103361  2017009103362  2017009103363  2017009103364  2017009103365  2017009103367  2017009103369  2017009103372  2017009103373  2017009103376  2017009103377  2017009103378  2017009103380  2017009103385  2017009103475  2017009103488  2017009103492  2017009103440  2017009103465  2017009103468  2017009103470  2017009103474  2017009103478  2017009103481  2017009103489  2017009103490  2017009103491  2017009103498  2017009103504  201700920058  2017009103469  2017009103482  2017009103483  2017009103473  2017009103477  2017009103479  2017009103480  2017009103484  2017009103485  2017009103496  2017009103501  20177009103454  2017009200572  2017009200578  2017009200582  2017009200592  2017009200605  2017009200609  2017009103137  2017009103138  2017009103140  2017009103141  2017009103153  2017009103156  2017009103158  2017009103159  2017009103161  2017009103163  2017009103164  2017009103165  2017009103169  2017009103170  2017009103171  2017009103173  2017009103174  2017009103176  2017009103180  2017009103182  2017009103183  2017009103193  2017009103196  2017009103200  2017009103415  2017009103426  2017009103430  2017009103432  2017009103433  2017009103438  2017009103441  2017009103443  2017009103452  2017009103455  2017009103456  2017009103457  2017009103458  2017009103461  2017009103463  2017009103403  2017009103405  2017009103412  2017009103417  2017009103421  2017009103424  2017009103428  2017009103429  2017009103434  2017009103435  2017009103436  2017009103437  2017009103439  2017009103442  2017009103444  2017009103445  2017009103446  2017009103448  2017009103449  2017009103450  2017009103451  2017009103459  2017009103460  2017009103462  2017009103464  2017009103466  2017009103467  2017009103476  2017009200577  2017009200590  2017009200595  2017009200598  2017009200599  2017009103374  2017009103389  2017009103398  2017009103406  2017009103407  2017009103411  2017009103413  2017009103418  2017009103419  2017009103420  2017009103422  2017009103425  2017009103427  2017009103431  2017009200568  2017009200569  2017009200571  2017009200573  2017009200574  2017009200575  2017009200576  2017009200587  2017009200589  2017009200593  2017009200639  2017009200654  2017009103139  2017009103162  2017009103271  2017009103260  2017009103265  2017009103274  2017009103275  2017009103276  2017009103278  2017009103279  2017009103280  2017009103281  2017009103282  2017009103283  2017009103284  2017009103285  2017009103291  2017009103292  2017009103298  2017009103300  2017009103301  2017009103349  2017009103359  2017009103371  2017009103382  2017009103383  2017009103384  2017009103387  2017009103390  2017009103391  2017009103392  2017009103393  2017009103394  2017009103395  2017009103396  2017009103397  2017009103399  2017009103401  2017009103402  2017009103404  2017009103408  2017009103409  2017009103410  2017009103414  2017009103416  2017009200632  2017009103234  2017009103246  2017009103270  2017009103228  2017009103244  2017009103272  2017009103273  2017009103286  2017009103287  2017009103277  2017009103288  2017009103295  2017009200646  2017009200659  2017009103741  2017009103744  2017009103771  2017009103802  2017009103803  2017009103808  2017009103816  2017009103819  2017009103821  2017009103825  2017009103836  2017009103837  2017009103839  2017009103840  2017009103841  2017009103884  2017009103238  2017009103302  2017009103800  2017009103815  2017009103804  2017009103814  2017009103817  2017009103818  2017009103838  2017009103626  2017009103646  2017009103719  2017009103723  2017009103752  2017009103768  2017009103785  2017009103801  2017009103806  2017009103810  2017009103811  2017009103827  2017009103829  2017009103830  2017009103831  2017009103844  2017009103856  2017009103866  2017009103870  2017009103869  2017009103871  2017009103875  2017009103878  2017009103880  2017009103881  2017009103882  2017009103883  2017009103892  2017009103907  2017009103908  2017009103909  2017009103910  2017009103911  2017009103340  2017009103388  2017009103747  2017009103807  2017009103846  2017009103852  2017009103860  2017009103867  2017009103872  2017009103874  2017009103876  2017009103877  2017009103879  