Catalog Number CDS0705-NT
Device Problems Positioning Failure (1158); Failure to Advance (2524)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 02/15/2022
Event Type  malfunction  
Manufacturer Narrative
The device is expected to be returned for evaluation.It has not yet been received.A follow-up report will be submitted with all additional relevant information.
 
Event Description
This is being filed to report the cds could not straighten.It was reported that this was a mitraclip procedure to treat degenerative mitral regurgitation (mr) with a grade of 4.The clip delivery system (cds) was advanced into the left ventricle and then pulled back into the left atrium (la) because it was difficult to approach the target site.M knob was applied however the shaft did not straighten therefore the cds was removed.One clip was implanted, reducing mr to 1.There was no clinically significant delay in the procedure and no adverse patient effects.No additional information was provided.
 
Manufacturer Narrative
The reported failure to advance could not be replicated in a testing environment as it could be related to patient anatomy/procedural operational circumstances.The steerable sleeve functioned as intended as the m should not be straighten.The curves were hold in place and no knob slippage was observed.A review of the lot history record identified no manufacturing nonconformities issued to the reported lots and a review of the complaint history identified no other incident reported from this lot.Based on available information, a cause for the reported failure to advance issue could not be determined.The reported unable to straighten was a normal function of the device.There is no indication of a product issue with respect to manufacture, design or labeling.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
MITRACLIP G4 CLIP DELIVERY SYSTEM
Type of Device
MITRAL VALVE REPAIR DEVICES
Manufacturer (Section D)
ABBOTT VASCULAR
26531 ynez rd.
temecula CA 92591 4628
Manufacturer (Section G)
ABBOTT VASCULAR, REG # 3005070406
3885 bohannon drive
menlo park CA 94025
Manufacturer Contact
lindsey bell
26531 ynez rd.
temecula, CA 92591-4628
9519143996
MDR Report Key13658916
MDR Text Key286495662
Report Number2024168-2022-02175
Device Sequence Number1
Product Code NKM
Combination Product (y/n)N
Reporter Country CodeJA
PMA/PMN Number
P100009
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Health Professional,Company Representative
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 03/29/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date03/24/2022
Device Catalogue NumberCDS0705-NT
Device Lot Number10324R161
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 02/15/2022
Initial Date FDA Received03/03/2022
Supplement Dates Manufacturer Received03/28/2022
Supplement Dates FDA Received03/29/2022
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured03/25/2021
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Treatment
STEERABLE GUIDE CATHETER
-
-