| Date Initiated by Firm | August 15, 2019 |
| Create Date | September 12, 2019 |
| Recall Status1 |
Terminated 3 on April 16, 2021 |
| Recall Number | Z-2520-2019 |
| Recall Event ID |
83594 |
| 510(K)Number | K132873 |
| Product Classification |
Prosthesis, knee, patellofemorotibial, semi-constrained, cemented, polymer/metal/polymer - Product Code JWH
|
| Product | XP-XP Tibial Tray - Interlok 75 mm
Item # 195757 |
| Code Information |
Lot Number 664400 664380 677580 562210 758380 650470 677760 677590 677750 758410 664390 664410 677570 613450 972810 972820 998120 158870 677770 677780 998110 283010 273090 273100 677740 703240 592490 592490R 592530 592620 703080 592660 703160 703160R 558590 592640 592650 592640R 558580 703090 703120 282950 505130 505140 703100 703190 703230 703260 703200 158890 283020 558570 592510 592520 592630 677720 703070 703170 703210 791010 592520R 322550 322530 592500 885120 975630 505160 864740 958470 855430 592540 703150 828740 505150 703060 703130 703140 703060R 840750 103060 131250 159330 131250R 011490 061450 093420 181470 703180 023400 116070 201970 036310 336740 241480 223190 261110 297090 371620 371640 384280 418750 432410 634300 599880 556600 664220 467240 511490 715900 715910 587370 684980 716120 920620 882120 906770 029290 906760 986000 072990 986030 396430 126060 163040 163060 247400 247390 705700 126050 293160 318590 293170 374530 336750 336760 374540 390140 442010 390170 442000 318580 478980 479000 479010 509860 509840 576200 543410 576210 625670 639710 625690 543400 450460 741570 780260 758570 780280 522710 559050 221440 670630 741580 708770 593650 481900 833240 873590 183550 808360 873580 850980 850990 808390 708780 076750 999390 560380 570300 570310 111730 076730 917660 951010 076740 943570 018190 137530 999380 191190 219870 289250 |
| FEI Number |
1825034
|
Recalling Firm/ Manufacturer |
Zimmer Biomet, Inc.
56 E Bell Dr
Warsaw
IN
46582-6989
|
| For Additional Information Contact | 411 Technical Services 574-371-3071 |
Manufacturer Reason for Recall | The locking bar not fully engaging |
FDA Determined Cause 2 | Manufacturing material removal |
| Action | Risk Manager Responsibilities:
1.Review this notification and ensure that affected personnel are aware of the contents.
2.If you have affected product at your facility, assist your Zimmer Biomet sales representative and quarantine all affected product. Your Zimmer Biomet sales representative will remove the affected product from your facility.
3.Complete Attachment 1 Certificate of Acknowledgement and send to CorporateQuality.PostMarket@zimmerbiomet.com. This form will be returned even if you do not have affected products at your facility.
4.Retain a copy of the acknowledgement form with your recall records in the event of a compliance audit of your facilitys documentation.
5.If you have further questions or concerns after reviewing this notice, please call customer service at 574-371-3071 between 8:00 am and 5:00pm EST, Monday through Friday. Calls received outside of call center operating hours will receive a voicemail prompt or be transferred to an on-call representative in the event of an emergency. Alternatively, your questions may be emailed to CorporateQuality.PostMarket@zimmerbiomet.com.
Surgeon Responsibilities:
1.Review this notification for awareness of the contents.
2.There are no specific patient monitoring instructions related to this recall that are recommended beyond your existing follow-up schedule.
3.A visual and audible confirmation should be made to ensure complete locking bar insertion.
4.Complete Attachment 1 Certificate of Acknowledgement and send to CorporateQuality.PostMarket@zimmerbiomet.com.
5.Retain a copy of the acknowledgement form with your recall records in the event of a compliance audit of your facilitys documentation.
6.If you have further questions or concerns after reviewing this notice, please call customer service at 574-371-3071 between 8:00 am and 5:00pm EST, Monday through Friday. Calls received outside of call center operating hours will receive a voicemail prompt or be transferred to an on- |
| Quantity in Commerce | 973 units |
| Distribution | State
NY
IN
OH
MI
GA
SC
FL
MO
WI
MN
ND
SD
NE
NJ
PA
MD
IL
IA
CA
VA
NC
DC
WV
AR
AL
MS
AL
MI
WA
OR
ID
LA
FL
KS
TN
MA
KY
OK
TX
TX
CT
AZ
NV
NM
MT
WY
CO
UT
DC
WY
Country:
KOREA
CHINA
CANADA
AUSTRALIA
JAPAN
EMEA
SWEDEN
ITALY |
| Total Product Life Cycle | TPLC Device Report |
|
1 A record in this database is created when a firm initiates a correction or removal action. The record is updated if the FDA identifies a violation and classifies the action as a recall, and it is updated for a final time when the recall is terminated. Learn more about medical device recalls. 2 Per FDA policy, recall cause determinations are subject to modification up to the point of termination of the recall. 3 For details about termination of a recall see Code of Federal Regulations (CFR) Title 21 �7.55.
|
| 510(K) Database | 510(K)s with Product Code = JWH
|