• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: MEDTRONIC CRYOCATH LP ARCTIC FRONT ADVANCE CARDIAC CRYOABLATION CATHETER; PERCUTANEOUS CATHETER INTENDED FOR TREATMENT OF ATRIAL FIBRILLATION

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

MEDTRONIC CRYOCATH LP ARCTIC FRONT ADVANCE CARDIAC CRYOABLATION CATHETER; PERCUTANEOUS CATHETER INTENDED FOR TREATMENT OF ATRIAL FIBRILLATION Back to Search Results
Model Number 2AF284
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Stroke/CVA (1770); Nerve Damage (1979); Transient Ischemic Attack (2109); Pericardial Effusion (3271)
Event Date 01/01/2020
Event Type  Injury  
Manufacturer Narrative
Concomitant medical products: achieve mapping catheter medtronic was made aware of this event through a search of literature publications.It was not possible to ascertain specific device information from the literature publication or to match the event with previously reported events.This information is based entirely on journal literature.This event occurred outside the us.All information provided is included in this report.Of note, multiple patients/multiple methods/multiple manufacturers were noted in the article; however, a one to one correlation could not be made with unique product lot/serial numbers/methods/manufacturers.The overall baseline gender characteristics is male; the age of the patients was approximately 63 years old.Without a lot number or device serial number, the manufacturing date cannot be determined.Since no device id was provided, it is unknown if this event has been previously reported.A request for additional information will be made and upon receipt a supplemental report will be submitted accordingly.Referenced article: ¿comparative study of cryoballoon versus radiofrequency for pulmonary vein isolation when combined with vein of marshall ethanol infusion for paroxysmal atrial fibrillation.¿ journal of atrial fibrillation.2020; 12(5):1-8.Doi: 10.4022/jafib.2253.If information is provided in the future, a supplemental report will be issued.
 
Event Description
The literature publication reported the following patient complications during a procedure using a cryoballoon ablation catheter system.There were three (3) patients who experienced pericardial effusion; with unknown treatment/resolution indicated.There were 40 patients who had an asymptomatic stroke/ transient ischemic attack (tia); with no indication of any sequelae.There was also one (1) patient who had ¿sustained¿ phrenic nerve palsy (pnp), with no indication of treatment/resolution.Of note, multiple patients/multiple methods/multiple manufacturers were noted in the article; however, a one to one correlation could not be made with unique product lot/serial numbers/methods/manufacturers.The status/location of the cryoballoon catheter system is unknown.Further follow up did not yet yield any additional information.No further patient complications have been reported as a result of this event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ARCTIC FRONT ADVANCE CARDIAC CRYOABLATION CATHETER
Type of Device
PERCUTANEOUS CATHETER INTENDED FOR TREATMENT OF ATRIAL FIBRILLATION
Manufacturer (Section D)
MEDTRONIC CRYOCATH LP
9000 autoroute transcanadienne
pointe-claire,qc H9R 5 Z8
CA  H9R 5Z8
Manufacturer (Section G)
MEDTRONIC CRYOCATH LP
9000 autoroute transcanadienne
pointe-claire,qc H9R 5 Z8
CA   H9R 5Z8
Manufacturer Contact
paula bixby
8200 coral sea st ne
mounds view, MN 55112
7635055378
MDR Report Key10446139
MDR Text Key204190748
Report Number3002648230-2020-00441
Device Sequence Number1
Product Code OAE
Combination Product (y/n)N
Reporter Country CodeJA
PMA/PMN Number
P100010
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,health professional,l
Reporter Occupation Physician
Type of Report Initial
Report Date 08/24/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Model Number2AF284
Device Catalogue Number2AF284
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 07/28/2020
Initial Date FDA Received08/24/2020
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Hospitalization; Life Threatening; Required Intervention;
Patient Age63 YR
-
-