Catalog Number 826631
Device Problem No Device Output (1435)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 01/04/2021
Event Type  malfunction  
Manufacturer Narrative
An investigation has been initiated based on the reported information.Upon completion of the investigation, a follow-up report will be submitted.
 
Event Description
A facility reported that on (b)(6) 2021 a codman neuromonitor basic kit microsensor was implanted into a patient after being zeroed.When connected to the icp, the physician found that no reading was shown.The physician changed out the device with another of the same device which was used normally.No delay was noted.
 
Manufacturer Narrative
The microsensor was returned for evaluation.Device history record (dhr) - the product code 82-6631 with lot 3943128 conformed to the specifications when released to stock.Failure analysis - the issue of the complaint was not confirmed: no visible damage to the millar sensor, catheter material, or connector.The icp express reading passed with 549.The device passed electronic, noise, linearity/hysteresis, and signal drift tests.The root cause of the issue reported by customer could not be determined as the device worked correctly.However, the possible root cause of the defect reported by the customer could be due to excessive pressure applied to product.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
NEUROMONITOR BASIC KIT
Type of Device
ICP MICROSENSORS
Manufacturer (Section D)
INTEGRA LIFESCIENCES SWITZERLAND SAR
rue girardet 29
rue girardet 29
le locle
SZ 
MDR Report Key11219619
MDR Text Key234255622
Report Number3013886523-2021-00033
Device Sequence Number1
Product Code GWM
Combination Product (y/n)N
PMA/PMN Number
K914479
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign
Type of Report Initial,Followup
Report Date 07/29/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number826631
Device Lot Number3943128
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer05/06/2021
Initial Date Manufacturer Received 01/04/2021
Initial Date FDA Received01/22/2021
Supplement Dates Manufacturer Received07/08/2021
Supplement Dates FDA Received07/29/2021
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-