• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: CARDINAL HEALTH, INC. KANGAROO; PUMP, INFUSION, ENTERAL

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

CARDINAL HEALTH, INC. KANGAROO; PUMP, INFUSION, ENTERAL Back to Search Results
Device Problem Device Displays Incorrect Message (2591)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 06/19/2019
Event Type  malfunction  
Event Description
Started tube feedings and 4 hours later the pump alarmed with system error 23.Covidien replaced cosmetic 3m bump-ons (plastic feet the pump sits on) - all tests passed testing inspections, returned to service.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
KANGAROO
Type of Device
PUMP, INFUSION, ENTERAL
Manufacturer (Section D)
CARDINAL HEALTH, INC.
15 hampshire street
mansfield MA 02048
MDR Report Key10017020
MDR Text Key189586380
Report Number10017020
Device Sequence Number1
Product Code LZH
Combination Product (y/n)N
Number of Events Reported1
Summary Report (Y/N)N
Report Source User Facility
Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date 04/22/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Other
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? Yes
Date Report Sent to FDA04/22/2020
Event Location Hospital
Date Report to Manufacturer05/01/2020
Initial Date Manufacturer Received Not provided
Initial Date FDA Received05/01/2020
Type of Device Usage N
Patient Sequence Number1
Patient Age22630 DA
-
-