This report is being submitted in pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by mitek or its employees that the report constitutes an admission that the device, mitek, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.H10 additional narrative: d9, h3, h6: the actual device has been returned and is currently pending evaluation.Once reliability engineering evaluates the device, a supplemental medwatch report will be sent accordingly.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
This report is being submitted in pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by mitek or its employees that the report constitutes an admission that the device, mitek, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.Investigation summary : according to the information received, it was reported that during the surgery of meniscus repair, could not fire.Another device was used to complete the surgery.No additional information could be provided.The product was returned to mitek for evaluation.Mitek then conducted visual inspection of device received provided by customer.The complaint device was received and inspected.The sleeve was cut to see the internal condition; as a result, the implants and suture were received along with the needle, they were not deployed.When test its functionality, it was also observed that the trigger was loose, in that there was no tension on the handle from the spring.Therefore, the gun was opened, and it was found that the initial part of the trigger was broken and disconnected from the firing spring, it indicates that the internal mechanism of the handle was not working.A manufacturing record evaluation was performed for the finished device lot number: 6l54946, and no nonconformances were identified.No information was provided on how or when the failure has occurred, therefore a definitive root cause could not be determined.This type of issue was reviewed with the manufacturer, based on the information received, the process of the truespan have two phases where the deployment gun is checked (the step of applier functional testing and the implant system routing check), this test guaranties the applier has been properly assembled and is functional.This information correspond to a process control and it is the appropriate document to use to guarantee that this issue can¿t have happened during manufacturing process.The possible root cause for the reported failure could be related when not inserting the needle to the proper depth for deployment which have caused that the implant not be deployed as intended which could cause stuck.When attempted to fire the implant against the tissue, it can feel a resistance and excessive force could have caused stress on the handle thus causing the handle mechanism to break.However, it cannot be conclusively affirmed.As per ifu, for the needle insertion, it is necessary use a calibrated probe, measure the width of the meniscal tissue to help insert into the joint.Set the adjustable depth stop to minimize tissue penetration depth.Also, during needle insertion use a malleable graft retractor or slotted cannula to prevent the needle from catching on or damaging tissue.As part of mitek¿s quality process all devices are manufactured, inspected, and released to approved specifications.At this point in time, no corrective action is required, and no further action is warranted.However, in depuy synthes mitek, additional complaint information monitoring for potential safety signals is conducted through complaint trending as part of post market surveillance.
|