C.R. BARD, INC. (BASD) -3006260740 TITANIUM LOW-PROFILE IMPLANTABLE PORT, GROSHONG SINGLE-LUMEN, 8F; PORT & CATHETER, IMPLANTED, SUBCUTANEOUS, INTRAVASCULAR
|
Back to Search Results |
|
Model Number 0606150 |
Device Problems
Difficult to Flush (1251); Reflux within Device (1522)
|
Patient Problem
No Clinical Signs, Symptoms or Conditions (4582)
|
Event Date 08/05/2021 |
Event Type
malfunction
|
Manufacturer Narrative
|
As the lot number for the device was provided, a review of the device history records will be performed.The sample was not returned to the manufacturer for inspection/evaluation.Therefore, the investigation of the reported event is inconclusive.Based upon the available information, the definitive root cause for this event is unknown.The instructions for use (ifu) is adequate for the reported device/patient code(s) and provides general instructions for use, as well as warnings, precautions and potential complications associated with the device.Upon receipt of new or additional information, a follow-up report will be submitted as applicable.(expiry date: 04/2025).Device not returned.
|
|
Event Description
|
It was reported that during a port placement procedure, the unusable reflux of the products was allegedly injected into the chamber.There was no reported patient injury.
|
|
Event Description
|
It was reported that during a port placement procedure, the device allegedly had a a reflux of liquid.It was further reported that the device was allegedly difficult to flush.There was no reported patient injury.
|
|
Manufacturer Narrative
|
H10: manufacturing review: the device history records have been reviewed and this lot met all release criteria.There was nothing found to indicate there was a manufacturing related cause for this event.Investigation summary: the physical device was not returned for evaluation.No photos were provided for review.Therefore, the investigation is inconclusive for the reported blood backflow and difficult to flush issues, as no objective evidence was provided for review.The definitive root cause could not be determined based upon available information.Labeling review: a review of product labeling documentation (e.G., procedural instructions, indications, warnings, precautions, cautions, possible complications, contraindications, nursing guide, and unit label) did not find any product labeling inadequacy.H11:section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.H3 other text : device not returned.
|
|
Manufacturer Narrative
|
H10: manufacturing review: the device history records have been reviewed and this lot met all release criteria.There was nothing found to indicate there was a manufacturing related cause for this event.Investigation summary: one titanium low profile implantable port was returned for evaluation.Functional and gross visual evaluations were performed.An in-house syringe was attached to a safety infusion set and the non-coring needle was inserted into the port septum.Upon application of pressure on the syringe plunger during the attempt to infuse, resistance was met.Further application of pressure expelled blood residue from the port stem.Post expulsion, infusion and aspiration were both successful.However, the investigation is inconclusive for the reported blood backflow and difficult to flush issues, as the exact circumstances at the time of the reported event are unknown, and the reported event could not be reproduced in the lab.The definitive root cause could not be determined based upon available information.Labeling review: a review of product labeling documentation (e.G., procedural instructions, indications, warnings, precautions, cautions, possible complications, contraindications, nursing guide, and unit label) did not find any product labeling inadequacy.H11:section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
|
Event Description
|
It was reported that during a port placement procedure, the device allegedly had a a reflux of liquid.It was further reported that the device was allegedly difficult to flush.There was no reported patient injury.
|
|