|
Class 2 Device Recall MiniMed" 780G Insulin Pump |
|
Date Initiated by Firm |
March 15, 2021 |
Create Date |
June 01, 2021 |
Recall Status1 |
Open3, Classified |
Recall Number |
Z-1771-2021 |
Recall Event ID |
87735 |
PMA Number |
P160017 |
Product Classification |
Automated insulin dosing device system, single hormonal control - Product Code OZP
|
Product |
MiniMed 780G Insulin Pump: Models: PUMP MMT-1885 MM780G 6.5V BLE MMOL;¿ PUMP MMT-1886 MM780G 6.5W BLE MG; KIT MMT-1895WW MM780G 6.5V BLE SF MMOL;¿ KIT MMT-1896WW MM780G 6.5W BLE SF MG;¿ PUMP MMT-1884XC 780G V6.5 CLIN US MG;¿ PUMP MMT-1885XC 780G V6.5 CLIN MM;¿ PUMP MMT-1886XC 780G V6.5 CLIN MG;¿ PUMP MMT-1885L MM780G 6.5V BLE MMOL;¿ PUMP MMT-1886L MM780G 6.5W BLE MG;¿ KIT MMT-1896ES MM780G V6.5W MG;¿ KIT MMT-1896WWA MM780G BLE MG ES;¿ KIT MMT-1895WWA MM780G BLE MMOL AR;¿ KIT MMT-1895WWA MM780G BLE MMOL CS;¿ KIT MMT-1895WWA MM780G BLE MMOL DA;¿ KIT MMT-1895WWA MM780G BLE MMOL DE;¿ KIT MMT-1895WWA MM780G BLE MMOL EN;¿ KIT MMT-1895WWA MM780G BLE MMOL FI;¿ KIT MMT-1895WWA MM780G BLE MMOL FR;¿ KIT MMT-1895WWA MM780G BLE MMOL IT;¿ KIT MMT-1895WWA MM780G BLE MMOL NL;¿ KIT MMT-1895WWA MM780G BLE MMOL NO;¿ KIT MMT-1895WWA MM780G BLE MMOL SL; KIT MMT-1895WWA MM780G BLE MMOL SV;¿ KIT MMT-1895WWA MM780G BLE MMOL HU;¿ KIT MMT-1896WWA MM780G BLE MG AR;¿ KIT MMT-1896WWA MM780G BLE MG DE;¿ KIT MMT-1896WWA MM780G BLE MG EL;¿ KIT MMT-1896WWA MM780G BLE MG HE;¿ KIT MMT-1896WWA MM780G BLE MG IT;¿ KIT MMT-1896WWA MM780G BLE MG PL;¿ KIT MMT-1896WWA MM780G BLE MG RO;¿ KIT MMT-1896WWA MM780G BLE MG TR;¿ KIT MMT-1896WWA MM780G BLE MG NL;¿ KIT MMT-1896WWA MM780G BLE MG FR;¿ KIT MMT-1896WWA MM780G BLE MG ES;
|
Code Information |
Model#(CFN)/UDI-DI(GTIN): MMT-1885/00763000384258;¿ MMT-1886/00763000384265;¿ MMT-1895WW/00763000384272;¿ MMT-1896WW/00763000384289;¿ MMT-1884XC/ 00763000455613;¿ MMT-1885XC/00763000421939;¿ MMT-1886XC/00763000421946;¿ MMT-1885L/00763000441432;¿ MMT-1886L/00763000441449;¿ MMT-1896ES/00763000454296;¿ MMT-1896WWA/00763000411541;¿ KIT MMT-1895WWA/00763000411374;¿ KIT MMT-1895WWA/00763000411381;¿ KIT MMT-1895WWA/00763000411398;¿ KIT MMT-1895WWA/00763000411404;¿ KIT MMT-1895WWA/00763000411411;¿ KIT MMT-1895WWA/00763000411428;¿ KIT MMT-1895WWA/00763000411435;¿ KIT MMT-1895WWA/00763000411459;¿ KIT MMT-1895WWA/00763000411466;¿ KIT MMT-1895WWA/00763000411473;¿ KIT MMT-1895WWA/00763000411497;¿ KIT MMT-1895WWA/00763000411503;¿ KIT MMT-1895WWA/00763000420703;¿ KIT MMT-1895WWA/00763000411510;¿ KIT MMT-1895WWA/00763000411527;¿ KIT MMT-1895WWA/00763000411534;¿ KIT MMT-1895WWA/00763000411565;¿ KIT MMT-1895WWA/00763000411572;¿ KIT MMT-1895WWA/00763000411596;¿ KIT MMT-1895WWA/00763000411619;¿ KIT MMT-1895WWA/00763000411626;¿ MMT-1896WWA/00763000411589;¿ MMT-1896WWA/00763000411558;¿ MMT-1896WWA/00763000411541; Serial Numbers: NG2357677H; NG2377469H; NG2377947H; NG2377975H; NG2378041H; NG2386393H; NG2386401H; NG2386405H; NG2386654H; NG2396576H; NG2397715H; NG2397806H; NG2397932H; NG2408853H; NG2412686H; NG2427129H; NG2428794H; NG2428917H; NG2482370H; NG2482577H; NG2482589H; NG2357431H; NG2357433H; NG2357436H; NG2357444H; NG2357448H; NG2357449H; NG2357452H; NG2357455H; NG2357460H; NG2357463H; NG2357466H; NG2357468H; NG2357473H; NG2357483H; NG2357494H; NG2357495H; NG2357497H; NG2357505H; NG2357507H; NG2357520H; NG2357521H; NG2357526H; NG2357531H; NG2357533H; NG2357538H; NG2357540H; NG2357542H; NG2357545H; NG2357562H; NG2357563H; NG2357564H; NG2357565H; NG2357566H; NG2357568H; NG2357569H; NG2357572H; NG2357584H; NG2357597H; NG2357630H; NG2357633H; NG2357639H; NG2357653H; NG2357667H; NG2357671H; NG2357686H; NG2357690H; NG2357696H; NG2357699H; NG2357703H; NG2357709H; NG2357722H; NG2357723H; NG2357726H; NG2357732H; NG2357733H; NG2357772H; NG2357777H; NG2357780H; NG2357783H; NG2357785H; NG2357788H; NG2357800H; NG2357803H; NG2357813H; NG2357817H; NG2357821H; NG2357822H; NG2357823H; NG2357837H; NG2357838H; NG2357839H; NG2357852H; NG2357854H; NG2357862H; NG2357863H; NG2357876H; NG2357879H; NG2357881H; NG2357884H; NG2358147H; NG2358151H; NG2358153H; NG2358156H; NG2358169H; NG2358194H; NG2358196H; NG2358204H; NG2358205H; NG2358223H; NG2358232H; NG2358256H; NG2358265H; NG2358267H; NG2358274H; NG2358275H; NG2358276H; NG2358279H; NG2358281H; NG2358284H; NG2358289H; NG2358292H; NG2358293H; NG2358297H; NG2358300H; NG2358309H; NG2358311H; NG2358312H; NG2358314H; NG2358319H; NG2358321H; NG2358334H; NG2358335H; NG2358344H; NG2358354H; NG2358356H; NG2358368H; NG2358369H; NG2358370H; NG2358421H; NG2358434H; NG2358450H; NG2358458H; NG2358473H; NG2358481H; NG2358487H; NG2358492H; NG2358501H; NG2358542H; NG2359634H; NG2359652H; NG2359663H; NG2359677H; NG2359691H; NG2359719H; NG2359764H; NG2372093H; NG2372108H; NG2372117H; NG2372475H; NG2372502H; NG2372503H; NG2372508H; NG2372511H; NG2372553H; NG2372557H; NG2372559H; NG2372595H; NG2372625H; NG2372634H; NG2372701H; NG2372703H; NG2372788H; NG2372927H; NG2372949H; NG2372954H; NG2372962H; NG2372964H; NG2372969H; NG2372999H; NG2373241H; NG2373250H; NG2373270H; NG2373271H; NG2373347H; NG2373348H; NG2373369H; NG2373388H; NG2373389H; NG2373466H; NG2374720H; NG2374734H; NG2374786H; NG2374791H; NG2374799H; NG2374819H; NG2374881H; NG2374882H; NG2374945H; NG2374960H; NG2374997H; NG2375065H; NG2375097H; NG2375116H; NG2375147H; NG2375437H; NG2375441H; NG2375444H; NG2375456H; NG2375466H; NG2375521H; NG2375612H; NG2375638H; NG2375648H; NG2375653H; NG2375654H; NG2375656H; NG2375674H; NG2375684H; NG2375765H; NG2375772H; NG2375848H; NG2375867H; NG2375878H; NG2375892H; NG2375900H; NG2375926H; NG2375981H; NG2375984H; NG2376019H; NG2376020H; NG2376026H; NG2376040H; NG2376050H; NG2376051H; NG2376059H; NG2376073H; NG2376106H; NG2376226H; NG2376379H; NG2376381H; NG2376398H; NG2376495H; NG2376507H; NG2376508H; NG2376511H; NG2376517H; NG2376520H; NG2376524H; NG2376574H; NG2376576H; NG2376605H; NG2376610H; NG2376629H; NG2376634H; NG2376642H; NG2376653H; NG2376659H; NG2376666H; NG2376672H; NG2376869H; NG2376874H; NG2376876H; NG2376882H; NG2376883H; NG2376884H; NG2376888H; NG2376891H; NG2376893H; NG2376894H; NG2376895H; NG2376898H; NG2376900H; NG2376905H; NG2376907H; NG2376909H; NG2376911H; NG2376915H; NG2376921H; NG2376923H; NG2376924H; NG2376925H; NG2376926H; NG2376934H; NG2376936H; NG2376941H; NG2376968H; NG2376969H; NG2376970H; NG2376976H; NG2376977H; NG2376979H; NG2376982H; NG2376986H; NG2376988H; NG2376990H; NG2376991H; NG2376992H; NG2376994H; NG2376995H; NG2376996H; NG2376999H; NG2377013H; NG2377018H; NG2377020H; NG2377023H; NG2377024H; NG2377025H; NG2377027H; NG2377031H; NG2377032H; NG2377033H; NG2377034H; NG2377037H; NG2377039H; NG2377041H; NG2377047H; NG2377052H; NG2377053H; NG2377056H; NG2377059H; NG2377060H; NG2377063H; NG2377067H; NG2377068H; NG2377069H; NG2377071H; NG2377072H; NG2377073H; NG2377074H; NG2377075H; NG2377076H; NG2377077H; NG2377082H; NG2377089H; NG2377091H; NG2377092H; NG2377094H; NG2377098H; NG2377100H; NG2377103H; NG2377104H; NG2377121H; NG2377122H; NG2377123H; NG2377126H; NG2377128H; NG2377129H; NG2377130H; NG2377133H; NG2377134H; NG2377137H; NG2377154H; NG2377155H; NG2377156H; NG2377157H; NG2377162H; NG2377168H; NG2377169H; NG2377170H; NG2377171H; NG2377174H; NG2377175H; NG2377182H; NG2377189H; NG2377192H; NG2377195H; NG2377196H; NG2377197H; NG2377200H; NG2377201H; NG2377202H; NG2377203H; NG2377204H; NG2377207H; NG2377208H; NG2377211H; NG2377220H; NG2377224H; NG2377252H; NG2377253H; NG2377257H; NG2377259H; NG2377262H; NG2377266H; NG2377270H; NG2377272H; NG2377274H; NG2377279H; NG2377282H; NG2377283H; NG2377286H; NG2377287H; NG2377288H; NG2377289H; NG2377292H; NG2377293H; NG2377295H; NG2377296H; NG2377297H; NG2377298H; NG2377312H; NG2377313H; NG2377315H; NG2377317H; NG2377318H; NG2377322H; NG2377327H; NG2377333H; NG2377334H; NG2377335H; NG2377339H; NG2377341H; NG2377344H; NG2377347H; NG2377348H; NG2377349H; NG2377363H; NG2377368H; NG2377370H; NG2377372H; NG2377375H; NG2377387H; NG2377390H; NG2377391H; NG2377393H; NG2377396H; NG2377400H; NG2377401H; NG2377404H; NG2377406H; NG2377410H; NG2377421H; NG2377423H; NG2377426H; NG2377427H; NG2377428H; NG2377430H; NG2377432H; NG2377434H; NG2377436H; NG2377443H; NG2377445H; NG2377470H; NG2377476H; NG2377485H; NG2377496H; NG2377497H; NG2377500H; NG2377503H; NG2377505H; NG2377512H; NG2377514H; NG2377516H; NG2377526H; NG2377531H; NG2377534H; NG2377536H; NG2377540H; NG2377545H; NG2377546H; NG2377551H; NG2377552H; NG2377554H; NG2377560H; NG2377561H; NG2377562H; NG2377564H; NG2377565H; NG2377573H; NG2377578H; NG2377579H; NG2377580H; NG2377582H; NG2377585H; NG2377586H; NG2377587H; NG2377588H; NG2377590H; NG2377599H; NG2377603H; NG2377610H; NG2377616H; NG2377619H; NG2377620H; NG2377624H; NG2377626H; NG2377627H; NG2377628H; NG2377629H; NG2377630H; NG2377632H; NG2377633H; NG2377635H; NG2377640H; NG2377643H; NG2377644H; NG2377647H; NG2377648H; NG2377649H; NG2377651H; NG2377652H; NG2377653H; NG2377654H; NG2377664H; NG2377666H; NG2377668H; NG2377669H; NG2377671H; NG2377673H; NG2377676H; NG2377688H; NG2377692H; NG2377717H; NG2377718H; NG2377722H; NG2377723H; NG2377730H; NG2377733H; NG2377736H; NG2377739H; NG2377740H; NG2377741H; NG2377743H; NG2377750H; NG2377760H; NG2377763H; NG2377764H; NG2377765H; NG2377766H; NG2377768H; NG2377770H; NG2377771H; NG2377773H; NG2377775H; NG2377776H; NG2377777H; NG2377779H; NG2377782H; NG2377784H; NG2377785H; NG2377786H; NG2377788H; NG2377789H; NG2377790H; NG2377791H; NG2377792H; NG2377793H; NG2377794H; NG2377795H; NG2377796H; NG2377797H; NG2377801H; NG2377802H; NG2377805H; NG2377806H; NG2377807H; NG2377808H; NG2377810H; NG2377811H; NG2377812H; NG2377814H; NG2377817H; NG2377818H; NG2377824H; NG2377827H; NG2377832H; NG2377834H; NG2377835H; NG2377836H; NG2377837H; NG2377839H; NG2377840H; NG2377842H; NG2377844H; NG2377846H; NG2377847H; NG2377848H; NG2377850H; NG2377851H; NG2377853H; NG2377854H; NG2377855H; NG2377856H; NG2377857H; NG2377859H; NG2377861H; NG2377862H; NG2377864H; NG2377869H; NG2377870H; NG2377871H; NG2377872H; NG2377873H; NG2377874H; NG2377875H; NG2377878H; NG2377880H; NG2377883H; NG2377888H; NG2377889H; NG2377892H; NG2377893H; NG2377894H; NG2377896H; NG2377898H; NG2377899H; NG2377900H; NG2377902H; NG2377903H; NG2377904H; NG2377905H; NG2377908H; NG2377911H; NG2377913H; NG2377914H; NG2377915H; NG2377917H; NG2377918H; NG2377919H; NG2377920H; NG2377922H; NG2377926H; NG2377929H; NG2377930H; NG2377932H; NG2377935H; NG2377937H; NG2377940H; NG2377942H; NG2377948H; NG2377950H; NG2377961H; NG2377968H; NG2377972H; NG2377976H; NG2377978H; NG2377979H; NG2377982H; NG2377983H; NG2377984H; NG2377986H; NG2377988H; NG2377989H; NG2377992H; NG2377994H; NG2377996H; NG2377997H; NG2377999H; NG2378005H; NG2378006H; NG2378014H; NG2378017H; NG2378021H; NG2378023H; NG2378025H; NG2378026H; NG2378030H; NG2378033H; NG2378034H; NG2378035H; NG2378037H; NG2378039H; NG2378040H; NG2378044H; NG2378046H; NG2378048H; NG2378050H; NG2378051H; NG2378052H; NG2378055H; NG2378056H; NG2378059H; NG2378062H; NG2378065H; NG2378067H; NG2378068H; NG2378069H; NG2378078H; NG2378080H; NG2378081H; NG2378082H; NG2378084H; NG2378086H; NG2378087H; NG2378088H; NG2378089H; NG2378091H; NG2378094H; NG2378098H; NG2378099H; NG2378103H; NG2378104H; NG2378106H; NG2378109H; NG2378111H; NG2378112H; NG2378116H; NG2378117H; NG2378119H; NG2378120H; NG2378121H; NG2378128H; NG2378131H; NG2378137H; NG2378139H; NG2378144H; NG2378145H; NG2378146H; NG2378148H; NG2378149H; NG2378150H; NG2378154H; NG2378155H; NG2378157H; NG2378158H; NG2378159H; NG2378162H; NG2378163H; NG2378166H; NG2378168H; NG2378174H; NG2378180H; NG2378181H; NG2378186H; NG2378187H; NG2378188H; NG2378198H; NG2378202H; NG2378203H; NG2378204H; NG2378206H; NG2378207H; NG2378208H; NG2378228H; NG2378230H; NG2378231H; NG2378232H; NG2378235H; NG2378238H; NG2378239H; NG2378243H; NG2378245H; NG2378246H; NG2378247H; NG2378250H; NG2378253H; NG2378254H; NG2378255H; NG2378271H; NG2378276H; NG2378279H; NG2378282H; NG2378283H; NG2378289H; NG2378290H; NG2378291H; NG2378294H; NG2378296H; NG2378303H; NG2378305H; NG2378306H; NG2378310H; NG2378318H; NG2378587H; NG2378588H; NG2378589H; NG2378590H; NG2378591H; NG2378592H; NG2378593H; NG2378594H; NG2378610H; NG2378617H; NG2378620H; NG2378621H; NG2378624H; NG2378631H; NG2378646H; NG2378651H; NG2378652H; NG2378653H; NG2378654H; NG2378656H; NG2378659H; NG2378662H; NG2378663H; NG2378689H; NG2378695H; NG2378696H; NG2378697H; NG2378698H; NG2378714H; NG2378715H; NG2378717H; NG2378718H; NG2378719H; NG2378720H; NG2378735H; NG2378736H; NG2378738H; NG2378740H; NG2378746H; NG2378757H; NG2378764H; NG2378765H; NG2378771H; NG2378773H; NG2378776H; NG2378777H; NG2378779H; NG2378781H; NG2378785H; NG2378786H; NG2378789H; NG2378794H; NG2378796H; NG2378803H; NG2378808H; NG2378811H; NG2378815H; NG2378817H; NG2378818H; NG2378819H; NG2378828H; NG2378832H; NG2378833H; NG2378835H; NG2378836H; NG2378839H; NG2378841H; NG2378845H; NG2378848H; NG2378851H; NG2378852H; NG2379088H; NG2379091H; NG2379092H; NG2379093H; NG2379118H; NG2379121H; NG2379123H; NG2379127H; NG2379131H; NG2386290H; NG2386291H; NG2386294H; NG2386295H; NG2386296H; NG2386299H; NG2386301H; NG2386302H; NG2386304H; NG2386310H; NG2386314H; NG2386315H; NG2386317H; NG2386318H; NG2386319H; NG2386320H; NG2386321H; NG2386326H; NG2386328H; NG2386330H; NG2386333H; NG2386338H; NG2386339H; NG2386340H; NG2386341H; NG2386343H; NG2386345H; NG2386350H; NG2386351H; NG2386352H; NG2386353H; NG2386356H; NG2386357H; NG2386360H; NG2386363H; NG2386369H; NG2386373H; NG2386375H; NG2386376H; NG2386378H; NG2386383H; NG2386386H; NG2386388H; NG2386390H; NG2386391H; NG2386392H; NG2386396H; NG2386400H; NG2386402H; NG2386406H; NG2386408H; NG2386414H; NG2386417H; NG2386418H; NG2386419H; NG2386423H; NG2386424H; NG2386425H; NG2386426H; NG2386427H; NG2386428H; NG2386431H; NG2386433H; NG2386438H; NG2386440H; NG2386442H; NG2386443H; NG2386445H; NG2386447H; NG2386448H; NG2386451H; NG2386452H; NG2386454H; NG2386455H; NG2386460H; NG2386462H; NG2386468H; NG2386470H; NG2386471H; NG2386472H; NG2386475H; NG2386481H; NG2386483H; NG2386484H; NG2386485H; NG2386487H; NG2386488H; NG2386492H; NG2386496H; NG2386498H; NG2386499H; NG2386500H; NG2386503H; NG2386505H; NG2386507H; NG2386508H; NG2386510H; NG2386511H; NG2386513H; NG2386515H; NG2386519H; NG2386520H; NG2386525H; NG2386534H; NG2386535H; NG2386538H; NG2386539H; NG2386541H; NG2386542H; NG2386543H; NG2386545H; NG2386547H; NG2386557H; NG2386558H; NG2386559H; NG2386560H; NG2386565H; NG2386566H; NG2386572H; NG2386575H; NG2386576H; NG2386581H; NG2386582H; NG2386584H; NG2386586H; NG2386590H; NG2386594H; NG2386597H; NG2386598H; NG2386601H; NG2386605H; NG2386609H; NG2386611H; NG2386612H; NG2386613H; NG2386614H; NG2386615H; NG2386619H; NG2386620H; NG2386621H; NG2386622H; NG2386623H; NG2386626H; NG2386627H; NG2386629H; NG2386631H; NG2386632H; NG2386633H; NG2386638H; NG2386639H; NG2386641H; NG2386644H; NG2386646H; NG2386647H; NG2386648H; NG2386650H; NG2386652H; NG2386656H; NG2386658H; NG2386659H; NG2386660H; NG2386663H; NG2396522H; NG2396523H; NG2396524H; NG2396525H; NG2396526H; NG2396530H; NG2396534H; NG2396536H; NG2396538H; NG2396539H; NG2396541H; NG2396544H; NG2396545H; NG2396547H; NG2396548H; NG2396549H; NG2396561H; NG2396562H; NG2396565H; NG2396566H; NG2396568H; NG2396570H; NG2396572H; NG2396578H; NG2396579H; NG2396581H; NG2396582H; NG2396585H; NG2396586H; NG2396589H; NG2396591H; NG2396592H; NG2396593H; NG2396595H; NG2396596H; NG2396600H; NG2396618H; NG2396620H; NG2396625H; NG2396626H; NG2396628H; NG2396629H; NG2396631H; NG2396632H; NG2396636H; NG2396637H; NG2396638H; NG2396639H; NG2396640H; NG2396644H; NG2396654H; NG2396664H; NG2396665H; NG2396666H; NG2396667H; NG2396668H; NG2396673H; NG2396677H; NG2396680H; NG2396690H; NG2396693H; NG2396701H; NG2396703H; NG2396707H; NG2396708H; NG2396711H; NG2396715H; NG2396716H; NG2396717H; NG2396719H; NG2396732H; NG2396734H; NG2396738H; NG2396748H; NG2396753H; NG2396761H; NG2396764H; NG2396765H; NG2396768H; NG2396770H; NG2396772H; NG2396775H; NG2396776H; NG2396777H; NG2396785H; NG2396787H; NG2396790H; NG2396796H; NG2396799H; NG2396801H; NG2396802H; NG2396803H; NG2396804H; NG2396806H; NG2396810H; NG2396812H; NG2396817H; NG2396818H; NG2396836H; NG2396839H; NG2396842H; NG2396846H; NG2396848H; NG2396850H; NG2396851H; NG2396853H; NG2396861H; NG2396862H; NG2396864H; NG2396871H; NG2396873H; NG2396875H; NG2396877H; NG2396880H; NG2396882H; NG2396884H; NG2396887H; NG2396889H; NG2396892H; NG2396897H; NG2396898H; NG2396900H; NG2396902H; NG2396904H; NG2396906H; NG2396914H; NG2396928H; NG2396941H; NG2396944H; NG2396945H; NG2396951H; NG2396953H; NG2396954H; NG2396956H; NG2396962H; NG2396997H; NG2396998H; NG2396999H; NG2397000H; NG2397002H; NG2397003H; NG2397004H; NG2397005H; NG2397006H; NG2397007H; NG2397009H; NG2397010H; NG2397014H; NG2397021H; NG2397026H; NG2397028H; NG2397035H; NG2397036H; NG2397039H; NG2397042H; NG2397043H; NG2397046H; NG2397054H; NG2397055H; NG2397057H; NG2397059H; NG2397064H; NG2397070H; NG2397072H; NG2397074H; NG2397078H; NG2397080H; NG2397081H; NG2397087H; NG2397090H; NG2397091H; NG2397092H; NG2397095H; NG2397098H; NG2397100H; NG2397113H; NG2397114H; NG2397115H; NG2397121H; NG2397123H; NG2397125H; NG2397126H; NG2397127H NG2397131H; NG2397132H; NG2397134H; NG2397139H; NG2397154H; NG2397158H; NG2397164H; NG2397168H; NG2397170H; NG2397174H; NG2397178H; NG2397190H; NG2397196H; NG2397198H; NG2397200H; NG2397202H; NG2397204H; NG2397212H; NG2397214H; NG2397219H; NG2397222H; NG2397224H; NG2397231H; NG2397233H; NG2397235H; NG2397238H; NG2397240H; NG2397243H; NG2397245H; NG2397248H; NG2397255H; NG2397257H; NG2397260H; NG2397264H; NG2397285H; NG2397290H; NG2397295H; NG2397300H; NG2397308H; NG2397316H; NG2397318H; NG2397320H; NG2397322H; NG2397324H; NG2397331H; NG2397333H; NG2397337H; NG2397339H; NG2397342H; NG2397346H; NG2397350H; NG2397355H; NG2397357H; NG2397358H; NG2397359H; NG2397362H; NG2397363H; NG2397364H; NG2397367H; NG2397369H; NG2397381H; NG2397383H; NG2397384H; NG2397385H; NG2397391H; NG2397393H; NG2397395H; NG2397397H; NG2397400H; NG2397408H; NG2397411H; NG2397414H; NG2397417H; NG2397422H; NG2397424H; NG2397436H; NG2397441H; NG2397444H; NG2397446H; NG2397448H; NG2397456H; NG2397457H; NG2397459H; NG2397460H; NG2397480H; NG2397482H; NG2397483H; NG2397485H; NG2397488H; NG2397492H; NG2397505H; NG2397507H; NG2397513H; NG2397514H; NG2397518H; NG2397519H; NG2397520H; NG2397521H; NG2397522H; NG2397528H; NG2397530H; NG2397531H; NG2397532H; NG2397536H; NG2397541H; NG2397543H; NG2397545H; NG2397547H; NG2397550H; NG2397553H; NG2397554H; NG2397555H; NG2397556H; NG2397557H; NG2397558H; NG2397559H; NG2397560H; NG2397561H; NG2397564H; NG2397567H; NG2397568H; NG2397570H; NG2397581H; NG2397582H; NG2397583H; NG2397584H; NG2397585H; NG2397592H; NG2397602H; NG2397605H; NG2397607H; NG2397609H; NG2397615H; NG2397628H; NG2397630H; NG2397631H; NG2397632H; NG2397633H; NG2397638H; NG2397640H; NG2397641H; NG2397642H; NG2397643H; NG2397645H; NG2397647H; NG2397653H; NG2397655H; NG2397660H; NG2397663H; NG2397666H; NG2397667H; NG2397670H; NG2397671H; NG2397674H; NG2397675H; NG2397676H; NG2397677H; NG2397683H; NG2397686H; NG2397687H; NG2397689H; NG2397691H; NG2397692H; NG2397696H; NG2397699H; NG2397700H; NG2397702H; NG2397704H; NG2397706H; NG2397707H; NG2397712H; NG2397713H; NG2397718H; NG2397719H; NG2397722H; NG2397724H; NG2397725H; NG2397727H; NG2397728H; NG2397729H; NG2397732H; NG2397736H; NG2397737H; NG2397738H; NG2397739H; NG2397740H; NG2397741H; NG2397786H; NG2397787H; NG2397790H; NG2397791H; NG2397794H; NG2397795H; NG2397796H; NG2397797H; NG2397799H; NG2397801H; NG2397802H; NG2397807H; NG2397808H; NG2397813H; NG2397815H; NG2397816H; NG2397819H; NG2397820H; NG2397822H; NG2397823H; NG2397824H; NG2397825H; NG2397845H; NG2397847H; NG2397848H; NG2397850H; NG2397863H; NG2397867H; NG2397871H; NG2397872H; NG2397873H; NG2397874H; NG2397875H; NG2397876H; NG2397888H; NG2397889H; NG2397892H; NG2397893H; NG2397894H; NG2397898H; NG2397899H; NG2397902H; NG2397912H; NG2397915H; NG2397919H; NG2397922H; NG2397927H; NG2397928H; NG2397929H; NG2397931H; NG2397937H; NG2397947H; NG2397950H; NG2397951H; NG2397952H; NG2397956H; NG2397957H; NG2397973H; NG2397988H; NG2402137H; NG2402295H; NG2402319H; NG2402326H; NG2402356H; NG2402431H; NG2402465H; NG2402655H; NG2402702H; NG2402719H; NG2402837H; NG2402874H; NG2402879H; NG2402894H; NG2402900H; NG2402962H; NG2403085H; NG2403113H; NG2403150H; NG2403151H; NG2403519H; NG2403559H; NG2403693H; NG2403765H; NG2403831H; NG2403896H; NG2403898H; NG2403913H; NG2403915H; NG2404055H; NG2404068H; NG2404077H; NG2404134H; NG2404215H; NG2404259H; NG2404386H; NG2404394H; NG2404552H; NG2404564H; NG2404578H; NG2404580H; NG2404611H; NG2404669H; NG2404702H; NG2404762H; NG2404780H; NG2404936H; NG2404988H; NG2405129H; NG2405354H; NG2405394H; NG2405399H; NG2405401H; NG2405427H; NG2405429H; NG2405467H; NG2405476H; NG2405574H; NG2405578H; NG2405615H; NG2405633H; NG2405683H; NG2405732H; NG2405865H; NG2405875H; NG2405894H; NG2405903H; NG2405904H; NG2405906H; NG2405940H; NG2405989H; NG2406043H; NG2406053H; NG2406081H; NG2406188H; NG2406230H; NG2406239H; NG2406264H; NG2406288H; NG2406295H; NG2406344H; NG2406349H; NG2406354H; NG2406355H; NG2406376H; NG2406404H; NG2406434H; NG2406436H; NG2406470H; NG2406473H; NG2406493H; NG2406494H; NG2406497H; NG2406499H; NG2406684H; NG2406733H; NG2406745H; NG2406748H; NG2406762H; NG2406779H; NG2406819H; NG2406822H; NG2406844H; NG2406855H; NG2406897H; NG2406902H; NG2406956H; NG2407016H; NG2407053H; NG2407073H; NG2407161H; NG2407175H; NG2407185H; NG2407195H; NG2407305H; NG2407309H; NG2407353H; NG2407403H; NG2407411H; NG2407525H; NG2407604H; NG2407659H; NG2407669H; NG2407702H; NG2407730H; NG2407739H; NG2407745H; NG2407792H; NG2407826H; NG2407828H; NG2407834H; NG2407835H; NG2407840H; NG2407847H; NG2407892H; NG2407911H; NG2407933H; NG2407943H; NG2407965H; NG2407967H; NG2407978H; NG2408097H; NG2408098H; NG2408148H; NG2408235H; NG2408253H; NG2408381H; NG2408419H; NG2408500H; NG2408523H; NG2408550H; NG2408580H; NG2408673H; NG2408682H; NG2408850H; NG2408858H; NG2408871H; NG2408873H; NG2408875H; NG2408878H; NG2408880H; NG2408901H; NG2408903H; NG2408905H; NG2408907H; NG2408918H; NG2408921H; NG2408924H; NG2408929H; NG2408932H; NG2408943H; NG2408948H; NG2408950H; NG2408954H; NG2408956H; NG2408959H; NG2408961H; NG2408962H; NG2408964H; NG2409011H; NG2409013H; NG2409016H; NG2409017H; NG2409019H; NG2409020H; NG2409029H; NG2409033H; NG2409034H; NG2409037H; NG2409041H; NG2409050H; NG2409059H; NG2409063H; NG2409144H; NG2409151H; NG2409154H; NG2409156H; NG2409161H; NG2409166H; NG2409167H; NG2409173H; NG2409185H; NG2409186H; NG2409195H; NG2409197H; NG2409200H; NG2409202H; NG2409205H; NG2409208H; NG2409211H; NG2409213H; NG2409215H; NG2409221H; NG2409224H; NG2409225H; NG2409228H; NG2409231H; NG2409233H; NG2409234H; NG2409235H; NG2409241H; NG2409242H; NG2409311H; NG2409314H; NG2409316H; NG2409318H; NG2409319H; NG2409320H; NG2409321H; NG2409329H; NG2409333H; NG2409341H; NG2409356H; NG2409373H; NG2409375H; NG2409379H; NG2409387H; NG2409391H; NG2409396H; NG2409399H; NG2409401H; NG2409402H; NG2409409H; NG2409411H; NG2409414H; NG2409416H; NG2409418H; NG2409425H; NG2409429H; NG2409436H; NG2409517H; NG2409525H; NG2409536H; NG2409541H; NG2409569H; NG2409571H; NG2409572H; NG2409573H; NG2409579H; NG2409595H; NG2409600H; NG2409602H; NG2409605H; NG2409610H; NG2409618H; NG2409633H; NG2409635H; NG2409637H; NG2409639H; NG2409658H; NG2409665H; NG2409677H; NG2409689H; NG2409694H; NG2409697H; NG2409703H; NG2409711H; NG2409715H; NG2409718H; NG2409774H; NG2409778H; NG2409781H; NG2409784H; NG2409786H; NG2409790H; NG2409794H; NG2409800H; NG2409971H; NG2409974H; NG2409975H; NG2409978H; NG2409979H; NG2410041H; NG2410043H; NG2410045H; NG2410049H; NG2410097H; NG2410098H; NG2410102H; NG2410120H; NG2410130H; NG2410132H; NG2410133H; NG2410134H; NG2410135H; NG2410136H; NG2410244H; NG2410257H; NG2410260H; NG2410262H; NG2410265H; NG2410269H; NG2410275H; NG2410280H; NG2410283H; NG2410284H; NG2410286H; NG2410294H; NG2410296H; NG2410297H; NG2410306H; NG2410324H; NG2410340H; NG2410343H; NG2410345H; NG2410347H; NG2410352H; NG2410354H; NG2410356H; NG2410357H; NG2410359H; NG2410363H; NG2410366H; NG2410373H; NG2410379H; NG2410384H; NG2410386H; NG2410388H; NG2410393H; NG2410458H; NG2410466H; NG2410474H; NG2410481H; NG2410483H; NG2410488H; NG2410494H; NG2410495H; NG2410496H; NG2410497H; NG2410498H; NG2410502H; NG2410503H; NG2410505H; NG2410508H; NG2410514H; NG2410517H; NG2410524H; NG2410525H; NG2410526H; NG2410