| Part B: Supplementary Information Sheet (SIS) |
|
FR Recognition List Number
|
064
|
Date of Entry 04/04/2016
|
|
FR Recognition Number
|
13-81
|
| Standard | |
IEEE Std 11073-10419:2015 Health informatics - Personal health device communication - Part 10419: Device Specialization - Insulin Pump |
|
Identical AdoptionISO IEEE 11073-10419 First edition 2016-06-15 Health informatics - Personal health device communication - Part 10419: Device specialization - Insulin pump |
|
Scope/Abstract| This standard establishes a normative definition of communication between personal telehealth insulin pump devices (agents) and managers (e.g., cell phones, personal computers, personal health appliances, set top boxes) in a manner that enables plug-and-play interoperability. It leverages work done in other ISO/IEEE11073 standards including existing terminology, information profiles, application profile standards, and transport standards. It specifies the use of specific term codes, formats, and behaviors in telehealth environments, restricting optionality in base frameworks in favor of interoperability. This standard defines a common core functionality of personal telehealth insulin pump devices. In the context of personal health devices (PHDs), an insulin pump is a medical device used for the administration of insulin in the treatment of diabetes mellitus, also known as continuous subcutaneous insulin infusion (CSII) therapy. This standard provides the data modeling according to ISO/IEEE 11073-20601 and does not specify the measurement method. |
|
| Extent of Recognition
|
Rationale for Recognition
| This standard is relevant to medical devices and is recognized on its scientific and technical merit and/or because it supports existing regulatory policies. |
|
Transition Period
| FDA recognition of IEEE Std 11073-10419:2015 [Rec# 13-81] will be superseded by recognition of IEEE Std 11073-10419:2023 [Rec# 13-145]. FDA will accept declarations of conformity, in support of premarket submissions, to [Rec# 13-81] until July 4, 2027. After this transition period, declarations of conformity to [Rec# 13-81] will not be accepted. |
|
Public Law, CFR Citation(s) and Procode(s)*
| Regulation Number |
Device Name |
Device Class |
Product Code |
| §880.5725 |
Pump, Infusion, Insulin
|
Class 2
|
LZG
|
| §880.5725 |
Pump, Infusion, Insulin Bolus
|
Class 2
|
OPP
|
| N/A |
Pump, Infusion, Insulin, To Be Used With Invasive Glucose Sensor |
Class 3
|
OYC
|
| N/A |
Automated Insulin Dosing , Threshold Suspend |
Class 3
|
OZO
|
| N/A |
Automated Insulin Dosing Device System, Single Hormonal Control |
Class 3
|
OZP
|
|
Relevant FDA Guidance and/or Supportive Publications*
Guidance for Industry and Food and Drug Administration Staff - The Content of Investigational Device Exemption (IDE) and Premarket Approval (PMA) Applications for Artificial Pancreas Device Systems, 11/09/2012
Guidance on the Content of Premarket Notification [510(k)] Submissions for External Infusion Pumps, 03/01/1993
Infusion Pumps Total Product Life Cycle - Guidance for Industry and FDA Staff, 12/02/2014
Appropriate Use of Voluntary Consensus Standards in Premarket Submissions for Medical Devices - Guidance for Industry and Food and Drug Administration Staff, issued September 2018. |
|
| FDA Technical Contact
|
| Standards Development Organization
|
| FDA Specialty Task Group (STG)
|
|
|
| *These are provided as examples and others may be applicable. |