Model Number AL25111-GB
Device Problem Unintended System Motion (1430)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 05/10/2022
Event Type  malfunction  
Manufacturer Narrative
Please note that previous medwatch reports for this product may have been submitted under the registration number (b)(4).Currently, these products are to be handled by arjohuntleigh abs complaint handling establishment and any medwatch reports will be submitted under registration (b)(4).According to an inspection of the parker bath conducted by an arjo representative, the square door lock drive was worn, resulting in the lever slipping in the housing.This defect caused the door to open on its own.The defective part was replaced.The investigation is ongoing and further information will be provided in the next report.
 
Event Description
Arjo was notified of an event involving a parker bath.It was reported that while the patient was bathing, the handle mechanism malfunctioned and the parker door opened fully, flooding the floor.The tub was in the reclining position.The patient did not sustain any injuries.
 
Manufacturer Narrative
Arjo was notified of an event involving a parker bath.It was reported that while the patient was bathing, the handle mechanism malfunctioned and the parker tub door opened fully, flooding the floor.The tub was in the reclining position.The patient did not sustain any injuries.The parker bath inspection performed by an arjo representative after the event revealed that the door locking mechanism mounted within door failed.He indicated that the door lock mechanism was worn, resulting in the lever slipping in the housing.This defect caused the door to open on its own.The arjo representative replaced the defective part.According to arjo representative, the bath in question was used approximately 10 times a day.The parker bath was under arjo service contract.The last maintenance of this bath was conducted by arjo on 14-apr-2022 (one month before the reported event) and did not revealed any door lock mechanism failure.Also, the last annual service conducted by arjo on 07-sep-2021 did not revealed any issues with door lock mechanism.The service history was checked for this device and no door lock mechanism replacement was found.The parker bath is subject to wear and tear, and some actions must be performed when specified to ensure that the product remains within its original manufacturing specification.To avoid malfunction resulting in injury, the user should make sure to conduct regular inspections and follow the recommended maintenance schedule provided within the parker instructions for use (ifu).Actions before every use: "if any part is missing or damaged - do not use the product".In section ¿care and preventive maintenance¿ in the ifu the preventive maintenance schedule is available, which includes the obligation to check door on a weekly basis: ¿open and close the door and check its supports for correct function i.E the door should not drop by itself during closing.Check the lock for proper function.¿ based on the collected information, it can be concluded that the cause of the door lock mechanism failure could be related to the normal wear of the part.The functionality of the bathtub was checked a month before the event and no problems were found, the bath was working properly at the time.Based on the information received from the customer, it is concluded that the door opened by itself while the patient was bathing, which may suggest that the part failed due to wear and tear.In summary, according to the gathered information, the door lock mechanism failed during patient¿s bathing, therefore the device was involved in the reported event.The device was not up to the manufacturer¿s specification at the time of the event.This complaint was decided to be reported to the competent authority in abundance of caution due to the unintentional opening of the bath door while the patient was 's bathing, and the failure was not detected prior to use.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PARKER BATH
Type of Device
BATH, HYDRO-MASSAGE
Manufacturer (Section D)
ARJOHUNTLEIGH POLSKA SP. Z O.O.
ul. ks. piotra wawrzyniaka 2
komorniki PL-62 052
PL  PL-62052
Manufacturer (Section G)
ARJOHUNTLEIGH POLSKA SP. Z O.O.
ul. ks. piotra wawrzyniaka 2
komorniki PL-62 052
PL   PL-62052
Manufacturer Contact
justyna kielbowska
ks. wawrzyniaka 2
komorniki 62-05-2
PL   62-052
883337089
MDR Report Key14615957
MDR Text Key302579427
Report Number3007420694-2022-00089
Device Sequence Number1
Product Code ILJ
Combination Product (y/n)N
Reporter Country CodeUK
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type User Facility,Company Representative
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 06/29/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Other
Device Model NumberAL25111-GB
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? No
Initial Date Manufacturer Received 05/10/2022
Initial Date FDA Received06/07/2022
Supplement Dates Manufacturer Received05/10/2022
Supplement Dates FDA Received06/29/2022
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured12/13/2019
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
Patient Outcome(s) Other;
-
-