This report is being submitted in pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by mitek or its employees that the report constitutes an admission that the device, mitek, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.H10 additional narrative: d9, h3, h6: the actual device has been returned and is currently pending evaluation.Once reliability engineering evaluates the device, a supplemental medwatch report will be sent accordingly.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
This report is being submitted in pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by mitek or its employees that the report constitutes an admission that the device, mitek, or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.H10 additional narrative: investigation summary: the product was returned to mitek for evaluation.Mitek then conducted visual inspection and functional test of device received.Upon visual inspection was found wear use in the entire device.The laser etch were slightly faded.It could be observed the upper jaw is loose, the pin jaw to shaft is missing.Via functionality, the functional test cannot be performed, the auto capture jaw is loose, the jaw doesn¿t maintain the grip pressure when its closed due to the pin guide missing.Manufacturing record evaluation is not required as the reported event is not associated with the manufacturing process and/or the potential cause of the defect cannot be associated to manufacturing.According with the visual inspection and the functional test result, this complaint can be confirmed.The possible root cause for the condition of the device could be related to heavily use and procedural variables, such handling of the device or product interaction during procedure.However, it cannot be conclusively affirmed.As per ifu, it is important to inspect the device prior to use to ensure proper mechanical function and do not use if product is damaged.Also, it is necessary to follow the instructions to cleaning and sterilization process and between uses, lubricate moving parts with the water-solubel lubricant in accordance with the manufacturer¿s instructions.At this point in time, no corrective action is required, and no further action is warranted.However, depuy synthes mitek will continue to track any related complaints within this device family as a means of monitoring the extent with which this complaint is observed in the field.
|