TERUMO CARDIOVASCULAR SYSTEMS CORPORATION ADVANCED PERFUSION SYSTEM 1; CONSOLE, HEART-LUNG MACHINE, CARDIOPULMONARY BYPASS- ADVANCED PERFUSION SYSTEM 1 Back to Search Results
Model Number 816571
Device Problems Communication or Transmission Problem (2896); Output Problem (3005)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 07/07/2020
Event Type  malfunction  
Manufacturer Narrative
The reported complaint was confirmed per the data log analysis.The unit was not returned to the manufacturer therefore further evaluation could not be done.Per the manufacturer's subsidiary, the unit has been operating with no issues, and will return the unit should another issue arise.Per data log analysis, only the system log was provided.On (b)(6) 2020 a perfusion screen is opened at 08:24:29 am.At 08:25:46 am the arterial large roller pump reported an alarm.Most likely the pump had a low 5 volt (v) condition that caused the alarm.This would cause an alarm to sound and a red x on the pump icon as reported.At 08:33:31 am the art pump was reassigned to the vent position.Another alarm is reported on the pump and the perfusion screen is exited at 08:38:50 am.The log confirms the complaint.If additional information becomes available on this complaint that would alter the facts and/or conclusion, a supplemental report will be filed accordingly.
 
Event Description
It was reported that prior to use of the device for a cardiopulmonary bypass (cpb) procedure, the central control monitor (ccm) displayed an 'x' over the pump icon.As a result, an alternative device was employed.The surgical procedure was completed successfully.There was no delay, no blood loss, nor adverse consequence to the patient.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ADVANCED PERFUSION SYSTEM 1
Type of Device
CONSOLE, HEART-LUNG MACHINE, CARDIOPULMONARY BYPASS- ADVANCED PERFUSION SYSTEM 1
Manufacturer (Section D)
TERUMO CARDIOVASCULAR SYSTEMS CORPORATION
6200 jackson road
ann arbor MI 48103
Manufacturer (Section G)
SAME
Manufacturer Contact
douglas patton
6200 jackson road
ann arbor, MI 48103
7346634145
MDR Report Key10347224
MDR Text Key201561714
Report Number1828100-2020-00279
Device Sequence Number1
Product Code DTQ
Combination Product (y/n)N
Reporter Country CodeKS
PMA/PMN Number
K022947
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date 07/30/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number816571
Device Catalogue Number6885
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Initial Date Manufacturer Received 07/07/2020
Initial Date FDA Received07/30/2020
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured02/16/2012
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
-
-