531H; NG2410533H; NG2410534H; NG2410535H; NG2410580H; NG2410584H; NG2410589H; NG2410594H; NG2410618H; NG2410620H; NG2410621H; NG2410623H; NG2410624H; NG2410625H; NG2410630H; NG2410632H; NG2410634H; NG2410635H; NG2410646H; NG2410651H; NG2410656H; NG2410658H; NG2410659H; NG2410661H; NG2410662H; NG2410668H; NG2410673H; NG2410677H; NG2410678H; NG2410680H; NG2410682H; NG2410689H; NG2410694H; NG2410700H; NG2410703H; NG2410708H; NG2410713H; NG2410722H; NG2410736H; NG2410738H; NG2410740H; NG2410741H; NG2410743H; NG2410747H; NG2410753H; NG2410762H; NG2410765H; NG2410767H; NG2410772H; NG2410775H; NG2410776H; NG2410781H; NG2410783H; NG2410785H; NG2410786H; NG2410787H; NG2410801H; NG2410805H; NG2410808H; NG2410811H; NG2410813H; NG2410819H; NG2410821H; NG2410822H; NG2410827H; NG2410831H; NG2410832H; NG2411098H; NG2411101H; NG2411104H; NG2411106H; NG2411107H; NG2411110H; NG2411115H; NG2411116H; NG2411117H; NG2411120H; NG2411121H; NG2411126H; NG2411128H; NG2411132H; NG2411136H; NG2411144H; NG2411157H; NG2411158H; NG2411159H; NG2411160H; NG2411161H; NG2411162H; NG2411164H; NG2411176H; NG2411177H; NG2411179H; NG2411180H; NG2411181H; NG2411185H; NG2411186H; NG2411196H; NG2411197H; NG2411201H; NG2411205H; NG2411206H; NG2411208H; NG2411209H; NG2411210H; NG2411213H; NG2411214H; NG2411215H; NG2411216H; NG2411217H; NG2411219H; NG2411220H; NG2411224H; NG2411225H; NG2411230H; NG2411239H; NG2411243H; NG2411244H; NG2411246H; NG2411254H; NG2411256H; NG2411258H; NG2411271H; NG2411272H; NG2411274H; NG2411275H; NG2411276H; NG2411277H; NG2411281H; NG2411282H; NG2411284H; NG2411291H; NG2411297H; NG2411302H; NG2411303H; NG2411304H; NG2411305H; NG2411306H; NG2411307H; NG2411308H; NG2411314H; NG2411466H; NG2411475H; NG2411476H; NG2411478H; NG2411479H; NG2411484H; NG2411486H; NG2411492H; NG2411494H; NG2411496H; NG2411501H; NG2411507H; NG2411512H; NG2411519H; NG2411521H; NG2411524H; NG2411525H; NG2411527H; NG2411530H; NG2411533H; NG2411536H; NG2411537H; NG2411543H; NG2411544H; NG2411545H; NG2411548H; NG2411552H; NG2411555H; NG2411564H; NG2411566H; NG2411568H; NG2411570H; NG2411571H; NG2411573H; NG2411579H; NG2411581H; NG2411585H; NG2411631H; NG2411632H; NG2411634H; NG2411635H; NG2411638H; NG2411640H; NG2411642H; NG2411643H; NG2411644H; NG2411648H; NG2411649H; NG2411652H; NG2411659H; NG2411663H; NG2411709H; NG2411714H; NG2411721H; NG2411724H; NG2411736H; NG2411749H; NG2411751H; NG2411758H; NG2411783H; NG2411786H; NG2411794H; NG2411802H; NG2411804H; NG2411847H; NG2411848H; NG2411849H; NG2411850H; NG2411855H; NG2411863H; NG2411944H; NG2411949H; NG2411951H; NG2411954H; NG2411965H; NG2411969H; NG2411972H; NG2411983H; NG2411984H; NG2411985H; NG2411986H; NG2411988H; NG2411991H; NG2411992H; NG2412015H; NG2412018H; NG2412019H; NG2412022H; NG2412025H; NG2412027H; NG2412041H; NG2412044H; NG2412050H; NG2412054H; NG2412057H; NG2412060H; NG2412061H; NG2412062H; NG2412063H; NG2412064H; NG2412065H; NG2412069H; NG2412073H; NG2412087H; NG2412089H; NG2412091H; NG2412092H; NG2412095H; NG2412096H; NG2412097H; NG2412099H; NG2412104H; NG2412113H; NG2412114H; NG2412117H; NG2412118H; NG2412124H; NG2412126H; NG2412128H; NG2412129H; NG2412131H; NG2412133H; NG2412174H; NG2412180H; NG2412184H; NG2412192H; NG2412214H; NG2412216H; NG2412234H; NG2412241H; NG2412245H; NG2412248H; NG2412272H; NG2412275H; NG2412278H; NG2412282H; NG2412288H; NG2412315H; NG2412317H; NG2412319H; NG2412321H; NG2412327H; NG2412331H; NG2412339H; NG2412346H; NG2412347H; NG2412352H; NG2412353H; NG2412357H; NG2412365H; NG2412381H; NG2412382H; NG2412433H; NG2412439H; NG2412443H; NG2412447H; NG2412467H; NG2412476H; NG2412481H; NG2412484H; NG2412486H; NG2412489H; NG2412491H; NG2412505H; NG2412507H; NG2412510H; NG2412514H; NG2412515H; NG2412516H; NG2412517H; NG2412518H; NG2412520H; NG2412521H; NG2412526H; NG2412528H; NG2412530H; NG2412531H; NG2412533H; NG2412534H; NG2412535H; NG2412539H; NG2412541H; NG2412546H; NG2412552H; NG2412553H; NG2412554H; NG2412556H; NG2412557H; NG2412559H; NG2412563H; NG2412566H; NG2412567H; NG2412569H; NG2412570H; NG2412571H; NG2412598H; NG2412657H; NG2412662H; NG2412672H; NG2412674H; NG2412679H; NG2412691H; NG2412702H; NG2412707H; NG2412709H; NG2412713H; NG2412714H; NG2412716H; NG2412723H; NG2412726H; NG2412741H; NG2412744H; NG2412748H; NG2412752H; NG2412753H; NG2412754H; NG2412764H; NG2412772H; NG2412776H; NG2412777H; NG2412780H; NG2412786H; NG2412788H; NG2412790H; NG2412791H; NG2412793H; NG2412796H; NG2412797H; NG2412798H; NG2412799H; NG2412801H; NG2412803H; NG2412807H; NG2412809H; NG2412817H; NG2412819H; NG2412829H; NG2412830H; NG2412839H; NG2412842H; NG2412843H; NG2412845H; NG2412848H; NG2412852H; NG2412854H; NG2412855H; NG2412857H; NG2412858H; NG2412914H; NG2412915H; NG2412965H; NG2412967H; NG2412970H; NG2412974H; NG2412975H; NG2412977H; NG2413032H; NG2413042H; NG2413045H; NG2413048H; NG2413050H; NG2413054H; NG2413058H; NG2413060H; NG2413096H; NG2413097H; NG2413098H; NG2413100H; NG2413101H; NG2413104H; NG2413105H; NG2413108H; NG2413112H; NG2413122H; NG2413126H; NG2413129H; NG2413130H; NG2413131H; NG2413135H; NG2413136H; NG2413137H; NG2413139H; NG2413142H; NG2413144H; NG2413145H; NG2413148H; NG2413157H; NG2413158H; NG2413159H; NG2413161H; NG2413163H; NG2413165H; NG2413168H; NG2413197H; NG2413199H; NG2413200H; NG2413201H; NG2413202H; NG2413203H; NG2413205H; NG2413209H; NG2413213H; NG2413218H; NG2413220H; NG2413221H; NG2413225H; NG2413226H; NG2413231H; NG2413241H; NG2413243H; NG2413246H; NG2413247H; NG2413249H; NG2413250H; NG2413251H; NG2413252H; NG2413253H; NG2413254H; NG2413259H; NG2413374H; NG2413375H; NG2413387H; NG2413388H; NG2413409H; NG2413423H; NG2413513H; NG2413643H; NG2413680H; NG2413872H; NG2413918H; NG2413952H; NG2413988H; NG2413991H; NG2414007H; NG2414047H; NG2414065H; NG2414088H; NG2414152H; NG2414270H; NG2414295H; NG2414308H; NG2414327H; NG2414343H; NG2414407H; NG2414427H; NG2414445H; NG2414473H; NG2414474H; NG2414482H; NG2414486H; NG2414491H; NG2414493H; NG2414496H; NG2414499H; NG2414504H; NG2414508H; NG2414509H; NG2414512H; NG2414515H; NG2414524H; NG2414526H; NG2414531H; NG2414533H; NG2414534H; NG2414539H; NG2414540H; NG2414552H; NG2414553H; NG2414566H; NG2414582H; NG2414589H; NG2414596H; NG2414599H; NG2414610H; NG2414611H; NG2414618H; NG2414622H; NG2414648H; NG2414670H; NG2414679H; NG2414681H; NG2414691H; NG2414692H; NG2414694H; NG2414705H; NG2414710H; NG2414711H; NG2414717H; NG2414724H; NG2414762H; NG2414785H; NG2414930H; NG2414952H; NG2417482H; NG2417650H; NG2417651H; NG2417660H; NG2417673H; NG2417693H; NG2417711H; NG2417714H; NG2417735H; NG2417737H; NG2417753H; NG2417793H; NG2417826H; NG2417833H; NG2417868H; NG2417869H; NG2417878H; NG2417879H; NG2417881H; NG2418002H; NG2418014H; NG2418017H; NG2418027H; NG2418053H; NG2418056H; NG2418060H; NG2418064H; NG2418078H; NG2418081H; NG2418124H; NG2418125H; NG2418146H; NG2418170H; NG2418223H; NG2418238H; NG2418392H; NG2418406H; NG2418418H; NG2418493H; NG2418503H; NG2418519H; NG2418530H; NG2418534H; NG2418692H; NG2418715H; NG2418807H; NG2418859H; NG2418892H; NG2418935H; NG2419086H; NG2419093H; NG2419687H; NG2419737H; NG2419745H; NG2419747H; NG2419848H; NG2419865H; NG2419872H; NG2419874H; NG2419879H; NG2419881H; NG2419897H; NG2419902H; NG2419903H; NG2419925H; NG2419937H; NG2419975H; NG2420013H; NG2420033H; NG2420041H; NG2420065H; NG2420107H; NG2420132H; NG2420137H; NG2420141H; NG2420145H; NG2420147H; NG2420148H; NG2420150H; NG2420154H; NG2420156H; NG2420160H; NG2420166H; NG2420183H; NG2420186H; NG2420188H; NG2420192H; NG2420193H; NG2420202H; NG2420205H; NG2420212H; NG2420217H; NG2420219H; NG2420220H; NG2420223H; NG2420229H; NG2420232H; NG2420233H; NG2420242H; NG2420245H; NG2420246H; NG2420247H; NG2420253H; NG2420258H; NG2420266H; NG2420280H; NG2420322H; NG2420332H; NG2420334H; NG2420351H; NG2420353H; NG2420366H; NG2420370H; NG2420373H; NG2420397H; NG2420414H; NG2420419H; NG2420421H; NG2420431H; NG2420433H; NG2420435H; NG2420438H; NG2420439H; NG2420442H; NG2420444H; NG2420450H; NG2420454H; NG2420456H; NG2420457H; NG2420458H; NG2420463H; NG2420466H; NG2420469H; NG2420473H; NG2420474H; NG2420492H; NG2420497H; NG2420505H; NG2420578H; NG2420623H; NG2420629H; NG2420635H; NG2420636H; NG2420637H; NG2420638H; NG2420645H; NG2420647H; NG2420652H; NG2420653H; NG2420667H; NG2420670H; NG2420671H; NG2420674H; NG2420677H; NG2420679H; NG2420684H; NG2420689H; NG2420693H; NG2420695H; NG2420696H; NG2420702H; NG2420704H; NG2420705H; NG2420713H; NG2420716H; NG2420721H; NG2420723H; NG2420725H; NG2420726H; NG2420729H; NG2420733H; NG2420736H; NG2420737H; NG2420738H; NG2420740H; NG2420741H; NG2420784H; NG2420793H; NG2420807H; NG2420811H; NG2420818H; NG2420820H; NG2420824H; NG2420836H; NG2420844H; NG2420850H; NG2420852H; NG2420856H; NG2420873H; NG2420879H; NG2420883H; NG2420907H; NG2420913H; NG2420941H; NG2420944H; NG2420961H; NG2420962H; NG2420998H; NG2420999H; NG2421000H; NG2421015H; NG2421019H; NG2421023H; NG2421026H; NG2421066H; NG2421073H; NG2421078H; NG2421082H; NG2421106H; NG2421107H; NG2421131H; NG2421139H; NG2421143H; NG2421160H; NG2421162H; NG2421168H; NG2421179H; NG2421199H; NG2421215H; NG2421248H; NG2421249H; NG2421250H; NG2421260H; NG2421269H; NG2421311H; NG2421320H; NG2421323H; NG2421325H; NG2421331H; NG2421342H; NG2421349H; NG2421351H; NG2421359H; NG2421370H; NG2421396H; NG2421441H; NG2421454H; NG2421473H; NG2421489H; NG2421500H; NG2421502H; NG2421520H; NG2421526H; NG2421527H; NG2421541H; NG2421562H; NG2421574H; NG2421606H; NG2421608H; NG2421610H; NG2421620H; NG2421624H; NG2421626H; NG2421627H; NG2421636H; NG2421659H; NG2421663H; NG2421672H; NG2421684H; NG2421691H; NG2421698H; NG2421701H; NG2421708H; NG2421719H; NG2421722H; NG2421731H; NG2421735H; NG2421754H; NG2421757H; NG2421764H; NG2421781H; NG2421790H; NG2421817H; NG2421821H; NG2421840H; NG2421846H; NG2421858H; NG2421864H; NG2421871H; NG2421873H; NG2421883H; NG2421927H; NG2421930H; NG2421934H; NG2421935H; NG2421946H; NG2421962H; NG2422027H; NG2422031H; NG2422042H; NG2422045H; NG2422049H; NG2422099H; NG2422101H; NG2422109H; NG2422111H; NG2422113H; NG2422115H; NG2422127H; NG2422129H; NG2422159H; NG2422162H; NG2422271H; NG2422416H; NG2422418H; NG2422430H; NG2422437H; NG2422442H; NG2422469H; NG2422543H; NG2422554H; NG2422562H; NG2422576H; NG2422593H; NG2422655H; NG2422682H; NG2422693H; NG2422723H; NG2422731H; NG2422746H; NG2422777H; NG2422791H; NG2422834H; NG2422861H; NG2422888H; NG2422956H; NG2422975H; NG2422989H; NG2422994H; NG2423034H; NG2423041H; NG2423050H; NG2423058H; NG2423069H; NG2423077H; NG2423097H; NG2423101H; NG2423109H; NG2423150H; NG2423168H; NG2423180H; NG2423192H; NG2423277H; NG2423299H; NG2423306H; NG2423317H; NG2423350H; NG2423359H; NG2423423H; NG2423430H; NG2423435H; NG2423439H; NG2423442H; NG2423484H; NG2423487H; NG2423513H; NG2423525H; NG2423549H; NG2423551H; NG2423575H; NG2423589H; NG2423594H; NG2423598H; NG2423604H; NG2423609H; NG2423612H; NG2423613H; NG2423632H; NG2423633H; NG2423636H; NG2423639H; NG2423641H; NG2423665H; NG2423671H;; NG2423684H; NG2423696H; NG2423715H; NG2423740H; NG2423746H; NG2423755H; NG2423764H; NG2423768H; NG2423769H; NG2423772H; NG2423774H; NG2423782H; NG2423786H; NG2423790H; NG2423796H; NG2423798H; NG2423800H; NG2423804H; NG2423806H; NG2423810H; NG2423812H; NG2423827H; NG2423832H; NG2423840H; NG2423847H; NG2423854H; NG2423863H; NG2423875H; NG2423881H; NG2423928H; NG2423948H; NG2423956H; NG2423960H; NG2423966H; NG2423969H; NG2423974H; NG2423994H; NG2423995H; NG2423998H; NG2424002H; NG2424003H; NG2424005H; NG2424008H; NG2424015H; NG2424018H; NG2424021H; NG2424043H; NG2424045H; NG2424046H; NG2424047H; NG2424056H; NG2424057H; NG2424065H; NG2424066H; NG2424108H; NG2424113H; NG2424115H; NG2424116H; NG2424120H; NG2424122H; NG2424147H; NG2424150H; NG2424151H; NG2424155H; NG2424164H; NG2424165H; NG2424166H; NG2424172H; NG2424178H; NG2424188H; NG2424191H; NG2424192H; NG2424193H; NG2424194H; NG2424195H; NG2424196H; NG2424197H; NG2424199H; NG2424206H; NG2424213H; NG2424216H; NG2424218H; NG2424221H; NG2424223H; NG2424248H; NG2424249H; NG2424256H; NG2424267H; NG2424281H; NG2424283H; NG2424416H; NG2424454H; NG2424460H; NG2424463H; NG2424465H; NG2424468H; NG2424471H; NG2424474H; NG2424476H; NG2424484H; NG2424490H; NG2424491H; NG2424494H; NG2424496H; NG2424499H; NG2424503H; NG2424504H; NG2424518H; NG2424522H; NG2424524H; NG2424533H; NG2424534H; NG2424538H; NG2424540H; NG2424544H; NG2424551H; NG2424552H; NG2424554H; NG2424555H; NG2424558H; NG2424591H; NG2424593H; NG2424595H; NG2424596H; NG2424601H; NG2424617H; NG2424622H; NG2424623H; NG2424625H; NG2424635H; NG2424636H; NG2424644H; NG2424666H; NG2424667H; NG2424677H; NG2424678H; NG2424685H; NG2424692H; NG2424693H; NG2424709H; NG2424723H; NG2424725H; NG2424727H; NG2424738H; NG2424746H; NG2424753H; NG2424755H; NG2424756H; NG2424758H; NG2424759H; NG2424760H; NG2424764H; NG2424784H; NG2424791H; NG2424795H; NG2424799H; NG2424815H; NG2424824H; NG2424825H; NG2424843H; NG2424894H; NG2424895H; NG2424919H; NG2424928H; NG2424932H; NG2424940H; NG2424942H; NG2424962H; NG2424981H; NG2424985H; NG2425002H; NG2425017H; NG2425026H; NG2425037H; NG2425043H; NG2425053H; NG2425071H; NG2425079H; NG2425080H; NG2425081H; NG2425094H; NG2425105H; NG2425123H; NG2425127H; NG2425129H; NG2425130H; NG2425133H; NG2425138H; NG2425141H; NG2425144H; NG2425146H; NG2425148H; NG2425181H; NG2425186H; NG2425197H; NG2425202H; NG2425204H; NG2425208H; NG2425211H; NG2425213H; NG2425218H; NG2425229H; NG2425234H; NG2425238H; NG2425244H; NG2425245H; NG2425246H; NG2425255H; NG2425258H; NG2425303H; NG2425311H; NG2425323H; NG2425334H; NG2425335H; NG2425341H; NG2425346H; NG2425347H; NG2425348H; NG2425349H; NG2425355H; NG2425359H; NG2425361H; NG2425366H; NG2425369H; NG2425374H; NG2425379H; NG2425382H; NG2425403H; NG2425404H; NG2425405H; NG2425406H; NG2425407H; NG2425409H; NG2425411H; NG2425413H; NG2425418H; NG2425421H; NG2425423H; NG2425425H; NG2425429H; NG2425430H; NG2425431H; NG2425433H; NG2425445H; NG2425447H; NG2425452H; NG2425459H; NG2425469H; NG2425474H; NG2425475H; NG2425476H; NG2425477H; NG2425481H; NG2425484H; NG2425485H; NG2425489H; NG2425490H; NG2425491H; NG2425493H; NG2425494H; NG2425496H; NG2425497H; NG2425501H; NG2425504H; NG2425508H; NG2425512H; NG2425514H; NG2425515H; NG2425517H; NG2425520H; NG2425522H; NG2425525H; NG2425526H; NG2425527H; NG2425533H; NG2425542H; NG2425545H; NG2425550H; NG2425551H; NG2425553H; NG2425556H; NG2425557H; NG2425566H; NG2425567H; NG2425573H; NG2425579H; NG2425589H; NG2425591H; NG2425592H; NG2425604H; NG2425605H; NG2425610H; NG2425612H; NG2425626H; NG2425628H; NG2425633H; NG2425634H; NG2425640H; NG2425642H; NG2425644H; NG2425645H; NG2425648H; NG2425651H; NG2425652H; NG2425655H; NG2425657H; NG2425659H; NG2425661H; NG2425663H; NG2425664H; NG2425669H; NG2425684H; NG2425687H; NG2425692H; NG2425697H; NG2425703H; NG2425705H; NG2425712H; NG2425714H; NG2425716H; NG2425727H; NG2425728H; NG2425731H; NG2425734H; NG2425736H; NG2425746H; NG2425748H; NG2425753H; NG2425763H; NG2425764H; NG2425765H; NG2425767H; NG2425863H; NG2425870H; NG2425872H; NG2425873H; NG2425876H; NG2425877H; NG2425899H; NG2425901H; NG2425902H; NG2425903H; NG2425917H; NG2425921H; NG2425922H; NG2425931H; NG2425932H; NG2425933H; NG2425940H; NG2425942H; NG2425943H; NG2425949H; NG2425953H; NG2425954H; NG2425955H; NG2425956H; NG2425957H; NG2425959H; NG2425961H; NG2425969H; NG2425971H; NG2425973H; NG2425976H; NG2425977H; NG2425979H; NG2425981H; NG2425982H; NG2425984H; NG2425987H; NG2425988H; NG2425991H; NG2425992H; NG2425995H; NG2425998H; NG2425999H; NG2426000H; NG2426001H; NG2426002H; NG2426004H; NG2426286H; NG2426299H; NG2426302H; NG2426312H; NG2426316H; NG2426319H; NG2426321H; NG2426327H; NG2426349H; NG2426359H; NG2426362H; NG2426371H; NG2426386H; NG2426388H; NG2426392H; NG2426395H; NG2426399H; NG2426412H; NG2426415H; NG2426419H; NG2426423H; NG2426428H; NG2426442H; NG2426444H; NG2426465H; NG2426470H; NG2426471H; NG2426479H; NG2426497H; NG2426500H; NG2426508H; NG2426513H; NG2426522H; NG2426529H; NG2426547H; NG2426550H; NG2426564H; NG2426567H; NG2426571H; NG2426588H; NG2426593H; NG2426605H; NG2426610H; NG2426614H; NG2426617H; NG2426671H; NG2426678H; NG2426681H; NG2426689H; NG2426698H; NG2426700H; NG2426762H; NG2426772H; NG2426780H; NG2426786H; NG2426799H; NG2426801H; NG2426813H; NG2426814H; NG2426815H; NG2426816H; NG2426819H; NG2426822H; NG2426825H; NG2426833H; NG2426843H; NG2426858H; NG2426871H; NG2426875H; NG2426876H; NG2426877H; NG2426879H; NG2426931H; NG2426940H; NG2426941H; NG2426947H; NG2426953H; NG2426959H; NG2426961H; NG2426966H; NG2427017H; NG2427019H; NG2427023H; NG2427038H; NG2427039H; NG2427040H; NG2427069H; NG2427082H; NG2427087H; NG2427094H; NG2427096H; NG2427108H; NG2427126H; NG2427131H; NG2427134H; NG2427137H; NG2427139H; NG2427153H; NG2427154H; NG2427159H; NG2427163H; NG2427165H; NG2427190H; NG2427196H; NG2427198H; NG2427203H; NG2427210H; NG2427212H; NG2427213H; NG2427225H; NG2427247H; NG2427257H; NG2427262H; NG2427265H; NG2427267H; NG2427269H; NG2427271H; NG2427277H; NG2427286H; NG2427306H; NG2427309H; NG2427312H; NG2427313H; NG2427317H; NG2427318H; NG2427321H; NG2427322H; NG2427323H; NG2427325H; NG2427328H; NG2427329H; NG2427337H; NG2427338H; NG2427339H; NG2427340H; NG2427342H; NG2427343H; NG2427374H; NG2427380H; NG2427387H; NG2427398H; NG2427428H; NG2427430H; NG2427438H; NG2427441H; NG2427456H; NG2427460H; NG2427465H; NG2427470H; NG2427474H; NG2427480H; NG2427508H; NG2427510H; NG2427514H; NG2427519H; NG2427521H; NG2427523H; NG2427556H; NG2427585H; NG2427589H; NG2427596H; NG2427601H; NG2427606H; NG2427611H; NG2427612H; NG2427616H; NG2427617H; NG2427620H; NG2427621H; NG2427622H; NG2427627H; NG2427630H; NG2427636H; NG2427638H; NG2427646H; NG2427649H; NG2427652H; NG2427659H; NG2427663H; NG2427667H; NG2427670H; NG2427672H; NG2427684H; NG2427686H; NG2427687H; NG2427689H; NG2427691H; NG2427692H; NG2427693H; NG2427694H; NG2427698H; NG2427711H; NG2427737H; NG2427739H; NG2427746H; NG2427747H; NG2427755H; NG2427758H; NG2427777H; NG2427780H; NG2427817H; NG2427823H; NG2427844H; NG2427845H; NG2427846H; NG2427853H; NG2427856H; NG2427857H; NG2427963H; NG2427965H; NG2427967H; NG2427975H; NG2427983H; NG2427987H; NG2427992H; NG2427995H; NG2427996H; NG2428010H; NG2428023H; NG2428028H; NG2428030H; NG2428032H; NG2428036H; NG2428051H; NG2428053H; NG2428054H; NG2428057H; NG2428059H; NG2428062H; NG2428064H; NG2428068H; NG2428070H; NG2428071H; NG2428076H; NG2428077H; NG2428078H; NG2428084H; NG2428086H; NG2428091H; NG2428093H; NG2428094H; NG2428120H; NG2428125H; NG2428126H; NG2428130H; NG2428138H; NG2428140H; NG2428146H; NG2428169H; NG2428175H; NG2428178H; NG2428182H; NG2428183H; NG2428185H; NG2428197H; NG2428199H; NG2428219H; NG2428220H; NG2428221H; NG2428223H; NG2428224H; NG2428227H; NG2428229H; NG2428232H; NG2428250H; NG2428258H; NG2428260H; NG2428263H; NG2428268H; NG2428269H; NG2428270H; NG2428273H; NG2428277H; NG2428280H; NG2428282H; NG2428296H; NG2428298H; NG2428301H; NG2428330H; NG2428331H; NG2428333H; NG2428338H; NG2428341H; NG2428348H; NG2428349H; NG2428354H; NG2428356H; NG2428357H; NG2428358H; NG2428360H; NG2428361H; NG2428362H; NG2428372H; NG2428381H; NG2428382H; NG2428384H; NG2428387H; NG2428390H; NG2428392H; NG2428394H; NG2428405H; NG2428406H; NG2428408H; NG2428411H; NG2428412H; NG2428413H; NG2428418H; NG2428419H; NG2428420H; NG2428421H; NG2428426H; NG2428434H; NG2428436H; NG2428437H; NG2428439H; NG2428441H; NG2428443H; NG2428444H; NG2428446H; NG2428450H; NG2428451H; NG2428454H; NG2428455H; NG2428469H; NG2428480H; NG2428482H; NG2428502H; NG2428504H; NG2428507H; NG2428509H; NG2428514H; NG2428515H; NG2428518H; NG2428519H; NG2428523H; NG2428524H; NG2428526H; NG2428532H; NG2428538H; NG2428539H; NG2428540H; NG2428543H; NG2428546H; NG2428547H; NG2428548H; NG2428553H; NG2428554H; NG2428555H; NG2428580H; NG2428582H; NG2428583H; NG2428586H; NG2428592H; NG2428627H; NG2428633H; NG2428641H; NG2428645H; NG2428646H; NG2428649H; NG2428650H; NG2428652H; NG2428654H; NG2428657H; NG2428675H; NG2428676H; NG2428677H; NG2428680H; NG2428682H; NG2428683H; NG2428693H; NG2428698H; NG2428703H; NG2428704H; NG2428705H; NG2428709H; NG2428711H; NG2428743H; NG2428754H; NG2428755H; NG2428757H; NG2428764H; NG2428765H; NG2428775H; NG2428784H; NG2428802H; NG2428803H; NG2428805H; NG2428806H; NG2428808H; NG2428827H; NG2428828H; NG2428830H; NG2428835H; NG2428849H; NG2428850H; NG2428853H; NG2428858H; NG2428859H; NG2428877H; NG2428878H; NG2428879H; NG2428882H; NG2428885H; NG2428886H; NG2428897H; NG2428919H; NG2428921H; NG2428927H; NG2428928H; NG2428929H; NG2428931H; NG2428932H; NG2428933H; NG2428935H; NG2428938H; NG2428939H; NG2428943H; NG2428945H; NG2428946H; NG2428948H; NG2428949H; NG2428952H; NG2428953H; NG2428954H; NG2428956H; NG2428957H; NG2428958H; NG2428961H; NG2428962H; NG2428964H; NG2428965H; NG2428967H; NG2428968H; NG2428970H; NG2428973H; NG2428979H; NG2428980H; NG2428983H; NG2428984H; NG2428985H; NG2428987H; NG2428990H; NG2428993H; NG2428997H; NG2428998H; NG2428999H; NG2429001H; NG2429004H; NG2429005H; NG2429006H; NG2429007H; NG2429008H; NG2429010H; NG2429012H; NG2429014H; NG2429016H; NG2429020H; NG2429023H; NG2429027H; NG2429029H; NG2429031H; NG2429032H; NG2429034H; NG2429035H; NG2429038H; NG2429039H; NG2429042H; NG2429044H; NG2429045H; NG2429046H; NG2429048H; NG2429051H; NG2429052H; NG2429053H; NG2429057H; NG2429060H; NG2429062H; NG2429063H; NG2429065H; NG2429066H; NG2429073H; NG2429075H; NG2429079H; NG2429081H; NG2429466H; NG2429468H; NG2429472H; NG2429474H; NG2429485H; NG2429489H; NG2429499H; NG2429501H; NG2429509H; NG2429518H; NG2429527H; NG2429529H; NG2429535H; NG2429538H; NG2429558H; NG2429559H; NG2429561H; NG2429574H; NG2429576H; NG2429582H; NG2430980H; NG2430983H; NG2430987H; NG2430988H; NG2430996H; NG2430998H; NG2431005H; NG2431009H; NG2431010H; NG2431011H; NG2431020H; NG2431021H; NG2431023H; NG2431027H; NG2431039H; NG2431040H; NG2431041H; NG2431042H; NG2431044H; NG2431049H; NG2431053H; NG2431058H; NG2431062H; NG2431071H; NG2431072H; NG2431073H; NG2431074H; NG2431076H; NG2431077H; NG2431078H; NG2431079H; NG2431088H; NG2431090H; NG2431091H; NG2431092H; NG2431093H; NG2431094H; NG2431095H; NG2431096H; NG2431097H; NG2431099H; NG2431100H; NG2431101H; NG2431106H; NG2431113H; NG2431114H; NG2431115H; NG2431116H; NG2431117H; NG2431120H; NG2431126H; NG2431136H; NG2431151H; NG2431154H; NG2431155H; NG2431159H; NG2431161H; NG2431170H; NG2431176H; NG2431178H; NG2431180H; NG2431181H; NG2431183H; NG2431184H; NG2431194H; NG2431196H; NG2431201H; NG2431204H; NG2431206H; NG2431211H; NG2431213H; NG2431218H; NG2431222H; NG2431232H; NG2431241H; NG2431242H; NG2431247H; NG2431255H; NG2431256H; NG2431260H; NG2431263H; NG2431265H; NG2431269H; NG2431270H; NG2431272H; NG2431282H; NG2431289H; NG2431290H; NG2431292H; NG2431293H; NG2431308H; NG2431310H; NG2431312H; NG2431316H; NG2431318H; NG2431323H; NG2431324H; NG2431325H; NG2431334H; NG2431342H; NG2431352H; NG2431354H; NG2431356H; NG2431360H; NG2431363H; NG2431365H; NG2431372H; NG2431388H; NG2431395H; NG2431396H; NG2431398H; NG2431400H; NG2431404H; NG2431413H; NG2431417H; NG2431420H; NG2431422H; NG2431435H; NG2431436H; NG2431437H; NG2431439H; NG2431464H; NG2431470H; NG2431473H; NG2431475H; NG2431477H; NG2431478H; NG2431480H; NG2431482H; NG2431485H; NG2431491H; NG2431493H; NG2431495H; NG2431497H; NG2431501H; NG2431523H; NG2431524H; NG2431535H; NG2431539H; NG2431541H; NG2431543H; NG2431547H; NG2431548H; NG2431552H; NG2431554H; NG2431559H; NG2431561H; NG2431563H; NG2431568H; NG2431570H; NG2431572H; NG2431575H; NG2431579H; NG2431582H; NG2431656H; NG2431659H; NG2431665H; NG2431668H; NG2431678H; NG2431681H; NG2431683H; NG2431694H; NG2431695H; NG2431699H; NG2431717H; NG2431720H; NG2431723H; NG2431725H; NG2431733H; NG2431740H; NG2431745H; NG2431749H; NG2431762H; NG2431763H; NG2431767H; NG2431785H; NG2431786H; NG2431787H; NG2431789H; NG2431791H; NG2431793H; NG2431795H; NG2431831H; NG2431834H; NG2431847H; NG2431850H; NG2431864H; NG2431868H; NG2431986H; NG2432088H; NG2432092H; NG2432094H; NG2432099H; NG2432100H; NG2432107H; NG2432157H; NG2432235H; NG2432266H; NG2432271H; NG2432279H; NG2432327H; NG2432329H; NG2432344H; NG2432351H; NG2432359H; NG2432391H; NG2432393H; NG2432427H; NG2432437H; NG2432440H; NG2432441H; NG2432445H; NG2432454H; NG2432457H; NG2432473H; NG2432475H; NG2432482H; NG2432490H; NG2432492H; NG2432497H; NG2432499H; NG2432500H; NG2432501H; NG2432504H; NG2432522H; NG2432524H; NG2432527H; NG2432529H; NG2432535H; NG2432538H; NG2432546H; NG2432557H; NG2432574H; NG2432584H; NG2432602H; NG2432613H; NG2432621H; NG2432630H; NG2432662H; NG2432664H; NG2432672H; NG2432675H; NG2432713H; NG2432756H; NG2432765H; NG2432782H; NG2432832H; NG2432846H; NG2432884H; NG2432904H; NG2432917H; NG2433129H; NG2433132H; NG2433140H; NG2433148H; NG2433174H; NG2433183H; NG2433187H; NG2433196H; NG2433198H; NG2433200H; NG2433207H; NG2433236H; NG2433251H; NG2433253H; NG2433273H; NG2433276H; NG2433311H; NG2433320H; NG2433324H; NG2433325H; NG2433331H; NG2433347H; NG2433353H; NG2433394H; NG2433406H; NG2433417H; NG2433447H; NG2433462H; NG2433465H; NG2433467H; NG2433486H; NG2433600H; NG2433607H; NG2433609H; NG2433615H; NG2433624H; NG2433628H; NG2433679H; NG2433746H; NG2433921H; NG2433935H; NG2433940H; NG2433961H; NG2433976H; NG2433993H; NG2433997H; NG2434007H; NG2434009H; NG2434012H; NG2434021H; NG2434047H; NG2434078H; NG2434087H; NG2434090H; NG2434091H; NG2434093H; NG2434094H; NG2434124H; NG2434150H; NG2434259H; NG2434263H; NG2434265H; NG2434269H; NG2434275H; NG2434281H; NG2434297H; NG2434304H; NG2434306H; NG2434331H; NG2434490H; NG2434501H; NG2434533H; NG2434534H; NG2434554H; NG2434555H; NG2434567H; NG2434569H; NG2434572H; NG2434574H; NG2434578H; NG2434587H; NG2434588H; NG2434678H; NG2434702H; NG2434711H; NG2434725H; NG2434751H; NG2434821H; NG2434824H; NG2434833H; NG2434847H; NG2434877H; NG2434913H; NG2434941H; NG2435011H; NG2435036H; NG2435136H; NG2435166H; NG2435230H; NG2435233H; NG2435236H; NG2435302H; NG2435312H; NG2435396H; NG2435411H; NG2435415H; NG2435420H; NG2435443H; NG2435470H; NG2435567H; NG2435621H; NG2435629H; NG2435631H; NG2435723H; NG2435768H; NG2435780H; NG2435783H; NG2435786H; NG2435867H; NG2435870H; NG2435878H; NG2435912H; NG2435914H; NG2435924H; NG2435968H; NG2435969H; NG2435973H; NG2435974H; NG2436049H; NG2436062H; NG2436072H; NG2436080H; NG2436082H; NG2436086H; NG2436088H; NG2436098H; NG2436100H; NG2436108H; NG2436113H; NG2436180H; NG2436185H; NG2436192H; NG2436200H; NG2436216H; NG2436219H; NG2436222H; NG2436243H; NG2436249H; NG2436250H; NG2436263H; NG2436265H; NG2436267H; NG2436274H; NG2436275H; NG2436276H; NG2436278H; NG2436280H; NG2436283H; NG2436310H; NG2436344H; NG2436345H; NG2436359H; NG2436367H; NG2436403H; NG2436408H; NG2436414H; NG2436415H; NG2436425H; NG2436430H; NG2436433H; NG2436441H; NG2436477H; NG2436479H; NG2436482H; NG2436512H; NG2436530H; NG2436531H; NG2436540H; NG2436541H; NG2436542H; NG2436546H; NG2436547H; NG2436548H; NG2436614H; NG2436633H; NG2436635H; NG2436674H; NG2436680H; NG2436682H; NG2436685H; NG2436699H; NG2436706H; NG2436724H; NG2436730H; NG2436732H; NG2436735H; NG2436749H; NG2436756H; NG2436764H; NG2436810H; NG2436864H; NG2436901H; NG2436919H; NG2436944H; NG2436958H; NG2436972H; NG2436980H; NG2436987H; NG2436995H; NG2437022H; NG2437026H; NG2437027H; NG2437032H; NG2437060H; NG2437082H; NG2437105H; NG2437114H; NG2437117H; NG2437120H; NG2437139H; NG2437171H; NG2437179H; NG2437197H; NG2437206H; NG2437218H; NG2437256H; NG2437273H; NG2437275H; NG2437282H; NG2437287H; NG2437296H; NG2437321H; NG2437356H; NG2437360H; NG2437384H; NG2437395H; NG2437420H; NG2437421H; NG2437422H; NG2437433H; NG2437438H; NG2437449H; NG2437451H; NG2437456H; NG2437459H; NG2437461H; NG2437463H; NG2437469H; NG2437476H; NG2437487H; NG2437493H; NG2437500H; NG2437504H; NG2437517H; NG2437522H; NG2437543H; NG2437546H; NG2437557H; NG2437584H; NG2437596H; NG2437599H; NG2437605H; NG2437625H; NG2437636H; NG2437638H; NG2437641H; NG2437646H; NG2437648H; NG2437652H; NG2437655H; NG2437660H; NG2437661H; NG2437775H; NG2437780H; NG2437885H; NG2437888H; NG2437894H; NG2437914H; NG2437917H; NG2437922H; NG2437925H; NG2437926H; NG2437942H; NG2437944H; NG2437950H; NG2437952H; NG2437954H; NG2437958H; NG2437965H; NG2437985H; NG2437990H; NG2437991H; NG2437999H; NG2438003H; NG2438006H; NG2438010H; NG2438046H; NG2438048H; NG2438061H; NG2438124H; NG2438234H; NG2438314H; NG2438317H; NG2465297H; NG2465301H; NG2465303H; NG2465304H; NG2465305H; NG2465307H; NG2465312H; NG2465314H; NG2465322H; NG2465332H; NG2465342H; NG2465343H; NG2465346H; NG2465349H; NG2465350H; NG2465354H; NG2465363H; NG2465364H; NG2465367H; NG2465369H; NG2465370H; NG2465371H; NG2465372H; NG2465383H; NG2465387H; NG2465409H; NG2465410H; NG2465411H; NG2465414H; NG2465415H; NG2465416H; NG2465421H; NG2465422H; NG2465428H; NG2465429H; NG2465433H; NG2465438H; NG2465457H; NG2465460H; NG2465463H; NG2465468H; NG2465475H; NG2465477H; NG2465480H; NG2465481H; NG2465483H; NG2465484H; NG2465487H; NG2465488H; NG2465492H; NG2465494H; NG2465498H; NG2465501H; NG2465506H; NG2465509H; NG2465513H; NG2465527H; NG2465532H; NG2465536H; NG2465545H; NG2465551H; NG2465553H; NG2465555H; NG2465556H; NG2465557H; NG2465558H; NG2465564H; NG2465567H; NG2465575H; NG2465577H; NG2465580H; NG2465581H; NG2465583H; NG2465584H; NG2465587H; NG2465588H; NG2465589H; NG2465590H; NG2465591H; NG2465592H; NG2465593H; NG2465594H; NG2465595H; NG2465598H; NG2465603H; NG2465613H; NG2465616H; NG2465624H; NG2465625H; NG2465627H; NG2465628H; NG2465629H; NG2465630H; NG2465632H; NG2465633H; NG2465641H; NG2465648H; NG2465652H; NG2465654H; NG2465656H; NG2465658H; NG2465667H; NG2465682H; NG2465686H; NG2465691H; NG2465694H; NG2465697H; NG2465698H; NG2465700H; NG2465701H; NG2465702H; NG2465703H; NG2465705H; NG2465706H; NG2465707H; NG2465708H; NG2465709H; NG2465710H; NG2465714H; NG2465716H; NG2465729H; NG2465734H; NG2465737H; NG2465739H; NG2465740H; NG2465741H; NG2465742H; NG2465744H; NG2465747H; NG2465749H; NG2465750H; NG2465752H; NG2465753H; NG2465755H; NG2465757H; NG2465759H; NG2465761H; NG2465763H; NG2465767H; NG2465768H; NG2465770H; NG2465772H; NG2465773H; NG2465775H; NG2465776H; NG2465779H; NG2465780H; NG2465782H; NG2465783H; NG2465785H; NG2465788H; NG2465789H; NG2465790H; NG2465791H; NG2465792H; NG2465795H; NG2465796H; NG2465797H; NG2465800H; NG2465802H; NG2465803H; NG2465805H; NG2465808H; NG2465809H; NG2465810H; NG2465812H; NG2465814H; NG2465817H; NG2465820H; NG2465826H; NG2465827H; NG2465828H; NG2465829H; NG2465832H; NG2465834H; NG2465835H; NG2465838H; NG2465840H; NG2465841H; NG2465842H; NG2465845H; NG2465854H; NG2465856H; NG2465858H; NG2465860H; NG2465862H; NG2465865H; NG2465866H; NG2465867H; NG2465871H; NG2465875H; NG2465877H; NG2465878H; NG2465879H; NG2465880H; NG2465881H; NG2465882H; NG2465883H; NG2465884H; NG2465885H; NG2465886H; NG2465887H; NG2465888H; NG2465889H; NG2465890H; NG2465891H; NG2465894H; NG2465895H; NG2465896H; NG2465897H; NG2465899H; NG2465902H; NG2465903H; NG2465912H; NG2465915H; NG2465916H; NG2465922H; NG2465924H; NG2465925H; NG2465926H; NG2465929H; NG2465931H; NG2465932H; NG2465933H; NG2465936H; NG2465938H; NG2465939H; NG2465950H; NG2465952H; NG2465953H; NG2465955H; NG2465957H; NG2465960H; NG2465962H; NG2465965H; NG2465966H; NG2465967H; NG2465969H; NG2465974H; NG2465976H; NG2465978H; NG2465979H; NG2465980H; NG2465981H; NG2465991H; NG2465992H; NG2465993H; NG2465995H; NG2465999H; NG2466038H; NG2466039H; NG2466041H; NG2466045H; NG2466046H; NG2466047H; NG2466048H; NG2466050H; NG2466055H; NG2466080H; NG2466081H; NG2466083H; NG2466090H; NG2466091H; NG2466095H; NG2466102H; NG2466108H; NG2466114H; NG2466122H; NG2466126H; NG2466129H; NG2466133H; NG2466138H; NG2466140H; NG2466145H; NG2466181H; NG2466183H; NG2466184H; NG2466187H; NG2466188H; NG2466189H; NG2466190H; NG2466193H; NG2466195H; NG2466197H; NG2466198H; NG2466200H; NG2466202H; NG2466206H; NG2466224H; NG2466227H; NG2466230H; NG2466236H; NG2466240H; NG2466241H; NG2466244H; NG2466246H; NG2466247H; NG2466253H; NG2466270H; NG2466276H; NG2466277H; NG2466278H; NG2466280H; NG2466282H; NG2466284H; NG2466286H; NG2466289H; NG2466305H; NG2466308H; NG2466312H; NG2466315H; NG2466331H; NG2466333H; NG2466334H; NG2466335H; NG2466337H; NG2466338H; NG2466347H; NG2466357H; NG2466370H; NG2466381H; NG2466383H; NG2466392H; NG2466394H; NG2466395H; NG2466401H; NG2466406H; NG2466409H; NG2466426H; NG2466455H; NG2466464H; NG2466466H; NG2466467H; NG2466468H; NG2466470H; NG2466493H; NG2466496H; NG2466499H; NG2466502H; NG2466505H; NG2466508H; NG2466514H; NG2466515H; NG2466522H; NG2466529H; NG2466540H; NG2466542H; NG2466562H; NG2466563H; NG2466568H; NG2466569H; NG2466570H; NG2466572H; NG2466574H; NG2466576H; NG2466582H; NG2466588H; NG2466597H; NG2466624H; NG2466636H; NG2466637H; NG2466642H; NG2466643H; NG2466654H; NG2466663H; NG2466665H; NG2466675H; NG2466676H; NG2466678H; NG2466683H; NG2466691H; NG2466692H; NG2466693H; NG2466694H; NG2466698H; NG2466699H; NG2466704H; NG2466711H; NG2466714H; NG2466722H; NG2466725H; NG2466734H; NG2466754H; NG2466816H; NG2466819H; NG2466821H; NG2466823H; NG2466826H; NG2466829H; NG2466831H; NG2466832H; NG2466833H; NG2466834H; NG2466835H; NG2466836H; NG2466837H; NG2466842H; NG2466853H; NG2466855H; NG2466856H; NG2466874H; NG2466875H; NG2466878H; NG2466881H; NG2466884H; NG2466885H; NG2466887H; NG2466890H; NG2466895H; NG2466897H; NG2466905H; NG2466907H; NG2466909H; NG2466913H; NG2466917H; NG2466920H; NG2466922H; NG2466924H; NG2466929H; NG2466932H; NG2466947H; NG2466962H; NG2466963H; NG2466990H; NG2466991H; NG2466994H; NG2466996H; NG2466998H; NG2467001H; NG2467003H; NG2467017H; NG2467027H; NG2467030H; NG2467031H; NG2467033H; NG2467055H; NG2467057H; NG2467058H; NG2467060H; NG2467063H; NG2467064H; NG2467066H; NG2467067H; NG2467068H; NG2467070H; NG2467071H; NG2467072H; NG2467074H; NG2467077H; NG2467078H; NG2467079H; NG2467083H; NG2467085H; NG2467087H; NG2467090H; NG2467095H; NG2467098H; NG2467099H; NG2467103H; NG2467104H; NG2467106H; NG2467133H; NG2467134H; NG2467137H; NG2467138H; NG2467141H; NG2467143H; NG2467144H; NG2467145H; NG2467150H; NG2467157H; NG2467158H; NG2467161H; NG2467162H; NG2467164H; NG2467167H; NG2467171H; NG2467218H; NG2467227H; NG2474717H; NG2474720H; NG2474723H; NG2474728H; NG2474729H; NG2474733H; NG2474734H; NG2474735H; NG2474736H; NG2474741H; NG2474750H; NG2474761H; NG2474771H; NG2474772H; NG2474781H; NG2474787H; NG2474793H; NG2474796H; NG2474811H; NG2474813H; NG2474821H; NG2474824H; NG2474825H; NG2474834H; NG2474844H; NG2474862H; NG2474863H; NG2474868H; NG2474870H; NG2474871H; NG2474872H; NG2474883H; NG2474884H; NG2474887H; NG2474888H; NG2474891H; NG2474894H; NG2474895H; NG2474897H; NG2474898H; NG2474922H; NG2474927H; NG2474931H; NG2474941H; NG2474947H; NG2474949H; NG2474951H; NG2474952H; NG2474953H; NG2474960H; NG2474965H; NG2474969H; NG2474972H; NG2474974H; NG2474980H; NG2474983H; NG2474989H; NG2474991H; NG2474992H; NG2474994H; NG2474995H; NG2474998H; NG2475001H; NG2475004H; NG2475006H; NG2475008H; NG2475010H; NG2475011H; NG2475012H; NG2475016H; NG2475027H; NG2475036H; NG2475042H; NG2475046H; NG2475056H; NG2475059H; NG2475065H; NG2475089H; NG2475104H; NG2475119H; NG2475122H; NG2475125H; NG2475128H; NG2475130H; NG2475131H; NG2475135H; NG2475142H; NG2475151H; NG2475154H; NG2475155H; NG2475160H; NG2475165H; NG2475174H; NG2475180H; NG2475183H; NG2475185H; NG2475187H; NG2475213H; NG2475219H; NG2475264H; NG2475278H; NG2475280H; NG2475284H; NG2475286H; NG2475288H; NG2475295H; NG2475300H; NG2475302H; NG2475304H; NG2475319H; NG2475323H; NG2475325H; NG2475339H; NG2475353H; NG2475354H; NG2475358H; NG2475360H; NG2475362H; NG2475364H; NG2475366H; NG2475370H; NG2475372H; NG2475373H; NG2475374H; NG2475475H; NG2475483H; NG2475489H; NG2475490H; NG2475502H; NG2475517H; NG2475520H; NG2475523H; NG2475540H; NG2475551H; NG2475560H; NG2475561H; NG2475566H; NG2475567H; NG2475572H; NG2475603H; NG2475612H; NG2475619H; NG2475621H; NG2475625H; NG2475628H; NG2475633H; NG2475635H; NG2475638H; NG2475639H; NG2475642H; NG2475645H; NG2475649H; NG2475651H; NG2475652H; NG2475656H; NG2475715H; NG2475721H; NG2475724H; NG2475727H; NG2475729H; NG2475751H; NG2475760H; NG2475762H; NG2475792H; NG2475794H; NG2475798H; NG2475801H; NG2475803H; NG2475809H; NG2475811H; NG2475816H; NG2475827H; NG2475833H; NG2475835H; NG2475840H; NG2475847H; NG2475856H; NG2475859H; NG2475861H; NG2475865H; NG2475869H; NG2475873H; NG2475885H; NG2475892H; NG2475900H; NG2475902H; NG2475905H; NG2475911H; NG2475919H; NG2475923H; NG2475928H; NG2475930H; NG2475952H; NG2475974H; NG2475982H; NG2476012H; NG2476013H; NG2476016H; NG2476017H; NG2476018H; NG2476019H; NG2476021H; NG2476024H; NG2476027H; NG2476035H; NG2476041H; NG2476046H; NG2476050H; NG2476062H; NG2476096H; NG2476100H; NG2476110H; NG2476116H; NG2476123H; NG2476146H; NG2476170H; NG2476185H; NG2476238H; NG2476242H; NG2476244H; NG2476245H; NG2476250H; NG2476252H; NG2476264H; NG2476306H; NG2476310H; NG2476432H; NG2476547H; NG2476551H; NG2476564H; NG2476597H; NG2476601H; NG2482053H; NG2482061H; NG2482062H; NG2482068H; NG2482076H; NG2482081H; NG2482084H; NG2482085H; NG2482093H; NG2482096H; NG2482098H; NG2482100H; NG2482102H; NG2482103H; NG2482113H; NG2482118H; NG2482119H; NG2482124H; NG2482127H; NG2482130H; NG2482131H; NG2482139H; NG2482145H; NG2482150H; NG2482151H; NG2482152H; NG2482153H; NG2482167H; NG2482170H; NG2482171H; NG2482172H; NG2482175H; NG2482195H; NG2482204H; NG2482205H; NG2482210H; NG2482211H; NG2482212H; NG2482213H; NG2482216H; NG2482219H; NG2482223H; NG2482225H; NG2482229H; NG2482230H; NG2482232H; NG2482233H; NG2482234H; NG2482235H; NG2482236H; NG2482237H; NG2482238H; NG2482241H; NG2482245H; NG2482250H; NG2482251H; NG2482253H; NG2482254H; NG2482255H; NG2482256H; NG2482257H; NG2482259H; NG2482260H; NG2482261H; NG2482265H; NG2482266H; NG2482269H; NG2482270H; NG2482273H; NG2482274H; NG2482278H; NG2482280H; NG2482282H; NG2482288H; NG2482289H; NG2482291H; NG2482293H; NG2482327H; NG2482328H; NG2482336H; NG2482339H; NG2482340H; NG2482341H; NG2482343H; NG2482346H; NG2482348H; NG2482349H; NG2482350H; NG2482351H; NG2482353H; NG2482354H; NG2482355H; NG2482360H; NG2482362H; NG2482363H; NG2482366H; NG2482368H; NG2482369H; NG2482373H; NG2482377H; NG2482378H; NG2482380H; NG2482388H; NG2482390H; NG2482391H; NG2482393H; NG2482395H; NG2482402H; NG2482405H; NG2482407H; NG2482409H; NG2482413H; NG2482414H; NG2482415H; NG2482417H; NG2482427H; NG2482431H; NG2482432H; NG2482434H; NG2482473H; NG2482488H; NG2482495H; NG2482500H; NG2482502H; NG2482509H; NG2482511H; NG2482517H; NG2482519H; NG2482528H; NG2482529H; NG2482532H; NG2482544H; NG2482560H; NG2482579H; NG2482584H; NG2482587H; NG2482588H; NG2482590H; NG2482591H; NG2482597H; NG2482598H; NG2482600H; NG2482602H; NG2482603H; NG2482618H; NG2482624H; NG2482626H; NG2482627H; NG2482630H; NG2482645H; NG2482646H; NG2482896H; NG2482898H; NG2482899H; NG2482900H; NG2482901H; NG2482904H; NG2482907H; NG2482908H; NG2482910H; NG2482917H; NG2482919H; NG2482923H; NG2482924H; NG2482928H; NG2482930H; NG2482940H; NG2482946H; NG2482950H; NG2482961H; NG2482968H; NG2482969H; NG2482970H; NG2482972H; NG2482975H; NG2482976H; NG2482979H; NG2482982H; NG2482983H; NG2482985H; NG2482986H; NG2482987H; NG2482990H; NG2482995H; NG2483007H; NG2483008H; NG2483014H; NG2483020H; NG2483021H; NG2483023H; NG2483025H; NG2483026H; NG2483039H; NG2483040H; NG2483045H; NG2483046H; NG2483047H; NG2483048H; NG2483051H; NG2483052H; NG2483056H; NG2483059H; NG2483064H; NG2483073H; NG2483075H; NG2483078H; NG2483083H; NG2483084H; NG2483089H; NG2483090H; NG2483094H; NG2483097H; NG2483099H; NG2483109H; NG2483110H; NG2483115H; NG2483132H; NG2483137H; NG2483143H; NG2483146H; NG2483150H; NG2483155H; NG2483157H; NG2483161H; NG2483165H; NG2483182H; NG2483183H; NG2483192H; NG2483194H; NG2483196H; NG2483202H; NG2483205H; NG2483210H; NG2483214H; NG2483217H; NG2483223H; NG2483224H; NG2483225H; NG2483226H; NG2483227H; NG2483231H; NG2483234H; NG2483235H; NG2483239H; NG2483240H; NG2483241H; NG2483244H; NG2483247H; NG2483254H; NG2483256H; NG2483257H; NG2483258H; NG2483330H; NG2483472H; NG2483483H; NG2483554H; NG2483591H; NG2483611H; NG2483649H; NG2483699H; NG2483757H; NG2483760H; NG2483763H; NG2483770H; NG2483781H; NG2483823H; NG2483922H; NG2483955H; NG2483964H; NG2483968H; NG2483978H; NG2483986H; NG2483992H; NG2484013H; NG2484033H; NG2484034H; NG2484041H; NG2484058H; NG2484083H; NG2484088H; NG2484311H; NG2484365H; NG2484457H; NG2484459H; NG2484470H; NG2484471H; NG2484475H; NG2484489H; NG2484494H; NG2484495H; NG2484506H; NG2484510H; NG2484548H; NG2484549H; NG2484551H; NG2484582H; NG2484598H; NG2484653H; NG2484660H; NG2484685H; NG2484686H; NG2484689H; NG2484700H; NG2484703H; NG2484704H; NG2484706H; NG2484731H; NG2484737H; NG2484739H; NG2484740H; NG2484745H; NG2484746H; NG2484752H; NG2484755H; NG2484756H; NG2484758H; NG2484759H; NG2484762H; NG2484764H; NG2484768H; NG2484769H; NG2484772H; NG2484773H; NG2484775H; NG2484779H; NG2484783H; NG2484784H; NG2484786H; NG2484787H; NG2484788H; NG2484789H; NG2484792H; NG2484793H; NG2484796H; NG2484798H; NG2484799H; NG2484801H; NG2484804H; NG2484807H; NG2484812H; NG2484814H; NG2484816H; NG2484833H; NG2484837H; NG2484840H; NG2484842H; NG2484843H; NG2484879H; NG2484880H; NG2484881H; NG2484892H; NG2484893H; NG2484898H; NG2484907H; NG2484908H; NG2484909H; NG2484911H; NG2484912H; NG2484913H; NG2484914H; NG2484916H; NG2484917H; NG2484920H; NG2484921H; NG2484923H; NG2484931H; NG2484934H; NG2484941H; NG2484943H; NG2484945H; NG2484950H; NG2484956H; NG2484960H; NG2484963H; NG2484972H; NG2484973H; NG2484974H; NG2484977H; NG2484979H; NG2484980H; NG2484981H; NG2484982H; NG2484983H; NG2484985H; NG2484988H; NG2484989H; NG2484998H; NG2485000H; NG2485002H; NG2485003H; NG2485015H; NG2485018H; NG2485019H; NG2485020H; NG2485021H; NG2485022H; NG2485023H; NG2485033H; NG2485034H; NG2485036H; NG2485037H; NG2485039H; NG2485041H; NG2485043H; NG2485045H; NG2485046H; NG2485051H; NG2485052H; NG2485058H; NG2485060H; NG2485061H; NG2485062H; NG2485063H; NG2485066H; NG2485069H; NG2485072H; NG2485074H; NG2485077H; NG2485079H; NG2485080H; NG2485081H; NG2485083H; NG2485084H; NG2485087H; NG2485089H; NG2485092H; NG2485093H; NG2485096H; NG2485097H; NG2485099H; NG2485103H; NG2485109H; NG2485114H; NG2485116H; NG2485121H; NG2485122H; NG2485123H; NG2485124H; NG2485126H; NG2485130H; NG2485131H; NG2485133H; NG2485147H; NG2485148H; NG2485150H; NG2485151H; NG2485156H; NG2485174H; NG2485183H; NG2485339H; NG2515479H; NG2515488H; NG2515491H; NG2515496H; NG2515498H; NG2515500H; NG2515511H; NG2515520H; NG2515524H; NG2515527H; NG2515529H; NG2515530H; NG2515532H; NG2515533H; NG2515534H; NG2515537H; NG2515540H; NG2515541H; NG2515544H; NG2515545H; NG2515546H; NG2515547H; NG2515550H; NG2515557H; NG2515559H; NG2515560H; NG2515564H; NG2515568H; NG2515572H; NG2515573H; NG2515574H; NG2515575H; NG2515576H; NG2515580H; NG2515581H; NG2515583H; NG2515596H; NG2515598H; NG2515599H; NG2515601H; NG2515602H; NG2515605H; NG2515607H; NG2515608H; NG2515614H; NG2515622H; NG2515623H; NG2515624H; NG2515625H; NG2515627H; NG2515628H; NG2515629H; NG2515632H; NG2515633H; NG2515634H; NG2515636H; NG2515639H; NG2515640H; NG2515641H; NG2515643H; NG2515647H; NG2515653H; NG2515655H; NG2515656H; NG2515657H; NG2515684H; NG2515690H; NG2515691H; NG2515692H; NG2515695H; NG2515696H; NG2515697H; NG2515699H; NG2515702H; NG2515704H; NG2515705H; NG2515708H; NG2515712H; NG2515734H; NG2516959H; NG2516963H; NG2516964H; NG2516967H; NG2516984H; NG2517063H; NG2517091H; NG2517094H; NG2517126H; NG2517146H; NG2517151H; NG2517178H; NG2517183H; NG2517199H; NG2517203H; NG2517207H; NG2517218H; NG2517221H; NG2517242H; NG2517251H; NG2517252H; NG2517256H; NG2517259H; NG2517266H; NG2517271H; NG2517272H; NG2517280H; NG2517282H; NG2517298H; NG2517309H; NG2517334H; NG2517335H; NG2517337H; NG2517346H; NG2517353H; NG2517373H; NG2517376H; NG2517398H; NG2517417H; NG2517421H; NG2517466H; NG2517475H; NG2517477H; NG2517482H; NG2517483H; NG2517484H; NG2517485H; NG2517488H; NG2517489H; NG2517494H; NG2517496H; NG2517499H; NG2517507H; NG2517508H; NG2517510H; NG2517518H; NG2517526H; NG2517614H; NG2517617H; NG2517619H; NG2517622H; NG2517625H; NG2517626H; NG2517637H; NG2517659H; NG2517663H; NG2517691H; NG2517724H; NG2517727H; NG2517736H;
NG2517752H; NG2517783H; NG2517788H; NG2517795H; NG2517798H; NG2517802H; NG2517838H; NG2517863H; NG2517874H; NG2517888H; NG2517906H; NG2517908H; NG2517914H; NG2517927H; NG2517932H; NG2517952H; NG2517971H; NG2517982H; NG2517983H; NG2517984H; NG2517986H; NG2517987H; NG2517988H; NG2517993H; NG2517996H; NG2517997H; NG2518000H; NG2518002H; NG2518004H; NG2518006H; NG2518008H; NG2518027H; NG2518037H; NG2518042H; NG2518047H; NG2518053H; NG2518065H; NG2518068H; NG2518097H; NG2518111H; NG2518122H; NG2518126H; NG2518128H; NG2518129H; NG2518130H; NG2518132H; NG2518133H; NG2518134H; NG2518135H; NG2518138H; NG2518140H; NG2518142H; NG2518143H; NG2518149H; NG2518152H; NG2518153H; NG2518159H; NG2518165H; NG2518175H; NG2518177H; NG2518179H; NG2518182H; NG2518183H; NG2518184H; NG2518186H; NG2518188H; NG2518191H; NG2518193H; NG2518194H; NG2518197H; NG2518201H; NG2518202H; NG2518203H; NG2518204H; NG2518205H; NG2518206H; NG2518208H; NG2518214H; NG2518215H; NG2518219H; NG2518221H; NG2518223H; NG2518224H; NG2518227H; NG2518230H; NG2518231H; NG2518233H; NG2518236H; NG2518238H; NG2518250H; NG2518254H; NG2518255H; NG2518258H; NG2518260H; NG2518261H; NG2518295H; NG2518296H; NG2518301H; NG2518304H; NG2518326H; NG2518354H; NG2518364H; NG2518375H; NG2518408H; NG2518421H; NG2518425H; NG2518450H; NG2518468H; NG2518469H; NG2518475H; NG2518476H; NG2518481H; NG2518484H; NG2518494H; NG2518518H; NG2518524H; NG2518529H; NG2518572H; NG2518582H; NG2518588H; NG2518603H; NG2518604H; NG2518639H; NG2518660H; NG2518662H; NG2518665H; NG2518720H; NG2518740H; NG2518744H; NG2518771H; NG2518836H; NG2518857H; NG2518880H; NG2518957H; NG2518978H; NG2519098H; NG2519106H; NG2358277H; NG2372580H; NG2372603H; NG2372745H; NG2372895H; NG2373002H; NG2373246H; NG2373269H; NG2373331H; NG2373350H; NG2373358H; NG2373372H; NG2373378H; NG2373387H; NG2373439H; NG2373452H; NG2373483H; NG2374730H; NG2374795H; NG2374845H; NG2374858H; NG2374866H; NG2375055H; NG2375163H; NG2375167H; NG2375169H; NG2375475H; NG2375584H; NG2375717H; NG2375722H; NG2375752H; NG2375778H; NG2375828H; NG2375919H; NG2375975H; NG2376075H; NG2376458H; NG2376509H; NG2377683H; NG2378210H; NG2396684H; NG2397993H; NG2402184H; NG2402241H; NG2402243H; NG2402244H; NG2402245H; NG2402247H; NG2402249H; NG2402252H; NG2402254H; NG2402255H; NG2402258H; NG2402259H; NG2402264H; NG2402270H; NG2402275H; NG2402280H; NG2402283H; NG2402286H; NG2402288H; NG2402291H; NG2402293H; NG2402299H; NG2402300H; NG2402302H; NG2402303H; NG2402306H; NG2402313H; NG2402316H; NG2402317H; NG2402320H; NG2402321H; NG2402322H; NG2402323H; NG2402324H; NG2402328H; NG2402331H; NG2402333H; NG2402341H; NG2402347H; NG2402367H; NG2402370H; NG2402373H; NG2402380H; NG2402385H; NG2402386H; NG2402388H; NG2402394H; NG2402397H; NG2402411H; NG2402412H; NG2402413H; NG2402415H; NG2402421H; NG2402423H; NG2402429H; NG2402430H; NG2402432H; NG2402435H; NG2402436H; NG2402437H; NG2402439H; NG2402440H; NG2402442H; NG2402445H; NG2402449H; NG2402451H; NG2402452H; NG2402454H; NG2402458H; NG2402462H; NG2402464H; NG2402467H; NG2402469H; NG2402470H; NG2402471H; NG2402527H; NG2402528H; NG2402530H; NG2402531H; NG2402536H; NG2402546H; NG2402547H; NG2402551H; NG2402553H; NG2402554H; NG2402556H; NG2402558H; NG2402561H; NG2402623H; NG2402629H; NG2402630H; NG2402633H; NG2402635H; NG2402638H; NG2402641H; NG2402648H; NG2402649H; NG2402657H; NG2402658H; NG2402659H; NG2402663H; NG2402667H; NG2402669H; NG2402670H; NG2402673H; NG2402674H; NG2402683H; NG2402721H; NG2402746H; NG2402751H; NG2402774H; NG2402776H; NG2402789H; NG2402812H; NG2402831H; NG2402841H; NG2402844H; NG2402845H; NG2402847H; NG2402872H; NG2402873H; NG2402875H; NG2402881H; NG2402944H; NG2402948H; NG2402960H; NG2402963H; NG2402971H; NG2403028H; NG2403031H; NG2403041H; NG2403080H; NG2403127H; NG2403129H; NG2403131H; NG2403132H; NG2403134H; NG2403137H; NG2403141H; NG2403143H; NG2403159H; NG2403167H; NG2403172H; NG2403423H; NG2403436H; NG2403438H; NG2403439H; NG2403441H; NG2403442H; NG2403445H; NG2403457H; NG2403462H; NG2403469H; NG2403472H; NG2403474H; NG2403475H; NG2403476H; NG2403477H; NG2403478H; NG2403479H; NG2403480H; NG2403481H; NG2403482H; NG2403484H; NG2403491H; NG2403505H; NG2403509H; NG2403514H; NG2403515H; NG2403516H; NG2403517H; NG2403518H; NG2403523H; NG2403524H; NG2403526H; NG2403528H; NG2403529H; NG2403531H; NG2403543H; NG2403544H; NG2403545H; NG2403548H; NG2403552H; NG2403553H; NG2403555H; NG2403557H; NG2403558H; NG2403562H; NG2403572H; NG2403574H; NG2403578H; NG2403579H; NG2403583H; NG2403638H; NG2403640H; NG2403645H; NG2403656H; NG2403658H; NG2403681H; NG2403684H; NG2403692H; NG2403695H; NG2403698H; NG2403702H; NG2403724H; NG2403729H; NG2403733H; NG2403734H; NG2403738H; NG2403751H; NG2403768H; NG2403781H; NG2403787H; NG2403833H; NG2403837H; NG2403838H; NG2403845H; NG2403847H; NG2403849H; NG2403850H; NG2403853H; NG2403854H; NG2403855H; NG2403