Model Number 801188
Device Problems Calibration Problem (2890); Output Problem (3005)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 10/15/2020
Event Type  malfunction  
Manufacturer Narrative
The field service representative (fsr) duplicated the calibration failure.He replaced the oxygen (o2) sensor.The unit operated to the manufacturer's specifications.The suspect device was sent back to the manufacturer for further evaluation.
 
Event Description
It was reported that the electronic patient gas system (epgs) displayed a "failure to calibrate gas" error message.No other details regarding the nature of this event were provided.
 
Manufacturer Narrative
During laboratory analysis, the product surveillance technician could not duplicate the reported complaint.The returned oxygen sensor was installed into a lab use only electronic patient gas system and calibrated three consecutive times.
 
Manufacturer Narrative
The reported complaint was confirmed.Per the data log review on (b)(6) 2020, each time the gas system calibration was attempted it failed with a 'o2 sensor out of range at calibration' (sensor value = 0) message.This indicated a bad o2 sensor or a connection issue to the sensor.The data log confirms the complaint.If additional information becomes available on this complaint that would alter the facts and/or conclusion, a supplemental report will be filed accordingly.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ADVANCED PERFUSION SYSTEM 1
Type of Device
CONSOLE, HEART-LUNG MACHINE, CARDIOPULMONARY BYPASS- ADVANCED PERFUSION SYSTEM 1
Manufacturer (Section D)
TERUMO CARDIOVASCULAR SYSTEMS CORPORATION
6200 jackson road
ann arbor MI 48103
MDR Report Key10813393
MDR Text Key215518629
Report Number1828100-2020-00429
Device Sequence Number1
Product Code DTQ
UDI-Device Identifier00886799000588
UDI-Public(01)00886799000588(11)100623
Combination Product (y/n)N
PMA/PMN Number
K172220
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Type of Report Initial,Followup,Followup
Report Date 12/16/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number801188
Device Catalogue Number801188
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer10/29/2020
Was the Report Sent to FDA? No
Initial Date Manufacturer Received 10/21/2020
Initial Date FDA Received11/09/2020
Supplement Dates Manufacturer Received10/29/2020
12/01/2020
Supplement Dates FDA Received11/23/2020
12/16/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-