Model Number ERIS-CF25
Device Problem Component Missing (2306)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Type  malfunction  
Event Description
As reported, the resectoscope is missing the ceramic tip.The issue found during an unknown event.There is no patient involvement /harm or injury associated on this reported event.No user injury reported.
 
Manufacturer Narrative
The subject device was not returned for evaluation.The device photo provided shows that the ceramic tip of one sheath was completely missing.No other physical damage was observed from the photo.Multiple attempts has been made to gather additional information, however, were unsuccessful, no response received from the customer.Investigation is ongoing.This report will be supplemented accordingly following investigation.
 
Manufacturer Narrative
This report is being supplemented to provide additional information based on the legal manufacturer's final investigation.H4 - multiple attempts were made to identify the serial number but were unsuccessful.Therefore, device manufacture date is unknown.The dhr was unable to be reviewed for this device since the serial number was not provided.However, olympus only releases products to market that meet all manufacturing specifications and final product release criteria.There has since been a design change, to remediate tip fracture, a design change in material and geometries of the tips has been implemented.The new tip material has been successfully validated for production release.Since the serial number of the reported device is unknown, it is unknown if the device has an old or newly designed ceramic tip.Based on the results of the investigation, the cause of the missing ceramic tip could not be determined at this time as the device was not returned for evaluation.The following information is stated in the instructions for use: " do not use an instrument that fails to meet the criteria stated in the labeling or that has been damaged.Damage may result in the loss of the entire ceramic tip or fragments of the ceramic tip.If there is evidence of charring, burn spots, chips or cracks in the ceramic tip or surrounding area, do not use.Warning: always keep sheaths parallel to one another when assembling and disassembling.If the inner sheath is inserted or removed at an angle to the outer sheath, the lateral force applied to the inner sheath may crack, loosen, break, or otherwise damage the sheath¿s insulated distal tip.A broken tip, or fragments of a damaged tip, can potentially pass through the outer sheath and into the patient.If drag or resistance is encountered during assembly or disassembly, stop, align working element and sheath parallel to one another before proceeding." olympus will continue to monitor field performance for this device.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ROTATING CF RESECTOSCOPE INNER SHEATH
Type of Device
ROTATING CF RESECTOSCOPE INNER SHEATH
Manufacturer (Section D)
GYRUS ACMI, INC
136 turnpike road
southborough MA 01772
Manufacturer Contact
kenneth pittman
93 north pleasant st.
norwalk, OH 44857
9013785969
MDR Report Key12981376
MDR Text Key290076834
Report Number1519132-2021-00022
Device Sequence Number1
Product Code FAS
UDI-Device Identifier00821925003484
UDI-Public00821925003484
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K890328
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type User Facility,Company Representative
Reporter Occupation Nurse
Type of Report Initial,Followup
Report Date 01/03/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberERIS-CF25
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Initial Date Manufacturer Received 11/11/2021
Initial Date FDA Received12/10/2021
Supplement Dates Manufacturer Received12/15/2021
Supplement Dates FDA Received01/03/2022
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
-
-