859H; NG2403860H; NG2403861H; NG2403868H; NG2403872H; NG2403885H; NG2403897H; NG2403899H; NG2403908H; NG2403912H; NG2403941H; NG2404020H; NG2404023H; NG2404024H; NG2404026H; NG2404029H; NG2404040H; NG2404041H; NG2404042H; NG2404048H; NG2404066H; NG2404074H; NG2404084H; NG2404093H; NG2404118H; NG2404120H; NG2404129H; NG2404130H; NG2404133H; NG2404161H; NG2404187H; NG2404239H; NG2404272H; NG2404276H; NG2404277H; NG2404278H; NG2404284H; NG2404288H; NG2404289H; NG2404290H; NG2404292H; NG2404310H; NG2404311H; NG2404312H; NG2404317H; NG2404319H; NG2404321H; NG2404324H; NG2404329H; NG2404332H; NG2404333H; NG2404334H; NG2404336H; NG2404338H; NG2404339H; NG2404340H; NG2404341H; NG2404344H; NG2404346H; NG2404347H; NG2404358H; NG2404359H; NG2404360H; NG2404361H; NG2404362H; NG2404363H; NG2404365H; NG2404366H; NG2404367H; NG2404368H; NG2404370H; NG2404376H; NG2404383H; NG2404384H; NG2404390H; NG2404395H; NG2404396H; NG2404407H; NG2404409H; NG2404410H; NG2404411H; NG2404413H; NG2404414H; NG2404415H; NG2404419H; NG2404420H; NG2404423H; NG2404432H; NG2404436H; NG2404439H; NG2404463H; NG2404507H; NG2404572H; NG2404665H; NG2404693H; NG2404817H; NG2404820H; NG2404832H; NG2404840H; NG2404848H; NG2404864H; NG2404886H; NG2404889H; NG2404891H; NG2404895H; NG2404903H; NG2404908H; NG2404910H; NG2404914H; NG2404937H; NG2404938H; NG2404942H; NG2404951H; NG2404959H; NG2404965H; NG2404969H; NG2404989H; NG2404990H; NG2404991H; NG2404995H; NG2405000H; NG2405001H; NG2405018H; NG2405022H; NG2405109H; NG2405113H; NG2405114H; NG2405119H; NG2405121H; NG2405123H; NG2405125H; NG2405144H; NG2405145H; NG2405149H; NG2405150H; NG2405160H; NG2405169H; NG2405174H; NG2405179H; NG2405183H; NG2405184H; NG2405195H; NG2405198H; NG2405212H; NG2405216H; NG2405219H; NG2405223H; NG2405224H; NG2405233H; NG2405234H; NG2405247H; NG2405248H; NG2405264H; NG2405270H; NG2405272H; NG2405273H; NG2405274H; NG2405276H; NG2405278H; NG2405279H; NG2405280H; NG2405281H; NG2405282H; NG2405285H; NG2405287H; NG2405288H; NG2405297H; NG2405300H; NG2405303H; NG2405304H; NG2405306H; NG2405307H; NG2405323H; NG2405327H; NG2405329H; NG2405335H; NG2405338H; NG2405342H; NG2405344H; NG2405348H; NG2405349H; NG2405350H; NG2405351H; NG2405355H; NG2405360H; NG2405361H; NG2405364H; NG2405367H; NG2405370H; NG2405393H; NG2405397H; NG2405402H; NG2405404H; NG2405405H; NG2405406H; NG2405409H; NG2405410H; NG2405413H; NG2405415H; NG2405425H; NG2405431H; NG2405434H; NG2405437H; NG2405440H; NG2405441H; NG2405443H; NG2405444H; NG2405449H; NG2405452H; NG2405454H; NG2405457H; NG2405458H; NG2405459H; NG2405460H; NG2405463H; NG2405464H; NG2405470H; NG2405474H; NG2405492H; NG2405493H; NG2405494H; NG2405496H; NG2405497H; NG2405498H; NG2405501H; NG2405505H; NG2405507H; NG2405511H; NG2405514H; NG2405515H; NG2405537H; NG2405539H; NG2405540H; NG2405541H; NG2405544H; NG2405546H; NG2405554H; NG2405556H; NG2405558H; NG2405560H; NG2405561H; NG2405562H; NG2405564H; NG2405565H; NG2405567H; NG2405569H; NG2405571H; NG2405572H; NG2405587H; NG2405604H; NG2405608H; NG2405620H; NG2405626H; NG2405632H; NG2405641H; NG2405655H; NG2405657H; NG2405661H; NG2405664H; NG2405666H; NG2405670H; NG2405677H; NG2405678H; NG2405681H; NG2405682H; NG2405685H; NG2405686H; NG2405692H; NG2405696H; NG2405697H; NG2405699H; NG2405701H; NG2405704H; NG2405708H; NG2405713H; NG2405718H; NG2405721H; NG2405728H; NG2405785H; NG2405787H; NG2405790H; NG2405792H; NG2405861H; NG2406235H; NG2406257H; NG2406259H; NG2406287H; NG2406291H; NG2406293H; NG2406330H; NG2406332H; NG2406333H; NG2406337H; NG2406342H; NG2406348H; NG2406350H; NG2406356H; NG2406357H; NG2406367H; NG2406371H; NG2406380H; NG2406383H; NG2406388H; NG2406389H; NG2406392H; NG2406406H; NG2406413H; NG2406414H; NG2406417H; NG2406418H; NG2406419H; NG2406420H; NG2406424H; NG2406425H; NG2406426H; NG2406438H; NG2406442H; NG2406451H; NG2406474H; NG2406478H; NG2406491H; NG2406492H; NG2406495H; NG2406496H; NG2406502H; NG2406548H; NG2406559H; NG2406719H; NG2406734H; NG2406751H; NG2406775H; NG2406817H; NG2406850H; NG2406853H; NG2406857H; NG2406896H; NG2406898H; NG2406908H; NG2406912H; NG2406927H; NG2406932H; NG2406951H; NG2406984H; NG2407074H; NG2407083H; NG2407194H; NG2407468H; NG2407475H; NG2407486H; NG2407530H; NG2407539H; NG2407582H; NG2407589H; NG2407598H; NG2407602H; NG2407623H; NG2407655H; NG2407661H; NG2407747H; NG2407749H; NG2407751H; NG2407752H; NG2407759H; NG2407796H; NG2407799H; NG2407800H; NG2407802H; NG2407823H; NG2407825H; NG2407830H; NG2407842H; NG2407846H; NG2407862H; NG2407865H; NG2407867H; NG2407872H; NG2407878H; NG2407880H; NG2407887H; NG2407888H; NG2407890H; NG2407906H; NG2407909H; NG2407910H; NG2407935H; NG2407940H; NG2407945H; NG2407959H; NG2407961H; NG2407963H; NG2407981H; NG2407995H; NG2408000H; NG2408090H; NG2408094H; NG2408099H; NG2408100H; NG2408101H; NG2408114H; NG2408118H; NG2408121H; NG2408122H; NG2408123H; NG2408130H; NG2408133H; NG2408136H; NG2408205H; NG2408209H; NG2408216H; NG2408224H; NG2408226H; NG2408229H; NG2408232H; NG2408249H; NG2408254H; NG2408255H; NG2408256H; NG2408259H; NG2408264H; NG2408271H; NG2408279H; NG2408285H; NG2408294H; NG2408300H; NG2408313H; NG2408326H; NG2408328H; NG2408330H; NG2408335H; NG2408345H; NG2408359H; NG2408368H; NG2408372H; NG2408376H; NG2408378H; NG2408395H; NG2408398H; NG2408400H; NG2408411H; NG2408422H; NG2408462H; NG2408465H; NG2408468H; NG2408472H; NG2408488H; NG2408491H; NG2408495H; NG2408496H; NG2408497H; NG2408508H; NG2408510H; NG2408512H; NG2408532H; NG2408539H; NG2408542H; NG2408544H; NG2408559H; NG2408560H; NG2408561H; NG2408568H; NG2408572H; NG2408578H; NG2408595H; NG2408598H; NG2408609H; NG2408612H; NG2408616H; NG2408660H; NG2408685H; NG2408704H; NG2408707H; NG2408711H; NG2408721H; NG2408739H; NG2408747H; NG2408754H; NG2409607H; NG2410756H; NG2413333H; NG2413334H; NG2413339H; NG2413341H; NG2413344H; NG2413346H; NG2413347H; NG2413348H; NG2413349H; NG2413350H; NG2413352H; NG2413353H; NG2413355H; NG2413365H; NG2413367H; NG2413370H; NG2413371H; NG2413373H; NG2413390H; NG2413393H; NG2413394H; NG2413395H; NG2413396H; NG2413397H; NG2413398H; NG2413399H; NG2413400H; NG2413401H; NG2413405H; NG2413408H; NG2413416H; NG2413464H; NG2413465H; NG2413466H; NG2413467H; NG2413477H; NG2413479H; NG2413481H; NG2413485H; NG2413490H; NG2413492H; NG2413497H; NG2413499H; NG2413500H; NG2413501H; NG2413502H; NG2413503H; NG2413504H; NG2413505H; NG2413506H; NG2413510H; NG2413512H; NG2413517H; NG2413519H; NG2413521H; NG2413530H; NG2413531H; NG2413533H; NG2413534H; NG2413535H; NG2413543H; NG2413549H; NG2413550H; NG2413552H; NG2413554H; NG2413555H; NG2413557H; NG2413565H; NG2413566H; NG2413570H; NG2413572H; NG2413574H; NG2413575H; NG2413577H; NG2413579H; NG2413582H; NG2413606H; NG2413609H; NG2413610H; NG2413613H; NG2413614H; NG2413615H; NG2413616H; NG2413618H; NG2413619H; NG2413620H; NG2413621H; NG2413623H; NG2413624H; NG2413626H; NG2413628H; NG2413630H; NG2413631H; NG2413632H; NG2413633H; NG2413638H; NG2413641H; NG2413642H; NG2413644H; NG2413645H; NG2413647H; NG2413648H; NG2413649H; NG2413650H; NG2413652H; NG2413653H; NG2413654H; NG2413655H; NG2413656H; NG2413658H; NG2413659H; NG2413664H; NG2413665H; NG2413666H; NG2413669H; NG2413671H; NG2413673H; NG2413818H; NG2413820H; NG2413823H; NG2413825H; NG2413827H; NG2413828H; NG2413833H; NG2413835H; NG2413839H; NG2413841H; NG2413844H; NG2413846H; NG2413847H; NG2413848H; NG2413849H; NG2413859H; NG2413860H; NG2413861H; NG2413864H; NG2413866H; NG2413870H; NG2413878H; NG2413880H; NG2413921H; NG2413927H; NG2413932H; NG2413935H; NG2413938H; NG2413947H; NG2413949H; NG2413955H; NG2413957H; NG2413985H; NG2413987H; NG2413989H; NG2413992H; NG2413994H; NG2413995H; NG2413998H; NG2413999H; NG2414010H; NG2414012H; NG2414014H; NG2414015H; NG2414017H; NG2414020H; NG2414040H; NG2414054H; NG2414057H; NG2414058H; NG2414059H; NG2414063H; NG2414077H; NG2414084H; NG2414085H; NG2414086H; NG2414091H; NG2414122H; NG2414127H; NG2414131H; NG2414139H; NG2414141H; NG2414144H; NG2414145H; NG2414159H; NG2414177H; NG2414179H; NG2414180H; NG2414182H; NG2414209H; NG2414210H; NG2414211H; NG2414221H; NG2414242H; NG2414247H; NG2414248H; NG2414250H; NG2414251H; NG2414253H; NG2414255H; NG2414265H; NG2414271H; NG2414274H; NG2414277H; NG2414289H; NG2414291H; NG2414292H; NG2414296H; NG2414300H; NG2414302H; NG2414304H; NG2414309H; NG2414321H; NG2414329H; NG2414331H; NG2414334H; NG2414338H; NG2414345H; NG2414346H; NG2414347H; NG2414361H; NG2414365H; NG2414405H; NG2414408H; NG2414409H; NG2414410H; NG2414411H; NG2414414H; NG2414424H; NG2414439H; NG2414449H; NG2414450H; NG2414452H; NG2414454H; NG2414456H; NG2414471H; NG2414472H; NG2414479H; NG2414481H; NG2414483H; NG2414485H; NG2414489H; NG2414490H; NG2414495H; NG2414497H; NG2414501H; NG2414506H; NG2414507H; NG2414513H; NG2414517H; NG2414518H; NG2414522H; NG2414529H; NG2414532H; NG2414535H; NG2414536H; NG2414537H; NG2414547H; NG2414550H; NG2414555H; NG2414557H; NG2414561H; NG2414574H; NG2414575H; NG2414577H; NG2414581H; NG2414584H; NG2414586H; NG2414590H; NG2414591H; NG2414592H; NG2414593H; NG2414597H; NG2414598H; NG2414600H; NG2414612H; NG2414614H; NG2414615H; NG2414617H; NG2414621H; NG2414623H; NG2414626H; NG2414630H; NG2414632H; NG2414634H; NG2414637H; NG2414640H; NG2414641H; NG2414645H; NG2414646H; NG2414647H; NG2414649H; NG2414650H; NG2414663H; NG2414665H; NG2414666H; NG2414668H; NG2414672H; NG2414674H; NG2414675H; NG2414676H; NG2414677H; NG2414678H; NG2414682H; NG2414683H; NG2414684H; NG2414687H; NG2414689H; NG2414695H; NG2414697H; NG2414698H; NG2414712H; NG2414713H; NG2414716H; NG2414718H; NG2414719H; NG2414721H; NG2414722H; NG2414723H; NG2414727H; NG2414730H; NG2414733H; NG2414737H; NG2414738H; NG2414740H; NG2414741H; NG2414742H; NG2414745H; NG2414752H; NG2414760H; NG2414764H; NG2414786H; NG2414788H; NG2414789H; NG2414791H; NG2414793H; NG2414796H; NG2414798H; NG2414800H; NG2414831H; NG2414836H; NG2414840H; NG2414842H; NG2414849H; NG2414851H; NG2414852H; NG2414854H; NG2414892H; NG2414894H; NG2414904H; NG2414907H; NG2414910H; NG2414913H; NG2414915H; NG2414917H; NG2414922H; NG2414923H; NG2414924H; NG2414932H; NG2414934H; NG2414935H; NG2414936H; NG2414944H; NG2414946H; NG2414950H; NG2414953H; NG2414954H; NG2414955H; NG2414956H; NG2414957H; NG2414958H; NG2414966H; NG2414968H; NG2414969H; NG2414971H; NG2414976H; NG2414979H; NG2414983H; NG2414984H; NG2414985H; NG2414986H; NG2414988H; NG2414991H; NG2414992H; NG2414996H; NG2415000H; NG2415002H; NG2415003H; NG2415004H; NG2415005H; NG2415006H; NG2415008H; NG2415011H; NG2415012H; NG2415013H; NG2415015H; NG2415016H; NG2415017H; NG2415018H; NG2415019H; NG2415021H; NG2415030H; NG2415031H; NG2415032H; NG2415033H; NG2415035H; NG2415036H; NG2415037H; NG2415054H; NG2415055H; NG2415057H; NG2415060H; NG2415061H; NG2415063H; NG2415065H; NG2415069H; NG2415071H; NG2415072H; NG2415075H; NG2415077H; NG2415078H; NG2415079H; NG2415081H; NG2415083H; NG2415084H; NG2415086H; NG2415096H; NG2415099H; NG2415100H; NG2415101H; NG2415103H; NG2415105H; NG2415106H; NG2415107H; NG2415108H; NG2415109H; NG2415110H; NG2415111H; NG2415112H; NG2415113H; NG2415117H; NG2415122H; NG2415126H; NG2415129H; NG2415131H; NG2417504H; NG2417616H; NG2417623H; NG2417624H; NG2417647H; NG2417649H; NG2417666H; NG2417671H; NG2417720H; NG2417722H; NG2417729H; NG2417745H; NG2417768H; NG2417816H; NG2417820H; NG2417824H; NG2417834H; NG2417872H; NG2417875H; NG2417877H; NG2417880H; NG2417884H; NG2417887H; NG2417961H; NG2418034H; NG2418231H; NG2418233H; NG2418240H; NG2418241H; NG2418243H; NG2418260H; NG2418265H; NG2418281H; NG2418288H; NG2418386H; NG2418388H; NG2418394H; NG2418397H; NG2418399H; NG2418457H; NG2418459H; NG2418463H; NG2418472H; NG2418478H; NG2418535H; NG2418536H; NG2418545H; NG2418553H; NG2418881H; NG2418889H; NG2418891H; NG2418893H; NG2418894H; NG2418928H; NG2418932H; NG2418938H; NG2418946H; NG2418958H; NG2418966H; NG2418978H; NG2418985H; NG2418987H; NG2419007H; NG2419063H; NG2419064H; NG2419066H; NG2419068H; NG2419075H; NG2419682H; NG2419759H; NG2419912H; NG2419918H; NG2419921H; NG2419923H; NG2420391H; NG2420393H; NG2420417H; NG2420453H; NG2420478H; NG2420510H; NG2420579H; NG2420580H; NG2420586H; NG2420589H; NG2420633H; NG2420965H; NG2421114H; NG2421138H; NG2421150H; NG2421181H; NG2421204H; NG2421205H; NG2421209H; NG2421212H; NG2421213H; NG2421218H; NG2421219H; NG2421224H; NG2421225H; NG2421229H; NG2421231H; NG2421232H; NG2421233H; NG2421234H; NG2421238H; NG2421239H; NG2421242H; NG2421243H; NG2421254H; NG2421273H; NG2421294H; NG2421297H; NG2421353H; NG2421355H; NG2421361H; NG2421367H; NG2421438H; NG2421448H; NG2421465H; NG2421478H; NG2421499H; NG2421524H; NG2421525H; NG2421530H; NG2421566H; NG2421617H; NG2421639H; NG2421661H; NG2421667H; NG2421705H; NG2421706H; NG2421727H; NG2422092H; NG2422125H; NG2422291H; NG2422324H; NG2422436H; NG2422726H; NG2423503H; NG2423510H; NG2423579H; NG2423591H; NG2423666H; NG2423680H; NG2423765H; NG2423816H; NG2423972H; NG2423983H; NG2423988H; NG2424000H; NG2424011H; NG2424016H; NG2424048H; NG2424051H; NG2424055H; NG2424060H; NG2424103H; NG2424142H; NG2424144H; NG2424157H; NG2424159H; NG2424183H; NG2424186H; NG2424189H; NG2424258H; NG2424455H; NG2424481H; NG2424482H; NG2424495H; NG2424497H; NG2424498H; NG2424505H; NG2424506H; NG2424511H; NG2424529H; NG2424546H; NG2424547H; NG2424565H; NG2424567H; NG2424570H; NG2424576H; NG2424581H; NG2424583H; NG2424590H; NG2424607H; NG2424609H; NG2424628H; NG2424629H; NG2424639H; NG2424642H; NG2424646H; NG2424658H; NG2424668H; NG2424671H; NG2424672H; NG2424673H; NG2424680H; NG2424718H; NG2424721H; NG2424722H; NG2424726H; NG2424730H; NG2424732H; NG2424735H; NG2424747H; NG2424788H; NG2424793H; NG2424796H; NG2424818H; NG2424821H; NG2424822H; NG2424827H; NG2424829H; NG2424830H; NG2424835H; NG2424836H; NG2424849H; NG2424855H; NG2424866H; NG2424868H; NG2424869H; NG2424901H; NG2424903H; NG2424918H; NG2424922H; NG2424944H; NG2424945H; NG2424947H; NG2424959H; NG2424960H; NG2424963H; NG2424971H; NG2424973H; NG2424978H; NG2424983H; NG2424984H; NG2424989H; NG2424990H; NG2424992H; NG2424993H; NG2424997H; NG2424999H; NG2425000H; NG2425011H; NG2425015H; NG2425019H; NG2425032H; NG2425047H; NG2425050H; NG2425051H; NG2425058H; NG2425059H; NG2425060H; NG2425061H; NG2425075H; NG2425078H; NG2425091H; NG2425093H; NG2425095H; NG2425097H; NG2425100H; NG2425102H; NG2425117H; NG2425131H; NG2425132H; NG2425135H; NG2425136H; NG2425142H; NG2425147H; NG2425151H; NG2425158H; NG2425159H; NG2425166H; NG2425167H; NG2425169H; NG2425171H; NG2425172H; NG2425185H; NG2425200H; NG2425207H; NG2425209H; NG2425212H; NG2425216H; NG2425222H; NG2425228H; NG2425236H; NG2425240H; NG2425243H; NG2425372H; NG2425702H; NG2426818H; NG2428171H; NG2428174H; NG2429483H; NG2429500H; NG2429506H; NG2429517H; NG2429521H; NG2429532H; NG2429534H; NG2429540H; NG2429563H; NG2429569H; NG2429581H; NG2429583H; NG2430981H; NG2430986H; NG2431017H; NG2431047H; NG2431050H; NG2431070H; NG2432176H; NG2432183H; NG2432192H; NG2432197H; NG2432238H; NG2432239H; NG2432274H; NG2432278H; NG2432326H; NG2432330H; NG2432335H; NG2432337H; NG2432348H; NG2432349H; NG2432361H; NG2432368H; NG2432371H; NG2432373H; NG2432378H; NG2432380H; NG2432386H; NG2432388H; NG2432409H; NG2432418H; NG2432430H; NG2432434H; NG2432435H; NG2432439H; NG2432446H; NG2432459H; NG2432471H; NG2432479H; NG2432488H; NG2432494H; NG2432496H; NG2432508H; NG2432510H; NG2432519H; NG2432521H; NG2432525H; NG2432528H; NG2432541H; NG2432552H; NG2432571H; NG2432579H; NG2432582H; NG2432586H; NG2432607H; NG2432668H; NG2432671H; NG2432678H; NG2432705H; NG2432722H; NG2432730H; NG2432770H; NG2432773H; NG2432800H; NG2432809H; NG2432818H; NG2432839H; NG2432857H; NG2432866H; NG2432870H; NG2432890H; NG2432900H; NG2432918H; NG2432919H; NG2432920H; NG2432978H; NG2433006H; NG2433017H; NG2433104H; NG2433107H; NG2433116H; NG2433122H; NG2433145H; NG2433151H; NG2433154H; NG2433162H; NG2433166H; NG2433169H; NG2433175H; NG2433176H; NG2433178H; NG2433209H; NG2433233H; NG2433237H; NG2433252H; NG2433278H; NG2433281H; NG2433309H; NG2433328H; NG2433329H; NG2433434H; NG2433598H; NG2433605H; NG2433623H; NG2433647H; NG2433682H; NG2433743H; NG2433753H; NG2433809H; NG2433822H; NG2433925H; NG2433964H; NG2433992H; NG2434020H; NG2434024H; NG2434027H; NG2434032H; NG2434034H; NG2434037H; NG2434044H; NG2434059H; NG2434067H; NG2434072H; NG2434076H; NG2434081H; NG2434117H; NG2434128H; NG2434175H; NG2434178H; NG2434180H; NG2434184H; NG2434262H; NG2434266H; NG2434282H; NG2434287H; NG2434294H; NG2434317H; NG2434322H; NG2434329H; NG2434456H; NG2434458H; NG2434527H; NG2434547H; NG2434573H; NG2434684H; NG2434685H; NG2434688H; NG2434691H; NG2434712H; NG2434713H; NG2434717H; NG2434732H; NG2434753H; NG2434761H; NG2434763H; NG2434810H; NG2434811H; NG2434815H; NG2434816H; NG2434826H; NG2434852H; NG2434856H; NG2434873H; NG2434895H; NG2434899H; NG2434905H; NG2434919H; NG2434927H; NG2434938H; NG2434964H; NG2434983H; NG2434984H; NG2434990H; NG2434993H; NG2435003H; NG2435009H; NG2435017H; NG2435034H; NG2435039H; NG2435043H; NG2435059H; NG2435069H; NG2435092H; NG2435103H; NG2435105H; NG2435116H; NG2435117H; NG2435133H; NG2435140H; NG2435157H; NG2435161H; NG2435228H; NG2435231H; NG2435263H; NG2435266H; NG2435273H; NG2435307H; NG2435311H; NG2435316H; NG2435319H; NG2435323H; NG2435329H; NG2435333H; NG2435335H; NG2435344H; NG2435345H; NG2435354H; NG2435364H; NG2435382H; NG2435383H; NG2435384H; NG2435386H; NG2435398H; NG2435424H; NG2435426H; NG2435429H; NG2435430H; NG2435455H; NG2435512H; NG2435517H; NG2435522H; NG2435542H; NG2435545H; NG2435563H; NG2435565H; NG2435572H; NG2435575H; NG2435626H; NG2435633H; NG2435637H; NG2435646H; NG2435648H; NG2435655H; NG2435656H; NG2435660H; NG2435705H; NG2435709H; NG2435713H; NG2435716H; NG2435725H; NG2435729H; NG2435731H; NG2435735H; NG2435739H; NG2435741H; NG2435766H; NG2435767H; NG2435769H; NG2435770H; NG2435772H; NG2435773H; NG2435777H; NG2435779H; NG2435785H; NG2435788H; NG2435789H; NG2435791H; NG2435792H; NG2435793H; NG2435794H; NG2435795H; NG2435796H; NG2435869H; NG2435872H; NG2435894H; NG2435904H; NG2435906H; NG2435910H; NG2435915H; NG2435917H; NG2435918H; NG2435927H; NG2435928H; NG2435933H; NG2435944H; NG2435948H; NG2435950H; NG2435955H; NG2435956H; NG2435958H; NG2435960H; NG2435963H; NG2435964H; NG2435965H; NG2435966H; NG2435967H; NG2435970H; NG2435975H; NG2435977H; NG2436025H; NG2436028H; NG2436044H; NG2436047H; NG2436048H; NG2436055H; NG2436056H; NG2436059H; NG2436061H; NG2436065H; NG2436068H; NG2436070H; NG2436071H; NG2436073H; NG2436075H; NG2436078H; NG2436084H; NG2436091H; NG2436094H; NG2436095H; NG2436096H; NG2436097H; NG2436112H; NG2436114H; NG2436117H; NG2436187H; NG2436197H; NG2436207H; NG2436228H; NG2436247H; NG2436248H; NG2436251H; NG2436255H; NG2436257H; NG2436261H; NG2436290H; NG2436299H; NG2436348H; NG2436360H; NG2436369H; NG2436370H; NG2436375H; NG2436378H; NG2436384H; NG2436393H; NG2436394H; NG2436398H; NG2436399H; NG2436409H; NG2436410H; NG2436412H; NG2436423H; NG2436426H; NG2436431H; NG2436434H; NG2436435H; NG2436438H; NG2436439H; NG2436446H; NG2436448H; NG2436473H; NG2436480H; NG2436484H; NG2436486H; NG2436488H; NG2436491H; NG2436514H; NG2436516H; NG2436518H; NG2436520H; NG2436526H; NG2436532H; NG2436535H; NG2436536H; NG2436538H; NG2436539H; NG2436543H; NG2436545H; NG2436567H; NG2436606H; NG2436638H; NG2436667H; NG2436687H; NG2436715H; NG2436761H; NG2436769H; NG2436775H; NG2436780H; NG2436792H; NG2436797H; NG2436817H; NG2436818H; NG2436823H; NG2436825H; NG2436830H; NG2436832H; NG2436867H; NG2436868H; NG2436869H; NG2436875H; NG2436879H; NG2436894H; NG2436897H; NG2436902H; NG2436903H; NG2436905H; NG2436906H; NG2436915H; NG2436925H; NG2436954H; NG2436956H; NG2436961H; NG2436963H; NG2436964H; NG2436969H; NG2436977H; NG2436984H; NG2437014H; NG2437016H; NG2437020H; NG2437021H; NG2437024H; NG2437029H; NG2437030H; NG2437051H; NG2437052H; NG2437054H; NG2437056H; NG2437057H; NG2437059H; NG2437069H; NG2437077H; NG2437088H; NG2437089H; NG2437091H; NG2437099H; NG2437103H; NG2437123H; NG2437126H; NG2437137H; NG2437140H; NG2437176H; NG2437185H; NG2437187H; NG2437202H; NG2437204H; NG2437208H; NG2437223H; NG2437226H; NG2437253H; NG2437255H; NG2437257H; NG2437267H; NG2437277H; NG2437292H; NG2437316H; NG2437323H; NG2437325H; NG2437327H; NG2437342H; NG2437361H; NG2437423H; NG2437435H; NG2437530H; NG2437539H; NG2437554H; NG2437940H; NG2466697H; NG2466726H; NG2467096H; NG2467127H; NG2467172H; NG2476518H; NG2476560H; NG2482285H; NG2482556H; NG2482935H; NG2483309H; NG2483321H; NG2483322H; NG2483324H; NG2483326H; NG2483329H; NG2483336H; NG2483338H; NG2483343H; NG2483344H; NG2483348H; NG2483352H; NG2483356H; NG2483359H; NG2483363H; NG2483365H; NG2483375H; NG2483378H; NG2483389H; NG2483421H; NG2483423H; NG2483427H; NG2483441H; NG2483444H; NG2483450H; NG2483470H; NG2483473H; NG2483477H; NG2483479H; NG2483481H; NG2483487H; NG2483489H; NG2483491H; NG2483493H; NG2483495H; NG2483497H; NG2483500H; NG2483503H; NG2483506H; NG2483509H; NG2483511H; NG2483513H; NG2483553H; NG2483556H; NG2483557H; NG2483558H; NG2483559H; NG2483560H; NG2483561H; NG2483562H; NG2483565H; NG2483566H; NG2483567H; NG2483568H; NG2483569H; NG2483570H; NG2483574H; NG2483576H; NG2483579H; NG2483584H; NG2483586H; NG2483588H; NG2483589H; NG2483593H; NG2483595H; NG2483607H; NG2483608H; NG2483612H; NG2483621H; NG2483622H; NG2483623H; NG2483630H; NG2483631H; NG2483632H; NG2483642H; NG2483643H; NG2483650H; NG2483651H; NG2483653H; NG2483656H; NG2483663H; NG2483665H; NG2483670H; NG2483672H; NG2483674H; NG2483676H; NG2483681H; NG2483686H; NG2483687H; NG2483690H; NG2483691H; NG2483692H; NG2483700H; NG2483701H; NG2483702H; NG2483704H; NG2483706H; NG2483708H; NG2483709H; NG2483710H; NG2483712H; NG2483713H; NG2483714H; NG2483716H; NG2483717H; NG2483718H; NG2483720H; NG2483722H; NG2483724H; NG2483726H; NG2483729H; NG2483730H; NG2483732H; NG2483733H; NG2483735H; NG2483736H; NG2483742H; NG2483744H; NG2483745H; NG2483746H; NG2483747H; NG2483751H; NG2483754H; NG2483756H; NG2483758H; NG2483761H; NG2483764H; NG2483766H; NG2483767H; NG2483768H; NG2483769H; NG2483771H; NG2483772H; NG2483775H; NG2483776H; NG2483777H; NG2483785H; NG2483786H; NG2483787H; NG2483792H; NG2483820H; NG2483914H; NG2484006H; NG2484027H; NG2484229H; NG2484329H; NG2484596H; NG2484627H; NG2484633H; NG2484635H; NG2484650H; NG2484666H; NG2484668H; NG2357586H; NG2357676H; NG2357689H; NG2357691H; NG2357711H; NG2357743H; NG2357776H; NG2357836H; NG2357870H; NG2357873H; NG2358173H; NG2358195H; NG2358197H; NG2358199H; NG2358206H; NG2358227H; NG2358229H; NG2358240H; NG2358278H; NG2358296H; NG2358301H; NG2358310H; NG2358317H; NG2358324H; NG2358327H; NG2358341H; NG2358343H; NG2358357H; NG2358398H; NG2358414H; NG2358431H; NG2358432H; NG2358449H; NG2358470H; NG2358478H; NG2358502H; NG2358504H; NG2358540H; NG2359638H; NG2359702H; NG2359705H; NG2359707H; NG2359709H; NG2359711H; NG2359745H; NG2372637H; NG2373244H; NG2373272H; NG2373343H; NG2373428H; NG2373460H; NG2374926H; NG2374966H; NG2374990H; NG2375012H; NG2375439H; NG2375457H; NG2375463H; NG2375600H; NG2375604H; NG2375650H; NG2375652H; NG2375798H; NG2376158H; NG2376306H; NG2376314H; NG2376372H; NG2377584H; NG2377687H; NG2377727H; NG2377767H; NG2377891H; NG2377957H; NG2386292H; NG2386313H; NG2386372H; NG2386403H; NG2386439H; NG2396537H; NG2396583H; NG2396619H; NG2396643H; NG2396687H; NG2396697H; NG2396750H; NG2396766H; NG2396771H; NG2396837H; NG2396916H; NG2397031H; NG2397073H; NG2397088H; NG2397372H; NG2397610H; NG2397634H; NG2397657H; NG2397800H; NG2397838H; NG2397859H; NG2397978H; NG2397994H; NG2398000H; NG2402148H; NG2402246H; NG2402444H; NG2402545H; NG2402771H; NG2403116H; NG2403513H; NG2403527H; NG2403597H; NG2403654H; NG2403699H; NG2403739H; NG2403858H; NG2403864H; NG2403871H; NG2404034H; NG2404039H; NG2404073H; NG2404092H; NG2404102H; NG2404209H; NG2404357H; NG2404417H; NG2404494H; NG2404667H; NG2404695H; NG2404744H; NG2404746H; NG2404757H; NG2404775H; NG2404798H; NG2404808H; NG2404821H; NG2404866H; NG2404963H; NG2405122H; NG2405202H; NG2405214H; NG2405396H; NG2405545H; NG2405547H; NG2405715H; NG2405791H; NG2405867H; NG2406214H; NG2406820H; NG2406863H; NG2407005H; NG2407036H; NG2407051H; NG2407139H; NG2407141H; NG2407146H; NG2407172H; NG2407741H; NG2407743H; NG2407794H; NG2407797H; NG2407798H; NG2407804H; NG2407821H; NG2407914H; NG2408516H; NG2409980H; NG2410360H; NG2410528H; NG2410595H; NG2410675H; NG2410820H; NG2410829H; NG2411094H; NG2411178H; NG2411188H; NG2411198H; NG2411207H; NG2411227H; NG2411255H; NG2411278H; NG2411283H; NG2411473H; NG2411490H; NG2411526H; NG2411529H; NG2411546H; NG