Catalog Number H938741
Device Problem Fluid/Blood Leak (1250)
Patient Problem No Patient Involvement (2645)
Event Date 01/26/2021
Event Type  malfunction  
Manufacturer Narrative
Should additional relevant information become available, a supplemental report will be submitted.
 
Event Description
It was reported that a 3000ml eva (ethyl vinyl acetate) tpn (total parenteral nutrition) bag was defective.The defect was further described as leak coming from the seam on the top of the primary container.This issue was identified during compounding prior to patient use.There was no patient involvement.No additional information is available.
 
Manufacturer Narrative
Additional information was added to d4 expiration and udi #, d9, h3, h4 and h6.H4: the lot was manufactured from september 25, 2020 - september 28, 2020.H10: the device was received for evaluation.Visual inspection did not identify any abnormalities that could have contributed to the reported condition.Functional testing was performed with tap water which revealed a leak from the top left side seam in back of the bag.Additional magnified inspection verified a small tear/hole where the leak occurred.The reported condition was verified.The cause of the tear/hole could not be determined.A batch review was conducted and there were no deviations found related to this reported condition during the manufacture of this lot.Should additional relevant information become available, a supplemental report will be submitted.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
3000 ML TPN BAG
Type of Device
SET, I.V. FLUID TRANSFER
Manufacturer (Section D)
BAXTER HEALTHCARE CORPORATION
deerfield IL
MDR Report Key11344004
MDR Text Key232836937
Report Number1416980-2021-00721
Device Sequence Number1
Product Code LHI
Combination Product (y/n)Y
PMA/PMN Number
K900585
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Type of Report Initial,Followup
Report Date 03/22/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Other
Device Expiration Date08/31/2023
Device Catalogue NumberH938741
Device Lot Number60259867
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer02/02/2021
Initial Date Manufacturer Received 01/27/2021
Initial Date FDA Received02/18/2021
Supplement Dates Manufacturer Received03/10/2021
Supplement Dates FDA Received03/22/2021
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-