• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: PROCEPT BIOROBOTICS CORPORATION AQUABEAM ROBOTIC SYSTEM; FLUID JET REMOVAL SYSTEM

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

PROCEPT BIOROBOTICS CORPORATION AQUABEAM ROBOTIC SYSTEM; FLUID JET REMOVAL SYSTEM Back to Search Results
Model Number AB2000
Device Problem Display or Visual Feedback Problem (1184)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 11/17/2021
Event Type  malfunction  
Manufacturer Narrative
Additional manufacturer narrative: (b)(4).Root cause of reported event has not yet been established.Investigation by manufacturer is currently in-process.Submission of this report does not constitute an admission that the manufacturer's product caused or contributed to the event.
 
Event Description
A male patient underwent an aquablation procedure for symptomatic benign prostatic hyperplasia (bph).Procept biorobotics corporation became aware that during the aquablation procedure an "e03 - console error" message was generated by the aquabeam robotic system.The error message was unable to be cleared after multiple troubleshooting steps were performed; only one (1) treatment pass was able to be completed.The treating physician resected the remaining prostatic tissue with a loop.There were no adverse health consequences to the patient due to this event.
 
Manufacturer Narrative
H.10 additional manufacturer narrative: the aquabeam console was returned for investigation.Functional testing was able to reproduce the reported "e03 - console error" upon priming at 25% and 50% and an "e02 - console error" at 100% pump power.The e02/e03 erros prevented the system from initializing an aquablation simulation cycle.Additional analysis observed oil droplets on the encoder lens emitter and was identified to be the main cause of the e02/e03 issues.A review of the device history record (dhr) for serial number (b)(6) and the aquabeam console / lot number (b)(6) was performed, which confirmed that there were no nonconformances, failures, discrepancies, or missed steps during the manufacturing process that could be related to the reported event.The review indicated that the system and its associated component met all design and manufacturing specifications when released for distribution.A review of similar complaints confirmed five (5) other similar events reported to procept.Aquabeam robotic system user manual, um0101-00 rev.E, was reviewed and states the following: table 5: system detected error and faults.E02 - console error.Release foot pedal and click x.If error persists, turn off and turn on console.E03 - console error.Release foot pedal and click x.If error persists, turn off and turn on console.The root cause of the encodercontamination have been determined to be due manufacturing related issues by a third party supplier.A corrective action and preventive action has been initiated by procept to determine appropriate actions.Submission of this report does not constitute an admission that the manufacturer's product caused or contributed to the event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AQUABEAM ROBOTIC SYSTEM
Type of Device
FLUID JET REMOVAL SYSTEM
Manufacturer (Section D)
PROCEPT BIOROBOTICS CORPORATION
900 island drive
suite 101
redwood city CA 94065 1494
Manufacturer (Section G)
PROCEPT BIOROBOTICS CORPORATION
900 island drive
suite 101
redwood city CA 94065 1494
Manufacturer Contact
doria esquivel
900 island drive
suite 101
redwood city, CA 94065-1494
MDR Report Key12981017
MDR Text Key285339788
Report Number3012977056-2021-00102
Device Sequence Number1
Product Code PZP
UDI-Device IdentifierB614AB20001
UDI-Public+B614AB20001/16D20211014C
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
DEN170024
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 03/28/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberAB2000
Device Catalogue NumberAB2000
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer11/19/2021
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 11/18/2021
Initial Date FDA Received12/10/2021
Supplement Dates Manufacturer Received03/10/2022
Supplement Dates FDA Received03/29/2022
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured10/14/2021
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient SexMale
-
-