| | Class 2 Device Recall Lumenis |  |
| Date Initiated by Firm | August 29, 2006 |
| Date Posted | October 12, 2006 |
| Recall Status1 |
Terminated 3 on January 22, 2007 |
| Recall Number | Z-0028-2007 |
| Recall Event ID |
36188 |
| 510(K)Number | K011703 |
| Product Classification |
laser ablation - Product Code GEX
|
| Product | Lumenis brand DuoTome SideLite 550 Micron Delivery System; laser systems for ablating soft tissue.
Catalog Number: 0641-800-01; Manufactured by Lumenis, Inc., 2400 Condensa Street, Santa Clara, CA |
| Code Information |
Lot/Batch Numbers: 37600206, 38030206, 38470206, 39110306, 39660406, 40480506, 41040506, 42110606, 42550706, 37640206, 38120206, 38480206, 39200306, 39670406, 40490506, 41050506, 42120606, 42560706, 37650206, 38150206, 38510206, 39210306, 39680406, 40520506, 41080506, 42200606, 42570706, 37660206, 38160206, 38520206, 39220306, 39690406, 40530506, 41090506, 42210606, 42580706, 37700206, 38170206, 38530206, 39240306, 39770406, 40570506, 41100506, 42280606, 42650706, 37710206, 38200206, 38700306, 39250306, 39800406, 40580506, 41210506, 42290606, 42680706, 37720206, 38210206, 38710306, 39260306, 39810406, 40590506, 41310506, 42300606, 42740706, 37730206, 38230206, 38720306, 39270306, 39820406, 40600506, 41360506, 42310606, 42810706, 37740206, 38240206, 38730306, 39280306, 39830406, 40610506, 41390506, 42320606, 42890706, 37750206, 38300206, 38740306, 39460306, 39840406, 40690506, 41450506, 42330606, 43000706, 37760206, 38310206, 38800306, 39470306, 39880406, 40710506, 41470506, 42350606, 43010706, 37770206, 38380206, 38810306, 39530306, 39890406, 40720506, 41500506, 42360606, 43060706, 37800206, 38390206, 38830306 39540306, 39900406, 40730506, 41610606, 42380606, 43150706, 37810206, 38400206, 38840306, 39550306, 40180406, 40930506, 41750606, 42410606, 43190706, 37820206, 38410206, 38920306, 39560306, 40200406, 40940506, 41880606, 42420606, 43200706, 37890206, 38420206, 38930306, 39570306, 40340406, 40960506, 41890606, 42430606, 43210706, 37910206, 38430206, 38970306 39580306, 40390406, 40970506, 41900606, 42460706, 43220706, 37960206, 38440206, 38980306, 39590306, 40430406, 40980506, 41930606, 42490706, 43270706, 37970206, 38450206, 38990306, 39600306, 40460506, 41020506, 41990606, 42500706, 43280706, 37980206, 38460206, 39000306, 39650306, 40470506, 41030506, 42000606, 42540706, 43410706 |
Recalling Firm/ Manufacturer |
Lumenis Inc. 2400 Condensa St Santa Clara CA 95051-0901
|
| For Additional Information Contact | Ms. Lisa Scott 408-764-3303 |
Manufacturer Reason for Recall | Device lacks the black indicator markings on the metal tip and there is the potential for fiber degradation (detachment of the metal cap, and the fiber lasing straight) during use. |
FDA Determined Cause 2 | Other |
| Action | On 8/26/06, the firm initiated the recall and its notification was via letters and phone calls requesting return of affected product. |
| Quantity in Commerce | 10,815 |
| Distribution | Worldwide, including USA, Japan, Europe, Hong Kong, Russia and Canada. |
| Total Product Life Cycle | TPLC Device Report |
|
1 A record in this database is created when a firm initiates a correction or removal action. The record is updated if the FDA identifies a violation and classifies the action as a recall, and it is updated for a final time when the recall is terminated. Learn more about medical device recalls. 2 Per FDA policy, recall cause determinations are subject to modification up to the point of termination of the recall. 3 For details about termination of a recall see Code of Federal Regulations (CFR) Title 21 §7.55.
|
| 510(K) Database | 510(K)s with Product Code = GEX
|
|
|
|