Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problem Paralysis (1997)
Event Date 03/17/2021
Event Type  Injury  
Manufacturer Narrative
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.If the information is unknown, not available or does not apply, the section/field of the form is left blank.Report is for an unknown device/unknown lot.Part and lot numbers are unknown; udi number is unknown.Device available for evaluation: complainant part is not expected to be returned for manufacturer review/investigation.Without a lot number the device history records review could not be completed.Product was not returned.Based on the information available, it has been determined that no corrective and/or preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event Description
This report is being filed after the review of the following journal article: toll, b.J.Et al (2021), crossing the cervicothoracic junction in complex pediatric deformity using anterior cervical discectomy and fusion: a case series, child's nervous system, vol.37 (xx), pages 1957¿1964 (usa).The aim of this single-center retrospective cohort study is to evaluate the utility of anterior cervical discectomy and fusion (acdf) in addition to traditional psf crossing the cervicothoracic junction in order to mitigate implant-related complications.Between january 2008 and december 2016, a total of 10 patients (4 boys and 6 girls) with a mean age of 12.8 ± 3.26 years (range 6¿19) were included in the study.All patients were treated surgically with posterior spinal fusion (psf) across the cervicothoracic junction with anterior cervical discectomy and fusion (acdf).Among these patients, 1 case (patient no.9: 12-year-old girl) had a vertical expandable prosthetic titanium rib (veptr) prior to fusion.The average follow-up was 3.4 ± 0.9 years (range 2¿5).The following complications were reported as follows: patient 9: a 12-year-old girl experienced paraplegia due to her severe deformity and underwent posterior spinal fusion (psf) across the cervicothoracic junction with anterior cervical discectomy and fusion (acdf).Following definitive intervention, her neurological symptoms resolved.This report is for an unk - construct: veptr.This is report 1 of 1 for (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
UNK - CONSTRUCTS: VEPTR
Type of Device
PROSTHESIS, RIB REPLACEMENT
Manufacturer (Section D)
SYNTHES GMBH
eimattstrasse 3
oberdorf 4436
SZ  4436
Manufacturer Contact
kate karberg
1302 wright lane east
west chester, PA 19380
3035526892
MDR Report Key15360807
MDR Text Key299303733
Report Number8030965-2022-06394
Device Sequence Number1
Product Code MDI
Combination Product (y/n)N
Reporter Country CodeUS
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Literature,Health Professional
Reporter Occupation Physician
Type of Report Initial
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 08/10/2022
Initial Date FDA Received09/06/2022
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Type of Device Usage Unknown
Patient Sequence Number1
Patient Outcome(s) Other;
Patient Age12 YR
Patient SexFemale
-
-