• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: STAAR SURGICAL COMPANY IMPLANTABLE COLLAMER LENS (ICL); PHAKIC INTRAOCULAR LENS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

STAAR SURGICAL COMPANY IMPLANTABLE COLLAMER LENS (ICL); PHAKIC INTRAOCULAR LENS Back to Search Results
Model Number VICM5_12.6
Device Problem No Apparent Adverse Event (3189)
Patient Problem No Patient Involvement (2645)
Event Date 05/13/2020
Event Type  malfunction  
Manufacturer Narrative
This product is manufactured in the u.S.But not marketed in the u.S.No similar complaint was reported for units within the same lot.(b)(4).
 
Event Description
The reporter indicated a 12.6mm vicm5_12.6 implantable collamer lens, -9.50 diopter, was torn while being pulled through the cartridge during the loading process.There was no patient contact.The lens was exchanged for another same model/length lens on (b)(6) 2020 and the problem was resolved.The patient is happy.The cause of the event was unknown.
 
Manufacturer Narrative
Additional information : h3-device evaluation: lens returned in a micro-centrifuge vial with moisture on the lens.Visual inspection found optic torn and haptic torn.Claim# : (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
IMPLANTABLE COLLAMER LENS (ICL)
Type of Device
PHAKIC INTRAOCULAR LENS
Manufacturer (Section D)
STAAR SURGICAL COMPANY
1911 walker avenue
monrovia, ca
MDR Report Key10135965
MDR Text Key194649355
Report Number2023826-2020-01169
Device Sequence Number1
Product Code MTA
Combination Product (y/n)N
PMA/PMN Number
NA
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,health professional,o
Type of Report Initial,Followup
Report Date 05/15/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date09/30/2022
Device Model NumberVICM5_12.6
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer06/10/2020
Initial Date Manufacturer Received 05/15/2020
Initial Date FDA Received06/09/2020
Supplement Dates Manufacturer Received07/27/2020
Supplement Dates FDA Received08/27/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Treatment
CARTRIDGE MODEL SFC-45 - LOT # UNK; FOAM TIP PLUNGER MODEL FTP - LOT # UNK; INJECTOR MODEL MSI-PF - LOT # UNK
Patient Age38 YR
-
-