• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: WRIGHTS LANE SYNTHES USA PRODUCTS LLC DHS/DCS ONE-STEP LAG SCR 12.7 THRD/85-S; DEVICE, FIXATION, PROXIMAL FEMORAL, IMPLANT

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

WRIGHTS LANE SYNTHES USA PRODUCTS LLC DHS/DCS ONE-STEP LAG SCR 12.7 THRD/85-S; DEVICE, FIXATION, PROXIMAL FEMORAL, IMPLANT Back to Search Results
Model Number 280.285S
Device Problem Break (1069)
Patient Problem Appropriate Clinical Signs, Symptoms, Conditions Term / Code Not Available (4581)
Event Date 09/21/2018
Event Type  Injury  
Manufacturer Narrative
Additional product code: ktt.Complainant part is not expected to be returned for manufacturer review/investigation.(b)(4).Without a lot number the device history records review could not be completed.Product was not returned.Based on the information available, it has been determined that no corrective and/or preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event Description
It was reported that on (b)(6) 2018 , the patient had wi fracture of her intertrochanteric hip area and underwent an open reduction internal fixation surgery.Procedure was completed successfully.On or about (b)(6) 2020, two years following her hip procedure, she was returning home and inside of her garage her hip gave out.Patient then saw her surgeon to describe the issue to him and x-rays were completed which revealed that the screws had all broken and the plate connecting the hip had pulled away from her femur with fracturing.The patient immediately went into another surgery to rectify the situation.It was detailed that all the screws that were inserted had failed over the two year period since her initial surgery.Patient underwent revision surgery for the removal of hardware and the femoral fracture was re-plated utilizing screws from another manufacturer.This report is for one (1) dhs/dcs one-step lag screw 12.7mm thread/85mm-sterile.This is report 1 of 6 for complaint (b)(4).
 
Manufacturer Narrative
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.H6 - codes updated to imdrf codes.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Manufacturer Narrative
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If the information is unknown, not available or does not apply, the section/field of the form is left blank.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event Description
The patient was revised on (b)(6) 2020 to remove the broken screw heads.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
DHS/DCS ONE-STEP LAG SCR 12.7 THRD/85-S
Type of Device
DEVICE, FIXATION, PROXIMAL FEMORAL, IMPLANT
Manufacturer (Section D)
WRIGHTS LANE SYNTHES USA PRODUCTS LLC
1302 wrights lane east
west chester PA 19380
MDR Report Key11838246
MDR Text Key262154043
Report Number2939274-2021-02391
Device Sequence Number1
Product Code JDO
UDI-Device Identifier10886982175144
UDI-Public(01)10886982175144
Combination Product (y/n)N
PMA/PMN Number
K964259
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,other
Type of Report Initial,Followup,Followup,Followup
Report Date 04/20/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator No Information
Device Model Number280.285S
Device Catalogue Number280.285S
Was Device Available for Evaluation? No
Initial Date Manufacturer Received 04/20/2021
Initial Date FDA Received05/17/2021
Supplement Dates Manufacturer Received04/20/2021
06/09/2021
08/25/2021
Supplement Dates FDA Received05/18/2021
06/09/2021
09/22/2021
Patient Sequence Number1
Treatment
CORTSCR Ø4.5 SELF-TAP L38 SST; CORTSCR Ø4.5 SELF-TAP L38 SST; CORTSCR Ø4.5 SELF-TAP L38 SST; UNK - PLATES; UNK - SCREWS: TRAUMA
Patient Outcome(s) Required Intervention;
Patient Age57 YR
-
-