Model Number 623-00-36F
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Pain (1994); Unequal Limb Length (4534)
Event Date 09/18/2015
Event Type  Injury  
Event Description
It was reported through the filing of a lawsuit that allegedly on (b)(6), 2014 the patient underwent left total hip arthroplasty.He started experiencing thigh pain, had a positive bone scan with a preop diagnosis of a loose stem.During revision surgery on (b)(6), 2015 the stem was found to be well fixed however the patient had a leg length inequality and his liner and head were exchanged.
 
Manufacturer Narrative
It was noted that the device is not available for evaluation.Should additional information become available, it will be provided in a supplemental report upon completion of the investigation.Review of the device history records indicate devices were manufactured and accepted into final stock with no relevant reported discrepancies.There have been no other similar events for the lot referenced.The following device were also listed in this report: device name#delta v-40 ceramic head 36/0 ; cat#6570-0-136 ; lot#48898302.It cannot be determined which, if any of these device may have caused or contributed to the patient's experience.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TRIDENT 0° X3 INSERT 36MM ID
Type of Device
PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, POROUS UNCEMENTED
Manufacturer (Section D)
STRYKER ORTHOPAEDICS-MAHWAH
325 corporate drive
mahwah NJ 07430
Manufacturer (Section G)
STRYKER ORTHOPAEDICS-MAHWAH
325 corporate drive
mahwah NJ 07430
Manufacturer Contact
arokiya raj
325 corporate drive
mahwah, NJ 07430
2018315000
MDR Report Key15733313
MDR Text Key303058264
Report Number0002249697-2022-01583
Device Sequence Number1
Product Code LPH
UDI-Device Identifier07613327039535
UDI-Public07613327039535
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K033716
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Other
Reporter Occupation Other
Type of Report Initial
Report Date 11/04/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Expiration Date09/30/2019
Device Model Number623-00-36F
Device Catalogue Number623-00-36F
Device Lot NumberMNM13R
Was Device Available for Evaluation? No
Initial Date Manufacturer Received 10/12/2022
Initial Date FDA Received11/04/2022
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured09/05/2014
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Required Intervention; Hospitalization;
Patient Age61 YR
Patient SexMale
-
-