Catalog Number 2C1063KP
Device Problem Air/Gas in Device (4062)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 07/07/2021
Event Type  malfunction  
Manufacturer Narrative
(b)(4).The device has been received and the evaluation is in progress.Should additional relevant information become available, a supplemental report will be submitted.
 
Event Description
It was reported that there was an air bubble approximately 5cm in length in the peripherally inserted central catheter (picc) line attached to a large volume infusor.This occurred during patient infusion.The device had been filled with cefepime 6000mg in sodium chloride 0.9%.There was no report of patient injury or medical intervention associated with this event.No additional information is available.
 
Manufacturer Narrative
Additional information was added to h3, h4, and h6.H4: the device was manufactured from february 24, 2021 - february 25, 2021.H10: the device was received for evaluation.Visual inspection did not identify any abnormalities that could have contributed to the reported condition.When the luer cap was removed, evidence of continuous flow of fluid was observed coming out of the line.A functional flow rate test was performed and found to be within the product specification range.The reported condition was not verified.A batch review was conducted and there were no deviations found related to this reported condition during the manufacture of this lot.Should additional relevant information become available, a supplemental report will be submitted.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
INFUSOR
Type of Device
PUMP, INFUSION, ELASTOMERIC
Manufacturer (Section D)
BAXTER HEALTHCARE CORPORATION
deerfield IL
MDR Report Key12275035
MDR Text Key264984938
Report Number1416980-2021-04783
Device Sequence Number1
Product Code MEB
UDI-Device Identifier00085412081366
UDI-Public(01)00085412081366
Combination Product (y/n)Y
PMA/PMN Number
K071222
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Type of Report Initial,Followup
Report Date 09/02/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Lay User/Patient
Device Catalogue Number2C1063KP
Device Lot Number21B044
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer07/26/2021
Initial Date Manufacturer Received 07/08/2021
Initial Date FDA Received08/04/2021
Supplement Dates Manufacturer Received08/30/2021
Supplement Dates FDA Received09/02/2021
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Treatment
CEFEPIME 6000MG; PERIPHERALLY INSERTED CENTRAL CATHETER; SODIUM CHLORIDE 0.9%; CEFEPIME 6000MG; PERIPHERALLY INSERTED CENTRAL CATHETER; SODIUM CHLORIDE 0.9%
-
-