2017009103885  2017009103891  2017009103893  2017009103937  2017009104021  2017009104154  2017009200618  2017009200620  2017009200628  2017009200629  2017009200631  2017009200636  2017009200638  2017009200642  2017009200645  2017009200658  2017009103979  2017009103987  2017009104015  2017009104029  2017009104030  2017009104050  2017009104054  2017009104062  2017009104074  2017009104075  2017009104077  2017009104079  2017009104082  2017009104084  2017009104086  2017009104091  2017009104093  2017009104094  2017009104095  2017009104113  2017009104127  2017009104137  2017009104142  2017009104144  2017009104147  2017009104148  2017009104149  2017009104161  2017009104163  2017009104164  2017009104165  2017009200623  2017009200624  2017009200637  2017009200647  2017009200648  2017009200650  2017009200652  2017009200657  2017009200660  2017009103955  2017009103959  2017009103961  2017009103967  2017009103969  2017009103971  2017009103972  2017009104073  2017009200626  2017009200627  2017009200634  2017009200640  2017009200643  2017009103923  2017009103948  2017009103950  2017009103957  2017009103958  2017009103960  2017009103962  2017009103963  2017009103964  2017009103965  2017009103966  2017009103970  2017009103974  2017009103975  2017009103977  2017009103980  2017009200621  2017009200625  2017009200635  2017009103676  2017009103934  2017009103935  2017009103939  2017009103942  2017009103944  2017009103945  2017009103946  2017009103947  2017009103949  2017009103951  2017009103952  2017009103954  2017009103956  2017009103544  2017009200580  2017009200581  2017009200584  2017009200585  2017009103620  2017009103637  2017009200606  2017009200607  2017009200614  2017009200617  2017009200633  2017009200644  2017009200649  2017009200656  2017009200665  2017009200672  2017009200673  2017009200674  2017009200676  2017009200677  2017009200679  2017009200681  2017009103672  2017009103673  2017009103675  2017009103690  2017009103693  2017009103694  2017009103538  2017009103547  2017009103551  2017009103558  2017009103596  2017009103632  2017009103634  2017009103635  2017009103636  2017009103642  2017009103647  2017009103648  2017009103651  2017009103654  2017009103655  2017009103661  2017009103662  2017009200604  2017009200622  2017009200668  2017009103667  2017009103669  2017009103680  2017009103682  2017009103684  2017009103685  2017009103686  2017009103687  2017009103696  2017009103706  2017009103711  201700910643  2017009103533  2017009103545  2017009103549  2017009103539  2017009103541  2017009103542  2017009103543  2017009103548  2017009103550  2017009103552  2017009103553  2017009103554  2017009103557  2017009103561  2017009103563  2017009103564  2017009103567  2017009103568  2017009103571  2017009103573  2017009103581  2017009103582  2017009200680  2017009103326  2017009103353  2017009103423  201700910536  2017009103532  2017009103534  2017009103535  2017009103537  2017009103578  2017009200670  2017009200671  2017009200675  2017009200678  2017009103540  2017009103565  2017009200662  2017009103920  2017009103932  2017009200641  2017009200651  2017009200653  2017009200655  2017009200661  2017009200666  2017009200667  2017009200669  2017009200755  2017009200759  2017009200763  2017009200770  2017009200771  2017009200783  2017009200797  2017009103894  2017009103918  2017009103933  2017009200777  2017009200787  2017009200790  2017009103921  2017009103895  2017009103896  2017009103897  2017009103899  2017009103901  2017009103904  2017009103905  2017009103906  2017009103912  2017009103913  2017009103914  2017009103917  2017009103922  2017009103924  2017009103928  2017009103929  2017009103930  2017009103931  2017009103938  2017009103941  2017009103940  2017009200726  2017009200765  2017009200792  2017009103898  2017009103900  2017009103902  2017009103903  2017009103915  2017009103916  2017009103919  2017009103936  2017009103943  2017009103953  2017009103968  2017009103978  2017009103981  2017009103982  2017009103984  2017009103988  2017009103990  2017009103991  2017009103992  2017009103994  2017009103995  2017009103999  2017009104000  2017009104001  2017009104003  2017009104004  2017009104006  