Catalog Number 05342716001
Device Problems Circuit Failure (1089); Fire (1245); Leak/Splash (1354); Smoking (1585)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 09/06/2022
Event Type  malfunction  
Manufacturer Narrative
Investigation is on-going.A follow-up report will be submitted upon the completion of the investigation.
 
Event Description
During a troubleshooting visit, a field specialist identified that the afm gpio board from a benchmark ultra instrument located at a customer in the united states has signs of corrosion and minor charring.No signs of smoke or flames.No harm or injury alleged.
 
Manufacturer Narrative
Further investigation is needed to determine the root cause(s) of the issue.
 
Manufacturer Narrative
The field service engineer replaced the damaged tubing that caused the fluid migration affecting the gpio board.No further issues were observed.The connectors on the gpio boards are ul94 compliant and are designed to self-extinguish without a separate fuel source.The design of the benchmark ultra instrument limits the chances of the spread of fire due to limited fuel available (plastic) and the fact that it is mounted to metal.The instrument was designed to and has been certified to meet the standards of iec/en 61010-1 which include section 6, protection against electric shock, and section 9, protection against the spread of fire.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BENCHMARK ULTRA STAINER MODULE
Type of Device
SLIDE STAINER, AUTOMATED
Manufacturer (Section D)
VENTANA MEDICAL SYSTEMS INC
1910 e innovation park dr
tucson AZ 85755
Manufacturer Contact
stacie-ann creighton
1910 e. innovation park drive
na
tuscon, AZ 85755
9082537112
MDR Report Key15555370
MDR Text Key305177365
Report Number2028492-2022-00006
Device Sequence Number1
Product Code KPA
UDI-Device Identifier04015630981052
UDI-Public04015630981052
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
510K EXEMPT
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional
Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup,Followup
Report Date 03/02/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number05342716001
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 09/06/2022
Initial Date FDA Received10/06/2022
Supplement Dates Manufacturer Received10/20/2022
01/31/2023
Supplement Dates FDA Received11/18/2022
03/02/2023
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-