MAUDE Adverse Event Report: STRYKER ORTHOPAEDICS-MAHWAH TRIATHLON PKR INSERT X3 #5 LM/RL -8MM; PROSTHESIS, KNEE, FEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, METAL/POLYMER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

STRYKER ORTHOPAEDICS-MAHWAH TRIATHLON PKR INSERT X3 #5 LM/RL -8MM; PROSTHESIS, KNEE, FEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, METAL/POLYMER Back to Search Results
Model Number 5630-G-508
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Arthritis (1723); Pain (1994)
Event Date 09/13/2021
Event Type  Injury  
Manufacturer Narrative
It was noted that the device is not available for evaluation.Should additional information become available, it will be provided in a supplemental report upon completion of the investigation.Review of the device history records indicate devices were manufactured and accepted into final stock with no relevant reported discrepancies.There have been no other similar events for the lot referenced.The following devices were also listed in this report: triathlon pkr femur #5 lm/rl; cat#5610-f-501 ; lot#fytk triathlon pkr baseplate #5 lm/rl; cat#5620-b-501 ; lot#jrela it cannot be determined which, if any of these devices may have caused or contributed to the patient's experience.H3 other text : device not returned to the manufacturer.
 
Event Description
This is a study subject in the triathlon pkr outcomes study.The site attributed this to a sports injury.The subject had his original pkr surgery on (b)(6) 2016 for the medial compartment.On (b)(6), 2017, an adverse event was reported noting progression of osteoarthritis on the lateral compartment and patella-femoral area treated with several injections of supartz and steroids.The event was considered resolved as of (b)(6) 2017.On (b)(6) 2018, it was reported that the subject sustained a trauma and experienced a lateral meniscus tear.A plm and chondroplasty was performed via arthroscopy on (b)(6) 2018 and the event was considered resolved.At this time, it was observed that there were grade 2-3 changes in patella-femoral and grade 3-4 changes in lateral compartment.On (b)(6) 2018, it was noted that there was progression of the arthritic degeneration in the lateral compartment and the subject started complaining about more pain.It was decided to convert the medial triathlon pkr to a total knee.
 
Manufacturer Narrative
Corrected data - explant date reported event an event regarding patient factors involving a triathlon insert was reported.The event was confirmed through clinician review of the provided medical records.Method & results product evaluation and results: material analysis, visual, functional and dimensional inspections could not be performed as the device was not returned.Clinician review: a review of the provided medical records by a clinical consultant stated the following comment: confirmation: a revision surgery (conversion from a medial unicompartmental knee to a total knee) can be confirmed.A reported arthroscopy with partial lateral meniscectomy was reported but not confirmed.A chondroplasty was not confirmed.Progression of lateral compartment arthritis and injection therapy was confirmed.Root cause: the root cause of the revision surgery was progression/development of lateral compartment arthritis and failure of conservative measures/injection therapy.The root cause of the lateral compartmental arthritis cannot be confirmed but may in part to a related to a reported trauma and lateral meniscectomy/chondroplasty and/or slight over correction.Device history review: all devices were manufactured and accepted into final stock with no relevant reported discrepancies.Complaint history review: there have been no other similar events for the reported lot.Conclusion: a review of the provided medical records by a clinical consultant stated the following comment: confirmation: a revision surgery (conversion from a medial unicompartmental knee to a total knee) can be confirmed.A reported arthroscopy with partial lateral meniscectomy was reported but not confirmed.A chondroplasty was not confirmed.Progression of lateral compartment arthritis and injection therapy was confirmed.Root cause: the root cause of the revision surgery was progression/development of lateral compartment arthritis and failure of conservative measures/injection therapy.The root cause of the lateral compartmental arthritis cannot be confirmed but may in part to a related to a reported trauma and lateral meniscectomy/chondroplasty and/or slight over correction.No further investigation is required at this time.If additional information becomes available to indicate further evaluation is warranted, this record will be reopened.
 
Event Description
This is a study subject in the triathlon pkr outcomes study.The site attributed this to a sports injury.The subject had his original pkr surgery on (b)(6) 2016 for the medial compartment.On 4/18/2017, an adverse event was reported noting progression of osteoarthritis on the lateral compartment and patella-femoral area treated with several injections of supartz and steroids.The event was considered resolved as of 8/25/2017.On 2/16/2018, it was reported that the subject sustained a trauma and experienced a lateral meniscus tear.A plm and chondroplasty was performed via arthroscopy on (b)(6)2018 and the event was considered resolved.At this time, it was observed that there were grade 2-3 changes in patella-femoral and grade 3-4 changes in lateral compartment.On (b)(6) 2018, it was noted that there was progression of the arthritic degeneration in the lateral compartment and the subject started complaining about more pain.It was decided to convert the medial triathlon pkr to a total knee.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TRIATHLON PKR INSERT X3 #5 LM/RL -8MM
Type of Device
PROSTHESIS, KNEE, FEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, METAL/POLYMER
Manufacturer (Section D)
STRYKER ORTHOPAEDICS-MAHWAH
325 corporate drive
mahwah NJ 07430
Manufacturer (Section G)
STRYKER ORTHOPAEDICS-MAHWAH
325 corporate drive
mahwah NJ 07430
Manufacturer Contact
diana rogers
210 centennial avenue
centennial park, elstree
borehamwood, NJ WD6 3-SJ
UK   WD6 3SJ
2018315000
MDR Report Key13017972
MDR Text Key285621328
Report Number0002249697-2021-02050
Device Sequence Number1
Product Code HRY
UDI-Device Identifier07613327016062
UDI-Public07613327016062
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K071881
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 03/27/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Expiration Date10/30/2020
Device Model Number5630-G-508
Device Catalogue Number5630-G-508
Device Lot NumberNN18VW
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 11/22/2021
Initial Date FDA Received12/16/2021
Supplement Dates Manufacturer Received03/01/2022
Supplement Dates FDA Received03/27/2022
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured11/02/2015
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Required Intervention; Hospitalization;
Patient Age72 YR
Patient SexMale
Patient Weight82 KG
Patient EthnicityNon Hispanic
Patient RaceWhite
-
-