| | Class 2 Device Recall Presource Convenience Kit |  |
| Date Initiated by Firm | October 01, 2026 |
| Date Posted | November 13, 2026 |
| Recall Status1 |
Open3, Classified |
| Recall Number | Z-0466-2027 |
| Recall Event ID |
100062 |
| Product Classification |
Radiology-diagnostic kit - Product Code OIP
|
| Product | Presource Convenience kits containing recalled WelMed Extension Tubing Sets
ARTHROGRAM TRAY
SAN23AGDHF
MULTI PURPOSE RADIOLOGY PK
SANHDRPSM8
SANHDRPSME
MYELOGRAM PACK
SAN76MYMD1
SAN76MYMD3
SAN76MYMD5
SAN76MYMDB
MYELOGRAM TRAY
27-3296G
27-7212I
27-7212K
27-7212L
27-7212M
27-7824C
27-9143H
27-9143I
27-9143J
SAN26MYLE4
SAN26MYLEC
SAN26MYLED
MYELOGRAM TRAY LG
27-1256C
MYELOGRAM W NEEDLE DF
27-MY1CODA
MYELOGRAM WITHOUT NDL PACK
SAN32MYM14
SAN32MYM15
SAN32MYMEH
SAFETY MYELOGRAM TRAY
27-9456I |
| Code Information |
SAN23AGDHF
UDI-DI 10887488503806
Kit lots 518574
518643
SANHDRPSM8
UDI-DI 10197106587119
Kit lot 510336
SANHDRPSME
UDI-DI 10197106447970
Kit lots 510852
511350
511688
512205
512317
512901
513338
513809
514136
514137
514562
514848
515567
516633
516634
517039
517282
SAN76MYMD1
UDI-DI 10197106663622
Kit lot 276612
SAN76MYMD3
UDI-DI 10198956019553
Kit lot 487430
SAN76MYMD5
UDI-DI 10198956334922
Kit lot 709689
SAN76MYMDB
UDI-DI 10195594718558
Kit lots 323441
376027
401573
425919
620273
634219
647810
678358
27-3296G
UDI-DI 10195594558338
Kit lots 293937
297065
388989
406067
460257
478182
479366
496095
557253
581447
617864
654128
699278
703725
27-7212I
UDI-DI 10195594712242
Kit lots 232567
267819
288298
322684
346455
388280
406971
411956
419295
432736
457426
479345
497473
524736
27-7212K
UDI-DI 10198956185937
Kit lots 618265
646881
671301
27-7212L
UDI-DI 10198956388185
Kit lot 738547
27-7212M
UDI-DI 10198956437364
Kit lot 766277
27-7824C
UDI-DI 10195594780104
Kit lots 255502
533867
581818
617865
623622
631563
27-9143H
UDI-DI 10197106575888
Kit lot 510526
27-9143I
UDI-DI 10197106600986
Kit lots 510992
511339
511697
512053
512194
512981
513219
517295
517396
517578
518828
27-9143J
UDI-DI 10198956274273
Kit lot 520010
SAN26MYLE4
UDI-DI 10198956054394
Kit lot 501451
SAN26MYLEC
UDI-DI 10195594763831
Kit lots 391317
480479
SAN26MYLED
UDI-DI 10198956103160
Kit lots 565613
604720
694048
727363
741565
776209
792411
27-1256C
UDI-DI 10195594766924
Kit lots 511493
511575
512016
512934
514624
516973
518759
518899
518943
519169
519356
519705
27-MY1CODA
UDI-DI 10197106061718
Kit lots 185917
228545
260565
299745
333600
347998
370201
398019
428782
440060
453647
521400
524753
558769
616897
673455
712647
763483
SAN32MYM14
UDI-DI 10197106871461
Kit lot 514524
SAN32MYM15
UDI-DI 10198956301221
Kit lot 520209
SAN32MYMEH
UDI-DI 10195594173777
Kit lots 509544
509661
509662
509663
510350
510888
510983
511331
511842
513546
513547
513713
514610
514705
515353
515674
515931
516286
516287
516677
516678
517118
517119
517500
517501
517522
518072
518519
518901
519324
519534
519827
520520
520690
520869
520870
521168
27-9456I
UDI-DI 10197106427927
Kit lots 388281
585463
622939
744128
|
| FEI Number |
3001236905
|
Recalling Firm/ Manufacturer |
Cardinal Health 200, LLC
3651 Birchwood Dr
Waukegan
IL
60085-8337
|
| For Additional Information Contact | Janna Parks 847-887-1114 |
Manufacturer Reason for Recall | Kits include Extension Tubing Sets recalled by supplier WelMed. Affected tubing sets may leak. |
FDA Determined Cause 2 | Component design/selection |
| Action | Firm began notifying customers on October 1, 2026.
Prior to use, users should visually inspect the tubing connection area, including bonded junctions and connection points, for any visible irregularities, gaps, deformation, incomplete bonding, leakage, or other abnormalities consistent with the examples shown above.
If a defect is observed, or if leakage or connection difficulties are encountered during setup or priming, the product should not be used for patient care and discarded. Customers should report affected product through their normal complaint reporting process and retain the product for evaluation if requested.
Direct consignees were instructed to notify retail customers of the market action. |
| Quantity in Commerce | 1,155,430 |
| Distribution | Worldwide distribution - US Nationwide and the country of Canada. |
| Total Product Life Cycle | TPLC Device Report |
|
1 A record in this database is created when a firm initiates a correction or removal action. The record is updated if the FDA identifies a violation and classifies the action as a recall, and it is updated for a final time when the recall is terminated. Learn more about medical device recalls. 2 Per FDA policy, recall cause determinations are subject to modification up to the point of termination of the recall. 3 The manufacturer has initiated the recall and not all products have been corrected or removed. This record will be updated as the status changes.
|
|
|
|