Model Number 83-1615
Device Problem Chemical Problem (2893)
Patient Problem Insufficient Information (4580)
Event Date 11/04/2021
Event Type  malfunction  
Event Description
Today we mixed a batch of smart set ghv bone cement and the scrub nurse could not push the white pusher into the top of the smartmix cemvac mixing system.When she eventually got it in and mixed the cement it looked looked lumpy instead of smooth.This was not used and we tried again with a new mix.We had the same issue with the white rod in the top of the mixer but the mix looked better.However when we went to use it stayed running and sticky for a longer time than normal (approx 5 minutes) and was noticed that there were small lumps.The surgeon wasn't happy to continue.We then mixed a third batch of cement from a different supplier (cement and mixing system).15 minute surgical delay.Surgery successfully completed.
 
Manufacturer Narrative
Product complaint # (b)(4).No 510k as device is not marketed in the united states under this product code, but the same/similar product is marketed in the us under a different product code.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Manufacturer Narrative
Product complaint # : (b)(4).Investigation summary : no device associated with this report was received for examination.The information received will be retained for potential series investigations if triggered by trend analysis, post market surveillance, or other events within the quality system.Depuy considers the investigation closed.Should additional information be received, the information will be reviewed and the investigation will be re-opened as necessary.Device history lot : a manufacturing record evaluation was performed for the finished device lot number, and no non-conformances related to the malfunction were identified.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SMARTMIX CEMVAC
Type of Device
BONE CEMENT : CEMENT DELIVERY DEVICES
Manufacturer (Section D)
DEPUY CMW - 9610921
cornford rd.
blackpool IN FY4 4 QQ
UK  FY4 4QQ
Manufacturer (Section G)
DEPUY CMW - 9610921
cornford rd
blackpool FY4 4 QQ
UK   FY4 4QQ
Manufacturer Contact
kara ditty-bovard
700 orthopaedic dr.
warsaw, IN 46581-0988
6107428552
MDR Report Key12850112
MDR Text Key285731984
Report Number1818910-2021-25824
Device Sequence Number1
Product Code KIH
UDI-Device Identifier10603295202493
UDI-Public10603295202493
Combination Product (y/n)N
Reporter Country CodeNZ
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional,Company Representative
Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date 11/03/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number83-1615
Device Catalogue Number831615
Device Lot Number21030247
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 11/03/2021
Initial Date FDA Received11/21/2021
Supplement Dates Manufacturer Received02/22/2022
Supplement Dates FDA Received02/23/2022
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured04/19/2021
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Treatment
SMARTMIX CEMVAC; SMARTMIX CEMVAC; SMARTSET GHV GENTAMICIN 40G; SMARTSET GHV GENTAMICIN 40G; SMARTSET GHV GENTAMICIN 40G
Patient SexFemale
-
-