|
Model Number 778624 |
Device Problem
Material Twisted/Bent (2981)
|
Patient Problems
No Code Available (3191); Appropriate Clinical Signs, Symptoms, Conditions Term / Code Not Available (4581)
|
Event Date 12/17/2020 |
Event Type
Injury
|
Manufacturer Narrative
|
The investigation is still in progress.Once the investigation is complete a supplemental report will be filed.The information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
|
Event Description
|
It was reported that the string of urethral stent seemed to be bit thicker than normal and it did not move very well through the cystoscope.While the surgeon was attempting to place it, the string tugged and tangled.So, the entire stent had to be removed.Hence, the string could be cut off and the stent could be replaced.Per follow up response received via mail on (b)(6) 2020, the stent was removed and the string had to be cut, which resulted in an additional procedure for the patient to have it removed.
|
|
Event Description
|
It was reported that the string of urethral stent seemed to be bit thicker than normal and it did not move very well through the cystoscope.While the surgeon was attempting to place it, the string tugged and tangled.So, the entire stent had to be removed.Hence, the string could be cut off and the stent could be replaced.Per follow up response received via mail on (b)(6)2020, the stent was removed and the string had to be cut, which resulted in an additional procedure for the patient to have it removed.
|
|
Manufacturer Narrative
|
The reported event was inconclusive as no sample was returned for evaluation.A potential root cause could be due to "material selection".It was unknown whether the device had met specifications.The product was used for treatment but it was unknown whether the product had caused the reported failure.The device history record was reviewed and found nothing that could have caused or contributed to the reported event.The instructions for use were found adequate and state the following: "directions for use: 1.Determine the proper stent length for the patient.This is generally calculated from the baseline pyelogram.Accurate measurements will optimize drainage efficiency and patient comfort.Submerge stent in sterile water to activate the coating.2.Insert the cystoscope then pass the guidewire* through the scope until the tip is in the renal pelvis.3.Move the pigtail straightener over the proximal end (kidney coil end) of the ureteral stent allowing easier insertion onto the guidewire.Remove pigtail straightener once the stent is secure on the guidewire.4.Pass the stent over the guidewire through the cystoscope by using the push catheter for proper placement.5.Watch the distal end (bladder coil end) of the stent or the radiopaque, proximal end of the pusher.Stop advancing when the stent¿s distal end marker reaches the ureterovesical junction (uvj).**(see below for proper placement directions on the multi-length ureteral stent.) 6.Withdraw the guidewire slowly.The stent will form a pigtail automatically.7.Carefully remove the push catheter.*activate the guidewire coating according to the ¿instructions for use¿ found within the guidewire packaging.**multi-length ureteral stent placement: to accurately size this stent count the marker bands as it is being advanced into the ureter.The first large band indicates the 22cm length.The second and third bands indicate 24cm and 26cm lengths respectively.The last large band is the 28cm length.If you need to place for the 30cm and 32cm lengths, use the attached suture or endoscopic forceps to gently pull back on the stent unwinding the coil from the kidney." section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
|
Search Alerts/Recalls
|
|
|