• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ST. JUDE MEDICAL PUERTO RICO, INC. SJM REGENT HEART VALVE; HEART-VALVE, MECHANICAL

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ST. JUDE MEDICAL PUERTO RICO, INC. SJM REGENT HEART VALVE; HEART-VALVE, MECHANICAL Back to Search Results
Model Number 29AGN-751
Device Problems Perivalvular Leak (1457); Off-Label Use (1494)
Patient Problems Hemolysis (1886); Pneumonia (2011); Stenosis (2263); Heart Failure/Congestive Heart Failure (4446); Mitral Valve Insufficiency/ Regurgitation (4451)
Event Type  Injury  
Manufacturer Narrative
The results/method and conclusion codes along with investigation results will be provided in the final report.
 
Event Description
The article, "reoperation for mitral paravalvular leak 9 years after the mitral valve replacement", was reviewed.It was reported that a (b)(6) male patient was implanted with a 29 mm sjm regent heart valve in the mitral position 9 years ago due to infectious endocarditis.Coronary artery bypass grafting (cabg) was performed concomitantly.A few years later from the initial implant surgery, paravalvular leakage (pvl) started to be confirmed.However, the degree of leakage was subtle at that time so the patient was closely monitored in outpatient clinic.A few more years later, the patient was hospitalized due to pneumonia and congestive heart failure (chf).After discharge, the patient continued to be treated by medication though recurrence and deterioration of chf was confirmed.The patient was hospitalized again for detail examination.Coronary (graft vessel: lita to lad) was patent though, #4pd was found 90% stenosis.Blood test was t - bilirubin 2.2 mg/dl, hemaglobin 10.4 g/dl and b-type natriuretic peptide (bnp) 765 pg/ml.Pvl was confirmed exacerbated by transthoracic echocardiography (tte) so transesophageal echocardiography( tee) was performed.The area which the regent valve was seated had dehisced from anterior leaflet to lateral side beyond left atrial appendage (laa) and hypermobility of valve seated area was confirmed.Regurgitation flow was confirmed to be circled from anterior side of the left atrium toward septum.The degree of regurgitation was diagnosed as severe.Hemolysis was also confirmed in addition to chf.Based on the observation result above, a redo surgery was scheduled as semi-emergent manner.A redo mitral valve replacement was performed and the 29 mm regent valve was explanted and 27 mm non-abbott valve was implanted instead.Tricuspid valvuloplasty (28 mm competitor's annuloplasty ring), laa closure and cabg (svg to 4pd) were also performed concomitantly.According to intraoperative findings, the regent valve had dehisced two-third circumferentially from anterior side which was as central part toward 8 o'clock to 4 o'clock.The tissue attached to the valve had been fragile though, possible prosthetic valve infection was being denied.No additional information.
 
Manufacturer Narrative
An event of paravalvular leakage, regurgitation and hemolysis were reported.A more comprehensive assessment could not be performed as the device was not returned for analysis.Based on the information received, the cause of the reported incident could not be conclusively determined.Please note that per the instruction for use, artmt100122074 revision a , "the sjm regent¿ mechanical heart valve is a bileaflet valve, designed for supra-annular implantation in the aortic position.".
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SJM REGENT HEART VALVE
Type of Device
HEART-VALVE, MECHANICAL
Manufacturer (Section D)
ST. JUDE MEDICAL PUERTO RICO, INC.
p.o. box 998
lot 20 b st.
caguas, puerto rico 00725
MDR Report Key12333872
MDR Text Key266978395
Report Number2648612-2021-00087
Device Sequence Number1
Product Code LWQ
Combination Product (y/n)N
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Type of Report Initial,Followup
Report Date 09/03/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number29AGN-751
Was Device Available for Evaluation? No
Was the Report Sent to FDA? No
Initial Date Manufacturer Received 07/20/2021
Initial Date FDA Received08/17/2021
Supplement Dates Manufacturer Received09/02/2021
Supplement Dates FDA Received09/03/2021
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Outcome(s) Hospitalization; Required Intervention;
Patient Age60 YR
Patient Weight85
-
-