2017009104007  2017009104008  2017009104011  2017009104012  2017009104013  2017009104014  2017009104016  2017009104018  2017009104019  2017009104022  2017009104023  2017009104024  2017009104025  2017009104027  2017009103993  2017009103976  2017009103983  2017009103986  2017009103989  2017009103998  2017009104002  2017009104036  2017009104038  2017009104040  2017009104046  2017009104051  2017009104059  2017009104060  2017009104061  2017009104063  2017009104067  2017009104068  2017009104009  2017009104017  2017009104026  2017009104031  2017009104032  2017009104034  2017009104039  2017009104043  2017009104064  2017009104065  2017009104069  201700910407  2017009104071  2017009104072  201700910049  2017009103555  2017009103556  2017009103569  2017009103656  2017009103709  2017009103721  2017009103726  2017009103729  2017009103732  2017009200752  2017009200754  2017009200773  2017009200775  2017009200795  2017009200796  2017009103738  201700910374  2017009103740  2017009103743  2017009103746  2017009103749  2017009103754  2017009103755  2017009103758  2017009103761  2017009103762  2017009103766  2017009103767  2017009103770  2017009103772  2017009103778  2017009103779  2017009103780  2017009103783  2017009103784  2017009103787  2017009103788  2017009103789  2017009103790  2017009103791  2017009103797  2017009103798  2017009103985  2017009104005  2017009104033  2017009104041  2017009104045  2017009104047  2017009104055  2017009104057  2017009104066  2017009104076  2017009104109  2017009104114  2017009104125  2017009104133  2017009104143  2017009104145  2017009104153  2017009104158  2017009104048  2017009104070  2017009104080  2017009104085  2017009104099  2017009104107  2017009104110  2017009104115  2017009104116  2017009104117  2017009104118  2017009104122  2017009104129  2017009104155  2017009104157  2017009103640  2017009103644  2017009103653  2017009103657  2017009103659  2017009103666  2017009103670  2017009103674  2017009103677  2017009103678  2017009103679  2017009103681  2017009103683  2017009103688  2017009103689  2017009103691  2017009103692  2017009103695  2017009103697  2017009103698  2017009103700  2017009103703  2017009103704  2017009103705  2017009103708  2017009103710  2017009103712  2017009103713  2017009103717  2017009103718  2017009103720  2017009103722  2017009103724  2017009103725  2017009103727  2017009103728  2017009103730  2017009103733  2017009103735  2017009200741  2017009200769  2017009200772  2017009200779  2017009200780  2017009200782  2017009200785  2017009200788  2017009200789  2017009200794  2017009103736  2017009103742  2017009103757  2017009104035  2017009104042  2017009104044  2017009104081  2017009104100  2017009104101  2017009104106  2017009104112  2017009104130  2017009104132  2017009104152  2017009200778  2017009103745  2017009103776  2017009103560  2017009103562  2017009103566  2017009103570  2017009103574  2017009103589  2017009103639  2017009103664  2017009103609  2017009103610  2017009103611  2017009103612  2017009103613  2017009103614  2017009103615  2017009103616  2017009103618  2017009103619  2017009103621  2017009103622  2017009103624  2017009103625  2017009103627  2017009103629  2017009103630  2017009103633  2017009103638  2017009103641  2017009103645  2017009103649  2017009103650  2017009103652  2017009103658  2017009103660  2017009103663  2017009103665  2017009200718  2017009200728  2017009103716  2017009103668  2017009103671  2017009103715  2017009103731  2017009103734  2017009200746  2017009200762  2017009200774  2017009200776  2017009200781  2017009200784  2017009200786  2017009200791  2017009103750  2017009103765  2017009103737  2017009103739  2017009103748  2017009103751  2017009103753  2017009103759  2017009103760  2017009103763  2017009103764  2017009103769  2017009103773  2017009103774  2017009103781  2017009103782  2017009103792  2017009103793  2017009103794  2017009103795  2017009103796  2017009103799  2017009103805  2017009103812  2017009103842  2017009103845  2017009103853  2017009103855  2017009103858  2017009103859  2017009103861  2017009103862  2017009103863  2017009103864  2017009103865  2017009103868  2017009103873  