Model Number 130790030
Device Problem Fracture (1260)
Patient Problems Not Applicable (3189); No Code Available (3191)
Event Date 09/22/2020
Event Type  malfunction  
Manufacturer Narrative
Product complaint # (b)(4).If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event Description
During a case at (b)(6) hospital today for a reverse shoulder (using the delta xtend prostheses) one of the heads of the locking screws snapped off making it obsolete and causing great delay to the case time itself.Eventually the surgeon had to cut the top of the head off using a small frag set as attempting a full extraction would have caused too much aggravation to the shoulder in an already complex case.
 
Manufacturer Narrative
Product complaint # (b)(4).Investigation summary: no device associated with this report was received for examination.Review of the attached photograph identified damaged screw fragments.A worldwide complaint database search found no other related reported incidents against the provided product code/lot number combination since release for distribution.The information received will be retained for potential series investigations if triggered by trend analysis, post market surveillance, or other events within the quality system.Device history lot: a search of the depuy nonconformance (nc) quality system found no nc¿s associated with this product/lot combination.
 
Manufacturer Narrative
Product complaint # (b)(4).This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by depuy synthes joint reconstruction, or its employees that the report constitutes an admission that the product, depuy synthes joint reconstruction, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
DXTEND SCREW LOCK D4.5X30MM
Type of Device
DELTA XTEND IMPLANTS : SCREWS
Manufacturer (Section D)
DEPUY FRANCE SAS - 3003895575
7 allee irene joliot-curie
b.p. 256
saint priest cedex 69801
FR  69801
MDR Report Key10643086
MDR Text Key210248368
Report Number1818910-2020-21708
Device Sequence Number1
Product Code HSD
UDI-Device Identifier10603295027843
UDI-Public10603295027843
Combination Product (y/n)N
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,health professional
Type of Report Initial,Followup,Followup
Report Date 09/22/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number130790030
Device Catalogue Number130790030
Device Lot Number5367488
Was Device Available for Evaluation? No
Initial Date Manufacturer Received 09/22/2020
Initial Date FDA Received10/07/2020
Supplement Dates Manufacturer Received09/22/2020
12/08/2020
Supplement Dates FDA Received10/14/2020
12/08/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Treatment
DXTEND SCREW LOCK D4.5X30MM; DXTEND SCREW LOCK D4.5X30 MM
-
-