Catalog Number 2C4711K
Device Problems Break (1069); Device Dislodged or Dislocated (2923); No Flow (2991)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 09/21/2021
Event Type  malfunction  
Manufacturer Narrative
Initial reporter postal code:(b)(6).Should additional relevant information become available, a supplemental report will be submitted.
 
Event Description
It was reported that a small volume folfusor would not flow during patient infusion.It was further reported the balloon stem (stressmember) "appeared to be snapped and balloon alignment in the device seem to be off center".There was no damage to the packaging.The device contained fluorouracil 4800mg in sodium chloride 0.9%.There was no patient injury or medical intervention associated with this event.No additional information is available.
 
Manufacturer Narrative
H4: device manufacture date: june 14, 2021 - june 15, 2021.H10: the actual device was not available; however, a photograph of the sample was provided for evaluation.Visual inspection was performed on the photograph which displayed fluid inside the bladder.The photograph suggested a no flow condition may have occurred.The photograph also showed a crooked stressmember stem inside the housing of the device.The reported condition was verified.The cause of the condition could not be determined.A batch review was conducted and there were no deviations found related to this reported condition during the manufacture of this lot.Should additional relevant information become available, a supplemental report will be submitted.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
FOLFUSOR
Type of Device
PUMP, INFUSION, ELASTOMERIC
Manufacturer (Section D)
BAXTER HEALTHCARE CORPORATION
deerfield IL
Manufacturer (Section G)
BAXTER HEALTHCARE - IRVINE
17511 armstrong avenue
building 3
irvine CA 92614
Manufacturer Contact
25212 w. illinois route 120
round lake, IL 
2242702068
MDR Report Key12636066
MDR Text Key276568077
Report Number1416980-2021-06267
Device Sequence Number1
Product Code MEB
UDI-Device Identifier00085412082172
UDI-Public(01)00085412082172
Combination Product (y/n)Y
Reporter Country CodeNZ
PMA/PMN Number
NA
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional,Company Representative
Reporter Occupation Pharmacist
Type of Report Initial,Followup
Report Date 11/18/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Other
Device Catalogue Number2C4711K
Device Lot Number21F036
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 09/22/2021
Initial Date FDA Received10/14/2021
Supplement Dates Manufacturer Received11/11/2021
Supplement Dates FDA Received11/18/2021
Was Device Evaluated by Manufacturer? No
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Treatment
FLUOROURACIL; SODIUM CHLORIDE 0.9%
-
-