2017009103531  2017009103631  2017009103775  2017009103809  2017009103813  2017009103820  2017009103822  2017009103826  2017009103832  2017009103833  2017009103834  2017009103835  2017009103843  2017009103847  2017009103848  2017009103849  2017009103850  2017009103851  2017009103854  2017009103857  2017009104140  2017009104150  2017009200725  2017009200729  2017009200733  2017009200735  2017009200736  2017009200739  2017009200743  2017009200747  2017009200751  2017009200756  2017009200760  2017009200766  2017009200750  2017009104028  2017009104037  2017009104078  2017009104083  2017009104087  2017009104088  2017009104092  2017009104096  2017009104097  2017009104102  2017009104103  2017009104104  2017009104105  2017009104111  2017009104119  2017009104120  2017009104121  2017009104124  2017009104126  2017009104131  2017009104134  2017009104139  2017009103546  2017009103572  2017009103576  2017009103579  2017009103580  2017009103583  2017009103584  2017009103585  2017009103586  2017009103588  2017009103590  2017009103593  2017009103595  2017009103597  2017009103598  2017009103599  2017009103600  2017009103601  2017009103559  2017009103575  2017009103577  2017009103587  2017009103591  2017009103592  2017009103594  2017009103602  2017009103603  2017009103605  2017009103606  2017009103607  2017009103608  2017009103617  2017009103623  2017009103604  2017009103628  2017009200748  2017009104053  2017009104056  2017009104058  2017009104089  2017009104090  2017009104098  2017009104123  2017009104128  2017009104136  2017009104138  2017009104141  2017009104151  2017009104360  2017009104424  2017009104428  2017009104465  2017009104520  2017009104421  2017009104429  2017009104466  2017009104536  2017009104539  2017009104542  2017009104552  2017009104555  2017009104557  2017009104553  2017009103527  201709104880  2017009200740  20170009104833  201700104829  201700104830  2017009104382  2017009104388  2017009104533  2017009104410  2017009104411  2017009104412  2017009104455  2017009104478  2017009104491  2017009104494  2017009104508  2017009104517  2017009104521  2017009104522  2017009104529  2017009104530  2017009104535  2017009104537  2017009104538  2017009104550  2017009104559  2017009104620  2017009104622  2017009104637  2017009104728  2017009104808  2017009104814  2017009104815  2017009104817  2017009104831  2017009104834  2017009104838  201700910486  2017009104863  2017009104864  2017009104883  2017009104885  20170094839  20170094885  20170099104868  201709104828  2017009104662  2017009104641  2017009104645  2017009104648  2017009104651  2017009104654  2017009104656  2017009104666  2017009104673  2017009104710  2017009104802  2017009104819  2017009104820  2017009104826  2017009104827  2017009104840  2017009104853  2017009104858  2017009104860  2017009104882  2017009200744  2017009104249  2017009104279  2017009104313  2017009104316  2017009104320  2017009104323  2017009104324  2017009104330  2017009104333  2017009104336  2017009104341  2017009104342  2017009104343  2017009104347  2017009104349  2017009104351  2017009104354  2017009104359  2017009104361  2017009104362  2017009104364  2017009104366  2017009104367  2017009104369  2017009104370  2017009104372  2017009104374  2017009104375  2017009104376  2017009104377  2017009104378  2017009104381  2017009104664  2017009104612  2017009104613  2017009104614  2017009104615  2017009104626  2017009104629  2017009104630  2017009104631  2017009104632  2017009104633  2017009104636  2017009104638  2017009104639  2017009104640  2017009104642  2017009104643  2017009104644  2017009104646  2017009104652  2017009104655  2017009104658  2017009104659  2017009104660  2017009104661  2017009104665  2017009104667  2017009104669  2017009104670  2017009104671  2017009104674  2017009104675  2017009104676  2017009104810  2017009104678  2017009104679  2017009104681  2017009104683  2017009104686  2017009104687  2017009104688  2017009104690  2017009104692  2017009104694  2017009104696  2017009104697  2017009104702  2017009104704  2017009104706  2017009104715  2017009104718  2017009104875  2017009104884  2017009104895  2017009104928  2017009104824  2017009104867  