• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BECTON, DICKINSON AND COMPANY, BD BIOSCIENCES BD FACS¿ SAMPLE PREP ASSISTANT; SEE H.10.

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BECTON, DICKINSON AND COMPANY, BD BIOSCIENCES BD FACS¿ SAMPLE PREP ASSISTANT; SEE H.10. Back to Search Results
Catalog Number 650686
Device Problem Fluid/Blood Leak (1250)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 10/19/2022
Event Type  malfunction  
Manufacturer Narrative
A device evaluation is anticipated, but has not yet begun.Upon completion of the investigation, a supplemental report will be filed.Common device name: automated pipetting, diluting and specimen processing workstations for flow cytometric analysis.
 
Event Description
It was reported that while using the bd facs¿ sample prep assistant that the instrument is overflowing fluid from the water tower.The following information was provided by the initial reporter: it was reported by the customer over flowing fluid from water tower.
 
Event Description
It was reported that while using the bd facs¿ sample prep assistant that the instrument is overflowing fluid from the water tower.The following information was provided by the initial reporter: it was reported by the customer over flowing fluid - from water tower.
 
Manufacturer Narrative
H.6 investigation summary pr (b)(6) pn: (b)(6) spaiii sn: (b)(6) awareness: 10/19/2022 opened: 10/19/2022.Investigation summary: ¿ scope of issue: the scope of issue is limited to part: (b)(6) spaiii and serial number: (b)(6).¿ problem statement: customer reported: overflowing fluid ¿ from water tower ¿ manufacturing defect trend: there are (b)(4) qns related to the reported issue.Date range (date of incident to 12 months back) from (b)(6) 2021 to date (b)(6) 2022 (rolling 12 months).¿ complaint trend: there are 4 complaints related to the reported complaint.Date range (date of incident to 12 months back) from (b)(6) 2021 to date (b)(6) 2022 (rolling 12 months) o (this complaint).¿ investigation result / analysis: per fse¿s report: replaced filter waste fittings/coupling valves.O tested and verified instrument performance.O no further issues.O sample preparation was not affected.O there was no delay in patient treatment due to any unexpected results.¿ service max review: review of related work order#: (b)(4) install date: (b)(6) 2009.Defective part number: 640520-coupling body valved, 640521-coupling insert valve work order notes: o subject / reported: overflowing fluid ¿ from water tower.O problem description: fluid leak.O cause: overflow caused by clogged coupling valves.O work performed: replaced coupling valves.O solution: replaced coupling valves.O parts replaced: 640520-coupling body valved, 640521-coupling insert valve.¿ returned sample analysis: the complaint sample was not requested to be returned and no photo(s) / picture(s) were provided.¿ manufacturing device history record (dhr) review: review of the dhr for serial number: (b)(6) and pn(b)(6) was reviewed.The instrument met all the manufacturing specifications prior to release.¿ risk analysis: o risk management file part #(b)(4), revision 03 was reviewed.O hazard(s) identified?: yes/no.O hazard id: 3.1.29.O hazard: environment biohazard.O cause: filter/components in fluid path get clogged.O harmful effects: exposure to biohazard.O residual severity: 5.O residual probability: 1.O residual risk index:: 5.¿ root cause: based on the investigation result and fse¿s report the root cause was clogged coupling valves.¿ conclusion: based on the investigation results and the fse¿s report the complaint was confirmed for overflowing fluid.No one was harmed or injured, and no medical diagnosis was performed due to any incorrect results.There was no impact to the patient health or safety.H3 other text : see h.10.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BD FACS¿ SAMPLE PREP ASSISTANT
Type of Device
SEE H.10.
Manufacturer (Section D)
BECTON, DICKINSON AND COMPANY, BD BIOSCIENCES
2350 qume drive
san jose CA 95131
Manufacturer (Section G)
BECTON, DICKINSON AND COMPANY, BD BIOSCIENCES
2350 qume drive
san jose CA 95131
Manufacturer Contact
phillip emmert
9450 south state street
sandy, UT 84070
8015296192
MDR Report Key15655056
MDR Text Key302560680
Report Number2916837-2022-00319
Device Sequence Number1
Product Code PER
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
EXEMPT
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type User Facility
Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date 01/20/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Other
Device Catalogue Number650686
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 10/19/2022
Initial Date FDA Received10/21/2022
Supplement Dates Manufacturer Received01/20/2023
Supplement Dates FDA Received01/25/2023
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured03/22/2012
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-