Model Number MI2355A
Device Problems Leak/Splash (1354); Use of Device Problem (1670)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 10/23/2020
Event Type  malfunction  
Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Event Description
It was reported that during implant of the leadless implantable pulse generator (ipg), when the inner dilator was pulled, the doctor could not pull back blood.It was noted that his syringe was pulling air only.He plugged the sheath opening and tried several more times.Upon fluoroscopy he saw what he felt to be air going into patients right atrium and pulled the sheath out.The leadless ipg was not used and was replaced.No patient complications have been reported as a result of this event.
 
Manufacturer Narrative
Product event summary: the introducer was returned and analyzed.The delivery system introducer flush tube was kinked/buckled.Visual analysis of the introducer indicated damage during use.The analyst noted the introducer was flushed and did not leak.The flush tube was kinked and impeded flow.Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
 
Manufacturer Narrative
Product event summary: the introducer was returned and analyzed.The distal seal of the delivery system introducer was torn.The delivery system introducer flush tube was kinked/buckled.Blood was observed on the delivery system introducer distal seal.Blood was observed on the delivery system introducer proximal seal.The analyst noted the flush tube of the side port assembly was kinked at the base of the ferrule on the seal housing.Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
MICRA
Type of Device
INTRODUCER, CATHETER
Manufacturer (Section D)
MEDTRONIC IRELAND
parkmore business park west
galway,ie
Manufacturer (Section G)
MEDTRONIC IRELAND
parkmore business park west
galway,ie
Manufacturer Contact
paula bixby
8200 coral sea st ne
mounds view, MN 
7635055378
MDR Report Key10842178
MDR Text Key216362675
Report Number9612164-2020-04421
Device Sequence Number1
Product Code DYB
UDI-Device Identifier00643169359888
UDI-Public00643169359888
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K132030
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional,Company Representative
Reporter Occupation Physician
Type of Report Initial,Followup,Followup
Report Date 04/17/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date01/03/2022
Device Model NumberMI2355A
Device Catalogue NumberMI2355A
Device Lot Number00147459
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer10/28/2020
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 10/23/2020
Initial Date FDA Received11/16/2020
Supplement Dates Manufacturer Received11/18/2020
03/29/2023
Supplement Dates FDA Received11/20/2020
04/17/2023
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured01/04/2020
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Age87 YR
Patient SexMale
-
-