Model Number 5392
Device Problems Display or Visual Feedback Problem (1184); Material Integrity Problem (2978)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 09/03/2021
Event Type  malfunction  
Manufacturer Narrative
Product analysis: analysis was able to confirm the customer comment that an error occurred on the epg.It was further noted that the display wire insulation was pinched (wire insulation exposed), battery wire was pinched (wire insulation not compromised), encoder assembly was contaminated, encoder knob was contaminated, output connector assembly was broken, keypad was dented and scratched, hanger assembly was missing, hanger screw and hanger o-ring were missing, also updated battery drawer shorting bar was needed.All found defective parts were replaced and all other identified issues were resolved.The epg then passed all final functional tests if information is provided in the future, a supplemental report will be issued.
 
Event Description
It was reported that the external pulse generator (epg) which was received into service for repair subsequently tested out-of-specification during manufacturer's analysis.There was no patient involvement.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
DUAL CHAMBER TEMPORARY PACEMAKER
Type of Device
PULSE-GENERATOR, PACEMAKER, EXTERNAL
Manufacturer (Section D)
MEDTRONIC, INC.
8200 coral sea street ne
mounds view MN 55112
Manufacturer (Section G)
MEDTRONIC, INC.
8200 coral sea street ne
mounds view MN 55112
Manufacturer Contact
paula bixby
8200 coral sea st ne
mounds view, MN 55112
7635055378
MDR Report Key12581611
MDR Text Key274927195
Report Number2182208-2021-03952
Device Sequence Number1
Product Code DTE
UDI-Device Identifier00643169230859
UDI-Public00643169230859
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K150246
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative
Reporter Occupation Non-Healthcare Professional
Type of Report Initial
Report Date 10/06/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Other
Device Model Number5392
Device Catalogue Number5392
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/08/2021
Initial Date Manufacturer Received 09/23/2021
Initial Date FDA Received10/06/2021
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured05/23/2014
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
-
-