Model Number MDT-ICD
Device Problems Electromagnetic Interference (1194); Over-Sensing (1438); Inappropriate/Inadequate Shock/Stimulation (1574)
Patient Problem Shock from Patient Lead(s) (3162)
Event Date 02/09/2021
Event Type  Injury  
Manufacturer Narrative
This information is based entirely on journal literature.Medtronic was made aware of this event through a search of literature publications.This event occurred outside the us.Patient information is limited due to confidentiality concerns.Of note, multiple patients and multiple manufacturers were noted in the article; however, a one to one correlation could not be made with unique product serial/lot numbers.The baseline gender/age characteristics is male/65 years old.The model listed in the report is a representative of the model family, as there is no specific model listed.Without a lot number or device serial number, the manufacturing date cannot be determined.Since no device id was provided, it is unknown if this event has been previously reported.A request for additional information will be made and upon receipt a supplemental report will be submitted accordingly.Referenced article: novel implantable cardioverter defibrillator programming with high rate cut-off, long detection intervals and multiple anti-tachycardia pacing reduces mortality.Circulation journal.2021.85: 291 ¿ 299.Doi: 10.1253/circj.Cj-20-0940.If information is provided in the future, a supplemental report will be issued.
 
Event Description
A journal article was reviewed that contained information regarding novel programming of implantable cardioverter defibrillators (icd).The article reports patients that experienced inappropriate therapy due to supraventricular arrhythmias, electromagnetic interference, and/or oversensing due to the lead.The status/ disposition of the devices and leads is unknown.No further patient complications have been reported as a result of this event.Further follow up did not yet yield any additional information.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
MEDTRONIC ICD
Type of Device
PULSE-GENERATOR, PACEMAKER, IMPLANTABLE
Manufacturer (Section D)
MEDTRONIC, INC.
8200 coral sea street ne
mounds view MN 55112
Manufacturer (Section G)
MEDTRONIC, INC.
8200 coral sea street ne
mounds view MN 55112
Manufacturer Contact
paula bixby
8200 coral sea st ne
mounds view, MN 55112
7635055378
MDR Report Key11675383
MDR Text Key245746686
Report Number2182208-2021-01499
Device Sequence Number1
Product Code DXY
Combination Product (y/n)N
Reporter Country CodeGM
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,health professional,l
Reporter Occupation Physician
Type of Report Initial
Report Date 04/15/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Lay User/Patient
Device Model NumberMDT-ICD
Device Catalogue NumberMDT-ICD
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 04/02/2021
Initial Date FDA Received04/15/2021
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Life Threatening;
Patient Age65 YR
-
-