• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BAXTER HEALTHCARE CORPORATION PRISMAFLEX M100; DIALYZER, HIGH PERMEABILITY WITH OR WITHOUT SEALED DIALYSATE SYSTEM

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BAXTER HEALTHCARE CORPORATION PRISMAFLEX M100; DIALYZER, HIGH PERMEABILITY WITH OR WITHOUT SEALED DIALYSATE SYSTEM Back to Search Results
Catalog Number 106697
Device Problems Disconnection (1171); Leak/Splash (1354)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 01/25/2021
Event Type  malfunction  
Manufacturer Narrative
Initial reporter address: (b)(6).Should additional relevant information become available, a supplemental report will be submitted.
 
Event Description
It was reported that an external blood leak was observed during treatment with a prismaflex m100 set.It was reported that the blood tubing came apart from the filter set and the patient experienced a major blood loss (amount not specified).There was no patient injury or medical intervention associated with this event.No additional information is available.
 
Manufacturer Narrative
Additional information added to h10.H10: the device was not received for evaluation, however, a photograph was provided for investigation.The visual inspection observed that the return screwed connector was disconnected from the filter.The component was not broken.The reported condition was verified.The cause could not be determined.Should additional relevant information become available, a supplemental report will be submitted.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PRISMAFLEX M100
Type of Device
DIALYZER, HIGH PERMEABILITY WITH OR WITHOUT SEALED DIALYSATE SYSTEM
Manufacturer (Section D)
BAXTER HEALTHCARE CORPORATION
deerfield IL
MDR Report Key11331356
MDR Text Key247046336
Report Number8010182-2021-00052
Device Sequence Number1
Product Code KDI
Combination Product (y/n)Y
PMA/PMN Number
K041005
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Type of Report Initial,Followup
Report Date 03/17/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number106697
Device Lot Number20G2206
Was Device Available for Evaluation? No
Initial Date Manufacturer Received 01/25/2021
Initial Date FDA Received02/16/2021
Supplement Dates Manufacturer Received03/15/2021
Supplement Dates FDA Received03/17/2021
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Treatment
PRISMAFLEX MACHINE
-
-