2411650H; NG2411742H; NG2412088H; NG2412349H; NG2412693H; NG2412695H; NG2412825H; NG2412964H; NG2413382H; NG2413421H; NG2413509H; NG2413515H; NG2413541H; NG2413581H; NG2413605H; NG2413627H; NG2413629H; NG2413845H; NG2413850H; NG2414013H; NG2414050H; NG2414060H; NG2414142H; NG2414161H; NG2414212H; NG2414224H; NG2414288H; NG2414502H; NG2414609H; NG2417477H; NG2417478H; NG2417480H; NG2417487H; NG2417488H; NG2417489H; NG2417495H; NG2417595H; NG2417622H; NG2417637H; NG2417704H; NG2417717H; NG2417750H; NG2418273H; NG2418453H; NG2418774H; NG2418779H; NG2418805H; NG2418896H; NG2418899H; NG2418903H; NG2418920H; NG2418927H; NG2419011H; NG2419014H; NG2419021H; NG2419023H; NG2419027H; NG2419032H; NG2419037H; NG2419040H; NG2419043H; NG2419045H; NG2419052H; NG2419053H; NG2419723H; NG2419728H; NG2419764H; NG2419767H; NG2419770H; NG2419774H; NG2419775H; NG2419816H; NG2419820H; NG2419824H; NG2419826H; NG2419827H; NG2419834H; NG2419853H; NG2419854H; NG2419905H; NG2419906H; NG2419907H; NG2419967H; NG2420078H; NG2420164H; NG2420178H; NG2420180H; NG2420184H; NG2420277H; NG2420358H; NG2420364H; NG2420377H; NG2420388H; NG2420401H; NG2420573H; NG2420613H; NG2420618H; NG2420722H; NG2420787H; NG2420797H; NG2420801H; NG2420805H; NG2420814H; NG2420815H; NG2420837H; NG2420849H; NG2420863H; NG2420875H; NG2420881H; NG2420882H; NG2420887H; NG2420888H; NG2420893H; NG2420927H; NG2420929H; NG2420935H; NG2421017H; NG2421068H; NG2421195H; NG2421244H; NG2421278H; NG2421324H; NG2421328H; NG2421329H; NG2421332H; NG2421338H; NG2421357H; NG2421364H; NG2421460H; NG2421469H; NG2421538H; NG2421612H; NG2421650H; NG2421704H; NG2421813H; NG2421833H; NG2421836H; NG2421850H; NG2421890H; NG2421905H; NG2421951H; NG2421957H; NG2421959H; NG2421964H; NG2422074H; NG2422080H; NG2422081H; NG2422117H; NG2422121H; NG2422138H; NG2422157H; NG2422190H; NG2422195H; NG2422253H; NG2422262H; NG2422287H; NG2422325H; NG2422336H; NG2422407H; NG2422410H; NG2422431H; NG2422467H; NG2422581H; NG2422608H; NG2422637H; NG2422673H; NG2422677H; NG2422686H; NG2422695H; NG2422718H; NG2422724H; NG2422738H; NG2422749H; NG2422768H; NG2422771H; NG2422795H; NG2422805H; NG2422818H; NG2422825H; NG2422826H; NG2422978H; NG2422982H; NG2422993H; NG2423011H; NG2423027H; NG2423154H; NG2423159H; NG2423178H; NG2423199H; NG2423263H; NG2423269H; NG2423275H; NG2423332H; NG2423334H; NG2423343H; NG2423372H; NG2423376H; NG2423440H; NG2423443H; NG2423448H; NG2423451H; NG2423531H; NG2423533H; NG2423538H; NG2423615H; NG2423645H; NG2423662H; NG2423664H; NG2423668H; NG2423674H; NG2423690H; NG2423710H; NG2423717H; NG2423735H; NG2423808H; NG2423837H; NG2423872H; NG2424006H; NG2424044H; NG2424050H; NG2424068H; NG2424110H; NG2424111H; NG2424132H; NG2424139H; NG2424161H; NG2424200H; NG2424202H; NG2424459H; NG2424510H; NG2424519H; NG2424531H; NG2424539H; NG2424549H; NG2424553H; NG2424556H; NG2424561H; NG2424563H; NG2424569H; NG2424572H; NG2424574H; NG2424578H; NG2424580H; NG2424695H; NG2424739H; NG2424774H; NG2424804H; NG2424857H; NG2424860H; NG2424893H; NG2424897H; NG2424899H; NG2424908H; NG2424921H; NG2424939H; NG2424948H; NG2424969H; NG2424988H; NG2424994H; NG2424996H; NG2425023H; NG2425027H; NG2425042H; NG2425044H; NG2425048H; NG2425067H; NG2425120H; NG2425139H; NG2425143H; NG2425184H; NG2425187H; NG2425206H; NG2425214H; NG2425215H; NG2425219H; NG2425221H; NG2425223H; NG2425226H; NG2425230H; NG2425231H; NG2425235H; NG2425239H; NG2425242H; NG2425356H; NG2425427H; NG2425606H; NG2425641H; NG2425646H; NG2425928H; NG2425966H; NG2425978H; NG2426376H; NG2426437H; NG2426487H; NG2426516H; NG2426544H; NG2426577H; NG2426620H; NG2426683H; NG2426804H; NG2426928H; NG2426933H; NG2427035H; NG2427036H; NG2427078H; NG2427123H; NG2427156H; NG2427161H; NG2427185H; NG2427186H; NG2427278H; NG2427311H; NG2427331H; NG2427344H; NG2427383H; NG2427401H; NG2427454H; NG2427525H; NG2427539H; NG2427543H; NG2427553H; NG2427587H; NG2427618H; NG2427625H; NG2427631H; NG2427678H; NG2427695H; NG2427751H; NG2427762H; NG2427782H; NG2427819H; NG2428020H; NG2428047H; NG2428127H; NG2428165H; NG2428173H; NG2428177H; NG2428179H; NG2428181H; NG2428218H; NG2428231H; NG2428257H; NG2428261H; NG2428289H; NG2428291H; NG2428312H; NG2428344H; NG2428351H; NG2428383H; NG2428391H; NG2428395H; NG2428416H; NG2428449H; NG2428472H; NG2428473H; NG2428479H; NG2428542H; NG2428551H; NG2428619H; NG2428644H; NG2428653H; NG2428656H; NG2428663H; NG2428686H; NG2428714H; NG2428756H; NG2428758H; NG2428766H; NG2428780H; NG2428795H; NG2428823H; NG2428831H; NG2428852H; NG2428880H; NG2428923H; NG2428924H; NG2428925H; NG2428930H; NG2428942H; NG2428975H; NG2429002H; NG2429009H; NG2429025H; NG2429030H; NG2429036H; NG2429068H; NG2429072H; NG2429074H; NG2429475H; NG2429488H; NG2429492H; NG2429493H; NG2429522H; NG2429524H; NG2429525H; NG2429562H; NG2429578H; NG2429580H; NG2429584H; NG2429590H; NG2430982H; NG2431055H; NG2431252H; NG2431302H; NG2431307H; NG2431423H; NG2431525H; NG2432168H; NG2432226H; NG2432280H; NG2432328H; NG2432345H; NG2432350H; NG2432353H; NG2432356H; NG2432376H; NG2432382H; NG2432617H; NG2432626H; NG2432627H; NG2432628H; NG2432760H; NG2433095H; NG2433142H; NG2433163H; NG2433194H; NG2433211H; NG2433230H; NG2433239H; NG2433243H; NG2433322H; NG2433364H; NG2433368H; NG2433413H; NG2433445H; NG2433494H; NG2433614H; NG2433620H; NG2433630H; NG2433639H; NG2433945H; NG2433982H; NG2434001H; NG2434082H; NG2434085H; NG2434098H; NG2434099H; NG2434143H; NG2434148H; NG2434169H; NG2434176H; NG2434219H; NG2434235H; NG2434260H; NG2434264H; NG2434301H; NG2434543H; NG2434544H; NG2434813H; NG2435107H; NG2435235H; NG2435348H; NG2435349H; NG2435395H; NG2435463H; NG2435467H; NG2435471H; NG2435529H; NG2435782H; NG2435892H; NG2435940H; NG2436090H; NG2436225H; NG2436227H; NG2436244H; NG2436297H; NG2436397H; NG2436401H; NG2436451H; NG2436478H; NG2436666H; NG2436819H; NG2436871H; NG2436922H; NG2437200H; NG2437228H; NG2437306H; NG2437345H; NG2437425H; NG2437946H; NG2437947H; NG2437970H; NG2437978H; NG2438008H; NG2438014H; NG2438043H; NG2438044H; NG2438050H; NG2438085H; NG2438089H; NG2438092H; NG2438094H; NG2438097H; NG2438101H; NG2438105H; NG2438120H; NG2438121H; NG2438122H; NG2438123H; NG2438125H; NG2438129H; NG2438130H; NG2438133H; NG2438141H; NG2438146H; NG2438188H; NG2438193H; NG2438214H; NG2438226H; NG2438233H; NG2438277H; NG2438281H; NG2438283H; NG2438285H; NG2438294H; NG2438295H; NG2438298H; NG2438310H; NG2438328H; NG2438330H; NG2438334H; NG2438337H; NG2438339H; NG2465299H; NG2465300H; NG2465306H; NG2465310H; NG2465315H; NG2465316H; NG2465320H; NG2465329H; NG2465331H; NG2465333H; NG2465340H; NG2465341H; NG2465418H; NG2465439H; NG2465441H; NG2465443H; NG2465444H; NG2465445H; NG2465447H; NG2465449H; NG2465452H; NG2465453H; NG2465454H; NG2465471H; NG2465473H; NG2465491H; NG2465493H; NG2465518H; NG2465522H; NG2465523H; NG2465524H; NG2465538H; NG2465547H; NG2465549H; NG2465582H; NG2465597H; NG2465601H; NG2465631H; NG2465685H; NG2465719H; NG2465724H; NG2465727H; NG2465746H; NG2465774H; NG2465777H; NG2465786H; NG2465801H; NG2465804H; NG2465847H; NG2465848H; NG2465849H; NG2465861H; NG2465900H; NG2465911H; NG2465914H; NG2465918H; NG2465942H; NG2465948H; NG2465949H; NG2465964H; NG2465968H; NG2465973H; NG2465990H; NG2466043H; NG2466052H; NG2466078H; NG2466087H; NG2466130H; NG2466131H; NG2466135H; NG2466141H; NG2466144H; NG2466185H; NG2466196H; NG2466199H; NG2466203H; NG2466219H; NG2466249H; NG2466279H; NG2466310H; NG2466332H; NG2466362H; NG2466365H; NG2466366H; NG2466373H; NG2466404H; NG2466433H; NG2466441H; NG2466449H; NG2466452H; NG2466454H; NG2466463H; NG2466498H; NG2466519H; NG2466545H; NG2466547H; NG2466566H; NG2466571H; NG2466593H; NG2466640H; NG2466649H; NG2466673H; NG2466688H; NG2466695H; NG2466701H; NG2466717H; NG2466817H; NG2466820H; NG2466824H; NG2466845H; NG2466877H; NG2466883H; NG2466886H; NG2466888H; NG2466892H; NG2466893H; NG2466915H; NG2466921H; NG2466927H; NG2466942H; NG2466944H; NG2466948H; NG2466982H; NG2466986H; NG2466989H; NG2466992H; NG2466993H; NG2467008H; NG2467013H; NG2467021H; NG2467032H; NG2467056H; NG2467080H; NG2467092H; NG2467108H; NG2467116H; NG2467121H; NG2467122H; NG2467123H; NG2467129H; NG2467131H; NG2467132H; NG2467135H; NG2467139H; NG2467140H; NG2467142H; NG2467159H; NG2467160H; NG2467163H; NG2467170H; NG2467201H; NG2467202H; NG2467204H; NG2467209H; NG2467212H; NG2467220H; NG2467222H; NG2467223H; NG2474758H; NG2474873H; NG2474889H; NG2474936H; NG2474940H; NG2474942H; NG2474985H; NG2474988H; NG2475003H; NG2475020H; NG2475053H; NG2475069H; NG2475072H; NG2475115H; NG2475140H; NG2475179H; NG2475293H; NG2475344H; NG2475363H; NG2475634H; NG2475636H; NG2475637H; NG2475648H; NG2475723H; NG2475758H; NG2475785H; NG2475796H; NG2475820H; NG2475872H; NG2475894H; NG2475898H; NG2475943H; NG2476020H; NG2476038H; NG2476042H; NG2476043H; NG2476044H; NG2476045H; NG2476051H; NG2476053H; NG2476055H; NG2476056H; NG2476057H; NG2476060H; NG2476061H; NG2476063H; NG2476064H; NG2476066H; NG2476067H; NG2476068H; NG2476069H; NG2476070H; NG2476072H; NG2476074H; NG2476075H; NG2476076H; NG2476078H; NG2476081H; NG2476084H; NG2476086H; NG2476087H; NG2476088H; NG2476089H; NG2476090H; NG2476092H; NG2476093H; NG2476094H; NG2476095H; NG2476097H; NG2476101H; NG2476105H; NG2476106H; NG2476113H; NG2476125H; NG2476130H; NG2476137H; NG2476141H; NG2476142H; NG2476143H; NG2476144H; NG2476145H; NG2476148H; NG2476150H; NG2476151H; NG2476152H; NG2476153H; NG2476154H; NG2476155H; NG2476158H; NG2476159H; NG2476164H; NG2476167H; NG2476174H; NG2476233H; NG2476235H; NG2476236H; NG2476237H; NG2476239H; NG2476240H; NG2476265H; NG2476267H; NG2476311H; NG2476312H; NG2476313H; NG2476314H; NG2476322H; NG2476323H; NG2476340H; NG2476341H; NG2476349H; NG2476352H; NG2476353H; NG2476363H; NG2476367H; NG2476368H; NG2476369H; NG2476370H; NG2476371H; NG2476372H; NG2476379H; NG2476380H; NG2476381H; NG2476384H; NG2476385H; NG2476407H; NG2476411H; NG2476412H; NG2476414H; NG2476416H; NG2476418H; NG2476422H; NG2476425H; NG2476434H; NG2476437H; NG2476443H; NG2476449H; NG2476454H; NG2476486H; NG2476488H; NG2476492H; NG2476493H; NG2482058H; NG2482069H; NG2482079H; NG2482080H; NG2482082H; NG2482087H; NG2482092H; NG2482094H; NG2482095H; NG2482108H; NG2482115H; NG2482121H; NG2482126H; NG2482129H; NG2482142H; NG2482148H; NG2482154H; NG2482155H; NG2482156H; NG2482161H; NG2482164H; NG2482174H; NG2482176H; NG2482206H; NG2482207H; NG2482208H; NG2482218H; NG2482246H; NG2482271H; NG2482279H; NG2482281H; NG2482294H; NG2482337H; NG2482344H; NG2482359H; NG2482361H; NG2482367H; NG2482371H; NG2482374H; NG2482401H; NG2482433H; NG2482513H; NG2482524H; NG2482586H; NG2482604H; NG2482615H; NG2482929H; NG2482933H; NG2482953H; NG2482971H; NG2482984H; NG2482998H; NG2483005H; NG2483011H; NG2483042H; NG2483082H; NG2483100H; NG2483108H; NG2483111H; NG2483119H; NG2483159H; NG2483170H; NG2483176H; NG2483178H; NG2483195H; NG2483208H; NG2483219H; NG2483316H; NG2483397H; NG2483454H; NG2483482H; NG2483551H; NG2483587H; NG2483598H; NG2483600H; NG2483601H; NG2483602H; NG2483606H; NG2483609H; NG2483610H; NG2483635H; NG2483637H; NG2483638H; NG2483639H; NG2483644H; NG2483647H; NG2483648H; NG2483655H; NG2483662H; NG2483667H; NG2483682H; NG2483688H; NG2483693H; NG2483694H; NG2483696H; NG2483698H; NG2483762H; NG2483794H; NG2483807H; NG2483893H; NG2483896H; NG2483899H; NG2483926H; NG2483943H; NG2483957H; NG2483967H; NG2484031H; NG2484044H; NG2484049H; NG2484062H; NG2484069H; NG2484070H; NG2484072H; NG2484078H; NG2484079H; NG2484085H; NG2484089H; NG2484091H; NG2484095H; NG2484211H; NG2484213H; NG2484214H; NG2484216H; NG2484217H; NG2484219H; NG2484226H; NG2484228H; NG2484230H; NG2484232H; NG2484233H; NG2484234H; NG2484237H; NG2484241H; NG2484243H; NG2484251H; NG2484252H; NG2484253H; NG2484254H; NG2484255H; NG2484257H; NG2484258H; NG2484265H; NG2484268H; NG2484280H; NG2484284H; NG2484300H; NG2484301H; NG2484304H; NG2484309H; NG2484310H; NG2484319H; NG2484325H; NG2484328H; NG2484331H; NG2484348H; NG2484352H; NG2484359H; NG2484366H; NG2484368H; NG2484373H; NG2484380H; NG2484398H; NG2484451H; NG2484453H; NG2484513H; NG2484567H; NG2484572H; NG2484576H; NG2484585H; NG2484603H; NG2484604H; NG2484655H; NG2484661H; NG2484667H; NG2484693H; NG2484698H; NG2484735H; NG2484767H; NG2484797H; NG2484818H; NG2484834H; NG2484875H; NG2484876H; NG2484883H; NG2484903H; NG2484904H; NG2484905H; NG2484922H; NG2484967H; NG2484968H; NG2484984H; NG2485004H; NG2485047H; NG2485048H; NG2485055H; NG2485057H; NG2485076H; NG2485091H; NG2485098H; NG2485112H; NG2485180H; NG2485182H; NG2485185H; NG2485187H; NG2485194H; NG2485201H; NG2485212H; NG2485216H; NG2485230H; NG2485233H; NG2485241H; NG2485247H; NG2485249H; NG2485250H; NG2485294H; NG2485295H; NG2485323H; NG2485333H; NG2485342H; NG2485343H; NG2485344H; NG2485356H; NG2485389H; NG2485401H; NG2485417H; NG2485428H; NG2485430H; NG2485432H; NG2485433H; NG2485467H; NG2485472H; NG2485494H; NG2485498H; NG2485528H; NG2485551H; NG2485599H; NG2485676H; NG2485696H; NG2485699H; NG2485724H; NG2485729H; NG2485731H; NG2485735H; NG2485827H; NG2485871H; NG2515499H; NG2515502H; NG2515509H; NG2515516H; NG2515525H; NG2515528H; NG2515563H; NG2515566H; NG2515595H; NG2515603H; NG2515604H; NG2515610H; NG2515613H; NG2515648H; NG2515649H; NG2515652H; NG2515654H; NG2515659H; NG2515688H; NG2515693H; NG2515703H; NG2517069H; NG2517107H; NG2517137H; NG2517175H; NG2517204H; NG2517206H; NG2517215H; NG2517248H; NG2517254H; NG2517255H; NG2517274H; NG2517286H; NG2517290H; NG2517371H; NG2517374H; NG2517375H; NG2517393H; NG2517443H; NG2517478H; NG2517516H; NG2517521H; NG2517610H; NG2517611H; NG2517620H; NG2517640H; NG2517641H; NG2517653H; NG2517660H; NG2517690H; NG2517692H; NG2517696H; NG2517720H; NG2517734H; NG2517735H; NG2517763H; NG2517782H; NG2517787H; NG2517789H; NG2517805H; NG2517806H; NG2517807H; NG2517808H; NG2517823H; NG2517876H; NG2517890H; NG2517911H; NG2517920H; NG2517943H; NG2517947H; NG2518044H; NG2518103H; NG2518108H; NG2518114H; NG2518127H; NG2518168H; NG2518172H; NG2518176H; NG2518180H; NG2518181H; NG2518195H; NG2518200H; NG2518229H; NG2518319H; NG2518351H; NG2518360H; NG2518417H; NG2518470H; NG2518473H; NG2518478H; NG2518497H; NG2518504H; NG2518532H; NG2518548H; NG2518567H; NG2518595H; NG2518675H; NG2518688H; NG2518689H; NG2518750H; NG1568972H; NG1570173H; NG1570375H; NG1570755H; NG1583844H; NG1586880H; NG1597902H; NG1661289H; NG1663249H; NG1715226H; NG1731830H; NG1731833H; NG1731917H; NG1731954H; NG1732015H; NG1732045H; NG1732102H; NG1732119H; NG1732133H; NG1732183H; NG1732186H; NG1732229H; NG1732392H; NG1732590H; NG1760350H; NG1769606H; NG1769643H; NG1769647H; NG1769655H; NG1769663H; NG1769679H; NG1769682H; NG1769707H; NG1769708H; NG1769712H; NG1769719H; NG1769732H; NG1769737H; NG1769748H; NG1769790H; NG1769791H; NG1769796H; NG1769800H; NG1769801H; NG1769826H; NG1769918H; NG1769953H; NG1769959H; NG1770949H; NG1806200H; NG1830201H; NG1836414H; NG1837391H; NG1850858H; NG1851999H; NG1857310H; NG1857611H; NG1868716H; NG1868837H; NG1880050H; NG1880551H; NG1881288H; NG1885071H; NG1885324H; NG1885952H; NG1892553H; NG1892710H; NG1893699H; NG1893700H; NG1893806H; NG1893914H; NG1893936H; NG1894871H; NG1895223H; NG1895571H; NG1895614H; NG1895664H; NG1895702H; NG1896172H; NG1909007H; NG1910491H; NG1924962H; NG1932186H; NG1938271H; NG1938436H; NG1938619H; NG1939503H; NG1951930H; NG1958952H; NG1959109H; NG1968795H; NG1971727H; NG2357438H; NG2357439H; NG2357547H; NG2357557H; NG2357636H; NG2357637H; NG2357681H; NG2357687H; NG2357693H; NG2357795H; NG2357801H; NG2357804H; NG2357820H; NG2357848H; NG2357866H; NG2357872H; NG2358145H; NG2358149H; NG2358191H; NG2358192H; NG2358193H; NG2358198H; NG2358200H; NG2358201H; NG2358203H; NG2358211H; NG2358220H; NG2358228H; NG2358234H; NG2358235H; NG2358236H; NG2358237H; NG2358238H; NG2358239H; NG2358241H; NG2358243H; NG2358254H; NG2358257H; NG2358258H; NG2358261H; NG2358263H; NG2358264H; NG2358268H; NG2358271H; NG2358280H; NG2358286H; NG2358287H; NG2358291H; NG2358313H; NG2358326H; NG2358338H; NG2358340H; NG2358345H; NG2358346H; NG2358347H; NG2358358H; NG2358359H; NG2358372H; NG2358397H; NG2358399H; NG2358401H; NG2358402H; NG2358411H; NG2358418H; NG2358420H; NG2358426H; NG2358428H; NG2358429H; NG2358435H; NG2358439H; NG2358448H; NG2358454H; NG2358455H; NG2358459H; NG2358467H; NG2358471H; NG2358472H; NG2358474H; NG2358479H; NG2358480H; NG2358482H; NG2358483H; NG2358484H; NG2358485H; NG2358486H; NG2358488H; NG2358490H; NG2358507H; NG2358509H; NG2358512H; NG2358513H; NG2358523H; NG2358529H; NG2358533H; NG2358535H; NG2358539H; NG2358541H; NG2359628H; NG2359630H; NG2359631H; NG2359632H; NG2359633H; NG2359635H; NG2359640H; NG2359642H; NG2359644H; NG2359646H; NG2359647H; NG2359649H; NG2359659H; NG2359668H; NG2359670H; NG2359672H; NG2359674H; NG2359675H; NG2359679H; NG2359684H; NG2359685H; NG2359687H; NG2359693H; NG2359696H; NG2359704H; NG2359706H; NG2359708H; NG2359716H; NG2359717H; NG2359718H; NG2359720H; NG2359728H; NG2359729H; NG2359731H; NG2359733H; NG2359735H; NG2359736H; NG2359737H; NG2359738H; NG2359740H; NG2359741H; NG2359742H; NG2359743H; NG2359744H; NG2359746H; NG2359748H; NG2359749H; NG2359750H; NG2359751H; NG2359753H; NG2359766H; NG2359775H; NG2359777H; NG2359780H; NG2359781H; NG2359783H; NG2372121H; NG2372442H; NG2372476H; NG2372488H; NG2372510H; NG2372517H; NG2372542H; NG2372555H; NG2372556H; NG2372558H; NG2372592H; NG2372624H; NG2372632H; NG2372635H; NG2372638H; NG2372639H; NG2372642H; NG2372662H; NG2372729H; NG2372734H; NG2372759H; NG2372766H; NG2372828H; NG2372868H; NG2372901H; NG2372902H; NG2372920H; NG2372924H; NG2372946H; NG2372986H; NG2373006H; NG2373012H; NG2373255H; NG2373266H; NG2373353H; NG2373356H; NG2373371H; NG2373382H; NG2373432H; NG2373436H; NG2373438H; NG2373440H; NG2373444H; NG2373448H; NG2373453H; NG2373461H; NG2373462H; NG2373467H; NG2374712H; NG2374748H; NG2374749H; NG2374771H; NG2374790H; NG2374800H; NG2374815H; NG2374816H; NG2374817H; NG2374818H; NG2374820H; NG2374822H; NG2374825H; NG2374859H; NG2374874H; NG2374886H; NG2374887H; NG2374919H; NG2374924H; NG2374928H; NG2374930H; NG2374943H; NG2374959H; NG2375006H; NG2375008H; NG2375011H; NG2375024H; NG2375075H; NG2375120H; NG2375121H; NG2375134H; NG2375135H; NG2375136H; NG2375140H; NG2375149H; NG2375162H; NG2375164H; NG2375166H; NG2375428H; NG2375431H; NG2375434H; NG2375443H; NG2375447H; NG2375462H; NG2375464H; NG2375483H; NG2375499H; NG2375501H; NG2375505H; NG2375528H; NG2375587H; NG2375643H; NG2375658H; NG2375664H; NG2375680H; NG2375683H; NG2375713H; NG2375746H; NG2375753H; NG2375830H; NG2375864H; NG2375873H; NG2375895H; NG2375930H; NG2375935H; NG2375948H; NG2375990H; NG2375991H; NG2376024H; NG2376052H; NG2376065H; NG2376125H; NG2376149H; NG2376150H; NG2376228H; NG2376242H; NG2376243H; NG2376383H; NG2376401H; NG2376431H; NG2376446H; NG2376448H; NG2376472H; NG2376480H; NG2376491H; NG2376493H; NG2376500H; NG2376501H; NG2376525H; NG2376534H; NG2376584H; NG2376609H; NG2376613H; NG2376624H; NG2376632H; NG2376663H; NG2376684H; NG2376868H; NG2376870H;
NG2376875H; NG2376880H; NG2376890H; NG2376897H; NG2376929H; NG2376935H; NG2376939H; NG2376965H; NG2376967H; NG2376973H; NG2376980H; NG2376985H; NG2377011H; NG2377012H; NG2377016H; NG2377026H; NG2377045H; NG2377050H; NG2377061H; NG2377065H; NG2377080H; NG2377090H; NG2377095H; NG2377096H; NG2377097H; NG2377099H; NG2377102H; NG2377108H; NG2377116H; NG2377127H; NG2377152H; NG2377153H; NG2377158H; NG2377165H; NG2377178H; NG2377199H; NG2377206H; NG2377251H; NG2377290H; NG2377331H; NG2377337H; NG2377338H; NG2377343H; NG2377345H; NG2377346H; NG2377351H; NG2377371H; NG2377399H; NG2377414H; NG2377418H; NG2377420H; NG2377431H; NG2377437H; NG2377438H; NG2377439H; NG2377442H; NG2377444H; NG2377487H; NG2377489H; NG2377490H; NG2377491H; NG2377493H; NG2377507H; NG2377510H; NG2377513H; NG2377522H; NG2377523H; NG2377524H; NG2377529H; NG2377538H; NG2377542H; NG2377543H; NG2377548H; NG2377549H; NG2377559H; NG2377583H; NG2377592H; NG2377600H; NG2377614H; NG2377621H; NG2377622H; NG2377623H; NG2377631H; NG2377634H; NG2377650H; NG2377656H; NG2377661H; NG2377674H; NG2377685H; NG2377689H; NG2377690H; NG2377691H; NG2377693H; NG2377725H; NG2377731H; NG2377735H; NG2377738H; NG2377746H; NG2377752H; NG2377755H; NG2377758H; NG2377774H; NG2377778H; NG2377781H; NG2377787H; NG2377798H; NG2377799H; NG2377800H; NG2377804H; NG2377819H; NG2377820H; NG2377821H; NG2377822H; NG2377823H; NG2377825H; NG2377826H; NG2377831H; NG2377833H; NG2377841H; NG2377843H; NG2377845H; NG2377852H; NG2377860H; NG2377865H; NG2377868H; NG2377881H; NG2377901H; NG2377910H; NG2377921H; NG2377928H; NG2377936H; NG2377943H; NG2377945H; NG2377949H; NG2377952H; NG2377953H; NG2377956H; NG2377960H; NG2377962H; NG2377963H; NG2377970H; NG2377973H; NG2377974H; NG2377980H; NG2377985H; NG2377987H; NG2377990H; NG2377991H; NG2377993H; NG2377995H; NG2377998H; NG2378000H; NG2378001H; NG2378003H; NG2378004H; NG2378008H; NG2378009H; NG2378010H; NG2378011H; NG2378012H; NG2378015H; NG2378016H; NG2378018H; NG2378019H; NG2378020H; NG2378022H; NG2378024H; NG2378027H; NG2378031H; NG2378038H; NG2378042H; NG2378045H; NG2378047H; NG2378049H; NG2378053H; NG2378054H; NG2378057H; NG2378058H; NG2378061H; NG2378064H; NG2378066H; NG2378070H; NG2378073H; NG2378074H; NG2378075H; NG2378076H; NG2378079H; NG2378092H; NG2378095H; NG2378101H; NG2378107H; NG2378108H; NG2378110H; NG2378115H; NG2378135H; NG2378140H; NG2378160H; NG2378185H; NG2378211H; NG2378213H; NG2378229H; NG2378233H; NG2378234H; NG2378248H; NG2378251H; NG2378286H; NG2378314H; NG2378316H; NG2378602H; NG2378605H; NG2378613H; NG2378619H; NG2378648H; NG2378650H; NG2378699H; NG2378722H; NG2378744H; NG2378748H; NG2378752H; NG2378759H; NG2378760H; NG2378761H; NG2378762H; NG2378763H; NG2378766H; NG2378772H; NG2378775H; NG2378800H; NG2378821H; NG2378826H; NG2378834H; NG2378837H; NG2378850H; NG2379089H; NG2379122H; NG2379124H; NG2379125H; NG2379126H; NG2379128H; NG2379129H; NG2379130H; NG2386297H; NG2386303H; NG2386307H; NG2386308H; NG2386311H; NG2386312H; NG2386316H; NG2386323H; NG2386324H; NG2386325H; NG2386327H; NG2386329H; NG2386332H; NG2386334H; NG2386335H; NG2386336H; NG2386358H; NG2386359H; NG2386365H; NG2386366H; NG2386367H; NG2386368H; NG2386370H; NG2386374H; NG2386377H; NG2386379H; NG2386380H; NG2386381H; NG2386382H; NG2386385H; NG2386387H; NG2386389H; NG2386394H; NG2386398H; NG2386407H; NG2386409H; NG2386411H; NG2386420H; NG2386421H; NG2386430H; NG2386432H; NG2386435H; NG2386437H; NG2386441H; NG2386446H; NG2386449H; NG2386450H; NG2386453H; NG2386457H; NG2386459H; NG2386461H; NG2386466H; NG2386467H; NG2386469H; NG2386473H; NG2386474H; NG2386476H; NG2386477H; NG2386480H; NG2386482H; NG2386486H; NG2386489H; NG2386493H; NG2386494H; NG2386502H; NG2386504H; NG2386506H; NG2386509H; NG2386514H; NG2386516H; NG2386517H; NG2386521H; NG2386523H; NG2386528H; NG2386529H; NG2386532H; NG2386533H; NG2386536H; NG2386540H; NG2386544H; NG2386562H; NG2386563H; NG2386567H; NG2386568H; NG2386569H; NG2386574H; NG2386578H; NG2386579H; NG2386585H; NG2386587H; NG2386589H; NG2386593H; NG2386606H; NG2386608H; NG2386610H; NG2386617H; NG2386618H; NG2386624H; NG2386625H; NG2386634H; NG2386635H; NG2386636H; NG2386645H; NG2386649H; NG2386651H; NG2386655H; NG2386657H; NG2396527H; NG2396529H; NG2396532H; NG2396535H; NG2396540H; NG2396543H; NG2396550H; NG2396560H; NG2396580H; NG2396584H; NG2396587H; NG2396597H; NG2396598H; NG2396601H; NG2396622H; NG2396630H; NG2396633H; NG2396634H; NG2396645H; NG2396655H; NG2396675H; NG2396676H; NG2396678H; NG2396679H; NG2396682H; NG2396683H; NG2396688H; NG2396705H; NG2396709H; NG2396714H; NG2396721H; NG2396725H; NG2396726H; NG2396728H; NG2396729H; NG2396730H; NG2396731H; NG2396736H; NG2396740H; NG2396758H; NG2396763H; NG2396769H; NG2396778H; NG2396779H; NG2396783H; NG2396788H; NG2396800H; NG2396811H; NG2396813H; NG2396815H; NG2396838H; NG2396841H; NG2396855H; NG2396856H; NG2396859H; NG2396869H; NG2396912H; NG2396922H; NG2396958H; NG2397016H; NG2397024H; NG2397048H; NG2397049H; NG2397050H; NG2397052H; NG2397068H; NG2397075H; NG2397076H; NG2397089H; NG2397102H; NG2397104H; NG2397106H; NG2397112H; NG2397117H; NG2397128H; NG2397130H; NG2397133H; NG2397137H; NG2397138H; NG2397143H; NG2397147H; NG2397150H; NG2397160H; NG2397166H; NG2397172H; NG2397180H; NG2397182H; NG2397186H; NG2397188H; NG2397194H; NG2397208H; NG2397210H; NG2397251H; NG2397262H; NG2397297H; NG2397303H; NG2397305H; NG2397310H; NG2397312H; NG2397327H; NG2397329H; NG2397353H; NG2397380H; NG2397382H; NG2397409H; NG2397415H; NG2397420H; NG2397429H; NG2397431H; NG2397439H; NG2397452H; NG2397461