• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

Premarket Approval (PMA)

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 


New Search Back to Search Results
Note: this medical device has supplements. The device description/function or indication may have changed. Be sure to look at the supplements to get an up-to-date information on device changes. The labeling included below is the version at time of approval of the original PMA or panel track supplement and may not represent the most recent labeling.
 
DeviceFoundationOne Liquid CDx (F1 Liquid CDx)
Generic NameNext generation sequencing oncology panel, somatic or germline variant detection system
ApplicantFoundation Medicine, Inc.
150 Second St.
Cambridge, MA 02141
PMA NumberP200006
Date Received02/03/2020
Decision Date10/26/2020
APCB Date05/26/2023
Product Code PQP 
Docket Number 20M-2141
Notice Date 10/30/2020
Advisory Committee Pathology
Expedited Review Granted? No
Combination ProductNo
Predetermined Change Control Plan AuthorizedNo
RecallsCDRH Recalls
Approval Order Statement  
Approval for FoundationOne® Liquid CDx is a qualitative next generation sequencing based in vitro diagnostic test that uses targeted high throughput hybridization-based capture technology to detect and report substitutions, insertions and deletions (indels) in 311 genes, including rearrangements in three (3) genes, and copy number alterations in three (3) genes. FoundationOne® Liquid CDx utilizes circulating cell-free DNA (cfDNA) isolated from plasma derived from anti-coagulated peripheral whole blood of cancer patients collected in FoundationOne® Liquid CDx cfDNA blood collection tubes included in the FoundationOne® Liquid CDx Blood Sample Collection Kit. The test is intended to be used as a companion diagnostic to identify patients who may benefit from treatment with the targeted therapies listed in table 1 in accordance with the approved therapeutic product labeling.Table 1: Companion diagnostic indicationsTumor Type Biomarker(s) Detected TherapyNon-small cell lung cancer (NSCLC) EGFR Exon 19 deletions andEGFR Exon 21 L858R alteration IRESSA® (gefitinib)TAGRISSO® (osimertinib)TARCEVA® (erlotinib) ALK Rearrangements ALECENSA® (alectinib)Prostate cancer BRCA1, BRCA2 alterations RUBRACA® (rucaparib)Ovarian Cancer BRCA1, BRCA2 alterations RUBRACA® (rucaparib)Breast Cancer PIK3CA mutations C420R, E542K, E545A, E545D [1635G>T only], E545G, E545K, Q546E, Q546R, H1047L, H1047R, and H1047Y PIQRAY® (alpelisib)Additionally, FoundationOne® Liquid CDx is intended to provide tumor mutation profiling to be used by qualified health care professionals in accordance with professional guidelines in oncology for patients with solid malignant neoplasms.A negative result from a plasma specimen does not mean that the patient’s tumor is negative for genomic findings. Patients who are negative for the mutations listed in Table 1 should be reflexed to routine biopsy and their tumor mutation status confirmed using an FDA-approved tumor tissue test, if feasible.Genomic findings other than those listed in Table 1 of the intended use statement are not prescriptive or conclusive for labeled use of any specific therapeutic product. FoundationOne® Liquid CDx is a single-site assay performed at Foundation Medicine, Inc. in Cambridge, MA.
Approval OrderApproval Order
SummarySummary of Safety and Effectiveness
LabelingLabeling
Post-Approval StudyShow Report Schedule and Study Progress
Supplements:  S001 S003 S004 S002 
-
-