• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: RAYNHAM CODMAN DISPOS PERFORATOR; DISPOSABLE PERFORATORS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

RAYNHAM CODMAN DISPOS PERFORATOR; DISPOSABLE PERFORATORS Back to Search Results
Model Number 26-1221
Device Problem Unintended Ejection (1234)
Patient Problem Injury (2348)
Event Date 01/08/2020
Event Type  Injury  
Manufacturer Narrative
Attempts are being made to obtain additional information.Upon completion of the investigation, a follow-up report will be submitted.
 
Event Description
It was reported that the codman dispos perforator came off from the drill drive upon starting it prior to use on patient.The drill was reattached and started it again but it still came off from the drill.Therefore, it was replaced to a new one and the procedure was completed.The event lead to 30 minutes surgical delay.
 
Manufacturer Narrative
Updated fields- d4, d10, g4, g7, h2, h3, h4, h6, h10.Udi - (b)(4).Perforator was received for evaluation.Dhr- there is no indication that the production process may have contributed to this complaint failure analysis- the product was visually inspected with heavy organic matter, torn label and bone dust noted.Instruction for use testing and functional test was found to perform as intended.Complaint could not be verified.The perforator met all applicable acceptance criteria and tested to specifications.The root cause cannot be determined given the functional testing found the 261221 perforator met all applicable acceptance criteria.In addition, no issues relevant to the failure were noted from the dhr review, or trending, and proper finished goods testing was performed prior to release.Between 05nov2019 and 30jun2020, approximately 2,200 mdrs submitted electronically by integra lifesciences via trackwise, integra's complaint handling system, were not received by cdrh due to a computer system issue.Within this time period, an error with integra's middleware, which facilitates communications between trackwise and the fda system, caused the complaint records to close and indicate we had received an acknowledgement 3 from the fda when we had not.Integra interpreted the acknowledgement as a successful submission; however, subsequent investigation revealed the acknowledgement 3 received was from our middleware and not from the fda (these acknowledgements have been retained as part of the documentation of the mdr).The malfunction was related to the relocation of the trackwise application to a new data center during the transition of integra's corporate headquarters from plainsboro, nj to princeton, nj.Previously, integra had been successfully receiving acknowledgements 1, 2, and 3 from the fda, and our records reflect these acknowledgements, including the date and time stamps.Capa pr 229048 and nc 20-011 have been opened by integra to further investigate the nonconformance and develop a corrective action plan.The middleware error has been corrected, and integra has filed mdrs since the correction and verified that the appropriate acknowledgements have been received from the fda.Integra is resubmitting all impacted mdr reports for the time period 05nov2019 through 30jun2020.Integra lifesciences contacted (b)(4) office of product evaluation and quality on july 8-9, 2020 to report these issues regarding mdr reports.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CODMAN DISPOS PERFORATOR
Type of Device
DISPOSABLE PERFORATORS
Manufacturer (Section D)
RAYNHAM
325 paramount drive
325 paramount drive
raynham MA 02767
MDR Report Key10292995
MDR Text Key202707214
Report Number1226348-2020-00438
Device Sequence Number1
Product Code HBF
UDI-Device Identifier10886704005100
UDI-Public10886704005100
Combination Product (y/n)N
PMA/PMN Number
K791101
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type consumer,foreign,health profe
Type of Report Initial,Followup
Report Date 01/09/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? No
Device Operator Health Professional
Device Model Number26-1221
Device Catalogue Number261221
Device Lot NumberJ40Y26
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer03/05/2020
Initial Date Manufacturer Received 01/09/2020
Initial Date FDA Received07/17/2020
Supplement Dates Manufacturer Received05/20/2020
Supplement Dates FDA Received07/19/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-