H; NG2397465H; NG2397478H; NG2397479H; NG2397481H; NG2397490H; NG2397509H; NG2397511H; NG2397525H; NG2397527H; NG2397529H; NG2397534H; NG2397540H; NG2397552H; NG2397569H; NG2397572H; NG2397573H; NG2397576H; NG2397577H; NG2397578H; NG2397580H; NG2397587H; NG2397589H; NG2397590H; NG2397603H; NG2397604H; NG2397606H; NG2397612H; NG2397613H; NG2397622H; NG2397636H; NG2397637H; NG2397649H; NG2397651H; NG2397668H; NG2397669H; NG2397672H; NG2397703H; NG2397705H; NG2397723H; NG2397726H; NG2397730H; NG2397733H; NG2397735H; NG2397742H; NG2397788H; NG2397793H; NG2397804H; NG2397810H; NG2397811H; NG2397812H; NG2397817H; NG2397818H; NG2397821H; NG2397826H; NG2397830H; NG2397837H; NG2397840H; NG2397841H; NG2397842H; NG2397843H; NG2397844H; NG2397851H; NG2397853H; NG2397856H; NG2397877H; NG2397878H; NG2397887H; NG2397890H; NG2397891H; NG2397895H; NG2397900H; NG2397901H; NG2397905H; NG2397916H; NG2397917H; NG2397918H; NG2397921H; NG2397926H; NG2397941H; NG2397943H; NG2397946H; NG2397948H; NG2397954H; NG2397955H; NG2397959H; NG2397960H; NG2397961H; NG2397977H; NG2397981H; NG2397990H; NG2398002H; NG2402118H; NG2402119H; NG2402145H; NG2402146H; NG2402147H; NG2402149H; NG2402150H; NG2402183H; NG2402185H; NG2402248H; NG2402253H; NG2402256H; NG2402290H; NG2402297H; NG2402309H; NG2402318H; NG2402327H; NG2402334H; NG2402336H; NG2402344H; NG2402353H; NG2402362H; NG2402371H; NG2402375H; NG2402378H; NG2402395H; NG2402403H; NG2402408H; NG2402418H; NG2402419H; NG2402425H; NG2402433H; NG2402434H; NG2402438H; NG2402443H; NG2402461H; NG2402468H; NG2402550H; NG2402552H; NG2402560H; NG2402568H; NG2402625H; NG2402631H; NG2402643H; NG2402662H; NG2402664H; NG2402688H; NG2402716H; NG2402724H; NG2402740H; NG2402752H; NG2402757H; NG2402761H; NG2402779H; NG2402787H; NG2402807H; NG2402809H; NG2402818H; NG2402819H; NG2402827H; NG2402829H; NG2402871H; NG2402878H; NG2402884H; NG2402898H; NG2402928H; NG2402930H; NG2402976H; NG2402984H; NG2402988H; NG2403023H; NG2403037H; NG2403087H; NG2403089H; NG2403097H; NG2403100H; NG2403104H; NG2403110H; NG2403139H; NG2403146H; NG2403147H; NG2403156H; NG2403157H; NG2403164H; NG2403459H; NG2403461H; NG2403465H; NG2403525H; NG2403530H; NG2403533H; NG2403547H; NG2403556H; NG2403561H; NG2403563H; NG2403575H; NG2403577H; NG2403580H; NG2403581H; NG2403585H; NG2403587H; NG2403629H; NG2403634H; NG2403637H; NG2403642H; NG2403643H; NG2403647H; NG2403650H; NG2403652H; NG2403662H; NG2403683H; NG2403685H; NG2403686H; NG2403696H; NG2403707H; NG2403710H; NG2403712H; NG2403713H; NG2403716H; NG2403720H; NG2403727H; NG2403740H; NG2403748H; NG2403753H; NG2403756H; NG2403758H; NG2403760H; NG2403767H; NG2403773H; NG2403774H; NG2403776H; NG2403777H; NG2403780H; NG2403783H; NG2403785H; NG2403788H; NG2403790H; NG2403835H; NG2403851H; NG2403857H; NG2403862H; NG2403863H; NG2403865H; NG2403867H; NG2403870H; NG2403873H; NG2403878H; NG2403886H; NG2403890H; NG2403895H; NG2403902H; NG2403906H; NG2403911H; NG2403916H; NG2403919H; NG2403922H; NG2403923H; NG2403939H; NG2403942H; NG2403943H; NG2404021H; NG2404027H; NG2404043H; NG2404044H; NG2404045H; NG2404047H; NG2404050H; NG2404051H; NG2404064H; NG2404069H; NG2404071H; NG2404072H; NG2404075H; NG2404076H; NG2404078H; NG2404082H; NG2404087H; NG2404090H; NG2404091H; NG2404094H; NG2404095H; NG2404097H; NG2404100H; NG2404114H; NG2404116H; NG2404125H; NG2404127H; NG2404128H; NG2404132H; NG2404135H; NG2404158H; NG2404162H; NG2404163H; NG2404164H; NG2404165H; NG2404167H; NG2404173H; NG2404177H; NG2404179H; NG2404181H; NG2404182H; NG2404183H; NG2404184H; NG2404185H; NG2404186H; NG2404188H; NG2404189H; NG2404191H; NG2404193H; NG2404204H; NG2404205H; NG2404206H; NG2404207H; NG2404208H; NG2404210H; NG2404212H; NG2404218H; NG2404224H; NG2404225H; NG2404226H; NG2404228H; NG2404229H; NG2404230H; NG2404231H; NG2404232H; NG2404233H; NG2404234H; NG2404235H; NG2404237H; NG2404240H; NG2404241H; NG2404242H; NG2404245H; NG2404247H; NG2404251H; NG2404253H; NG2404257H; NG2404261H; NG2404263H; NG2404266H; NG2404267H; NG2404268H; NG2404269H; NG2404270H; NG2404271H; NG2404291H; NG2404314H; NG2404327H; NG2404330H; NG2404331H; NG2404335H; NG2404337H; NG2404342H; NG2404385H; NG2404388H; NG2404391H; NG2404392H; NG2404393H; NG2404412H; NG2404435H; NG2404441H; NG2404444H; NG2404448H; NG2404459H; NG2404461H; NG2404484H; NG2404523H; NG2404551H; NG2404558H; NG2404568H; NG2404573H; NG2404601H; NG2404605H; NG2404610H; NG2404614H; NG2404618H; NG2404620H; NG2404622H; NG2404641H; NG2404642H; NG2404644H; NG2404648H; NG2404659H; NG2404660H; NG2404661H; NG2404662H; NG2404666H; NG2404668H; NG2404670H; NG2404673H; NG2404674H; NG2404676H; NG2404677H; NG2404678H; NG2404682H; NG2404696H; NG2404697H; NG2404699H; NG2404703H; NG2404706H; NG2404724H; NG2404725H; NG2404727H; NG2404729H; NG2404734H; NG2404736H; NG2404760H; NG2404763H; NG2404766H; NG2404769H; NG2404772H; NG2404784H; NG2404789H; NG2404790H; NG2404792H; NG2404793H; NG2404799H; NG2404801H; NG2404802H; NG2404811H; NG2404815H; NG2404816H; NG2404819H; NG2404822H; NG2404823H; NG2404825H; NG2404831H; NG2404835H; NG2404842H; NG2404844H; NG2404850H; NG2404851H; NG2404855H; NG2404857H; NG2404860H; NG2404861H; NG2404873H; NG2404875H; NG2404877H; NG2404879H; NG2404887H; NG2404888H; NG2404892H; NG2404894H; NG2404897H; NG2404898H; NG2404899H; NG2404955H; NG2404957H; NG2404961H; NG2404974H; NG2404993H; NG2405002H; NG2405124H; NG2405127H; NG2405131H; NG2405148H; NG2405154H; NG2405185H; NG2405191H; NG2405221H; NG2405222H; NG2405245H; NG2405258H; NG2405261H; NG2405267H; NG2405275H; NG2405291H; NG2405302H; NG2405331H; NG2405341H; NG2405345H; NG2405346H; NG2405356H; NG2405374H; NG2405398H; NG2405400H; NG2405417H; NG2405419H; NG2405439H; NG2405462H; NG2405465H; NG2405466H; NG2405469H; NG2405471H; NG2405473H; NG2405500H; NG2405508H; NG2405513H; NG2405518H; NG2405538H; NG2405542H; NG2405549H; NG2405557H; NG2405582H; NG2405585H; NG2405612H; NG2405618H; NG2405647H; NG2405651H; NG2405659H; NG2405668H; NG2405675H; NG2405679H; NG2405680H; NG2405688H; NG2405690H; NG2405706H; NG2405711H; NG2405784H; NG2405786H; NG2405788H; NG2405793H; NG2405795H; NG2405796H; NG2405798H; NG2405800H; NG2405801H; NG2405803H; NG2405808H; NG2405863H; NG2405886H; NG2405896H; NG2405898H; NG2405901H; NG2405930H; NG2405931H; NG2405933H; NG2405934H; NG2405937H; NG2405941H; NG2405943H; NG2405944H; NG2405946H; NG2405982H; NG2405993H; NG2406059H; NG2406063H; NG2406069H; NG2406079H; NG2406080H; NG2406185H; NG2406219H; NG2406232H; NG2406240H; NG2406244H; NG2406245H; NG2406258H; NG2406260H; NG2406261H; NG2406262H; NG2406263H; NG2406265H; NG2406286H; NG2406308H; NG2406312H; NG2406316H; NG2406322H; NG2406326H; NG2406334H; NG2406335H; NG2406338H; NG2406339H; NG2406340H; NG2406341H; NG2406343H; NG2406346H; NG2406347H; NG2406352H; NG2406358H; NG2406360H; NG2406362H; NG2406363H; NG2406364H; NG2406365H; NG2406378H; NG2406379H; NG2406387H; NG2406415H; NG2406471H; NG2406489H; NG2406501H; NG2406503H; NG2406545H; NG2406677H; NG2406706H; NG2406715H; NG2406736H; NG2406737H; NG2406747H; NG2406757H; NG2406764H; NG2406785H; NG2406835H; NG2406851H; NG2406862H; NG2406865H; NG2406867H; NG2406869H; NG2406895H; NG2406901H; NG2406903H; NG2406904H; NG2406905H; NG2406906H; NG2406907H; NG2406909H; NG2406910H; NG2406913H; NG2406920H; NG2406934H; NG2406935H; NG2406936H; NG2406952H; NG2406954H; NG2406955H; NG2406963H; NG2406964H; NG2406969H; NG2407002H; NG2407004H; NG2407008H; NG2407009H; NG2407010H; NG2407033H; NG2407050H; NG2407059H; NG2407071H; NG2407076H; NG2407085H; NG2407086H; NG2407088H; NG2407092H; NG2407098H; NG2407101H; NG2407107H; NG2407118H; NG2407119H; NG2407130H; NG2407134H; NG2407149H; NG2407151H; NG2407163H; NG2407174H; NG2407182H; NG2407186H; NG2407191H; NG2407192H; NG2407204H; NG2407213H; NG2407216H; NG2407217H; NG2407219H; NG2407257H; NG2407259H; NG2407269H; NG2407270H; NG2407296H; NG2407298H; NG2407299H; NG2407300H; NG2407301H; NG2407304H; NG2407306H; NG2407324H; NG2407326H; NG2407328H; NG2407400H; NG2407402H; NG2407404H; NG2407405H; NG2407455H; NG2407460H; NG2407470H; NG2407479H; NG2407484H; NG2407490H; NG2407492H; NG2407502H; NG2407545H; NG2407595H; NG2407610H; NG2407613H; NG2407631H; NG2407635H; NG2407689H; NG2407692H; NG2407735H; NG2407737H; NG2407744H; NG2407801H; NG2407803H; NG2407838H; NG2407869H; NG2407882H; NG2407969H; NG2407971H; NG2407973H; NG2407979H; NG2407984H; NG2407985H; NG2408005H; NG2408113H; NG2408156H; NG2408276H; NG2408394H; NG2408520H; NG2408535H; NG2408558H; NG2408562H; NG2408584H; NG2408586H; NG2408589H; NG2408603H; NG2408607H; NG2408676H; NG2408717H; NG2408844H; NG2408845H; NG2408852H; NG2408855H; NG2408862H; NG2408864H; NG2408870H; NG2408876H; NG2408899H; NG2408915H; NG2408941H; NG2408946H; NG2408952H; NG2408957H; NG2408970H; NG2408972H; NG2409014H; NG2409018H; NG2409021H; NG2409023H; NG2409024H; NG2409026H; NG2409027H; NG2409032H; NG2409042H; NG2409044H; NG2409046H; NG2409052H; NG2409056H; NG2409061H; NG2409141H; NG2409142H; NG2409145H; NG2409147H; NG2409150H; NG2409153H; NG2409158H; NG2409160H; NG2409162H; NG2409164H; NG2409176H; NG2409183H; NG2409187H; NG2409189H; NG2409190H; NG2409192H; NG2409193H; NG2409194H; NG2409196H; NG2409198H; NG2409199H; NG2409201H; NG2409203H; NG2409204H; NG2409206H; NG2409220H; NG2409223H; NG2409229H; NG2409236H; NG2409238H; NG2409240H; NG2409243H; NG2409244H; NG2409245H; NG2409313H; NG2409323H; NG2409324H; NG2409327H; NG2409330H; NG2409335H; NG2409349H; NG2409367H; NG2409369H; NG2409382H; NG2409393H; NG2409395H; NG2409398H; NG2409404H; NG2409412H; NG2409423H; NG2409426H; NG2409431H; NG2409433H; NG2409507H; NG2409509H; NG2409511H; NG2409515H; NG2409530H; NG2409534H; NG2409535H; NG2409537H; NG2409549H; NG2409554H; NG2409558H; NG2409561H; NG2409566H; NG2409582H; NG2409597H; NG2409613H; NG2409636H; NG2409638H; NG2409640H; NG2409641H; NG2409642H; NG2409643H; NG2409653H; NG2409660H; NG2409663H; NG2409664H; NG2409674H; NG2409681H; NG2409687H; NG2409691H; NG2409692H; NG2409701H; NG2409705H; NG2409707H; NG2409713H; NG2409720H; NG2409722H; NG2409724H; NG2409725H; NG2409727H; NG2409728H; NG2409791H; NG2409792H; NG2409793H; NG2409805H; NG2409808H; NG2409835H; NG2409840H; NG2409842H; NG2409848H; NG2409934H; NG2409969H; NG2409972H; NG2409973H; NG2409976H; NG2409977H; NG2410034H; NG2410037H; NG2410046H; NG2410096H; NG2410099H; NG2410116H; NG2410128H; NG2410271H; NG2410272H; NG2410273H; NG2410361H; NG2410364H; NG2410369H; NG2410375H; NG2410377H; NG2410382H; NG2410395H; NG2410478H; NG2410480H; NG2410484H; NG2410486H; NG2410489H; NG2410491H; NG2410509H; NG2410523H; NG2410532H; NG2410590H; NG2410638H; NG2410640H; NG2410642H; NG2410645H; NG2410648H; NG2410650H; NG2410652H; NG2410666H; NG2410669H; NG2410672H; NG2410685H; NG2410686H; NG2410688H; NG2410691H; NG2410693H; NG2410701H; NG2410706H; NG2410712H; NG2410715H; NG2410759H; NG2410768H; NG2410773H; NG2410777H; NG2410782H; NG2410784H; NG2410788H; NG2410803H; NG2410816H; NG2410818H; NG2410823H; NG2411118H; NG2411124H; NG2411130H; NG2411139H; NG2411156H; NG2411165H; NG2411212H; NG2411218H; NG2411221H; NG2411223H; NG2411232H; NG2411237H; NG2411242H; NG2411253H; NG2411264H; NG2411269H; NG2411279H; NG2411298H; NG2411300H; NG2411301H; NG2411316H; NG2411469H; NG2411532H; NG2411539H; NG2411541H; NG2411542H; NG2411558H; NG2411567H; NG2411577H; NG2411584H; NG2411630H; NG2411641H; NG2411645H; NG2411647H; NG2411653H; NG2411665H; NG2411699H; NG2411703H; NG2411711H; NG2411717H; NG2411728H; NG2411732H; NG2411738H; NG2411745H; NG2411785H; NG2411789H; NG2411791H; NG2411800H; NG2411852H; NG2411866H; NG2411922H; NG2411926H; NG2411928H; NG2411932H; NG2411936H; NG2411939H; NG2411947H; NG2411960H; NG2411977H; NG2411995H; NG2412017H; NG2412020H; NG2412058H; NG2412067H; NG2412070H; NG2412082H; NG2412083H; NG2412102H; NG2412112H; NG2412123H; NG2412178H; NG2412185H; NG2412190H; NG2412197H; NG2412222H; NG2412280H; NG2412284H; NG2412306H; NG2412311H; NG2412313H; NG2412323H; NG2412330H; NG2412335H; NG2412342H; NG2412350H; NG2412355H; NG2412380H; NG2412385H; NG2412386H; NG2412431H; NG2412432H; NG2412434H; NG2412436H; NG2412452H; NG2412454H; NG2412456H; NG2412471H; NG2412475H; NG2412482H; NG2412500H; NG2412502H; NG2412503H; NG2412506H; NG2412508H; NG2412512H; NG2412513H; NG2412522H; NG2412525H; NG2412536H; NG2412544H; NG2412549H; NG2412551H; NG2412558H; NG2412560H; NG2412561H; NG2412564H; NG2412565H; NG2412600H; NG2412601H; NG2412676H; NG2412678H; NG2412683H; NG2412684H; NG2412696H; NG2412705H; NG2412715H; NG2412719H; NG2412730H; NG2412732H; NG2412747H; NG2412749H; NG2412758H; NG2412768H; NG2412769H; NG2412771H; NG2412787H; NG2412789H; NG2412795H; NG2412800H; NG2412812H; NG2412815H; NG2412820H; NG2412822H; NG2412827H; NG2412832H; NG2412838H; NG2412840H; NG2412841H; NG2412844H; NG2412849H; NG2412851H; NG2412856H; NG2412859H; NG2412907H; NG2412910H; NG2412913H; NG2412958H; NG2413052H; NG2413059H; NG2413061H; NG2413062H; NG2413103H; NG2413107H; NG2413110H; NG2413116H; NG2413120H; NG2413123H; NG2413125H; NG2413127H; NG2413128H; NG2413133H; NG2413138H; NG2413143H; NG2413155H; NG2413156H; NG2413160H; NG2413166H; NG2413196H; NG2413198H; NG2413207H; NG2413212H; NG2413215H; NG2413222H; NG2413235H; NG2413237H; NG2413244H; NG2413255H; NG2413256H; NG2413257H; NG2413260H; NG2413335H; NG2413337H; NG2413340H; NG2413368H; NG2413377H; NG2413379H; NG2413380H; NG2413384H; NG2413392H; NG2413411H; NG2413415H; NG2413418H; NG2413419H; NG2413487H; NG2413494H; NG2413538H; NG2413545H; NG2413568H; NG2413586H; NG2413612H; NG2413617H; NG2413634H; NG2413636H; NG2413651H; NG2413668H; NG2413819H; NG2413821H; NG2413842H; NG2413852H; NG2413856H; NG2413911H; NG2413923H; NG2413928H; NG2413944H; NG2413945H; NG2413946H; NG2413950H; NG2413960H; NG2413993H; NG2413996H; NG2413997H; NG2414001H; NG2414008H; NG2414011H; NG2414042H; NG2414046H; NG2414061H; NG2414071H; NG2414080H; NG2414081H; NG2414087H; NG2414089H; NG2414090H; NG2414119H; NG2414121H; NG2414123H; NG2414149H; NG2414154H; NG2414171H; NG2414175H; NG2414178H; NG2414181H; NG2414213H; NG2414214H; NG2414246H; NG2414284H; NG2414297H; NG2414303H; NG2414307H; NG2414311H; NG2414317H; NG2414326H; NG2414412H; NG2414413H; NG2414438H; NG2414440H; NG2414443H; NG2414475H; NG2414477H; NG2414487H; NG2414511H; NG2414538H; NG2414558H; NG2414564H; NG2414569H; NG2414594H; NG2414595H; NG2414625H; NG2414642H; NG2414667H; NG2414673H; NG2414680H; NG2414686H; NG2414688H; NG2414690H; NG2414708H; NG2414736H; NG2414749H; NG2414759H; NG2414790H; NG2414792H; NG2414838H; NG2414899H; NG2414987H; NG2417479H; NG2417483H; NG2417484H; NG2417486H; NG2417494H; NG2417591H; NG2417592H; NG2417594H; NG2417602H; NG2417604H; NG2417611H; NG2417612H; NG2417617H; NG2417620H; NG2417621H; NG2417625H; NG2417639H; NG2417641H; NG2417645H; NG2417648H; NG2417654H; NG2417658H; NG2417659H; NG2417661H; NG2417663H; NG2417668H; NG2417674H; NG2417676H; NG2417677H; NG2417680H; NG2417683H; NG2417684H; NG2417686H; NG2417695H; NG2417697H; NG2417698H; NG2417702H; NG2417707H; NG2417709H; NG2417721H; NG2417723H; NG2417725H; NG2417728H; NG2417730H; NG2417731H; NG2417740H; NG2417755H; NG2417756H; NG2417757H; NG2417769H; NG2417786H; NG2417792H; NG2417796H; NG2417797H; NG2417818H; NG2417821H; NG2417822H; NG2417823H; NG2417829H; NG2417831H; NG2417836H; NG2417838H; NG2417843H; NG2417866H; NG2417867H; NG2417873H; NG2417882H; NG2417888H; NG2417904H; NG2417943H; NG2417956H; NG2417958H; NG2417963H; NG2418004H; NG2418006H; NG2418008H; NG2418009H; NG2418015H; NG2418016H; NG2418019H; NG2418020H; NG2418021H; NG2418025H; NG2418028H; NG2418030H; NG2418032H; NG2418036H; NG2418037H; NG2418038H; NG2418039H; NG2418040H; NG2418041H; NG2418048H; NG2418050H; NG2418057H; NG2418067H; NG2418070H; NG2418073H; NG2418074H; NG2418084H; NG2418092H; NG2418095H; NG2418096H; NG2418122H; NG2418123H; NG2418126H; NG2418128H; NG2418130H; NG2418140H; NG2418143H; NG2418173H; NG2418179H; NG2418181H; NG2418182H; NG2418183H; NG2418185H; NG2418188H; NG2418190H; NG2418221H; NG2418226H; NG2418263H; NG2418271H; NG2418279H; NG2418283H; NG2418290H; NG2418292H; NG2418384H; NG2418401H; NG2418402H; NG2418407H; NG2418408H; NG2418409H; NG2418413H; NG2418415H; NG2418422H; NG2418445H; NG2418454H; NG2418455H; NG2418462H; NG2418468H; NG2418470H; NG2418475H; NG2418476H; NG2418480H; NG2418483H; NG2418485H; NG2418488H; NG2418495H; NG2418497H; NG2418499H; NG2418500H; NG2418505H; NG2418509H; NG2418511H; NG2418513H; NG2418515H; NG2418520H; NG2418523H; NG2418527H; NG2418532H; NG2418547H; NG2418550H; NG2418551H; NG2418558H; NG2418561H; NG2418562H; NG2418579H; NG2418580H; NG2418582H; NG2418584H; NG2418585H; NG2418586H; NG2418587H; NG2418695H; NG2418698H; NG2418702H; NG2418705H; NG2418706H; NG2418720H; NG2418722H; NG2418726H; NG2418727H; NG2418751H; NG2418753H; NG2418764H; NG2418767H; NG2418771H; NG2418778H; NG2418781H; NG2418783H; NG2418788H; NG2418800H; NG2418838H; NG2418848H; NG2418853H; NG2418855H; NG2418869H; NG2418873H; NG2418875H; NG2418877H; NG2418895H; NG2419018H; NG2419028H; NG2419034H; NG2419039H; NG2419041H; NG2419079H; NG2419091H; NG2419094H; NG2419232H; NG2419684H; NG2419686H; NG2419692H; NG2419694H; NG2419708H; NG2419711H; NG2419716H; NG2419739H; NG2419742H; NG2419757H; NG2419760H; NG2419761H; NG2419762H; NG2419763H; NG2419805H; NG2419807H; NG2419812H; NG2419814H; NG2419815H; NG2419829H; NG2419830H; NG2419832H; NG2419833H; NG2419852H; NG2419857H; NG2419863H; NG2419864H; NG2419867H; NG2419869H; NG2419870H; NG2419871H; NG2419873H; NG2419875H; NG2419876H; NG2419878H; NG2419880H; NG2419889H; NG2419892H; NG2419893H; NG2419896H; NG2419910H; NG2419915H; NG2419924H; NG2419927H; NG2419943H; NG2419944H; NG2419945H; NG2419946H; NG2419947H; NG2419949H; NG2419951H; NG2419952H; NG2419955H; NG2419968H; NG2419970H; NG2419971H; NG2419976H; NG2419977H; NG2419981H; NG2419982H; NG2419983H; NG2419984H; NG2419987H; NG2420007H; NG2420008H; NG2420009H; NG2420011H; NG2420012H; NG2420014H; NG2420015H; NG2420016H; NG2420031H; NG2420036H; NG2420037H; NG2420038H; NG2420039H; NG2420040H; NG2420044H; NG2420051H; NG2420055H; NG2420060H; NG2420062H; NG2420066H; NG2420067H; NG2420068H; NG2420072H; NG2420080H; NG2420081H; NG2420082H; NG2420083H; NG2420084H; NG2420091H; NG2420094H; NG2420105H; NG2420106H; NG2420108H; NG2420115H; NG2420129H; NG2420135H; NG2420138H; NG2420142H; NG2420149H; NG2420157H; NG2420162H; NG2420169H; NG2420182H; NG2420190H; NG2420195H; NG2420198H; NG2420200H; NG2420203H; NG2420207H; NG2420208H; NG2420209H; NG2420214H; NG2420215H; NG2420221H; NG2420225H; NG2420237H; NG2420238H; NG2420240H; NG2420243H; NG2420248H; NG2420255H; NG2420265H; NG2420270H; NG2420349H; NG2420365H; NG2420371H; NG2420390H; NG2420392H; NG2420394H; NG2420420H; NG2420423H; NG2420427H; NG2420430H; NG2420432H; NG2420434H; NG2420446H; NG2420448H; NG2420455H; NG2420461H; NG2420471H; NG2420472H; NG2420479H; NG2420482H; NG2420485H; NG2420489H; NG2420491H; NG2420494H; NG2420495H; NG2420498H; NG2420499H; NG2420500H; NG2420506H; NG2420583H; NG2420588H; NG2420610H; NG2420619H; NG2420622H; NG2420639H; NG2420643H; NG2420644H; NG2420646H; NG2420649H; NG2420650H; NG2420651H; NG2420669H; NG2420673H; NG2420676H; NG2420678H; NG2420682H; NG2420683H; NG2420685H; NG2420700H; NG2420703H; NG2420708H; NG2420709H; NG2420710H; NG2420712H; NG2420715H; NG2420719H; NG2420720H; NG2420724H; NG2420731H; NG2420817H; NG2420839H; NG2420841H; NG2420860H; NG2420872H; NG2420890H; NG2420891H; NG2420901H; NG2420908H; NG2420909H; NG2420915H; NG2420916H; NG2420920H; NG2420928H; NG2420966H; NG2420997H; NG2421002H; NG2421003H; NG2421006H; NG2421029H; NG2421030H; NG2421057H; NG2421065H; NG2421074H; NG2421075H; NG2421076H; NG2421080H; NG2421105H; NG2421108H; NG2421118H; NG2421124H; NG2421126H; NG2421133H; NG2421135H; NG2421136H; NG2421137H; NG2421142H; NG2421144H; NG2421146H; NG2421147H; NG2421149H; NG2421153H; NG2421155H; NG2421158H; NG2421166H; NG2421167H; NG2421169H; NG2421171H; NG2421172H; NG2421173H; NG2421174H; NG2421175H; NG2421182H; NG2421183H; NG2421189H; NG2421193H; NG2421197H; NG2421203H; NG2421221H; NG2421247H; NG2421251H; NG2421252H; NG2421253H; NG2421255H; NG2421256H; NG2421258H; NG2421271H; NG2421275H; NG2421276H; NG2421295H; NG2421301H; NG2421305H; NG2421307H; NG2421327H; NG2421330H; NG2421333H; NG2421334H; NG2421335H; NG2421336H; NG2421340H; NG2421352H; NG2421354H; NG2421356H; NG2421363H; NG2421366H; NG2421375H; NG2421378H; NG2421381H; NG2421387H; NG2421395H; NG2421397H; NG2421399H; NG2421435H; NG2421436H; NG2421437H; NG2421439H; NG2421440H; NG2421443H; NG2421447H; NG2421451H; NG2421461H; NG2421464H; NG2421466H; NG2421467H; NG2421468H; NG2421471H; NG2421479H; NG2421480H; NG2421482H; NG2421483H; NG2421485H; NG2421490H; NG2421492H; NG2421495H; NG2421497H; NG2421504H; NG2421509H; NG2421511H; NG2421513H; NG2421515H; NG2421517H; NG2421518H; NG2421519H; NG2421522H; NG2421523H; NG2421531H; NG2421548H; NG2421557H; NG2421563H; NG2421630H; NG2421634H; NG2421642H; NG2421647H; NG2421657H; NG2421666H; NG2421685H; NG2421686H; NG2421687H; NG2421688H; NG2421700H; NG2421703H; NG2421709H; NG2421733H; NG2421740H; NG2421744H; NG2421750H; NG2421759H; NG2421762H; NG2421774H; NG2421778H; NG2421784H; NG2421788H; NG2421797H; NG2421804H; NG2421808H; NG2421815H; NG2421831H; NG2421835H; NG2421838H; NG2421839H; NG2421842H; NG2421848H; NG2421852H; NG2421854H; NG2421857H; NG2421860H; NG2421868H; NG2421875H; NG2421878H; NG2421880H; NG2421885H; NG2421888H; NG2421891H; NG2421892H; NG2421895H; NG2421897H; NG2421903H; NG2421908H; NG2421912H; NG2421922H; NG2421925H; NG2421933H; NG2421937H; NG2421942H; NG2421948H; NG2421955H; NG2421970H; NG2421974H; NG2421982H; NG2421985H; NG2422024H; NG2422030H; NG2422035H; NG2422041H; NG2422043H; NG2422044H; NG2422046H; NG2422047H; NG2422076H; NG2422079H; NG2422083H; NG2422086H; NG2422090H; NG2422095H; NG2422103H; NG2422104H; NG2422105H; NG2422119H; NG2422123H; NG2422144H; NG2422160H; NG2422250H; NG2422265H; NG2422267H; NG2422269H; NG2422275H; NG2422277H; NG2422289H; NG2422295H; NG2422302H; NG2422317H; NG2422323H; NG2422326H; NG2422327H; NG2422328H; NG2422378H; NG2422384H; NG2422395H; NG2422397H; NG2422402H; NG2422413H; NG2422417H; NG2422427H; NG2422429H; NG2422445H; NG2422451H; NG2422454H; NG2422456H; NG2422459H; NG2422471H; NG2422472H; NG2422476H; NG2422490H; NG2422491H; NG2422494H; NG2422497H; NG2422499H; NG2422552H; NG2422557H; NG2422566H; NG2422600H; NG2422615H; NG2422643H; NG2422653H; NG2422657H; NG2422658H; NG2422670H; NG2422679H; NG2422699H; NG2422703H; NG2422710H; NG2422735H; NG2422741H; NG2422747H; NG2422773H; NG2422783H; NG2422785H; NG2422788H; NG2422803H; NG2422808H; NG2422811H; NG2422821H; NG2422828H; NG2422845H; NG2422855H; NG2422858H; NG2422864H; NG2422865H; NG2422868H; NG2422869H; NG2422872H; NG2422876H; NG2422887H; NG2422891H; NG2422897H; NG2422898H; NG2422946H; NG2422954H; NG2422963H; NG2422968H; NG2422984H; NG2422986H; NG2422996H; NG2422999H; NG2423004H; NG2423010H; NG2423014H; NG2423022H; NG2423029H; NG2423032H; NG2423039H; NG2423043H; NG2423046H; NG2423055H; NG2423066H; NG2423074H; NG2423091H; NG2423103H; NG2423105H; NG2423113H; NG2423149H; NG2423151H; NG2423175H; NG2423197H; NG2423201H; NG2423202H; NG2423261H; NG2423267H; NG2423282H; NG2423292H; NG2423295H; NG2423311H; NG2423318H; NG2423320H; NG2423322H; NG2423324H; NG2423328H; NG2423330H; NG2423336H; NG2423353H; NG2423362H; NG2423368H; NG2423370H; NG2423378H; NG2423379H; NG2423411H; NG2423412H; NG2423417H; NG2423420H; NG2423424H; NG2423426H; NG2423427H; NG2423429H; NG2423431H; NG2423433H; NG2423436H; NG2423445H; NG2423450H; NG2423489H; NG2423490H; NG2423495H; NG2423498H; NG2423499H; NG2423506H; NG2423523H; NG2423535H; NG2423536H; NG2423541H; NG2423555H; NG2423565H; NG2423569H; NG2423573H; NG2423584H; NG2423585H; NG2423592H; NG2423602H; NG2423603H; NG2423608H; NG2423634H; NG2423637H; NG2423638H; NG2423640H; NG2423642H; NG2423646H; NG2423647H; NG2423648H; NG2423649H; NG2423663H; NG2423667H; NG2423669H; NG2423675H; NG2423676H; NG2423693H; NG2423712H; NG2423718H; NG2423726H; NG2423734H; NG2423737H; NG2423744H; NG2423747H; NG2423748H; NG2423760H; NG2423766H; NG2423767H; NG2423776H; NG2423777H; NG2423780H; NG2423794H; NG2423795H; NG2423814H; NG2423819H; NG2423821H; NG2423829H; NG2423831H; NG2423843H; NG2423867H; NG2423876H; NG2423880H; NG2423937H; NG2423939H; NG2423940H; NG2423942H; NG2423946H; NG2423953H; NG2423970H; NG2423977H; NG2424019H; NG2424024H; NG2424049H; NG2424052H; NG2424053H; NG2424054H; NG2424063H; NG2424104H; NG2424137H; NG2424152H; NG2424153H; NG2424160H; NG2424169H; NG2424171H; NG2424176H; NG2424185H; NG2424207H; NG2424219H; NG2424251H; NG2424262H; NG2424