• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: UNOMEDICAL S.R.O. L3C1950 - UNO OR/SECUREMENT; TAPE AND BANDAGE, ADHESIVE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

UNOMEDICAL S.R.O. L3C1950 - UNO OR/SECUREMENT; TAPE AND BANDAGE, ADHESIVE Back to Search Results
Model Number 680M
Device Problem Device Contaminated During Manufacture or Shipping (2969)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Type  malfunction  
Manufacturer Narrative
Initial reporter complainant contact information: (b)(6).Based on the available information, this event is deemed to be a reportable malfunction.To date no additional information has been received.Should additional information become available, a follow-up report will be submitted.Fda registration number reporting site: (b)(4).Manufacturing site: (b)(4).
 
Event Description
It was reported "that there is a foreign matter at the inside of the package." photos depicting the reported complaint issue were provided by the complainant.The product was not used.
 
Event Description
To date no additional patient or event details have been received.
 
Manufacturer Narrative
This complaint has been evaluated as a type 2 case.The identified malfunction code sec-pmc07.09 foreign matter (e.G.Hairs, insects) within primary pack (sterile products-niko-fix, epi-fix, easi v, drain-fix, central gard only) is associated with golden investigation (b)(4).Photographs have been received for this complaint, which were evaluated in accordance with (b)(4).It is visible foreign body/ marks inside primary pack.It was received 1pc of sample to similar complaint (b)(4) for the same lot 0k01974.Sample was evaluated, issue was confirmed.Batch record review was conducted resulting in following: uno drain fix s (25/200)ster int in question was manufactured under sap material id: 1301277, ref: 680m and manufacturing lot # 0k01974.The securement were produced, visually checked under subassembly lots 0j00258 from 17th of september 2020 till 29nd of september 2020 and 0j04006 from 29st of september 2020 till 16th of october 2020 on manual operation station c080 and then packed into the peelpacks (pouch) under lot 0k01974 from 19th of october 2020 till 21st of october 2020 on center c2 on machine p013, with total lot amount (b)(4).Lot # 0k01974 was sterilized under certificate 2173 ¿ 14751a and released based on the review of results of sterilization provided by sterilization company steris.All the results were within specification and products were released in compliance with (b)(4).Review of the dhr showed that all relevant tests required during the manufacturing process and final product release had been fulfilled and met the requirements.The process parameters were adjusted within the validated window.The packaging of products was run according to the process instruction pi41-013 for packing of sterile securements products and recorded in br41-013.During production of this lot, pouches were visually inspected using: tm-296 ¿ on beginning of order is checked 1 sample from each cavity.During in-process control is performed 100% visual inspection.No nonconformance has been registered during the manufacturing process of the affected lot and of the mention malfunction code¿ sec-pmc07.09 foreign matter (e.G.Hairs, insects) within primary pack (sterile products-niko-fix, epi-fix, easi v, drain-fix, central gard only)¿.Three similar complaints were registered on mentioned malfunction code: (b)(4).It was received 1pc of sample for similar complaint (b)(4), which was investigated.During production of lot 0k01974 was used packing raw material: packing foil sap code (b)(4) with batch numbers 0001642562 and 0001623177.Incoming inspection for material 1725214 with batch numbers 0001642562 and 0001623177 were in accordance with material specification mt58-005 v.4.0.Materials were released based on control of certificates.Certificates were reviewed and they were in accordance with mt58-005 v.4.0 this complaint is within scope of investigation event (b)(4)¿ foreign body.The most probable root cause resulted from the investigation ir21-007-mic (ver.1) were identified: rc1: not barrier between the chain and the film rc2: the instruction does not contain the cleaning periodicity rc3: inattention of the operators investigation report (b)(4) foreign body- securements (uno drain fix s 25/200 ster int) was approved at crb-c5/qa/wh-mic held on 26-apr-2021 by meeting attendants.Corrective and preventive actions are covered within capa tw1454179 foreign body- securements opened on 04th of may 2021.Capa is in effectiveness check state and they were determined capa actions: ca1: implementation of chain covering at the place next to film feeding.Ca2: including c5 technicians into g805121.Ca3: update tm-296/tm-296sk.Ec1: production of 3 batches after implementation of suggested solution.Ec2: review of complaints 6 month after implementation.All corrective actions were implemented.The chain covering was installed at the place next to film feeding from (b)(6) 2021.Lot 0k01974 was manufactured before implementation of corrective actions.The investigation of issue will be closed.This issue will be monitored through the post market product monitoring review process.Based on the available information, this event is deemed to be a reportable malfunction.To date no additional information has been received.Should additional information become available, a follow-up report will be submitted.Fda registration number: reporting site: 1049092, manufacturing site:3005778470.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
L3C1950 - UNO OR/SECUREMENT
Type of Device
TAPE AND BANDAGE, ADHESIVE
Manufacturer (Section D)
UNOMEDICAL S.R.O.
priemyselny park 3,
michalovce 07101
LO  07101
Manufacturer (Section G)
UNOMEDICAL S.R.O.
priemyselny park 3,
michalovce 07101
LO   07101
Manufacturer Contact
pamela meadows
7815 national service road
suite 600
greensboro, NC 
3365424679
MDR Report Key12608692
MDR Text Key276463106
Report Number3005778470-2021-00483
Device Sequence Number1
Product Code KGX
Combination Product (y/n)N
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Distributor
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 10/06/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Other
Device Expiration Date09/01/2023
Device Model Number680M
Device Lot Number0K01974
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Was the Report Sent to FDA? Yes
Initial Date Manufacturer Received 10/06/2021
Initial Date FDA Received10/11/2021
Supplement Dates Manufacturer Received11/22/2021
Supplement Dates FDA Received12/23/2021
Was Device Evaluated by Manufacturer? No
Date Device Manufactured10/13/2020
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Unknown
Patient Sequence Number1
-
-