Model Number 16414
Device Problem Incorrect, Inadequate or Imprecise Result or Readings (1535)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 01/19/2022
Event Type  malfunction  
Manufacturer Narrative
Per the fsr, the user facility decided to retire the unit.
 
Event Description
The field service representative (fsr) reported that during preventive maintenance of the device, the temperature value on the cardioplegia monitor was false and fluctuating.There was no patient involvement.
 
Manufacturer Narrative
Updated block: h6 the reported complaint was confirmed.However, the customer decided to retire the unit, therefore no further servicing could be done on the unit nor root cause analysis.If additional information becomes available on this complaint that would alter the facts and/or conclusion, a supplemental report will be filed accordingly.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SARNS 8000 CARDIOPLEGIA MONITOR
Type of Device
COMPUTER, BLOOD-PRESSURE-SARNS 8000 CARDIOPLEGIA MONITOR
Manufacturer (Section D)
TERUMO CARDIOVASCULAR SYSTEMS CORPORATION
6200 jackson road
ann arbor MI 48103
Manufacturer (Section G)
SAME
Manufacturer Contact
douglas patton
6200 jackson road
ann arbor, MI 48103
7346634145
MDR Report Key13564286
MDR Text Key286021198
Report Number1828100-2022-00068
Device Sequence Number1
Product Code DSK
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K960916
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Company Representative
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 05/05/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Other
Device Model Number16414
Device Catalogue Number16414
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? No
Was the Report Sent to FDA? No
Initial Date Manufacturer Received 02/18/2022
Initial Date FDA Received02/18/2022
Supplement Dates Manufacturer Received04/13/2022
Supplement Dates FDA Received05/06/2022
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured05/24/2011
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
-
-