MAUDE Adverse Event Report: TERUMO CORPORATION FUJINOMIYA FACTORY OF TERUMO CORP IMUFLEX BLOOD BAG SYSTEM; IMUFLEX WB-RP BLOOD BAG SYSTEM WITH LR FILTER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

TERUMO CORPORATION FUJINOMIYA FACTORY OF TERUMO CORP IMUFLEX BLOOD BAG SYSTEM; IMUFLEX WB-RP BLOOD BAG SYSTEM WITH LR FILTER Back to Search Results
Catalog Number 1BBWGQ506A2
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 12/02/2022
Event Type  malfunction  
Manufacturer Narrative
Investigation: the set concerned has not yet been provided for evaluation.We therefore conducted investigations based on the provided information.In regard to the production of imuflex, sealed bags are filled with solution and the line is assembled.These bags are sterilized, stacked, and placed into the blister packs.The top film of each blister pack is heat-sealed.For the leukoreduction filter, filter membranes are punched out, laminated, and integrated into soft housing.In order to ensure leukoreduction performance and to prevent filter occlusion in and hemolysis, standards have been set to control particulate removal rates and cationization levels of each filter membrane.The standards of average cationization levels of laminated filter membranes have also been set and controlled.We reviewed the manufacturing record of the lot number in question and confirmed that no anomalies occurred in any process, and the products were manufactured as usual.In addition, we investigated dope material used for the lot number in question and found that the viscosity of pu solution of dope material conformed to the standards.Release testing, which includes measurements of solution concentration and volume and a visual inspection, is performed on the product concerned on a sample basis.We reviewed each testing and inspection record of the production number and confirmed that there were no anomalies in all release testing items.The product conformed to the standards.Regarding the retained sample of the lot number concerned, three sets were visually inspected.There were no abnormalities in their appearances.We used one of the sets to measure the solution volume and used another one of the sets to perform a quantitative test for the composition of the solution in the same manner as the release testing.The measured results conformed to our in-house standards.Root cause: we reviewed the manufacturing record and the testing and inspection record of the lot number concerned; however, we did not find any abnormalities and we were not able to identify the cause of the issue.Leukoreduction failure is commonly caused by the following factors: 1) blood characteristics of donors there is a possibility of leukoreduction failure due to blood characteristics of donors.2) pressure loaded on filter membranes for some reason, where a physical stress on filter membranes is greater than what is expected, trapped white blood cells are pushed out of the filter membranes and may result in leukoreduction failure.For the prevention of leukoreduction failure, the instructions for use (ifu) of the product state: "[caution] do not squeeze or apply pressure on the filter while it is attached to the bag containing the filtered blood", and ¿clamp the blood filled tubing before blood enters the filter¿.We confirmed in some complaints previously reported that the following cases caused leukoreduction failure.- blood was filtered within 30 minutes after blood collection.- the tube below the filter was not clamped before blood flowed into the filter when expelling air.
 
Event Description
The customer reported elevated white blood cell (wbc) content in a filtered whole blood unit.There was not a transfusion recipient or patient involved at the time of the unit processing, therefore no patient information is reasonably known at the time of the event.Donor unit #: (b)(6).Terumo bct is awaiting return of the disposable set for evaluation.
 
Event Description
The customer reported elevated white blood cell (wbc) content in a filtered whole blood unit.There was not a transfusion recipient or patient involved at the time of the unit processing, therefore no patient information is reasonably known at the time of the event.Donor unit #: (b)(6).
 
Manufacturer Narrative
Investigation: we received the leukocyte reduction filter and the primary bag.The filter was rinsed with normal saline.The normal saline flowed through the filter at a fast flow rate of 100 ml/min.We disassembled the rinsed filter to observe the appearance of filter media (membranes).We noticed creases in the filter media; however, the creases were not different from those observed in conforming products.We did not observe aggregates adhered to the filter media.An airtightness test (i.E.Leak test) was performed on the filter in accordance with the following procedures and we confirmed that air leaks were not observed in any locations of the filter.I) the tab sheet covering the outlet side (second side) of the filter is cut out carefully and exposed the outlet side to allow observing the frame sheet (partition) directly.Ii) air is admitted to the filter, which is submerged in water, from the outlet-tube of the filter at a gauge pressure of 39.2 kpa (0.4 kgf/cm2) for approximately 10 seconds to check whether there is any air leakage from the frame sheet (partition).After passing normal saline through the filter, we dyed the filter media with toluidine blue for observation.We noticed that the fifth and six filter media from the inlet side of the filter were dyed dark, that is, white blood cells were accumulated in these dark dyed areas.In regard to the production of imuflex, sealed bags are filled with solution and the line is assembled.These bags are sterilized, stacked, and placed into the blister packs.The top film of each blister pack is heat-sealed.For the leukoreduction filter, filter membranes are punched out, laminated, and integrated into soft housing.In order to ensure leukoreduction performance and to prevent filter occlusion in and hemolysis, standards have been set to control particulate removal rates and cationization levels of each filter membrane.The standards of average cationization levels of laminated filter membranes have also been set and controlled.We reviewed the manufacturing record of the lot number in question and confirmed that no anomalies occurred in any process, and the products were manufactured as usual.In addition, we investigated dope material used for the lot number in question and found that the viscosity of pu solution of dope material conformed to the standards.Release testing, which includes measurements of solution concentration and volume and a visual inspection, is performed on the product concerned on a sample basis.We reviewed each testing and inspection record of the production number and confirmed that there were no anomalies in all release testing items.The product conformed to the standards.Regarding the retained sample of the lot number concerned, three sets were visually inspected.There were no abnormalities in their appearances.We used one of the sets to measure the solution volume and used another one of the sets to perform a quantitative test for the composition of the solution in the same manner as the release testing.The measured results conformed to our in-house standards.Corrected root cause: we did not observe any abnormalities in the filter returned from the customer.We noticed that the fifth and sixth filter media were dyed dark with toluidine blue.Therefore, occlusion may have occurred, and blood may have been filtered by the filter area that was smaller than usual, and the linear speed (flow rate per unit area) increased.Thus, the leukoreduction failure (elevated wbc count) occurred.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
IMUFLEX BLOOD BAG SYSTEM
Type of Device
IMUFLEX WB-RP BLOOD BAG SYSTEM WITH LR FILTER
Manufacturer (Section D)
TERUMO CORPORATION FUJINOMIYA FACTORY OF TERUMO CORP
fujinomiya 418-0 004
JA  418-0004
Manufacturer (Section G)
TERUMO CORPORATION, FUJINOMIYA FACTORY OF TERUMO CORP
818 misonodaira
fujinomiya 418-0 004
JA   418-0004
Manufacturer Contact
makoto yoshikawa
818 misonodaira
fujinomiya 418-0-004
JA   418-0004
MDR Report Key16069034
MDR Text Key308531882
Report Number9681839-2022-00108
Device Sequence Number1
Product Code CAK
Combination Product (y/n)N
Reporter Country CodeUS
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional
Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date 12/29/2022
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number1BBWGQ506A2
Device Lot Number220517AF
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 12/08/2022
Initial Date FDA Received12/29/2022
Supplement Dates Manufacturer Received02/02/2023
Supplement Dates FDA Received02/17/2023
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Other;
-
-