264H; NG2424268H; NG2424275H; NG2424277H; NG2424395H; NG2424397H; NG2424400H; NG2424461H; NG2424469H; NG2424472H; NG2424473H; NG2424478H; NG2424479H; NG2424487H; NG2424492H; NG2424501H; NG2424502H; NG2424507H; NG2424509H; NG2424512H; NG2424513H; NG2424515H; NG2424521H; NG2424526H; NG2424528H; NG2424530H; NG2424535H; NG2424537H; NG2424541H; NG2424543H; NG2424548H; NG2424557H; NG2424589H; NG2424605H; NG2424616H; NG2424619H; NG2424633H; NG2424649H; NG2424651H; NG2424654H; NG2424675H; NG2424676H; NG2424681H; NG2424687H; NG2424689H; NG2424704H; NG2424719H; NG2424720H; NG2424742H; NG2424744H; NG2424745H; NG2424749H; NG2424751H; NG2424752H; NG2424754H; NG2424765H; NG2424766H; NG2424768H; NG2424771H; NG2424777H; NG2424779H; NG2424800H; NG2424802H; NG2424805H; NG2424807H; NG2424809H; NG2424812H; NG2424814H; NG2424816H; NG2424820H; NG2424823H; NG2424826H; NG2424832H; NG2424833H; NG2424837H; NG2424839H; NG2424870H; NG2424871H; NG2424872H; NG2424873H; NG2424889H; NG2424892H; NG2424898H; NG2424904H; NG2424905H; NG2424907H; NG2424930H; NG2424935H; NG2424938H; NG2424946H; NG2424955H; NG2424961H; NG2424964H; NG2424965H; NG2424967H; NG2424974H; NG2424975H; NG2424977H; NG2424979H; NG2424980H; NG2424986H; NG2424987H; NG2424995H; NG2425001H; NG2425021H; NG2425034H; NG2425038H; NG2425039H; NG2425040H; NG2425052H; NG2425062H; NG2425063H; NG2425064H; NG2425065H; NG2425066H; NG2425069H; NG2425070H; NG2425073H; NG2425074H; NG2425076H; NG2425077H; NG2425082H; NG2425083H; NG2425084H; NG2425085H; NG2425087H; NG2425088H; NG2425090H; NG2425113H; NG2425122H; NG2425124H; NG2425125H; NG2425126H; NG2425134H; NG2425137H; NG2425145H; NG2425149H; NG2425156H; NG2425160H; NG2425162H; NG2425163H; NG2425168H; NG2425170H; NG2425173H; NG2425188H; NG2425195H; NG2425203H; NG2425205H; NG2425210H; NG2425220H; NG2425224H; NG2425233H; NG2425237H; NG2425249H; NG2425253H; NG2425297H; NG2425299H; NG2425302H; NG2425305H; NG2425307H; NG2425310H; NG2425312H; NG2425319H; NG2425321H; NG2425326H; NG2425327H; NG2425331H; NG2425339H; NG2425340H; NG2425343H; NG2425345H; NG2425350H; NG2425376H; NG2425377H; NG2425378H; NG2425380H; NG2425402H; NG2425414H; NG2425449H; NG2425455H; NG2425468H; NG2425479H; NG2425500H; NG2425523H; NG2425530H; NG2425531H; NG2425532H; NG2425535H; NG2425552H; NG2425559H; NG2425562H; NG2425563H; NG2425565H; NG2425569H; NG2425570H; NG2425571H; NG2425572H; NG2425575H; NG2425576H; NG2425578H; NG2425580H; NG2425594H; NG2425607H; NG2425609H; NG2425623H; NG2425624H; NG2425630H; NG2425632H; NG2425636H; NG2425647H; NG2425653H; NG2425654H; NG2425668H; NG2425722H; NG2425729H; NG2425733H; NG2425738H; NG2425739H; NG2425740H; NG2425742H; NG2425751H; NG2425770H; NG2425860H; NG2425866H; NG2425868H; NG2425874H; NG2425878H; NG2425879H; NG2425900H; NG2425908H; NG2425912H; NG2425915H; NG2425919H; NG2425924H; NG2425934H; NG2425935H; NG2425936H; NG2425938H; NG2425941H; NG2425944H; NG2425945H; NG2425946H; NG2425948H; NG2425951H; NG2425952H; NG2425962H; NG2425963H; NG2425964H; NG2425967H; NG2425970H; NG2425972H; NG2425983H; NG2425986H; NG2425989H; NG2425993H; NG2425994H; NG2425996H; NG2426003H; NG2426006H; NG2426280H; NG2426290H; NG2426296H; NG2426306H; NG2426310H; NG2426325H; NG2426328H; NG2426333H; NG2426337H; NG2426343H; NG2426355H; NG2426365H; NG2426370H; NG2426374H; NG2426384H; NG2426405H; NG2426458H; NG2426459H; NG2426464H; NG2426467H; NG2426473H; NG2426475H; NG2426483H; NG2426493H; NG2426495H; NG2426499H; NG2426501H; NG2426505H; NG2426520H; NG2426525H; NG2426534H; NG2426540H; NG2426548H; NG2426552H; NG2426554H; NG2426557H; NG2426560H; NG2426563H; NG2426574H; NG2426598H; NG2426608H; NG2426619H; NG2426621H; NG2426667H; NG2426668H; NG2426669H; NG2426672H; NG2426679H; NG2426692H; NG2426702H; NG2426750H; NG2426757H; NG2426775H; NG2426777H; NG2426779H; NG2426788H; NG2426792H; NG2426809H; NG2426810H; NG2426811H; NG2426812H; NG2426820H; NG2426826H; NG2426827H; NG2426832H; NG2426850H; NG2426866H; NG2426868H; NG2426869H; NG2426873H; NG2426882H; NG2426883H; NG2426935H; NG2426937H; NG2426938H; NG2426939H; NG2426943H; NG2426951H; NG2426955H; NG2426957H; NG2426962H; NG2426964H; NG2427013H; NG2427025H; NG2427030H; NG2427032H; NG2427041H; NG2427061H; NG2427074H; NG2427093H; NG2427097H; NG2427099H; NG2427102H; NG2427105H; NG2427119H; NG2427121H; NG2427127H; NG2427136H; NG2427157H; NG2427166H; NG2427167H; NG2427168H; NG2427194H; NG2427224H; NG2427259H; NG2427263H; NG2427274H; NG2427281H; NG2427282H; NG2427284H; NG2427290H; NG2427291H; NG2427316H; NG2427319H; NG2427324H; NG2427332H; NG2427347H; NG2427349H; NG2427367H; NG2427377H; NG2427385H; NG2427394H; NG2427424H; NG2427429H; NG2427431H; NG2427434H; NG2427443H; NG2427467H; NG2427472H; NG2427479H; NG2427528H; NG2427531H; NG2427541H; NG2427557H; NG2427559H; NG2427563H; NG2427564H; NG2427588H; NG2427591H; NG2427604H; NG2427608H; NG2427613H; NG2427623H; NG2427624H; NG2427628H; NG2427629H; NG2427634H; NG2427645H; NG2427655H; NG2427657H; NG2427661H; NG2427664H; NG2427665H; NG2427668H; NG2427669H; NG2427673H; NG2427674H; NG2427677H; NG2427679H; NG2427680H; NG2427681H; NG2427683H; NG2427685H; NG2427690H; NG2427696H; NG2427697H; NG2427705H; NG2427706H; NG2427708H; NG2427715H; NG2427718H; NG2427741H; NG2427750H; NG2427752H; NG2427770H; NG2427775H; NG2427779H; NG2427809H; NG2427810H; NG2427811H; NG2427814H; NG2427854H; NG2427966H; NG2427969H; NG2427971H; NG2427977H; NG2427979H; NG2427980H; NG2427989H; NG2427993H; NG2428008H; NG2428012H; NG2428013H; NG2428027H; NG2428029H; NG2428031H; NG2428034H; NG2428041H; NG2428043H; NG2428045H; NG2428048H; NG2428050H; NG2428055H; NG2428058H; NG2428060H; NG2428063H; NG2428065H; NG2428066H; NG2428072H; NG2428082H; NG2428106H; NG2428122H; NG2428123H; NG2428124H; NG2428129H; NG2428132H; NG2428137H; NG2428144H; NG2428166H; NG2428168H; NG2428170H; NG2428176H; NG2428200H; NG2428225H; NG2428230H; NG2428251H; NG2428252H; NG2428256H; NG2428262H; NG2428266H; NG2428271H; NG2428275H; NG2428281H; NG2428290H; NG2428293H; NG2428294H; NG2428302H; NG2428303H; NG2428305H; NG2428309H; NG2428352H; NG2428353H; NG2428355H; NG2428363H; NG2428365H; NG2428378H; NG2428385H; NG2428388H; NG2428393H; NG2428404H; NG2428422H; NG2428424H; NG2428445H; NG2428465H; NG2428468H; NG2428475H; NG2428484H; NG2428508H; NG2428545H; NG2428549H; NG2428557H; NG2428579H; NG2428581H; NG2428587H; NG2428589H; NG2428590H; NG2428591H; NG2428621H; NG2428624H; NG2428625H; NG2428638H; NG2428640H; NG2428643H; NG2428647H; NG2428648H; NG2428651H; NG2428673H; NG2428678H; NG2428679H; NG2428685H; NG2428689H; NG2428694H; NG2428696H; NG2428707H; NG2428708H; NG2428713H; NG2428749H; NG2428759H; NG2428762H; NG2428767H; NG2428768H; NG2428769H; NG2428770H; NG2428771H; NG2428773H; NG2428778H; NG2428790H; NG2428791H; NG2428792H; NG2428793H; NG2428797H; NG2428804H; NG2428829H; NG2428848H; NG2428856H; NG2428863H; NG2428881H; NG2428883H; NG2428895H; NG2428902H; NG2428918H; NG2428920H; NG2428922H; NG2428934H; NG2428947H; NG2428950H; NG2428955H; NG2428959H; NG2428963H; NG2428971H; NG2428972H; NG2428974H; NG2428976H; NG2428977H; NG2428986H; NG2428996H; NG2429017H; NG2429021H; NG2429022H; NG2429024H; NG2429028H; NG2429033H; NG2429040H; NG2429041H; NG2429043H; NG2429049H; NG2429058H; NG2429069H; NG2429070H; NG2429076H; NG2429077H; NG2429078H; NG2429082H; NG2429464H; NG2429465H; NG2429470H; NG2429486H; NG2429487H; NG2429490H; NG2429491H; NG2429495H; NG2429496H; NG2429502H; NG2429504H; NG2429511H; NG2429515H; NG2429519H; NG2429520H; NG2429526H; NG2429528H; NG2429530H; NG2429533H; NG2429536H; NG2429537H; NG2429539H; NG2429555H; NG2429560H; NG2429564H; NG2429567H; NG2429571H; NG2429573H; NG2429579H; NG2429585H; NG2429586H; NG2429587H; NG2429588H; NG2429589H; NG2430985H; NG2430989H; NG2431031H; NG2431065H; NG2431069H; NG2431075H; NG2431080H; NG2431098H; NG2431102H; NG2431103H; NG2431118H; NG2431119H; NG2431122H; NG2431148H; NG2431157H; NG2431164H; NG2431167H; NG2431168H; NG2431169H; NG2431171H; NG2431172H; NG2431185H; NG2431192H; NG2431208H; NG2431209H; NG2431212H; NG2431214H; NG2431215H; NG2431216H; NG2431217H; NG2431219H; NG2431220H; NG2431221H; NG2431224H; NG2431225H; NG2431226H; NG2431228H; NG2431230H; NG2431231H; NG2431233H; NG2431235H; NG2431236H; NG2431238H; NG2431239H; NG2431244H; NG2431253H; NG2431254H; NG2431281H; NG2431284H; NG2431285H; NG2431303H; NG2431304H; NG2431305H; NG2431306H; NG2431327H; NG2431329H; NG2431331H; NG2431332H; NG2431340H; NG2431344H; NG2431348H; NG2431362H; NG2431371H; NG2431389H; NG2431392H; NG2431393H; NG2431394H; NG2431399H; NG2431402H; NG2431409H; NG2431415H; NG2431419H; NG2431421H; NG2431428H; NG2431432H; NG2431434H; NG2431438H; NG2431440H; NG2431459H; NG2431467H; NG2431479H; NG2431483H; NG2431484H; NG2431514H; NG2431516H; NG2431519H; NG2431526H; NG2431534H; NG2431537H; NG2431549H; NG2431550H; NG2431551H; NG2431580H; NG2431653H; NG2431655H; NG2431657H; NG2431658H; NG2431660H; NG2431661H; NG2431663H; NG2431664H; NG2431666H; NG2431667H; NG2431669H; NG2431670H; NG2431671H; NG2431675H; NG2431692H; NG2431693H; NG2431711H; NG2431714H; NG2431715H; NG2431716H; NG2431718H; NG2431719H; NG2431721H; NG2431722H; NG2431724H; NG2431726H; NG2431727H; NG2431728H; NG2431729H; NG2431730H; NG2431734H; NG2431736H; NG2431743H; NG2431751H; NG2431752H; NG2431764H; NG2431765H; NG2431769H; NG2431776H; NG2431777H; NG2431780H; NG2431781H; NG2431782H; NG2431783H; NG2431784H; NG2431788H; NG2431798H; NG2431800H; NG2431806H; NG2431811H; NG2431819H; NG2431824H; NG2431826H; NG2431829H; NG2431830H; NG2431833H; NG2431852H; NG2431853H; NG2431855H; NG2431983H; NG2431984H; NG2431987H; NG2431989H; NG2431991H; NG2431993H; NG2432089H; NG2432090H; NG2432091H; NG2432097H; NG2432101H; NG2432102H; NG2432103H; NG2432105H; NG2432142H; NG2432146H; NG2432150H; NG2432154H; NG2432165H; NG2432178H; NG2432187H; NG2432211H; NG2432223H; NG2432229H; NG2432231H; NG2432232H; NG2432276H; NG2432281H; NG2432333H; NG2432338H; NG2432355H; NG2432363H; NG2432396H; NG2432404H; NG2432412H; NG2432424H; NG2432426H; NG2432428H; NG2432432H; NG2432438H; NG2432448H; NG2432498H; NG2432507H; NG2432518H; NG2432549H; NG2432550H; NG2432555H; NG2432577H; NG2432580H; NG2432595H; NG2432599H; NG2432638H; NG2432663H; NG2432670H; NG2432677H; NG2432697H; NG2432734H; NG2432776H; NG2432788H; NG2432791H; NG2432796H; NG2432827H; NG2432841H; NG2432852H; NG2432860H; NG2432863H; NG2432868H; NG2432873H; NG2432880H; NG2432885H; NG2432887H; NG2432893H; NG2432895H; NG2432916H; NG2432922H; NG2432987H; NG2433019H; NG2433064H; NG2433073H; NG2433079H; NG2433083H; NG2433098H; NG2433113H; NG2433119H; NG2433126H; NG2433137H; NG2433159H; NG2433160H; NG2433165H; NG2433173H; NG2433185H; NG2433189H; NG2433191H; NG2433193H; NG2433195H; NG2433204H; NG2433219H; NG2433223H; NG2433235H; NG2433241H; NG2433248H; NG2433275H; NG2433284H; NG2433286H; NG2433312H; NG2433313H; NG2433314H; NG2433318H; NG2433321H; NG2433327H; NG2433357H; NG2433359H; NG2433361H; NG2433370H; NG2433389H; NG2433396H; NG2433398H; NG2433415H; NG2433420H; NG2433425H; NG2433429H; NG2433438H; NG2433441H; NG2433443H; NG2433460H; NG2433463H; NG2433469H; NG2433471H; NG2433473H; NG2433481H; NG2433489H; NG2433496H; NG2433500H; NG2433564H; NG2433590H; NG2433593H; NG2433603H; NG2433608H; NG2433613H; NG2433618H; NG2433622H; NG2433633H; NG2433665H; NG2433667H; NG2433668H; NG2433687H; NG2433692H; NG2433698H; NG2433755H; NG2433756H; NG2433816H; NG2433820H; NG2433823H; NG2433824H; NG2433902H; NG2433910H; NG2433917H; NG2433923H; NG2433927H; NG2433931H; NG2433933H; NG2433937H; NG2433942H; NG2433943H; NG2433947H; NG2433951H; NG2433958H; NG2433965H; NG2433986H; NG2434011H; NG2434016H; NG2434022H; NG2434028H; NG2434030H; NG2434033H; NG2434036H; NG2434054H; NG2434064H; NG2434065H; NG2434074H; NG2434079H; NG2434084H; NG2434097H; NG2434130H; NG2434142H; NG2434154H; NG2434155H; NG2434158H; NG2434210H; NG2434213H; NG2434215H; NG2434217H; NG2434279H; NG2434284H; NG2434285H; NG2434288H; NG2434289H; NG2434290H; NG2434291H; NG2434292H; NG2434293H; NG2434296H; NG2434302H; NG2434307H; NG2434308H; NG2434310H; NG2434311H; NG2434313H; NG2434320H; NG2434334H; NG2434415H; NG2434446H; NG2434453H; NG2434459H; NG2434465H; NG2434472H; NG2434486H; NG2434492H; NG2434494H; NG2434495H; NG2434496H; NG2434507H; NG2434517H; NG2434519H; NG2434522H; NG2434537H; NG2434540H; NG2434546H; NG2434549H; NG2434552H; NG2434556H; NG2434560H; NG2434562H; NG2434575H; NG2434580H; NG2434677H; NG2434680H; NG2434681H; NG2434683H; NG2434687H; NG2434689H; NG2434709H; NG2434714H; NG2434715H; NG2434719H; NG2434723H; NG2434724H; NG2434730H; NG2434742H; NG2434804H; NG2434808H; NG2434809H; NG2434814H; NG2434818H; NG2434891H; NG2434911H; NG2434951H; NG2434953H; NG2434955H; NG2434961H; NG2434974H; NG2434980H; NG2435006H; NG2435028H; NG2435081H; NG2435101H; NG2435122H; NG2435129H; NG2435141H; NG2435142H; NG2435143H; NG2435147H; NG2435151H; NG2435153H; NG2435188H; NG2435229H; NG2435240H; NG2435254H; NG2435256H; NG2435257H; NG2435283H; NG2435287H; NG2435289H; NG2435310H; NG2435318H; NG2435321H; NG2435360H; NG2435361H; NG2435367H; NG2435385H; NG2435389H; NG2435394H; NG2435400H; NG2435401H; NG2435403H; NG2435405H; NG2435408H; NG2435417H; NG2435432H; NG2435433H; NG2435450H; NG2435452H; NG2435460H; NG2435510H; NG2435539H; NG2435635H; NG2435641H; NG2435642H; NG2435707H; NG2435710H; NG2435711H; NG2435714H; NG2435737H; NG2435743H; NG2435746H; NG2435763H; NG2435765H; NG2435787H; NG2435790H; NG2435797H; NG2435874H; NG2435895H; NG2435902H; NG2435919H; NG2435923H; NG2435934H; NG2435936H; NG2435938H; NG2435942H; NG2435953H; NG2435961H; NG2435962H; NG2435971H; NG2436022H; NG2436051H; NG2436053H; NG2436066H; NG2436067H; NG2436079H; NG2436092H; NG2436111H; NG2436115H; NG2436179H; NG2436186H; NG2436210H; NG2436252H; NG2436256H; NG2436258H; NG2436259H; NG2436260H; NG2436271H; NG2436292H; NG2436294H; NG2436301H; NG2436304H; NG2436306H; NG2436338H; NG2436346H; NG2436349H; NG2436362H; NG2436380H; NG2436392H; NG2436402H; NG2436405H; NG2436406H; NG2436411H; NG2436416H; NG2436424H; NG2436427H; NG2436428H; NG2436429H; NG2436442H; NG2436444H; NG2436445H; NG2436447H; NG2436476H; NG2436505H; NG2436507H; NG2436522H; NG2436527H; NG2436528H; NG2436529H; NG2436533H; NG2436534H; NG2436608H; NG2436609H; NG2436610H; NG2436613H; NG2436623H; NG2436636H; NG2436672H; NG2436673H; NG2436679H; NG2436692H; NG2436695H; NG2436702H; NG2436708H; NG2436718H; NG2436727H; NG2436728H; NG2436734H; NG2436747H; NG2436748H; NG2436759H; NG2436765H; NG2436767H; NG2436768H; NG2436773H; NG2436798H; NG2436802H; NG2436821H; NG2436851H; NG2436855H; NG2436870H; NG2436873H; NG2436896H; NG2436899H; NG2436955H; NG2436959H; NG2436960H; NG2436962H; NG2436979H; NG2436989H; NG2436993H; NG2436994H; NG2437023H; NG2437025H; NG2437036H; NG2437050H; NG2437053H; NG2437055H; NG2437058H; NG2437061H; NG2437063H; NG2437074H; NG2437084H; NG2437104H; NG2437109H; NG2437111H; NG2437118H; NG2437132H; NG2437133H; NG2437169H; NG2437181H; NG2437212H; NG2437213H; NG2437216H; NG2437219H; NG2437258H; NG2437260H; NG2437272H; NG2437281H; NG2437307H; NG2437310H; NG2437311H; NG2437315H; NG2437317H; NG2437318H; NG2437320H; NG2437322H; NG2437350H; NG2437363H; NG2437366H; NG2437375H; NG2437377H; NG2437380H; NG2437388H; NG2437426H; NG2437453H; NG2437454H; NG2437458H; NG2437511H; NG2437524H; NG2437525H; NG2437540H; NG2437545H; NG2437548H; NG2437551H; NG2437555H; NG2437556H; NG2437558H; NG2437559H; NG2437576H; NG2437581H; NG2437590H; NG2437592H; NG2437594H; NG2437601H; NG2437620H; NG2437631H; NG2437848H; NG2437852H; NG2437854H; NG2437860H; NG2437872H; NG2437875H; NG2437882H; NG2437884H; NG2437898H; NG2437907H; NG2437912H; NG2437924H; NG2437927H; NG2437938H; NG2437949H; NG2437962H; NG2437987H; NG2437988H; NG2437989H; NG2437993H; NG2437994H; NG2437996H; NG2438009H; NG2438027H; NG2438032H; NG2438035H; NG2438052H; NG2438054H; NG2438071H; NG2438082H; NG2438126H; NG2438127H; NG2438132H; NG2438134H; NG2438135H; NG2438136H; NG2438138H; NG2438143H; NG2438187H; NG2438197H; NG2438215H; NG2438217H; NG2438228H; NG2438236H; NG2438279H; NG2438284H; NG2438288H; NG2438291H; NG2438301H; NG2438305H; NG2438327H; NG2438329H; NG2438332H; NG2438333H; NG2438338H; NG2465309H; NG2465313H; NG2465318H; NG2465337H; NG2465338H; NG2465344H; NG2465348H; NG2465351H; NG2465355H; NG2465357H; NG2465359H; NG2465365H; NG2465366H; NG2465368H; NG2465413H; NG2465417H; NG2465419H; NG2465423H; NG2465426H; NG2465431H; NG2465434H; NG2465442H; NG2465446H; NG2465448H; NG2465451H; NG2465455H; NG2465458H; NG2465459H; NG2465461H; NG2465465H; NG2465472H; NG2465479H; NG2465482H; NG2465485H; NG2465490H; NG2465504H; NG2465510H; NG2465517H; NG2465519H; NG2465521H; NG2465525H; NG2465530H; NG2465544H; NG2465546H; NG2465548H; NG2465552H; NG2465554H; NG2465560H; NG2465561H; NG2465565H; NG2465569H; NG2465573H; NG2465585H; NG2465586H; NG2465596H; NG2465600H; NG2465602H; NG2465607H; NG2465635H; NG2465639H; NG2465643H; NG2465653H; NG2465655H; NG2465657H; NG2465659H; NG2465687H; NG2465690H; NG2465695H; NG2465699H; NG2465715H; NG2465717H; NG2465726H; NG2465731H; NG2465732H; NG2465736H; NG2465738H; NG2465745H; NG2465748H; NG2465778H; NG2465787H; NG2465794H; NG2465798H; NG2465806H; NG2465811H; NG2465813H; NG2465815H; NG2465816H; NG2465821H; NG2465822H; NG2465824H; NG2465830H; NG2465833H; NG2465837H; NG2465839H; NG2465843H; NG2465851H; NG2465852H; NG2465855H; NG2465857H; NG2465859H; NG2465870H; NG2465874H; NG2465893H; NG2465901H; NG2465905H; NG2465906H; NG2465907H; NG2465909H; NG2465910H; NG2465913H; NG2465919H; NG2465920H; NG2465923H; NG2465927H; NG2465928H; NG2465930H; NG2465935H; NG2465941H; NG2465943H; NG2465946H; NG2465947H; NG2465956H; NG2465963H; NG2465971H; NG2465975H; NG2465977H; NG2465982H; NG2466000H; NG2466001H; NG2466002H; NG2466040H; NG2466042H; NG2466049H; NG2466057H; NG2466060H; NG2466065H; NG2466074H; NG2466076H; NG2466077H; NG2466079H; NG2466088H; NG2466094H; NG2466119H; NG2466120H; NG2466123H; NG2466124H; NG2466136H; NG2466139H; NG2466180H; NG2466186H; NG2466192H; NG2466194H; NG2466201H; NG2466210H; NG2466229H; NG2466243H; NG2466283H; NG2466311H; NG2466317H; NG2466318H; NG2466340H; NG2466344H; NG2466350H; NG2466351H; NG2466354H; NG2466369H; NG2466377H; NG2466397H; NG2466398H; NG2466399H; NG2466403H; NG2466410H; NG2466412H; NG2466416H; NG2466419H; NG2466427H; NG2466438H; NG2466445H; NG2466447H;
NG2466453H; NG2466456H; NG2466458H; NG2466460H; NG2466471H; NG2466495H; NG2466500H; NG2466510H; NG2466512H; NG2466517H; NG2466524H; NG2466525H; NG2466527H; NG2466532H; NG2466535H; NG2466538H; NG2466550H; NG2466565H; NG2466567H; NG2466573H; NG2466577H; NG2466585H; NG2466602H; NG2466603H; NG2466609H; NG2466617H; NG2466623H; NG2466639H; NG2466645H; NG2466651H; NG2466657H; NG2466667H; NG2466668H; NG2466672H; NG2466680H; NG2466696H; NG2466706H; NG2466721H; NG2466724H; NG2466751H; NG2466753H; NG2466755H; NG2466818H; NG2466822H; NG2466825H; NG2466827H; NG2466828H; NG2466839H; NG2466840H; NG2466879H; NG2466914H; NG2466916H; NG2466918H; NG2466925H; NG2466926H; NG2466928H; NG2466930H; NG2466934H; NG2466936H; NG2466940H; NG2466946H; NG2466955H; NG2466983H; NG2466997H; NG2466999H; NG2467000H; NG2467004H; NG2467011H; NG2467015H; NG2467020H; NG2467025H; NG2467102H; NG2467109H; NG2467124H; NG2467128H; NG2467147H; NG2467195H; NG2467198H; NG2467200H; NG2467207H; NG2467210H; NG2467214H; NG2467215H; NG2467225H; NG2474718H; NG2474719H; NG2474724H; NG2474726H; NG2474727H; NG2474730H; NG2474739H; NG2474740H; NG2474742H; NG2474743H; NG2474760H; NG2474774H; NG2474775H; NG2474792H; NG2474798H; NG2474807H; NG2474809H; NG2474820H; NG2474826H; NG2474833H; NG2474836H; NG2474838H; NG2474839H; NG2474860H; NG2474866H; NG2474867H; NG2474874H; NG2474880H; NG2474886H; NG2474890H; NG2474892H; NG2474893H; NG2474896H; NG2474924H; NG2474925H; NG2474929H; NG2474934H; NG2474943H; NG2474948H; NG2474950H; NG2474956H; NG2474958H; NG2474962H; NG2474967H; NG2474970H; NG2474973H; NG2474979H; NG2474981H; NG2474982H; NG2474987H; NG2474990H; NG2474993H; NG2474996H; NG2474999H; NG2475022H; NG2475032H; NG2475050H; NG2475098H; NG2475100H; NG2475101H; NG2475107H; NG2475109H; NG2475111H; NG2475113H; NG2475124H; NG2475127H; NG2475138H; NG2475146H; NG2475158H; NG2475164H; NG2475168H; NG2475170H; NG2475173H; NG2475176H; NG2475177H; NG2475189H; NG2475190H; NG2475192H; NG2475193H; NG2475204H; NG2475208H; NG2475222H; NG2475224H; NG2475227H; NG2475228H; NG2475229H; NG2475232H; NG2475234H; NG2475236H; NG2475273H; NG2475275H; NG2475290H; NG2475306H; NG2475307H; NG2475311H; NG2475313H; NG2475315H; NG2475329H; NG2475337H; NG2475341H; NG2475350H; NG2475352H; NG2475361H; NG2475365H; NG2475367H; NG2475368H; NG2475369H; NG2475371H; NG2475375H; NG2475479H; NG2475494H; NG2475501H; NG2475506H; NG2475524H; NG2475526H; NG2475528H; NG2475530H; NG2475532H; NG2475542H; NG2475550H; NG2475568H; NG2475570H; NG2475601H; NG2475606H; NG2475614H; NG2475650H; NG2475653H; NG2475655H; NG2475725H; NG2475738H; NG2475740H; NG2475744H; NG2475779H; NG2475788H; NG2475790H; NG2475814H; NG2475825H; NG2475826H; NG2475831H; NG2475838H; NG2475845H; NG2475850H; NG2475852H; NG2475855H; NG2475871H; NG2475874H; NG2475875H; NG2475890H; NG2475896H; NG2475909H; NG2475918H; NG2475920H; NG2475921H; NG2475925H; NG2475933H; NG2475940H; NG2475946H; NG2475951H; NG2475953H; NG2475954H; NG2475957H; NG2475973H; NG2475976H; NG2475978H; NG2475990H; NG2475996H; NG2475999H; NG2476000H; NG2476001H; NG2476010H; NG2476011H; NG2476022H; NG2476023H; NG2476029H; NG2476033H; NG2476036H; NG2476037H; NG2476040H; NG2476058H; NG2476059H; NG2476083H; NG2476091H; NG2476098H; NG2476099H; NG2476102H; NG2476103H; NG2476104H; NG2476108H; NG2476118H; NG2476119H; NG2476120H; NG2476121H; NG2476122H; NG2476124H; NG2476132H; NG2476138H; NG2476140H; NG2476156H; NG2476157H; NG2476160H; NG2476162H; NG2476172H; NG2476177H; NG2476186H; NG2476187H; NG2476232H; NG2476247H; NG2476263H; NG2476266H; NG2476268H; NG2476304H; NG2476305H; NG2476307H; NG2476309H; NG2476319H; NG2476320H; NG2476339H; NG2476343H; NG2476344H; NG2476345H; NG2476346H; NG2476347H; NG2476350H; NG2476356H; NG2476357H; NG2476366H; NG2476375H; NG2476382H; NG2476383H; NG2476390H; NG2476393H; NG2476396H; NG2476397H; NG2476399H; NG2476408H; NG2476409H; NG2476413H; NG2476417H; NG2476419H; NG2476420H; NG2476421H; NG2476423H; NG2476424H; NG2476427H; NG2476428H; NG2476429H; NG2476430H; NG2476435H; NG2476436H; NG2476438H; NG2476439H; NG2476440H; NG2476442H; NG2476444H; NG2476446H; NG2476451H; NG2476453H; NG2476456H; NG2476474H; NG2476476H; NG2476477H; NG2476478H; NG2476490H; NG2476498H; NG2476500H; NG2476504H; NG2476522H; NG2476526H; NG2476529H; NG2476536H; NG2476542H; NG2476544H; NG2476545H; NG2476546H; NG2476550H; NG2476559H; NG2476561H; NG2476563H; NG2476565H; NG2476571H; NG2476575H; NG2476588H; NG2476589H; NG2476591H; NG2476609H; NG2482054H; NG2482063H; NG2482064H; NG2482067H; NG2482083H; NG2482089H; NG2482101H; NG2482106H; NG2482116H; NG2482117H; NG2482122H; NG2482125H; NG2482146H; NG2482147H; NG2482157H; NG2482199H; NG2482200H; NG2482209H; NG2482214H; NG2482215H; NG2482217H; NG2482221H; NG2482222H; NG2482224H; NG2482226H; NG2482227H; NG2482228H; NG2482239H; NG2482243H; NG2482244H; NG2482247H; NG2482249H; NG2482258H; NG2482263H; NG2482267H; NG2482268H; NG2482272H; NG2482275H; NG2482277H; NG2482283H; NG2482284H; NG2482290H; NG2482331H; NG2482333H; NG2482356H; NG2482357H; NG2482375H; NG2482376H; NG2482385H; NG2482386H; NG2482392H; NG2482398H; NG2482399H; NG2482403H; NG2482404H; NG2482406H; NG2482408H; NG2482410H; NG2482412H; NG2482416H; NG2482419H; NG2482423H; NG2482426H; NG2482430H; NG2482435H; NG2482472H; NG2482482H; NG2482485H; NG2482486H; NG2482487H; NG2482489H; NG2482493H; NG2482494H; NG2482497H; NG2482498H; NG2482501H; NG2482503H; NG2482507H; NG2482515H; NG2482520H; NG2482521H; NG2482525H; NG2482526H; NG2482527H; NG2482530H; NG2482531H; NG2482537H; NG2482538H; NG2482540H; NG2482548H; NG2482554H; NG2482562H; NG2482564H; NG2482566H; NG2482573H; NG2482574H; NG2482592H; NG2482594H; NG2482596H; NG2482599H; NG2482605H; NG2482619H; NG2482620H; NG2482622H; NG2482909H; NG2482913H; NG2482914H; NG2482916H; NG2482921H; NG2482922H; NG2482925H; NG2482926H; NG2482936H; NG2482939H; NG2482941H; NG2482943H; NG2482947H; NG2482951H; NG2482952H; NG2482955H; NG2482956H; NG2482959H; NG2482964H; NG2482965H; NG2482988H; NG2482989H; NG2482991H; NG2483003H; NG2483006H; NG2483009H; NG2483010H; NG2483013H; NG2483016H; NG2483017H; NG2483018H; NG2483022H; NG2483029H; NG2483030H; NG2483031H; NG2483034H; NG2483035H; NG2483037H; NG2483038H; NG2483043H; NG2483044H; NG2483049H; NG2483050H; NG2483053H; NG2483055H; NG2483058H; NG2483060H; NG2483062H; NG2483063H; NG2483067H; NG2483068H; NG2483069H; NG2483074H; NG2483076H; NG2483079H; NG2483080H; NG2483081H; NG2483085H; NG2483086H; NG2483087H; NG2483096H; NG2483101H; NG2483113H; NG2483114H; NG2483118H; NG2483123H; NG2483127H; NG2483130H; NG2483134H; NG2483138H; NG2483140H; NG2483142H; NG2483144H; NG2483145H; NG2483152H; NG2483153H; NG2483154H; NG2483156H; NG2483160H; NG2483169H; NG2483174H; NG2483177H; NG2483179H; NG2483181H; NG2483184H; NG2483189H; NG2483190H; NG2483191H; NG2483197H; NG2483200H; NG2483203H; NG2483206H; NG2483207H; NG2483213H; NG2483215H; NG2483218H; NG2483221H; NG2483228H; NG2483229H; NG2483230H; NG2483233H; NG2483236H; NG2483242H; NG2483246H; NG2483248H; NG2483250H; NG2483253H; NG2483255H; NG2483260H; NG2483299H; NG2483300H; NG2483301H; NG2483315H; NG2483320H; NG2483331H; NG2483333H; NG2483335H; NG2483337H; NG2483341H; NG2483353H; NG2483354H; NG2483355H; NG2483361H; NG2483362H; NG2483366H; NG2483381H; NG2483408H; NG2483428H; NG2483443H; NG2483446H; NG2483492H; NG2483496H; NG2483498H; NG2483502H; NG2483507H; NG2483512H; NG2483563H; NG2483596H; NG2483604H; NG2483626H; NG2483627H; NG2483628H; NG2483634H; NG2483636H; NG2483654H; NG2483657H; NG2483669H; NG2483671H; NG2483684H; NG2483705H; NG2483711H; NG2483719H; NG2483728H; NG2483737H; NG2483739H; NG2483741H; NG2483743H; NG2483748H; NG2483752H; NG2483779H; NG2483780H; NG2483784H; NG2483788H; NG2483790H; NG2483800H; NG2483806H; NG2483818H; NG2483919H; NG2483931H; NG2483951H; NG2483971H; NG2483973H; NG2483981H; NG2483994H; NG2483995H; NG2483996H; NG2483997H; NG2483998H; NG2484000H; NG2484001H; NG2484004H; NG2484005H; NG2484007H; NG2484010H; NG2484030H; NG2484204H; NG2484227H; NG2484244H; NG2484246H; NG2484276H; NG2484278H; NG2484316H; NG2484323H; NG2484415H; NG2484419H; NG2484446H; NG2484449H; NG2484452H; NG2484497H; NG2484504H; NG2484524H; NG2484525H; NG2484530H; NG2484557H; NG2484563H; NG2484579H; NG2484658H; NG2484664H; NG2484682H; NG2484684H; NG2484687H; NG2484688H; NG2484691H; NG2484694H; NG2484697H; NG2484699H; NG2484701H; NG2484707H; NG2484732H; NG2484733H; NG2484734H; NG2484736H; NG2484738H; NG2484741H; NG2484742H; NG2484743H; NG2484744H; NG2484757H; NG2484760H; NG2484761H; NG2484763H; NG2484766H; NG2484776H; NG2484777H; NG2484778H; NG2484780H; NG2484782H; NG2484785H; NG2484819H; NG2484823H; NG2484826H; NG2484830H; NG2484832H; NG2484838H; NG2484839H; NG2484841H; NG2484844H; NG2484874H; NG2484906H; NG2484924H; NG2484926H; NG2484939H; NG2484942H; NG2484944H; NG2484947H; NG2484949H; NG2484953H; NG2484955H; NG2484962H; NG2484965H; NG2484966H; NG2484969H; NG2484970H; NG2484971H; NG2484975H; NG2484976H; NG2484978H; NG2484986H; NG2484987H; NG2484999H; NG2485001H; NG2485005H; NG2485014H; NG2485016H; NG2485035H; NG2485044H; NG2485049H; NG2485053H; NG2485054H; NG2485059H; NG2485078H; NG2485082H; NG2485086H; NG2485088H; NG2485090H; NG2485094H; NG2485095H; NG2485106H; NG2485115H; NG2485118H; NG2485120H; NG2485125H; NG2485127H; NG2485129H; NG2485149H; NG2485159H; NG2485163H; NG2485165H; NG2485171H; NG2485246H; NG2485353H; NG2485357H; NG2485383H; NG2485517H; NG2485600H; NG2485614H; NG2485618H; NG2485792H; NG2485996H; NG2486026H; NG2515478H; NG2515493H; NG2515495H; NG2515497H; NG2515501H; NG2515503H; NG2515504H; NG2515505H; NG2515514H; NG2515519H; NG2515522H; NG2515523H; NG2515526H; NG2515531H; NG2515539H; NG2515554H; NG2515562H; NG2515569H; NG2515571H; NG2515582H; NG2515594H; NG2515597H; NG2515606H; NG2515609H; NG2515617H; NG2515618H; NG2515620H; NG2515626H; NG2515630H; NG2515631H; NG2515638H; NG2515646H; NG2515651H; NG2515683H; NG2515698H; NG2516934H; NG2516957H; NG2516971H; NG2516972H; NG2516991H; NG2516992H; NG2517012H; NG2517045H; NG2517048H; NG2517055H; NG2517070H; NG2517086H; NG2517099H; NG2517103H; NG2517104H; NG2517115H; NG2517119H; NG2517121H; NG2517122H; NG2517123H; NG2517125H; NG2517128H; NG2517139H; NG2517144H; NG2517145H; NG2517147H; NG2517148H; NG2517149H; NG2517153H; NG2517157H; NG2517162H; NG2517164H; NG2517176H; NG2517192H; NG2517201H; NG2517202H; NG2517205H; NG2517209H; NG2517210H; NG2517216H; NG2517217H; NG2517224H; NG2517228H; NG2517230H; NG2517236H; NG2517241H; NG2517245H; NG2517246H; NG2517250H; NG2517257H; NG2517260H; NG2517267H; NG2517268H; NG2517275H; NG2517278H; NG2517292H; NG2517295H; NG2517296H; NG2517297H; NG2517301H; NG2517302H; NG2517305H; NG2517307H; NG2517308H; NG2517330H; NG2517341H; NG2517343H; NG2517344H; NG2517354H; NG2517355H; NG2517357H; NG2517364H; NG2517366H; NG2517367H; NG2517377H; NG2517378H; NG2517379H; NG2517380H; NG2517382H; NG2517383H; NG2517384H; NG2517385H; NG2517386H; NG2517387H; NG2517388H; NG2517395H; NG2517396H; NG2517397H; NG2517399H; NG2517400H; NG2517409H; NG2517410H; NG2517411H; NG2517414H; NG2517415H; NG2517416H; NG2517418H; NG2517420H; NG2517422H; NG2517424H; NG2517425H; NG2517426H; NG2517428H; NG2517429H; NG2517430H; NG2517431H; NG2517433H; NG2517436H; NG2517440H; NG2517441H; NG2517442H; NG2517461H; NG2517462H; NG2517463H; NG2517464H; NG2517465H; NG2517467H; NG2517468H; NG2517469H; NG2517470H; NG2517471H; NG2517472H; NG2517473H; NG2517474H; NG2517480H; NG2517487H; NG2517490H; NG2517493H; NG2517497H; NG2517498H; NG2517500H; NG2517501H; NG2517512H; NG2517514H; NG2517519H; NG2517525H; NG2517528H; NG2517612H; NG2517613H; NG2517616H; NG2517618H; NG2517621H; NG2517624H; NG2517630H; NG2517639H; NG2517642H; NG2517643H; NG2517655H; NG2517657H; NG2517665H; NG2517669H; NG2517680H; NG2517687H; NG2517695H; NG2517698H; NG2517713H; NG2517718H; NG2517722H; NG2517723H; NG2517725H; NG2517726H; NG2517729H; NG2517731H; NG2517741H; NG2517745H; NG2517753H; NG2517754H; NG2517755H; NG2517762H; NG2517764H; NG2517784H; NG2517785H; NG2517792H; NG2517793H; NG2517794H; NG2517796H; NG2517797H; NG2517809H; NG2517812H; NG2517814H; NG2517815H; NG2517816H; NG2517817H; NG2517819H; NG2517822H; NG2517824H; NG2517825H; NG2517829H; NG2517831H; NG2517837H; NG2517840H; NG2517842H; NG2517844H; NG2517850H; NG2517851H; NG2517852H; NG2517854H; NG2517855H; NG2517856H; NG2517860H; NG2517861H; NG2517862H; NG2517864H; NG2517877H; NG2517887H; NG2517889H; NG2517893H; NG2517894H; NG2517896H; NG2517903H; NG2517905H; NG2517907H; NG2517909H; NG2517910H; NG2517912H; NG2517913H; NG2517915H; NG2517917H; NG2517918H; NG2517921H; NG2517922H; NG2517923H; NG2517924H; NG2517925H; NG2517931H; NG2517936H; NG2517939H; NG2517955H; NG2517956H; NG2517958H; NG2517961H; NG2517969H; NG2517977H; NG2517980H; NG2517981H; NG2517985H; NG2517989H; NG2517990H; NG2517994H; NG2517999H; NG2518003H; NG2518007H; NG2518009H; NG2518010H; NG2518057H; NG2518070H; NG2518073H; NG2518074H; NG2518076H; NG2518077H; NG2518078H; NG2518082H; NG2518083H; NG2518084H; NG2518085H; NG2518086H; NG2518088H; NG2518089H; NG2518090H; NG2518092H; NG2518093H; NG2518094H; NG2518095H; NG2518098H; NG2518099H; NG2518100H; NG2518101H; NG2518104H; NG2518112H; NG2518113H; NG2518115H; NG2518116H; NG2518117H; NG2518118H; NG2518119H; NG2518123H; NG2518124H; NG2518125H; NG2518131H; NG2518137H; NG2518139H; NG2518141H; NG2518144H; NG2518146H; NG2518147H; NG2518148H; NG2518151H; NG2518154H; NG2518155H; NG2518156H; NG2518157H; NG2518160H; NG2518162H; NG2518163H; NG2518164H; NG2518167H; NG2518169H; NG2518170H; NG2518171H; NG2518173H; NG2518174H; NG2518185H; NG2518190H; NG2518192H; NG2518196H; NG2518198H; NG2518199H; NG2518207H; NG2518209H; NG2518212H; NG2518225H; NG2518226H; NG2518232H; NG2518234H; NG2518237H; NG2518239H; NG2518240H; NG2518241H; NG2518242H; NG2518243H; NG2518245H; NG2518246H; NG2518247H; NG2518249H; NG2518251H; NG2518256H; NG2518289H; NG2518292H; NG2518298H; NG2518302H; NG2518305H; NG2518321H; NG2518337H; NG2518346H; NG2518359H; NG2518377H; NG2518378H; NG2518402H; NG2518409H; NG2518424H; NG2518471H; NG2518507H; NG2518519H; NG2518521H; NG2518543H; NG2518555H; NG2518560H; NG2518584H; NG2518599H; NG2518634H; NG2518644H; NG2518663H; NG2518714H; NG2518794H; NG2518921H; NG2518926H; NG2518943H; NG2519020H; NG2519022H; NG2519046H; NG2519054H; NG2519056H; NG2519077H; NG2519082H; NG2519144H; NG2519157H; NG2519164H; NG2519439H; NG1667558H; NG1708002H; NG1708324H; NG1731764H; NG1731821H; NG2359667H; NG2359681H; NG2396594H; NG2396599H; NG2396621H; NG2396674H; NG2396686H; NG2396692H; NG2396710H; NG2396713H; NG2396720H; NG2396727H; NG2396733H; NG2396739H; NG2397962H; NG2397963H; NG2397964H; NG2397975H; NG2397976H; NG2397979H; NG2397980H; NG2397982H; NG2397984H; NG2397986H; NG2397991H; NG2397998H; NG2398001H; NG2402130H; NG2402131H; NG2402135H; NG2402141H; NG2402144H; NG2402152H; NG2402154H; NG2402160H; NG2402171H; NG2402268H; NG2402296H; NG2402416H; NG2402441H; NG2402555H; NG2402562H; NG2402571H; NG2402574H; NG2402636H; NG2402682H; NG2402694H; NG2402696H; NG2402745H; NG2402747H; NG2403142H; NG2405157H; NG2405167H; NG2405172H; NG2405176H; NG2405181H; NG2405187H; NG2405192H; NG2405197H; NG2405203H; NG2405208H; NG2405978H; NG2406353H; NG2406381H; NG2406410H; NG2406834H; NG2406847H; NG2407832H; NG2407844H; NG2407857H; NG2407860H; NG2407874H; NG2407908H; NG2407913H; NG2407938H; NG2407956H; NG2407960H; NG2407966H; NG2407974H; NG2407980H; NG2407987H; NG2407991H; NG2407992H; NG2408008H; NG2408087H; NG2408095H; NG2408132H; NG2408137H; NG2408138H; NG2408141H; NG2408153H; NG2408257H; NG2408283H; NG2408308H; NG2408320H; NG2408365H; NG2408393H; NG2408408H; NG2408437H; NG2408463H; NG2408464H; NG2408489H; NG2408527H; NG2408537H; NG2408555H; NG2408564H; NG2408570H; NG2408733H; NG2408751H; NG2409852H; NG2414431H; NG2414433H; NG2414436H; NG2414447H; NG2414492H; NG2419792H; NG2419795H; NG2419796H; NG2419797H; NG2419835H; NG2419837H; NG2419838H; NG2419842H; NG2419846H; NG2419851H; NG2420235H; NG2420261H; NG2420782H; NG2420838H; NG2420878H; NG2420885H; NG2420896H; NG2420898H; NG2420917H; NG2420922H; NG2420960H; NG2420963H; NG2421008H; NG2421010H; NG2421021H; NG2421071H; NG2421081H; NG2421556H; NG2421559H; NG2421570H; NG2421800H; NG2423705H; NG2424834H; NG2425539H; NG2434722H; NG2434735H; NG2434747H; NG2434750H; NG2434764H; NG2434807H; NG2434844H; NG2434882H; NG2434886H; NG2434897H; NG2434908H; NG2434946H; NG2434968H; NG2435024H; NG2435109H; NG2435155H; NG2435252H; NG2435276H; NG2435338H; NG2435358H; NG2436343H; NG2436524H; NG2436677H; NG2436681H; NG2436688H; NG2436697H; NG2436709H; NG2436710H; NG2436721H; NG2436723H; NG2436738H; NG2436752H; NG2474837H; NG2474864H; NG2518843H; NG2358212H; NG2358221H; NG2358233H; NG2358247H; NG2358299H; NG2358330H; NG2358331H; NG2358336H; NG2358362H; NG2358373H; NG2358422H; NG2358515H; NG2359648H; NG2372118H; NG2372456H; NG2372462H; NG2372464H; NG2372571H; NG2372573H; NG2372587H; NG2372626H; NG2372646H; NG2372725H; NG2372912H; NG2372966H; NG2373275H; NG2373449H; NG2373450H; NG2373451H; NG2373459H; NG2373463H; NG2373472H; NG2374723H; NG2374728H; NG2374823H; NG2374849H; NG2374853H; NG2374854H; NG2374880H; NG2374932H; NG2374962H; NG2374971H; NG2375060H; NG2375061H; NG2375087H; NG2375117H; NG2375132H; NG2375158H; NG2375161H; NG2375432H; NG2375448H; NG2375451H; NG2375477H; NG2375484H; NG2375492H; NG2375498H; NG2375508H; NG2375657H; NG2375736H; NG2375738H; NG2375821H; NG2375837H; NG2375849H; NG2375869H; NG2375894H; NG2375904H; NG2375924H; NG2375928H; NG2375933H; NG2375937H; NG2375952H; NG2375979H; NG2376023H; NG2376044H; NG2376055H; NG2376192H; NG2376203H; NG2376294H; NG2376302H; NG2376308H; NG2376320H; NG2376324H; NG2376452H; NG2376474H; NG2376477H; NG2376494H; NG2376614H; NG2376615H; NG2376628H; NG2402174H; NG2402182H; NG2402330H; NG2402410H; NG2402447H; NG2402448H; NG2402539H; NG2402564H; NG2402565H; NG2402566H; NG2402567H; NG2402573H; NG2402700H; NG2402703H; NG2402708H; NG2402718H; NG2402726H; NG2402730H; NG2402741H; NG2402744H; NG2402754H; NG2402755H; NG2402758H; NG2402759H; NG2402763H; NG2402764H; NG2402766H; NG2402770H; NG2402772H; NG2402775H; NG2402777H; NG2402793H; NG2402795H; NG2402799H; NG2402800H; NG2402805H; NG2402806H; NG2402808H; NG2402810H; NG2402811H; NG2402820H; NG2402821H; NG2402823H; NG2402824H; NG2402825H; NG2402842H; NG2402846H; NG2402848H; NG2402849H; NG2402851H; NG2402880H; NG2402938H; NG2402969H; NG2402990H; NG2403015H; NG2403017H; NG2403025H; NG2403027H; NG2403030H; NG2403033H; NG2403038H; NG2403091H; NG2403551H; NG2403761H; NG2403770H; NG2403889H; NG2403891H; NG2403894H; NG2403900H; NG2403918H; NG2403940H; NG2404022H; NG2404369H; NG2404389H; NG2404422H; NG2404424H; NG2404427H; NG2404428H; NG2404429H; NG2404431H; NG2404433H; NG2404438H; NG2404442H; NG2404443H; NG2404460H; NG2404462H; NG2404464H; NG2404465H; NG2404466H; NG2404469H; NG2404482H; NG2404485H; NG2404490H; NG2404491H; NG2404492H; NG2404499H; NG2404509H; NG2404511H; NG2404513H; NG2404514H; NG2404516H; NG2404517H; NG2404518H; NG2404520H; NG2404521H; NG2404530H; NG2404537H; NG2404541H; NG2404543H; NG2404546H; NG2404548H; NG2404550H; NG2404553H; NG2404554H; NG2404555H; NG2404557H; NG2404559H; NG2404560H; NG2404562H; NG2404563H; NG2404566H; NG2404567H; NG2404571H; NG2404574H; NG2404575H; NG2404576H; NG2404579H; NG2404581H; NG2404582H; NG2404583H; NG2404602H; NG2404603H; NG2404612H; NG2404613H; NG2404617H; NG2404638H; NG2404647H; NG2404663H; NG2404664H; NG2404671H; NG2404679H; NG2404684H; NG2404694H; NG2404700H; NG2404701H; NG2404738H; NG2404740H; NG2404754H; NG2404755H; NG2404756H; NG2404758H; NG2404759H; NG2404768H; NG2404787H; NG2404791H; NG2404803H; NG2404806H; NG2404813H; NG2404818H; NG2404829H; NG2404834H; NG2404846H; NG2404852H; NG2404853H; NG2404858H; NG2404867H; NG2404890H; NG2404896H; NG2404901H; NG2404904H; NG2404906H; NG2404909H; NG2404911H; NG2404913H; NG2404915H; NG2404940H; NG2404941H; NG2404952H; NG2404954H; NG2404956H; NG2404968H; NG2404970H; NG2404971H; NG2404972H; NG2404979H; NG2404982H; NG2404985H; NG2404998H; NG2405021H; NG2405794H; NG2405797H; NG2405802H; NG2405804H; NG2405805H; NG2405806H; NG2405807H; NG2405809H; NG2405812H; NG2405858H; NG2405936H; NG2405939H; NG2405976H; NG2405977H; NG2405980H; NG2405986H; NG2405991H; NG2405996H; NG2406000H; NG2406027H; NG2406033H; NG2406044H; NG2406058H; NG2406060H; NG2406061H; NG2406066H; NG2406067H; NG2406072H; NG2406131H; NG2406186H; NG2406189H; NG2406223H; NG2406227H; NG2406246H; NG2406289H; NG2406299H; NG2406373H; NG2406377H; NG2406384H; NG2406386H; NG2406391H; NG2406407H; NG2406409H; NG2406416H; NG2406421H; NG2406430H; NG2406448H; NG2406457H; NG2406464H; NG2406472H; NG2406477H; NG2406490H; NG2406500H; NG2406505H; NG2406551H; NG2406680H; NG2406693H; NG2406709H; NG2406722H; NG2406723H; NG2406749H; NG2406760H; NG2406769H; NG2406787H; NG2406788H; NG2406824H; NG2406828H; NG2406830H; NG2406845H; NG2406858H; NG2406900H; NG2406915H; NG2406917H; NG2406922H; NG2406929H; NG2406938H; NG2406939H; NG2406941H; NG2406943H; NG2406948H; NG2406961H; NG2406965H; NG2406968H; NG2406981H; NG2406990H; NG2406993H; NG2406999H; NG2407001H; NG2407017H; NG2407032H; NG2407063H; NG2407089H; NG2407093H; NG2407095H; NG2407100H; NG2407104H; NG2407108H; NG2407136H; NG2407138H; NG2407144H; NG2407157H; NG2407159H; NG2407166H; NG2407168H; NG2407171H; NG2407179H; NG2407181H; NG2407203H; NG2407205H; NG2407208H; NG2407224H; NG2407255H; NG2407260H; NG2407265H; NG2407295H; NG2407308H; NG2407310H; NG2407316H; NG2407319H; NG2407354H; NG2407413H; NG2407453H; NG2407458H; NG2407463H; NG2407465H; NG2407482H; NG2407485H; NG2407495H; NG2407497H; NG2407499H; NG2407504H; NG2407511H; NG2407513H; NG2407519H; NG2407522H; NG2407535H; NG2407586H; NG2407600H; NG2407608H; NG2407638H; NG2407656H; NG2407673H; NG2407696H; NG2407699H; NG2407700H; NG2407710H; NG2407714H; NG2407728H; NG2407732H; NG2407733H; NG2407912H; NG2408274H; NG2408288H; NG2408349H; NG2408369H; NG2408374H; NG2408417H; NG2408434H; NG2408493H; NG2408498H; NG2408505H; NG2408521H; NG2408525H; NG2408553H; NG2408582H; NG2410258H; NG2410344H; NG2410616H; NG2413385H; NG2413389H; NG2417497H; NG2417502H; NG2417593H; NG2417599H; NG2417700H; NG2417701H; NG2417706H; NG2417712H; NG2417787H; NG2417789H; NG2417795H; NG2417800H; NG2417813H; NG2418018H; NG2418043H; NG2418178H; NG2418186H; NG2418403H; NG2418404H; NG2418405H; NG2418411H; NG2418414H; NG2418417H; NG2418419H; NG2418420H; NG2418421H; NG2418439H; NG2418441H; NG2418444H; NG2418448H; NG2418554H; NG2418557H; NG2418560H; NG2418581H; NG2418583H; NG2418737H; NG2418746H; NG2418749H; NG2418756H; NG2418758H; NG2418761H; NG2418763H; NG2419055H; NG2419059H; NG2419060H; NG2419798H; NG2419799H; NG2419801H; NG2419802H; NG2419803H; NG2419804H; NG2419855H; NG2419856H; NG2419926H; NG2419928H; NG2419929H; NG2419932H; NG2419942H; NG2420727H; NG2420742H; NG2423600H; NG2423643H; NG2423683H; NG2423711H; NG2423730H; NG2423739H; NG2423945H; NG2423975H; NG2423986H; NG2424603H; NG2425092H; NG2429026H; NG2432347H; NG2433349H; NG2433366H; NG2433377H; NG2433403H; NG2433409H; NG2433411H; NG2433419H; NG2433431H; NG2433439H; NG2433502H; NG2433567H; NG2433570H; NG2433586H; NG2433595H; NG2433602H; NG2433604H; NG2433606H; NG2433610H; NG2433616H; NG2433636H; NG2433701H; NG2433749H; NG2433751H; NG2433813H; NG2433896H; NG2433906H; NG2433934H; NG2433953H; NG2433956H; NG2433969H; NG2433974H; NG2433979H; NG2434051H; NG2434171H; NG2434273H; NG2434295H; NG2434300H; NG2434314H; NG2434463H; NG2434692H; NG2436270H; NG2436273H; NG2436289H; NG2436291H; NG2436296H; NG2436335H; NG2436509H; NG2436555H; NG2436556H; NG2436558H; NG2436560H; NG2436604H; NG2436611H; NG2436612H; NG2436617H; NG2436619H; NG2436622H; NG2436624H; NG2436641H; NG2436669H; NG2436675H; NG2436676H; NG2436770H; NG2436771H; NG2437354H; NG2437357H; NG2437359H; NG2437362H; NG2437372H; NG2437382H; NG2437385H; NG2437389H; NG2437390H; NG2437419H; NG2437448H; NG2437452H; NG2437455H; NG2437460H; NG2437466H; NG2437470H; NG2437473H; NG2437475H; NG2437496H; NG2437509H; NG2437513H; NG2437515H; NG2437518H; NG2437523H; NG2437534H; NG2437536H; NG2437538H; NG2437541H; NG2437542H; NG2437547H; NG2437552H; NG2437586H; NG2437608H; NG2437611H; NG2437617H; NG2437639H; NG2437643H; NG2437650H; NG2437659H; NG2437662H; NG2437838H; NG2437846H; NG2437857H; NG2437862H; NG2437867H; NG2437868H; NG2437869H; NG2437870H; NG2437874H; NG2437876H; NG2437892H; NG2437895H; NG2437903H; NG2437919H; NG2437920H; NG2465758H; NG2465760H; NG2465765H; NG2467206H; NG2475504H; NG2476071H; NG2476126H; NG2476149H; NG2476491H; NG2476497H; NG2476537H; NG2476549H; NG2476602H; NG2483462H; NG2483463H; NG2483802H; NG2483809H; NG2483821H; NG2483824H; NG2483891H; NG2483901H; NG2483905H; NG2483920H; NG2483921H; NG2483923H; NG2483925H; NG2483927H; NG2483933H; NG2483934H; NG2483936H; NG2483950H; NG2483953H; NG2483960H; NG2483963H; NG2483966H; NG2484008H; NG2484009H; NG2484011H; NG2484022H; NG2484032H; NG2484035H; NG2484036H; NG2484038H; NG2484040H; NG2484047H; NG2484052H; NG2484054H; NG2484381H; NG2484416H; NG2484417H; NG2484421H; NG2484423H; NG2484429H; NG2484430H; NG2484432H; NG2484442H; NG2484447H; NG2515637H; NG2358295H; NG2358315H; NG2359715H; NG2404345H; NG2404356H; NG2405321H; NG2405575H; NG2406422H; NG2407165H; NG2407886H; NG2407975H; NG2422423H; NG2422435H; NG2423545H; NG2424210H; NG2424457H; NG2428900H; NG2358329H; NG2377686H; NG2404052H; NG2407046H; NG2407550H; NG2418559H; NG2420234H; NG2421828H; NG2423008H; NG2424890H; NG2428474H; NG2429566H; NG2431124H; NG2432886H; NG2434335H; NG2435920H; NG2437369H; NG2437491H; NG2438000H; NG2372602H; NG2373468H; NG2375748H; NG2375925H; NG2376444H; NG2420612H; NG2433022H; NG2467199H; NG2467217H; NG2483895H; NG2484042H; NG2484071H; NG2386306H; NG2414082H; NG2433217H; NG2433334H; NG2433991H; NG2434018H; NG2435448H; NG2436549H; NG2436552H; NG2436554H; NG2483306H; NG2483347H; NG2483455H; NG2466533H; NG2466737H; NG2466830H; NG2466912H; NG2466938H; NG2377748H; NG2404615H; NG2409576H; NG2409645H; NG2410627H; NG2432385H; NG2432442H; NG2432513H; NG2433319H; NG2437081H; NG2465605H; NG2465972H; NG2474773H; NG2518062H; NG2413646H; NG2421400H; NG2422895H; NG2420686H; NG2420275H; NG2420196H; NG2420201H; NG2420216H; NG2420218H; NG2423526H; NG2423139H; NG2420179H; NG2422881H; NG2420368H; NG2420424H; NG2421112H; NG2420273H; NG2420329H; NG2420254H; NG2420263H; NG2420354H; NG2420437H; NG2421241H; NG2421230H; NG2421326H; NG2420325H; NG2420425H; NG2420387H; NG2423438H; NG2418989H; NG2420250H; NG2420493H; NG2423577H; NG2421445H; NG2420426H; NG2423512H; NG2421403H; NG2421314H; NG2420249H; NG2420252H; NG2423688H; NG2421265H; NG2420504H; NG2421178H; NG2420911H; NG2421632H; NG2420389H; NG2421318H; NG2421358H; NG2420386H; NG2420187H; NG2423064H; NG2421132H; NG2420688H; NG2421390H; NG2422949H; NG2422197H; NG2422387H; NG2422414H; NG2422425H; NG2422432H; NG2422550H; NG2422667H; NG2423200H; NG2420236H; NG2423094H; NG2423635H; NG2421116H; NG2421372H; NG2421187H; NG2420244H; NG2422889H; NG2423419H; NG2421384H; NG2421263H; NG2423018H; NG2420114H; NG2421240H; NG2420490H; NG2423750H; |
Recalling Firm/ Manufacturer |
Medtronic Minimed 18000 Devonshire St Northridge CA 91325-1219
|
For Additional Information Contact |
Pamela Reese 818-576-3398
|
Manufacturer Reason for Recall |
Due to a software design issue, under certain conditions, a software fault is detected when a large bolus delivery at quick bolus speed completes. if the user
is not aware of the amount of active insulin and
delivers an additional bolus, there is a risk of insulin
over delivery.
|
FDA Determined Cause 2 |
Software design |
Action |
On 03/15/2021, the Recalling Firm sent an "URGENT MEDICAL DEVICE CORRECTION" Notification via regionally approved methods (e.g.
email, registered mail, courier, hand delivery) informing customers that their insulin pump with software version 6.5 that could present pump errors after delivering a large bolus under certain conditions. These errors may occur if All the following conditions are met:
1-The bolus delivery speed is programmed to Quick in the pump settings (default is Standard).
2-The SmartGuard" feature is in use.
3-The pump needs to be on the bolus delivery screen when an auto correction bolus is triggered. Auto corrections are triggered when sensor glucose (SG) is running high and Active Insulin is low.
4-The bolus amount programmed to be delivered is greater than 17.1U.
Note: This can be a single bolus greater than 17.1U or a combination of boluses totaling greater than 17.1U.
If all the above conditions are met, within 2 minutes of bolus delivery completion, the pump initiates Pump error 53, followed by Pump error 23 alarm.
Upon clearing the pump errors, the pump resets and indicates Active Insulin has been cleared. The pump then guides the user to resume operation in Manual Mode. The SmartGuard" status screen indicates the warm-up period has started. After approximately 5 hours, the SmartGuard" feature will be available.
Since Active Insulin will display 0.0 units in the pump after experiencing the pump errors above, if the user is not aware of the amount of active insulin and delivers an additional bolus, there is a risk of insulin over delivery, which may result in low blood sugar (hypoglycemia) or severe hypoglycemia. In rare cases, severe hypoglycemia, if left untreated, may lead to a life-threatening situation. As of January 21, 2021, Medtronic has received no reports of serious patient harm or serious injury related to this issue.
Customers are instructed to:
If their pump screen indicates that Active Insulin has cleare |
Quantity in Commerce |
O.U.S. Distibution only = 15,682 devices |
Distribution |
U.S.(Clinical): AR, CA, CO, CT, FL, GA, ID, MI, MN, TN, TX, and WA
O.U.S.:
Austria, Bahrain, Belgium, Canary Islands, Chile, Croatia, Czech Republic, Denmark, Egypt, Finland, France, Germany, Gibraltar, Greece, Hungary, Iceland, Ireland, Israel, Italy, Liechtenstein, Luxembourg, Malta, Martinique, Netherlands, New Caledonia, Norway, Poland, Qatar, Reunion, Romania, Slovenia, South Africa, Spain, Sweden, Switzerland, Turkey, and United Kingdom |
Total Product Life Cycle |
TPLC Device Report
|
|
1 A record in this database is created when a firm initiates a correction or removal action. The record is updated if the FDA identifies a violation and classifies the action as a recall, and it is updated for a final time when the recall is terminated. Learn more about medical device recalls.
2 Per FDA policy, recall cause determinations are subject to modification up to the point of termination of the recall.
3 The manufacturer has initiated the recall and not all products have been corrected or removed. This record will be updated as the status changes.
|
PMA Database |
PMAs with Product Code = OZP and Original Applicant = MEDTRONIC MINIMED, INC.
|
|
|
|