• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: C.R. BARD, INC. (COVINGTON) -1018233 BARD® FLUORO-4¿ SILICONE URETERAL STENT

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

C.R. BARD, INC. (COVINGTON) -1018233 BARD® FLUORO-4¿ SILICONE URETERAL STENT Back to Search Results
Model Number 233724
Device Problem Device Dislodged or Dislocated (2923)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 03/14/2022
Event Type  malfunction  
Event Description
It was reported that customer stated that the stent had encrustation.Also, the patient had surgical site infection and stent dislodgment.Patient asked why to believe the information in the instructions for use (ifu) that did not provide sufficient information about the product and its medical application when they were asked of the complications while using the urethral stent.
 
Manufacturer Narrative
The investigation is still in progress.Once the investigation is complete a supplemental report will be filed.The device was not returned.
 
Manufacturer Narrative
The reported event was inconclusive because no sample was returned.A potential root cause for this failure could be ¿material selection part geometry".It was unknown whether the device had met relevant specifications.The product was used for treatment purposes.It was unknown whether the product had caused the reported failure.The lot number was unknown; therefore, the device history record could not be reviewed.The instructions for use were found adequate and state the following: "indications for use: these stents are indicated to relieve obstruction in a variety of benign, malignant and post-traumatic conditions in the ureter such as stones and/or stone fragments, or other ureteral obstructions such as those associated with ureteral stricture, carcinoma of abdominal organs, retroperitoneal fibrosis or ureteral trauma, or in association with extracorporeal shock wave lithotripsy (eswl).The stent may be placed using endoscopic surgical techniques or percutaneously using standard radiographic technique.Warning: this is a single use device.Do not resterilize any portion of this device.Reuse and/or repackaging may create a risk of patient or user infection, compromise the structural integrity and/or essential material and design characteristics of the device, which may lead to device failure, and/or lead to injury, illness or death of the patient.Contraindications: there are no known contraindications to use.Precautions: 1.For single use only.Do not resterilize.Do not use if package or product is damaged.2.Improper handling technique can seriously weaken the stent.Acute bending or overstressing during placement could result in subsequent separation of the stent at the point of stress after a prolonged indwelling period.3.Exercise care.Tearing of the stent can be caused by sharp instruments.4.Choice of stent size and duration of indwelling time are at the discretion of the physician.All stents may be subject to varying degrees of encrustation when placed in the urinary tract.Periodic checks of the stent by cystoscopic and/or radiographic means are recommended.When, at any time during the indwelling duration, encrustation is of sufficient severity that there is potential for occlusion of the stent or the patient experiences pain or discomfort which the physician determines to be associated with the presence of the stent, or if there is indication of infection in the area of the stent, the stent should be removed and, if the patient¿s condition permits, replaced with a new stent.5.Care should be exercised when removing the stent so as not to cause tearing or fragmentation.6.With any ureteral stent, migration is a possible complication which could require medical intervention for removal.Selection of too short a stent may result in migration.7.Multi-length ureteral stents: formation of knots in multi-length ureteral stents may occur.This may result in injury to the ureter during removal and/or the need for additional surgical intervention.The presence of a knot should be considered if significant resistance is encountered during attempts at removal.Directions for use: (open end) 1.Prior to removing guidewire from hoop, inject sterile water through port to activate lubricious coating.2.Pass the guidewire flexible tip beyond the obstruction to the renal pelvis.Note: tortuosity in the obstructed ureter can often be resolved using the guidewire and open end ureteral catheter in combination.3.Pass the stent over the guidewire through the cystoscope, advancing it into the ureter with the push catheter under direct vision.Assistant holds the guidewire in position to prevent advancement of the wire into the renal parenchyma.4.Watch for the distal end of the stent at the ureterovesical junction.Stop advancement of the stent at that point.Assistant removes the guidewire as the operator holds the stent in position with the push catheter.The retention coil will form spontaneously.Carefully remove the push catheter from the cystoscope.Preloaded stent with clamp 1.Prior to removing guidewire from hoop, inject sterile water through port to activate lubricious coating.2.Place guidewire into distal (bladder) end of stent.Advance guidewire to the proximal end of the stent.If stiff end of guidewire is used, do not allow guidewire tip to extend past proximal tip of stent.(this will help keep stent in place for insertion.) 3.Place push catheter on guidewire until it abuts distal end of stent.4.Place small white clamp at most distal end of push catheter and clamp securely (see fig.1).This will ensure correct positioning of stent on the push catheter during insertion procedure.5.Insert stent.6.When placement is complete, release clamp by pushing top portion back and remove from push catheter (see fig.2).7.Hold push catheter and remove guidewire.The stent retention loop will 1.Prior to removing guidewire from hoop, inject sterile water through port to activate lubricious coating.2.Pass the guidewire flexible tip beyond the obstruction to the renal pelvis.Note: tortuosity in the obstructed ureter can often be resolved using the guidewire and open end ureteral catheter in combination.3.Pass the stent over the guidewire through the cystoscope, advancing it into the ureter with the push catheter under direct vision.Assistant holds the guidewire in position to prevent advancement of the wire into the renal parenchyma.4.Watch for the distal end of the stent at the ureterovesical junction.Stop advancement of the stent at that point.Assistant removes the guidewire as the operator holds the stent in position with the push catheter.The retention coil will form spontaneously.Carefully remove the push catheter from the cystoscope." the device was not returned.
 
Event Description
It was reported that customer stated that the stent had encrustation.Also, the patient had surgical site infection and stent dislodgment.Patient asked why to believe the information in the instructions for use (ifu) that did not provide sufficient information about the product and its medical application when they were asked of the complications while using the urethral stent.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BARD® FLUORO-4¿ SILICONE URETERAL STENT
Type of Device
URETERAL STENT
Manufacturer (Section D)
C.R. BARD, INC. (COVINGTON) -1018233
8195 industrial blvd
covington 30014
Manufacturer (Section G)
C.R. BARD, INC. (COVINGTON) -1018233
8195 industrial blvd
covington 30014
Manufacturer Contact
yonic anderson
8195 industrial blvd
covington 30014
7707846100
MDR Report Key14051890
MDR Text Key288865532
Report Number1018233-2022-02105
Device Sequence Number1
Product Code FAD
UDI-Device Identifier10801741011716
UDI-Public(01)10801741011716
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K823487
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Other,Study,Company Representative
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 05/31/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number233724
Device Catalogue Number233724
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 03/14/2022
Initial Date FDA Received04/08/2022
Supplement Dates Manufacturer Received05/31/2022
Supplement Dates FDA Received06/03/2022
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Other;
-
-