2017009104870  2017009104876  2017009104878  2017009104881  2017009104886  2017009104891  2017009104894  2017009104896  2017009104900  2017009104901  2017009104905  2017009104917  2017009104923  2017009104925  2017009104926  2017009104927  2017009104929  2017009104930  2017009104931  2017009104932  2017009104933  2017009104934  2017009104935  2017009104936  2017009104937  2017009104938  2017009104939  2017009104942  2017009104943  2017009104944  2017009104945  2017009104256  2017009104174  2017009104176  2017009104260  2017009104283  2017009104292  2017009104623  2017009104634  2017009104635  2017009104649  2017009104650  2017009104663  2017009104625  2017009104627  2017009104653  2017009104680  2017009104685  2017009104677  2017009104682  2017009104684  2017009104689  2017009684  2017009104168  2017009104171  2017009104172  2017009104175  2017009104179  2017009104180  2017009104182  2017009104248  2017009104253  2017009104255  2017009104258  2017009104259  2017009104261  2017009104264  2017009104265  2017009104268  2017009104277  2017009104282  2017009104291  2017009104295  2017009104296  2017009104299  2017009104300  2017009104301  2017009104304  2017009104305  2017009103996  2017009104108  2017009104166  2017009104254  2017009104275  2017009104285  2017009104290  2017009104267  2017009104276  2017009104278  2017009104286  2017009104287  2017009104298  2017009104302  2017009104288  2017009104293  2017009104303  2017009104020  2017009104169  2017009104241  2017009104244  2017009104162  2017009104167  2017009104178  2017009104246  2017009104262  2017009104263  2017009104266  2017009104270  2017009104271  2017009104273  2017009104280  2017009104294  2017009104010  2017009104170  2017009104173  2017009104177  2017009104181  2017009104184  2017009104284  2017009104518  2017009104524  2017009104525  2017009104269  2017009104272  2017009104309  2017009104322  2017009104365  2017009104462  2017009104513  2017009104515  2017009104519  2017009104440  2017009104489  2017009104500  2017009104506  2017009104507  2017009104516  2017009104528  2017009200730  2017009200732  2017009200734  2017009200738  2017009200745  2017009200753  2017009200758  2017009200764  2017009104289  2017009104306  2017009104350  2017009104450  2017009104493  2017009104495  2017009104496  2017009104497  2017009104502  2017009104509  2017009104511  2017009104514  2017009104526  2017009104527  2017009104531  2017009104532  2017009104534  2017009104668  2017009104749  2017009104700  2017009104709  2017009104712  2017009104713  2017009104717  2017009104742  2017009104743  2017009104745  2017009104748  2017009104750  2017009104754  2017009104759  2017009104764  2017009104768  2017009104770  2017009104772  2017009104774  2017009104779  2017009104784  2017009104788  2017009104789  2017009104791  2017009104793  2017009104794  2017009104795  2017009104796  2017009200687  2017009200692  2017009200696  2017009200699  2017009200700  2017009200701  2017009200704  2017009200706  2017009200707  2017009200714  2017009200749  2017009104783  2017009104716  2017009104740  2017009104747  2017009104757  2017009104379  2017009104415  2017009104416  2017009104693  2017009104731  2017009104760  2017009104419  2017009200688  2017009200689  2017009200691  2017009200693  2017009200694  2017009200695  2017009200697  2017009200698  2017009200702  2017009200705  2017009200708  2017009200709  2017009200710  2017009200711  2017009200712  2017009200713  2017009200715  2017009200716  2017009200717  2017009200719  2017009200721  2017009200723  2017009104386  2017009104363  2017009104368  2017009104371  2017009104373  2017009104383  2017009104384  2017009104385  2017009104387  2017009104389  2017009104390  2017009104391  2017009104392  2017009104393  2017009104394  2017009104395  2017009104396  2017009104397  2017009104398  2017009104400  2017009104401  2017009104403  2017009104405  2017009104406  2017009104408  2017009104413  2017009104418  2017009104420  2017009104422  2017009104423  2017009104425  2017009104426  2017009200690  2017009200703  2017009200720  2017009200722  2017009200793  2017009200813  2017009200823  2017009200826  2017009200834  