Catalog Number OL-XS25453M
Device Problem Material Deformation (2976)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 03/22/2021
Event Type  malfunction  
Manufacturer Narrative
Expiration date - unknown due to unknown lot number.Implanted date: device was not implanted.Explanted date: device was not explanted.Device manufacturer date - unknown due to unknown lot number.The actual device was not returned; therefore, an evaluation of the actual device was unable to be conducted.However, the user facility provided a picture.From the picture, the actual device seemed to have been inserted in the holder.It was impossible to confirm the state of the distal tip section.The wire clip was found attached to the holder.Reproductive testing was performed, referring to the state of the actual sample in the provided picture, about 50 mm from the distal end of a guidewire sample was pinched firmly, and then pulled from the holder, while the wire clip was still attached to the holder.As a result, the urethane coating of distal 50 mm was peeled off.Regarding the involved product code/november 2020 production lot (0yk), review of the manufacturing record and product-release judgement record confirmed no anomaly recorded in them.It is likely that the urethane coating was peeled off 50 mm from the distal end due to an excessive tensile load having been applied to the actual sample during removal from the holder.In addition, a reproductive test showed that there was a possibility that a tensile load could have been applied to the guidewire when the guidewire was pulled from the holder while the wire clip was attached to the holder.However, with no device return the exact cause of the reported event cannot be definitively determined based on the available information.(b)(4).
 
Event Description
The user facility reported that pre-treatment, when the customer looked at a set of single use guidewire, they found that the coating was damaged about 5cm.They did not use the wire.The procedure outcome was not reported.The patient was not harmed.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SINGLE USE GUIDWIRE
Type of Device
ENDOSCOPIC GUIDEWIRE, GASTROENTEROLOGY-UROLOGY
Manufacturer (Section D)
TERUMO CORPORATION, ASHITAKA
150 maimaigi-cho
fujinomiya city, 418
JA  418
Manufacturer (Section G)
TERUMO CORPORATION, ASHITAKA
reg. no. 9681834
150 maimaigi-cho
fujinomiya city, 418
JA   418
Manufacturer Contact
mary o'neill
reg. no. 2243441
950 elkton blvd
elkton, MD 21921
8002837866
MDR Report Key11811039
MDR Text Key264819636
Report Number9681834-2021-00052
Device Sequence Number1
Product Code OCY
UDI-Device Identifier04953170282782
UDI-Public04953170282782
Combination Product (y/n)N
Reporter Country CodeIN
PMA/PMN Number
K091417
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation Other
Type of Report Initial
Report Date 05/12/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue NumberOL-XS25453M
Was Device Available for Evaluation? No
Initial Date Manufacturer Received 04/13/2021
Initial Date FDA Received05/12/2021
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-