Model Number 221239
Device Problem Microbial Contamination of Device (2303)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 04/14/2021
Event Type  malfunction  
Manufacturer Narrative
A device evaluation is anticipated, but has not yet begun.Upon completion of the investigation, a supplemental report will be filed.
 
Event Description
It was reported that prior to use with bd bbl¿ trypticase¿ soy agar with 5% sheep blood (tsa ii) fungal contamination was discovered on plate.The following information was provided by the initial reporter: customer reporting fungal contamination on 221239 plates lot 1042195.
 
Manufacturer Narrative
H.6.Investigation: during manufacturing of material 221239, media is formulated and sent through a high temperature short time sterilizer to remove bioburden.The petri dishes are subjected to uv radiation to decrease bioburden.The petri dishes are filled in a positive pressure hepa filtered environment.The filled plates are cooled and immediately wrapped into sleeves to decrease the introduction of microbes.Sleeves are then packaged into cartons and then transferred to a refrigerated truck (2 to 8 degrees c) for shipment to the distributor.Bd distributors are provided with the storage guidelines for the shipping and handling of bd media of 2 to 8 degrees c in a dark place.The batch history record review for batch 1042195 was satisfactory at time of release per internal procedures.The release testing that is performed on this product does include bioburden testing.A sample of plates are incubated at 25 degrees c and at 35 degrees c for approximately 72 hours.All bioburden testing performed on this batch was satisfactory per bd internal procedures.Affected product does not have any sterility claims; the product is tested for bioburden prior to release to ensure that it conforms to product specifications.However, this does not ensure that the end-user will not receive a contaminated plate.The complaint history was reviewed, and no other complaints have been taken on batch 1042195.Retention samples from batch 1042195 were not available for inspection.No return samples or photos were received for investigation.This complaint cannot be confirmed.Bd will continue to trend complaints for contamination.H3 other text : see h.10.
 
Event Description
It was reported that prior to use with bd bbl¿ trypticase¿ soy agar with 5% sheep blood (tsa ii) fungal contamination was discovered on plate.The following information was provided by the initial reporter: customer reporting fungal contamination on 221239 plates lot 1042195.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BD BBL TRYPTICASE SOY AGAR WITH 5% SHEEP BLOOD (TSA II)
Type of Device
CULTURE MEDIA, NON-SELECTIVE AND NON-DIFFERENTIAL
Manufacturer (Section D)
BECTON, DICKINSON & CO. (SPARKS)
7 loveton circle
sparks MD 21152
MDR Report Key11780749
MDR Text Key278183956
Report Number1119779-2021-00768
Device Sequence Number1
Product Code JSG
UDI-Device Identifier10382902212390
UDI-Public10382902212390
Combination Product (y/n)N
PMA/PMN Number
NA
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type other,user facility
Type of Report Initial,Followup
Report Date 10/07/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Other
Device Expiration Date06/02/2021
Device Model Number221239
Device Catalogue Number221239
Device Lot Number1042195
Was Device Available for Evaluation? No
Initial Date Manufacturer Received 04/14/2021
Initial Date FDA Received05/05/2021
Supplement Dates Manufacturer Received10/07/2021
Supplement Dates FDA Received10/26/2021
Is This a Reprocessed and Reused Single-Use Device? No