Model Number 72202397
Device Problems Break (1069); Material Separation (1562)
Patient Problems No Information (3190); No Clinical Signs, Symptoms or Conditions (4582)
Event Date 10/21/2020
Event Type  Injury  
Manufacturer Narrative
Foreign zip code: (b)(6).
 
Event Description
It was reported that the bioraptor anchor snapped on insertion.The malfunction was solved with a delay shorter than 30 minutes using a back up device.No further complications were reported.All available information has been disclosed.If additional information should become available, a supplemental report will be submitted accordingly.
 
Event Description
It was reported that during procedure, two anchors snapped on insertion.All the pieces were removed from the patient.The malfunction was solved with a delay shorter than 30 minutes using a back up device.No further complications were reported.
 
Manufacturer Narrative
H10: internal complaint reference: (b)(4).H3, h6: the reported device was received for evaluation.There was a relationship found between the device and the reported event.A complaint history review found similar reported events.A review of device records showed there were no indications to suggest that the product did not meet manufacturing specification upon release for distribution.The instructions for use was reviewed and found to include conditions of off label use and technique specifics, as well as precautions and warnings related to the use of the device.A risk management review found that the reported failure was documented appropriately, and there were no indications to suggest the anticipated risk is not adequate.A review of the polymer found that the storage requirements, material specifications, and applicable tests were appropriately specified.A material certificate of analysis was required for the raw material.A visual inspection of the returned device found that it is not in its original packaging.There were two devices returned.A visual inspection of device one found that the inserter has been driven through the plug of the anchor.The plug is attached to the inserter.The anchor body and sutures were not returned with the device.There is debris on the device.A visual inspection of device two found that the inserter has been driven through the plug of the anchor.The plug is attached to the inserter.The anchor body and sutures were not returned with the device.There is debris on the device.Based on the condition of the product material found during visual inspection, additional material testing is not required.No patient injuries or adverse consequences were reported.Since no patient injuries are being reported no further clinical/medical assessment is warranted at this time.The complaint was confirmed, and the root cause was associated with unintended use of the device.Factors that could have contributed to the reported event include excessive force on the device, excessive torque on the device, attempted correction of a damaged device, off-axis insertion, improper preparation of the insertion site, or an inadvertent impact event inconsistent with normal use.Please refer to the instructions for use for recommendations on proper use of the device and potential troubleshooting methods to prevent future reoccurrence of the reported event.No containment or corrective actions are recommended at this time.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BIORAPTOR KNOTLESS SUTURE ANCHOR HIP
Type of Device
FASTENER, FIXATION, NONDEGRADABLE, SOFT TISSUE
Manufacturer (Section D)
SMITH & NEPHEW, INC.
130 forbes blvd.
mansfield MA 02048
Manufacturer (Section G)
SMITH & NEPHEW, INC.
130 forbes blvd.
mansfield MA 02048
Manufacturer Contact
holly topping
7000 west william cannon drive
austin, TX 78735
5123913905
MDR Report Key10818775
MDR Text Key215592807
Report Number1219602-2020-01815
Device Sequence Number1
Product Code MBI
UDI-Device Identifier03596010651280
UDI-Public03596010651280
Combination Product (y/n)N
Reporter Country CodeAS
PMA/PMN Number
K093428
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Other,Foreign,Health Professional,User Facility,Company Representative
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 11/22/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date05/29/2024
Device Model Number72202397
Device Catalogue Number72202397
Device Lot Number2034461
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 10/21/2020
Initial Date FDA Received11/10/2020
Supplement Dates Manufacturer Received10/21/2020
Supplement Dates FDA Received11/22/2022
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured05/29/2019
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1