• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: MEDTRONIC HEART VALVES DIVISION MEDTRONIC HALL PROSTHETIC HEART VALVE; HEART-VALVE, MECHANICAL

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

MEDTRONIC HEART VALVES DIVISION MEDTRONIC HALL PROSTHETIC HEART VALVE; HEART-VALVE, MECHANICAL Back to Search Results
Model Number A7700
Device Problems Degraded (1153); Perivalvular Leak (1457)
Patient Problems Inflammation (1932); Valvular Insufficiency/ Regurgitation (4449)
Event Date 08/01/2022
Event Type  Injury  
Manufacturer Narrative
Citation: saucedo-orozco h.; et al.Bioprosthesis in aortic valve replacement: long-term inflammatory response and functionality.Open heart, 2022 aug;9(2):e002065.Doi: 10.1136/openhrt-2022-002065.Pmid: 35926961.Earliest date of publication used for date of event.Medtronic products referenced: hall mechanical aortic (pma# p790018, product code: lwq); ats 3f aortic valve (pma# p060025, product code: lwr).Earliest approved product used for product code and pma#.No unique device identifier (serial/lot) numbers were provided; without this information it could not be determined whether these observations have been previously reported.Without return of the product no definitive conclusion can be made regarding the clinical observations.Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
 
Event Description
Medtronic received information via literature regarding how inflammatory response may affect bioprosthetic and mechanical aortic replacement valves.All data were collected from a single mexican medical center between january 1995 and january 2020.The study population included 80 patients who were predominantly male with a mean age of 57 years.Multiple manufacturer¿s devices were implanted in the study population; 53 patients were implanted with a mechanical aortic valve, which included medtronic hall valves, and 27 patients were implanted with a bioprosthetic aortic valve, which included medtronic ats 3f valves.No unique device identifier numbers were provided.Among all patients, adverse events included: evidence of inflammation and prosthetic valve dysfunction resulting in anterior paravalvular leaks (pvl).Based on the available information medtronic product may have been associated with the adverse events.No additional adverse patient effects or product performance issues were reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
MEDTRONIC HALL PROSTHETIC HEART VALVE
Type of Device
HEART-VALVE, MECHANICAL
Manufacturer (Section D)
MEDTRONIC HEART VALVES DIVISION
1851 e deere ave
santa ana CA 92705
Manufacturer (Section G)
MEDTRONIC HEART VALVES DIVISION
1851 e deere ave
santa ana CA 92705
Manufacturer Contact
alison sweeney
parkmore business park west
galway 
EI  
091708096
MDR Report Key15721726
MDR Text Key303035381
Report Number2025587-2022-03068
Device Sequence Number1
Product Code LWQ
Combination Product (y/n)N
Reporter Country CodeMX
PMA/PMN Number
P790018
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Foreign,Literature,Health Professional
Reporter Occupation Physician
Type of Report Initial
Report Date 11/03/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Lay User/Patient
Device Model NumberA7700
Device Catalogue NumberA7700
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 10/05/2022
Initial Date FDA Received11/03/2022
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Other;
Patient Age57 YR
Patient SexMale
-
-