BOSTON SCIENTIFIC CORPORATION INTUA; PULSE GENERATOR, PACEMAKER, IMPLANTABLE, WITH CARDIAC RESYNCHRONIZATION (CRT-P) Back to Search Results
Model Number V273
Device Problems Pocket Stimulation (1463); Incorrect, Inadequate or Imprecise Result or Readings (1535)
Patient Problems Muscle Stimulation (1412); Device Overstimulation of Tissue (1991); No Code Available (3191)
Event Date 08/19/2020
Event Type  Injury  
Manufacturer Narrative
(b)(4).The device has not been returned at this time.If it is returned, analysis will be performed and this report will be updated.
 
Event Description
It was reported that the patient implanted with this cardiac resynchronization therapy pacemaker (crt-p) presented to the emergency room due to phrenic nerve stimulation.The device was found to be operating in safety mode.The device was subsequently explanted and replaced.No additional adverse patient effects were reported.
 
Event Description
It was reported that the patient implanted with this cardiac resynchronization therapy pacemaker (crt-p) presented to the emergency room due to phrenic nerve stimulation.The device was found to be operating in safety mode.The device was subsequently explanted and replaced.No additional adverse patient effects were reported.
 
Manufacturer Narrative
Patient code 3191 is being used to capture the additional intervention performed.The device has not been returned at this time.If it is returned, analysis will be performed and this report will be updated.Upon receipt at our post market quality assurance laboratory, this device was thoroughly inspected and analyzed.Interrogation of the device confirmed it was operating in safety mode due to system resets.It was confirmed that brady therapy remained available.The system resets occurred during a telemetry session and caused the device to enter safety mode.Engineers determined that this device was demonstrating behavior consistent with a high internal cell impedance within the battery.The high internal impedance resulted in the system resets due to temporary high-power consumption related to telemetry attempts and subsequent reversion to safety mode operation.Boston scientific has issued a field safety notice regarding ingenio extended life (el) and cardiac resynchronization therapy pacemaker (crt-p) devices that may exhibit this behavior.This particular device is included in the high impedance in ingenio extended life (el) pacemaker and crt-p advisory population.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
INTUA
Type of Device
PULSE GENERATOR, PACEMAKER, IMPLANTABLE, WITH CARDIAC RESYNCHRONIZATION (CRT-P)
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
4100 hamline avenue north
saint paul MN 55112
MDR Report Key10621732
MDR Text Key209639479
Report Number2124215-2020-17894
Device Sequence Number1
Product Code NKE
UDI-Device Identifier00802526536670
UDI-Public00802526536670
Combination Product (y/n)N
PMA/PMN Number
P030005/S092
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative
Remedial Action Notification
Type of Report Initial,Followup
Report Date 10/14/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Lay User/Patient
Device Expiration Date08/07/2016
Device Model NumberV273
Device Catalogue NumberV273
Device Lot Number101041
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/11/2020
Initial Date Manufacturer Received 08/19/2020
Initial Date FDA Received10/02/2020
Supplement Dates Manufacturer Received08/10/2021
Supplement Dates FDA Received10/14/2021
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Outcome(s) Hospitalization; Required Intervention;
Patient Age72 YR
-
-