Model Number D-AVHD-DF16
Device Problems Entrapment of Device (1212); Fracture (1260); Difficult to Remove (1528)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 01/08/2021
Event Type  malfunction  
Manufacturer Narrative
The results of the investigation are inconclusive since the device was not returned for analysis.The device history record was reviewed to ensure that each manufacturing and inspection operation was performed.Based on the information received, the cause of the reported entanglement and catheter tip fracture could not be conclusively determined.
 
Event Description
During the procedure, when a long sheath was inserted into the patient, the sheath went through the splines of the catheter and the two became entangled.An attempt was made to remove the catheter through its own long sheath while the second long sheath was still through it, however the two remained entangled.In an attempt to pull the catheter out, the metal connector at the tip of the catheter was fractured.The second long sheath was pulled back until it was no longer through the catheter and the catheter was removed successfully.The catheter was exchanged and the procedure was completed and there was no adverse patient consequence.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ADVISOR HD GRID MAPPING CATHETER, SENSOR ENABLED
Type of Device
CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING
Manufacturer (Section D)
ST. JUDE MEDICAL
5050 nathan lane north
plymouth MN 55442
Manufacturer (Section G)
ST. JUDE MEDICAL
5050 nathan lane north
plymouth MN 55442
Manufacturer Contact
stephanie o' sullivan
5050 nathan lane north
plymouth, MN 55442
6517565400
MDR Report Key11178655
MDR Text Key227075630
Report Number3005334138-2021-00011
Device Sequence Number1
Product Code DRF
UDI-Device Identifier05415067028198
UDI-Public05415067028198
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K172393
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Reporter Occupation Physician
Type of Report Initial
Report Date 01/15/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date10/31/2023
Device Model NumberD-AVHD-DF16
Device Catalogue NumberD-AVHD-DF16
Device Lot Number7746417
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Initial Date Manufacturer Received 01/10/2021
Initial Date FDA Received01/15/2021
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured11/19/2020
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Age23 YR
-
-