2017009200872  2017009104183  2017009104252  2017009104274  2017009104281  2017009104297  2017009104307  2017009104308  2017009104310 2017009104317  2017009104318  2017009104319  2017009104321  2017009104325  2017009104326  2017009104327  2017009104328  2017009104329  2017009104331  2017009104332  2017009104337  2017009104338  2017009104339  2017009104340  2017009104344  2017009104348  2017009104352  2017009104353  2017009104355  2017009104356  2017009104357  2017009104358  2017009104946  TP700C61209  TP700C61239  201600805  201600814  201602186 2016009100349 2017009104146  201600129 201600197 201600200 201600207 201600611 201600692 201600770 201600866 201600893 201601376 201601625 201601683 201601990 201602009 201602010 201602011 201602012 201602353 201602478 201602584 201602604 201602655 201603194 2016009100071 2016009100206 2016009100312 2016009100351 2016009100542 2016009100592 2016009100719 2016009100749 2016009100762 2016009100981 2016009101144 2016009101261 2016009101306 2016009101325 2016009101326 2016009101327 2016009101332 2016009101338 2016009101339 2016009101340 2016009101352 2016009101353 2016009101356 2016009101367 2016009101424 2016009101427 2016009101435 2016009101440 2016009101441 2016009101444 2016009101448 2016009101454 2016009101460 2016009101467 2016009101472 2016009101475 2016009101476 2016009101477 2016009101480 2016009101482 2016009101490 2016009101493 2016009101499 2016009101507 2016009101510 2016009101525 2016009101588 2016009101606 2016009101709 2016009101822 2016009200060 2016009200071 2016009200086 2016009200088 2016009200101 2016009200108 2016009200109 2016009200110 2016009200119 2016009200197 2017009101977 2017009102064 2017009102135 2017009102252 2017009105738 2017009105739 2017009105740 2017009105742 2017009105743 2017009105742 2017009105743 2017009105745 2017009105746 2017009105747 2017009105748 2017009105749 2017009105750 2017009105751 2017009200255 2017009200356 2017009200378 2017009200425 2017009200858 2017009201039  
FEI Number 1831750
Recalling Firm/
Manufacturer
Stryker Medical Division of Stryker Corporation
3800 E Centre Ave
Portage MI 49002-5826
For Additional Information ContactVictoria Haney
269-389-8306
Manufacturer Reason
for Recall
The T/Pump Operations Manual and Maintenance Manual were incorrectly revised to add the sentence, Temperature therapy can also be for heat conservation for normothermia maintenance to the Indications for Use statement.
FDA Determined
Cause 2
Error in labeling
ActionThe following actions are included in the consignee letter: 1. Locate the operations (101515 rev D.0) and maintenance (101176 rev F.0) manuals that accompanied the units listed on the attached business reply form. 2. Find the corrected pages included in this letter and insert one into each affected manual at your location. 3. Complete the enclosed business reply form to acknowledge that you have received and understand this notification. 4. Return your completed business reply form by fax 269 488 8691 or email productfieldaction@stryker.com to Strykers regulatory department. 5. If you have loaned or sold any of the products listed in this letter, please forward a copy of this notice to the new users and advise us of their new location in the space provided on the business reply form. 6. If you have disposed of any of these units and they are no longer in use, please, advise us of their obsolescence by providing us with their serial number in the space provided on the business reply form.
Quantity in Commerce9902
DistributionDistributed in all 50 states, the District of Columbia, and Guam.
Total Product Life CycleTPLC Device Report

1 A record in this database is created when a firm initiates a correction or removal action. The record is updated if the FDA identifies a violation and classifies the action as a recall, and it is updated for a final time when the recall is terminated. Learn more about medical device recalls.
2 Per FDA policy, recall cause determinations are subject to modification up to the point of termination of the recall.
3 For details about termination of a recall see Code of Federal Regulations (CFR) Title 21 �7.55.