• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

TPLC - Total Product Life Cycle

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

New Search show TPLC since Back to Search Results
Device graft, vascular, synthetic/biologic composite
Product CodeMAL
Regulation Number 870.3450
Device Class 2

MDR Year MDR Reports MDR Events
2016 20 20
2017 28 28
2018 15 15
2019 28 28
2020 24 24
2021 34 34
2022 21 21
2023 17 17
2024 8 8

Device Problems MDRs with this Device Problem Events in those MDRs
Manufacturing, Packaging or Shipping Problem 22 22
Adverse Event Without Identified Device or Use Problem 22 22
Product Quality Problem 20 20
Material Frayed 15 15
Material Puncture/Hole 15 15
Nonstandard Device 15 15
Leak/Splash 11 11
Off-Label Use 10 10
Material Integrity Problem 9 9
Device Contaminated During Manufacture or Shipping 7 7
Device Damaged Prior to Use 7 7
Device Operates Differently Than Expected 5 5
Fluid/Blood Leak 5 5
Hole In Material 5 5
Shipping Damage or Problem 5 5
Stretched 4 4
Inaccurate Information 4 4
Flaked 4 4
Unraveled Material 3 3
Use of Device Problem 3 3
Material Twisted/Bent 3 3
Insufficient Information 2 2
Appropriate Term/Code Not Available 2 2
Incomplete or Missing Packaging 2 2
Improper or Incorrect Procedure or Method 2 2
Device Contaminated at the User Facility 2 2
Patient Device Interaction Problem 2 2
Material Perforation 2 2
No Apparent Adverse Event 2 2
Physical Property Issue 1 1
Peeled/Delaminated 1 1
Material Disintegration 1 1
Therapeutic or Diagnostic Output Failure 1 1
Device Operational Issue 1 1
Material Deformation 1 1
Material Rupture 1 1
Device Issue 1 1
Contamination /Decontamination Problem 1 1
Device Contamination with Chemical or Other Material 1 1

Patient Problems MDRs with this Patient Problem Events in those MDRs
No Clinical Signs, Symptoms or Conditions 41 41
Hemorrhage/Bleeding 29 29
Blood Loss 28 28
No Consequences Or Impact To Patient 18 18
No Patient Involvement 16 16
No Known Impact Or Consequence To Patient 15 15
No Information 8 8
Insufficient Information 7 7
Fungal Infection 5 5
Pseudoaneurysm 5 5
No Code Available 4 4
Aneurysm 4 4
Bacterial Infection 4 4
Death 3 3
Failure of Implant 2 2
Not Applicable 2 2
Ventricular Fibrillation 2 2
Stenosis 2 2
Paraplegia 2 2
Unspecified Infection 1 1
High Blood Pressure/ Hypertension 1 1
Appropriate Clinical Signs, Symptoms, Conditions Term / Code Not Available 1 1
Ischemia 1 1
Exsanguination 1 1
Hemolytic Anemia 1 1
Irritation 1 1
Chest Pain 1 1
Pain 1 1
Renal Failure 1 1
Cancer 1 1

Recalls
Manufacturer Recall Class Date Posted
1 GETINGE US SALES LLC II Sep-24-2019
2 Maquet Cardiovascular, LLC II Mar-07-2022
3 Maquet Cardiovascular, LLC II Dec-20-2021
4 Maquet Cardiovascular, LLC II May-04-2020
-
-